That burner box is positive pressure, make sure all the screws are tight and the gasket material is intact. Always check combustion these burners crack very often . to see the flames theirs a holr on the left or right side of the boiler . also that air damper below the blower looked to be 90% closed ( That may be normal I’ve always worked on the larger models with 4 stages )
Hey man I love your videos. I'm just an apprentice right now at a small residential business. Any advice? I want that good money, but I'm trying to be patient and just learn, learn, and learn.
Read, study, google, UA-cam, ask questions every chance you get. I’ve been doing it for 6 years and still come home and study up on stuff during the week on stuff I’ve ran into that I don’t know too much about. Good field. Endless learning. Keep at it!
Great video really enjoy learning from your expieriences. I would say tho if you're troubleshooting, you should turn off the gas valve until you narrow it down to a gas valve problem for safety reasons. Otherwise great job 👍
На заметку тем, кто сталкивается с газовыми модулями в любом виде. Практически всегда из контроля зажигания присутствует контроль подачи внешнего воздуха/наддува для горелки (датчик давления, прессостат, дифманометр и иже с ними) в камере сгорания или модуле и оптический контроль присутствия факела после розжига. Есть ещё варианты, но это - основа, куда надо копать. Плюс в нормальных горелках есть контроль давления газа + клапан, в более простых - это внешняя часть обвязки (для котельных, обычно все завязано в одну цепь через контроль загазованности помещения).
The heat of the victory! Good one 👊
That burner box is positive pressure,
make sure all the screws are tight and the gasket material is intact.
Always check combustion these burners crack very often .
to see the flames theirs a holr on the left or right side of the boiler .
also that air damper below the blower looked to be 90% closed ( That may be normal I’ve always worked on the larger models with 4 stages )
Thanks for sharing. Good when many can learn from one experience from one person.
😳 boilers are tough. great video🎉
Great job always professional.
Good video ,its awesome all the different equipment you work on. Good job
Hm, maybe check Craigslist for the cover 😂
Nice to see the red gloves back! 💪🏼
Great job jmt troubleshooting master
I remember there being a small inspection window on the end of the boiler where water pipes connect.
Hey man I love your videos. I'm just an apprentice right now at a small residential business. Any advice? I want that good money, but I'm trying to be patient and just learn, learn, and learn.
Read, study, google, UA-cam, ask questions every chance you get. I’ve been doing it for 6 years and still come home and study up on stuff during the week on stuff I’ve ran into that I don’t know too much about. Good field. Endless learning. Keep at it!
@@SoutheastHVAC Very encouraging thank you! One thing I had to stop doing was looking at learning HVAC as a race and more as a marathon.
Move into commercial, at your first opportunity
If you want to earn real money, quit hvacr and look into becoming a politican.
I agree with Matt first chance you get go to commercial
Great video really enjoy learning from your expieriences. I would say tho if you're troubleshooting, you should turn off the gas valve until you narrow it down to a gas valve problem for safety reasons. Otherwise great job 👍
Good job, maybe a sheet of sheet metal to close gaps.
Not only dirt but the burners are pulling warm air from the building and pumping it outside, and that even sucks outside air into the building.
На заметку тем, кто сталкивается с газовыми модулями в любом виде. Практически всегда из контроля зажигания присутствует контроль подачи внешнего воздуха/наддува для горелки (датчик давления, прессостат, дифманометр и иже с ними) в камере сгорания или модуле и оптический контроль присутствия факела после розжига. Есть ещё варианты, но это - основа, куда надо копать.
Плюс в нормальных горелках есть контроль давления газа + клапан, в более простых - это внешняя часть обвязки (для котельных, обычно все завязано в одну цепь через контроль загазованности помещения).
I would suggest with the fast heat up. May have low water flow on that boiler. IDK, just a thought.
Did you check those burners??
Somebody guessed at the fan/motor due to the error code and didn’t do the most basic of checks.
Nice easy call next time scrape off old gasket
👍
Ya those things eat ignighters like crazy. Also it's short cycling wich doesn't help with ignighter life. Definitely junk boilers
U fix
You break, I fix 😂
Hot water boiler?
Who boils hot water?
Junk boilers
I call them pool heaters , no mass and a terribly design , Not ideal for space heating