    www.amazon.co.uk/Electric-sho...
    How to test and repair most electrical showers using very cheap tools and easy to do step by step tests and replacement procedures. Learn how to test all electrical components from the heater and thermal cut-out, the solenoid valve, and much more.
  • Навчання та стиль

КОМЕНТАРІ • 143

  • @cagmito76
    @cagmito76  2 роки тому +2

    Buy my electric shower repair book here on Amazon
    amzn.to/3suEo1T

    • @dilligaf2386
      @dilligaf2386 Рік тому

      I would but don't own a kindle is there a paper copy?

    • @cagmito76
      @cagmito76  Рік тому +1

      @@dilligaf2386 no sorry but you can download kindle and read any kindle books on pc laptop phone or smart tv

  • @vivviedarling9336
    @vivviedarling9336 6 місяців тому

    Thank you. Power shower, power, noise, but no water coming out. Purchased the solenoid valve for my model which arrived today and was fitted in under 5 minutes. Shower works! Happy family, happy days.

    • @cagmito76
      @cagmito76  6 місяців тому

      Great to hear! nive work bud.

  • @georgemcnally4473
    @georgemcnally4473 8 місяців тому

    Great vid, thank you. You broke it down to simplicity itself and enabled even a clod like me to solve the problem.

  • @stepahead2523
    @stepahead2523 Рік тому +1

    Cagmito76,
    I checked all your video and found the fault which replacing the temp sensor, i managed to replace it and the shower working perfectly, saved a lot of money replacing with new shower, M8
    thank you very much

  • @jumpferjoy1st
    @jumpferjoy1st Рік тому +1

    Thanks for this. The Pressure Release Device has gone on our Triton, so now I can get it replaced easy. Thanks again. If it goes again quickly then obviously there are other issues, but your video has helped massively. Cheers.

    • @cagmito76
      @cagmito76  Рік тому

      No worries and thanks for comment, appreciate it!

    • @BlackKnight_217
      @BlackKnight_217 4 місяці тому

      Can you please confirm when the PRD was blown out, there was no hot water and then when you replaced the PRD you got hot water again ??
      My PRD seems to have blown out, I ordered replacement discs that should arrive in a couple of days, but also I have no hot water right now,,, will replacing the PRD disc also resolve the hot water issue ??

  • @MaxMax-th7uz
    @MaxMax-th7uz Рік тому +2

    Probably the best video on UA-cam !

    • @cagmito76
      @cagmito76  Рік тому

      Thanks max glad it helped you!

  • @jamescodling8641
    @jamescodling8641 2 роки тому +1

    Wow. Excellent... Very thorough. Thanks buddy appreciate your expertise

    • @cagmito76
      @cagmito76  2 роки тому

      Thanks for comment James !

  • @gerfome
    @gerfome 6 місяців тому

    Got my shower heating going again, though I dont know why. Thanks anyway , your video was most informative and helpful.

  • @CH-en4er
    @CH-en4er 9 днів тому

    Thanks , great video.

  • @tommyshelby9080
    @tommyshelby9080 3 місяці тому +1

    Thanks so much mate I changed the valve works fine! And I look like I no what I’m doin to my Mrs haha cheers mate I’ve subbed

  • @Mark-wl7fp
    @Mark-wl7fp Рік тому +1

    Hi great video. I have just fitted a triton T80si where it will not switch off and water is leaking constatnly. I have replaced teh diaphram and solenoid valve but its the same scenario. I have just tested the on/off switch with a multimeter and that checks out ok. Im a bit stuck now.

  • @tweetypie25
    @tweetypie25 6 місяців тому

    Useful video, well explained.

  • @jackckng5316
    @jackckng5316 Рік тому +2

    Hi cagmito, I got brand new triton t80 just fitted week ago and working fine .
    Yesterday when I’m going shower for 10mins and heard a click then no hot , turn it off for few sec and on again then hot water coming back .
    Hope you can answer my question .. thanks

  • @nickbyrne2983
    @nickbyrne2983 3 місяці тому

    Thank you

  • @porg78
    @porg78 Рік тому +1

    Hi, we've replaced our Gainsborough e50 shower with a new Gainsborough e50 unit as the old one started going hot and cold and then didn't heat up at all.
    The new shower unit is fitted, power comes on to it and it isn't tripping the RCD. Water pressure seems fine but the new unit isn't heating up either? Any ideas as to what the problem might be?
    Ps don't know if it matters but our combi boiler went faulty around the same time s the shower stopped working properly and have been told that it needs a new divertor valve (cycling on and off every few seconds) and radiators heat up when selected to tap water only mode.
    Many thanks in advance

  • @smithers139
    @smithers139 8 місяців тому

    Changed for new one gave me chance to look at the old one fault was with the two micro switches that turn on either of the elements

  • @CH-en4er
    @CH-en4er 9 днів тому

    Thanks, great video

    • @cagmito76
      @cagmito76  22 години тому

      Glad you liked it!

  • @skerdiselamaj
    @skerdiselamaj Рік тому

    Best video
    How can I fix the pressure of my electric shower

  • @romanas1967
    @romanas1967 9 місяців тому

    Thank you so much 👌

  • @oddball6992
    @oddball6992 Рік тому

    My aqualisa quartz 9.5 has now started to struggle with water coming out and what water that does is red hot. Is it the solenoid or flow valve

  • @AdamAdam-gx6pt
    @AdamAdam-gx6pt 3 місяці тому

    Hi mate how do you remove the olive and nut?

  • @donny1255
    @donny1255 Рік тому +1

    Thanks, a replacement solenoid was needed and it cost €10 to do it 👍

    • @cagmito76
      @cagmito76  Рік тому

      Nice work! and thanks for comment.

  • @Chris-jy3dm
    @Chris-jy3dm 7 місяців тому

    Hi my t80si comes on hot on hottest setting but when I turn it down to medium setting it’s just cold can’t get a medium temperature thanks in advance 👍

  • @harrycarter9129
    @harrycarter9129 2 місяці тому

    Will changing the shower head for a bigger head make the temperature of the water uncontrollable, thanks

  • @fredmercury1314
    @fredmercury1314 Місяць тому

    Mine is an Aquatronic Ultra 4 and it's scolding hot. It switches on a "low pressure" warning light, then switches the heater off.
    It's fine on setting I, apart from it being "cold", but on setting II it's a liability. This morning I had the dial right the way over to maximum cold, and on setting II, and it tried to burn me alive.
    Is that the flow valve? I live in a high limescale area... I'm thinking something is clogged.
    Thanks!

  • @Shandybrother
    @Shandybrother 2 роки тому

    Any idea what’s the difference between the gravity and mains pressure versions of the T80
    can the gravity version be modified to the mains pressure version, thanks

    • @cagmito76
      @cagmito76  2 роки тому

      Usually there is a pump is inside them.

  • @nickdodge4668
    @nickdodge4668 2 роки тому

    Having an issue with my triton madrid 2, was working fine one day, the next the isolator switch light comes on and sets to on, no light on the shower though no power just doesn't turn on and the isolator light goes off when trying to turn it on. Any idea and fix?
    TIA

    • @cagmito76
      @cagmito76  2 роки тому +1

      you need to test to see if you have power to the switch and at the shower , its more than likely a faulty isolator switch though

  • @Plumb4
    @Plumb4 7 днів тому

    Triton Seville shower keeps running hot and cold any ideas of the problem ?

  • @chatchatty2155
    @chatchatty2155 2 роки тому +1

    Good video what if I bypass that too till I get a new one I took my faulty one apart it was in peace’s in side so I removed the bit put back both discs no I have a reading on my multimeter

    • @cagmito76
      @cagmito76  2 роки тому +1

      Becareful though as safety devices are there for a reason and cut of supply to avoid burns etc.

    • @chatchatty2155
      @chatchatty2155 2 роки тому

      @@cagmito76 is there a inside diagram of the two on how it actually works

    • @cagmito76
      @cagmito76  2 роки тому

      @@chatchatty2155 Is it the TCO , not sure might be worth searching internet for one.

    • @chatchatty2155
      @chatchatty2155 2 роки тому

      @@cagmito76 yes the two it would be handy to no how it works inside view triton t80 fco

  • @denisemaas8201
    @denisemaas8201 2 роки тому

    Hi, mums shower is a Mira advance ATL Thermostatic and has No power when turned on at ceiling... checked fuse inside shower and switch in ceiling has electric flow, just not power to unit? There was water sitting in the top heater element tube around heater switch.
    Me mums desperate and just unsure with not wanting her to get ripped off x

    • @cagmito76
      @cagmito76  2 роки тому

      I would not be doing live main voltage testing if you are unsure , best to get technician out . Where are you located. Switch off electric at consumer unit use you meter in continuity mode to test switch and incoming mains connection in shower dead testing is much safer . If you do not have continuity through switch you need new switch. Hope fully thats your issue these are quite expensive showers to buy and repair.

  • @blackopspilled
    @blackopspilled 2 місяці тому

    What does it mean when it makes a load buzzing noise

  • @CelerEtAudax3256
    @CelerEtAudax3256 2 роки тому +1

    Any ideas what’s going wrong if the water is either really hot or if I turn it to cold it’s freezing. There no in between. Thanks 🙏

    • @cagmito76
      @cagmito76  2 роки тому +1

      Could be flow related or electrical.

  • @fijordan01
    @fijordan01 2 роки тому

    I used a stone pressure head on my electric shower and my friend pressed the buttons now it’s just cold! Any ideas on a fix or is it a new one? Thanks

    • @cagmito76
      @cagmito76  2 роки тому

      test the tco and heater and then midro switches

  • @SB-tp3yw
    @SB-tp3yw 16 днів тому

    if working on a shower does it need to be removed from the wall? i need to change the heater tank triton cara

    • @cagmito76
      @cagmito76  16 днів тому

      no not on most i only did it for ease of video

  • @stewartmcardle8149
    @stewartmcardle8149 2 роки тому +2

    Perhaps the 6th ought to be highlighted ....that of the inaccessible* stabiliser valve seal .....which creates the same effect as a failed PRD.....leaking ...
    (* without taking the unit off the wall)....

    • @cagmito76
      @cagmito76  2 роки тому

      yeah , got video of this somewhere but its not hard to remove unit from wall either , thanks for comment

  • @Abhorrent-Tom
    @Abhorrent-Tom Рік тому

    Thank you, it’s the solenoid on mine kept cutting the water in and out, tested it and it’s at 4.5 ohms. Is that good or bad?

    • @cagmito76
      @cagmito76  Рік тому +2

      it should be 3.7 to 4.5 K ohms, but they can expand the copper wires inside when hot and cut out.

    • @Abhorrent-Tom
      @Abhorrent-Tom Рік тому +1

      @@cagmito76 thank you

  • @trianedtog0417
    @trianedtog0417 3 роки тому

    Good to see you back i have half a day's work for you if you want it pay all your petrol ⛽ and time i am a crippled and need my rs125 09 model fairing oil pump and front brake fitted can you do it please Good money i am in hull

    • @cagmito76
      @cagmito76  3 роки тому

      hull way to far for me bud sorry , nice place though did go once.

  • @benokunhon7665
    @benokunhon7665 3 роки тому +1

    Hey cagmito! Ive got a yamaha wr125x and I was wondering do you know the resistance for the stator coils? Would help a lot! (Has same motor as yzf r125)

    • @cagmito76
      @cagmito76  3 роки тому +1

      forget now sorry but if you find out update so i can write down again

    • @benokunhon7665
      @benokunhon7665 3 роки тому

      @@cagmito76 Mine was at 1.4 - 1.5ohms and someone told me it should be 0.45 - 0.67ohms so should i replace my stator or does that matter?

    • @cagmito76
      @cagmito76  3 роки тому

      @@benokunhon7665 i checked mine measure 0.45 its a lot over it would affect generation did you do battery test 12v off it should jump to 14v when running and over 3/4000 revs

    • @benokunhon7665
      @benokunhon7665 3 роки тому

      @@cagmito76 Have to check that tomorrow, will update you then. Thank you so much for helping!

    • @benokunhon7665
      @benokunhon7665 3 роки тому

      @@cagmito76 The battery was at 12.6V off and when I started the bike it was 14.6V but I didnt rev the bike at all

  • @noisejunkiesofficial
    @noisejunkiesofficial 2 місяці тому

    No heat. Checked the TOC and it didn't have resistance, checked the heating elements and both had resistance of approx 12ohms, but when i checked the solenoid on the inlet the multimeter read 1250. I'm no expert, i decided that as we had a shower head that had an on off switch, and had been accidently shut off, this has likely effected multiple components in the shower so we decided to get identical shower replacement for £69,

  • @ronaldmartin7892
    @ronaldmartin7892 2 роки тому

    Interesting. My Whirlpool shower will only heat on low and no indicator lights come on, on Medium and Hot.? Any suggestions please?

    • @cagmito76
      @cagmito76  2 роки тому +1

      could element or microswitch have a test see what it you find , if it s PCB controlled its an extra complication

  • @mrafeht
    @mrafeht Рік тому

    New triton t80 on/off switch not working is there a quick fix, please

    • @cagmito76
      @cagmito76  Рік тому

      Not really a quick fix or at least any id be comfortable with , best to replace it they are cheap.

  • @antoniogalluccio4213
    @antoniogalluccio4213 2 роки тому

    If there is low water flow when the selector switch is on hot and good when it is on cold and doesn't heat up, what could be the problem?

    • @cagmito76
      @cagmito76  2 роки тому

      Could be limescale build up on element , could be element failure one of them or failing or not being switched on , under power if new.

  • @sickbeatsproductions
    @sickbeatsproductions 5 місяців тому

    we have had 4 triton showers and all last around six months then they wont run hot at all, just freezing cold water??? what could be causing all to blow so quickly? and how do i check??

    • @KatrinaMcevoy
      @KatrinaMcevoy 4 місяці тому +1

      Omg I thought I was only one!! We've gone through 3 in the past year!!! Did you ever find out why? I am starting to think I've got a problem with the electrics that keep shorting the heating element

    • @sickbeatsproductions
      @sickbeatsproductions 4 місяці тому

      @@KatrinaMcevoy turned out that we had used longer hose and different shower heads, triton showers only use short hose and a crappy head, made for low pressure! so if you use anything else the shower cant cope with the pressure needed

  • @thegoon-w3g
    @thegoon-w3g Рік тому +1

    My broken it had burning smell and it doesn't eorj

  • @ethanfletcher8669
    @ethanfletcher8669 4 місяці тому

    If the solenoid doesn’t have continuity does that mean it’s knackered ?

    • @cagmito76
      @cagmito76  4 місяці тому

      yes needs replacing

  • @katrinaporter614
    @katrinaporter614 Рік тому

    The power switch I pull the string the light comes on very faint and the shower just does nth come on at all what could that be please.

    • @cagmito76
      @cagmito76  Рік тому

      give the entire installation a good test and inspection

  • @rajagatta7844
    @rajagatta7844 11 місяців тому

    Hii
    I have a electric shower, but the shower is not working properly the water is stopping for couples of minutes and coming back and stopping again can I know the problem is

    • @AA_Athene
      @AA_Athene 8 місяців тому

      He literally explains this go to the end part called most common faults

  • @johng7787
    @johng7787 2 роки тому

    My TCO keeps failing. 3 in 3 weeks!!
    There doesn’t appear to be any scaling and when I changed the inlet filter again no sign of scaling. Pressure and flow seem ok. I take a shower with no fluctuations in pressure and temperature then the next time just cold water. Heating tank at 11.3 and 11.2 ohms. TCO at 0 when fitting and when failed at 1.
    Any suggestions greatly appreciated

    • @cagmito76
      @cagmito76  2 роки тому

      It sounds like you checked most things , if your getting good flow through shower , head is not blocked and hose is no collapsed internally. Id suspect the elements either faulty or limescale. It is usually limescale build up.

    • @johng7787
      @johng7787 2 роки тому

      @@cagmito76
      Thankyou for your reply and advice.
      Is it possible to clean the limescale from the tank or would it need a new unit (Cheapest I’ve seen is £129) If I can clean it how do I go about getting rid of the limes ale build up on the elements please and what would I use to do this. If it is possible it’s probably worth a try would you say?
      I can’t just keep replacing the TCO at £23 a go tbh but I do have another one.
      I do keep seeing different numbers on the top of the TCO but the shower sales say they’re ok for my shower.
      One said 52 - 75 and another 48 - 75
      Once again .. thanks
      John

    • @cagmito76
      @cagmito76  2 роки тому +1

      @@johng7787 There is a video on here of someone doing it im not sure of how successful never tried myself

    • @cagmito76
      @cagmito76  2 роки тому

      @@johng7787 If you go to my description in video there is link to my blog ( buy parts ) scroll down page and there are links to TCO for 14.99.

    • @cagmito76
      @cagmito76  2 роки тому

      @@johng7787 ua-cam.com/video/4-2-6LWIMKw/v-deo.html

  • @siphiwesiame5880
    @siphiwesiame5880 2 роки тому

    What could be the problem when the water heater is on and shows all lights but the temperature stuck on Cold and 25°c

    • @cagmito76
      @cagmito76  2 роки тому

      You really need to test to find out, if its got a PCB it wil be more difficult to pin point.

  • @gabbybarnsy2830
    @gabbybarnsy2830 2 роки тому

    Hi my shower switches off the light stays on but the water stops coming out after around 10 mins. Shal i replace it then?

    • @cagmito76
      @cagmito76  2 роки тому

      Sounds to me like solenoid failure. Easy to replace. but test for to be sure

    • @gabbybarnsy2830
      @gabbybarnsy2830 2 роки тому

      @@cagmito76 i just gone and bought a new shower 😂

    • @gabbybarnsy2830
      @gabbybarnsy2830 2 роки тому

      I got the exact same model tritan 2 madrid i hope i can put it up by myself tonite

    • @cagmito76
      @cagmito76  2 роки тому

      @@gabbybarnsy2830 It not too difficult just turn of water and electric and be careful.

    • @gabbybarnsy2830
      @gabbybarnsy2830 2 роки тому

      @@cagmito76 is there any chance i can cal you when im starting off? Later on i can give you my no

  • @mrmikeh-nv7cq
    @mrmikeh-nv7cq 2 роки тому

    I've changed the prd and for some reason it won't get hot now.

    • @cagmito76
      @cagmito76  2 роки тому

      You must have a second fault do some tests on electrics

  • @Chris-jy3dm
    @Chris-jy3dm 7 місяців тому

    Ps the pink thing just drops to green when I turn the temperature down thanks again

  • @erikmorales1004
    @erikmorales1004 2 роки тому +1

    hi my shower is very lower pressure on the heat temperature setting. It comes on for 2 seconds at high temperature then cuts out and the pressure goes very low to a trickle of water. What could be he issue? thx

    • @cagmito76
      @cagmito76  2 роки тому

      Do some tests check heating elements maybe one has gone , is the water pressure good , any blckages is the water flowing through the shower and pipe and shower head ok ?

    • @erikmorales1004
      @erikmorales1004 2 роки тому

      @@cagmito76 hi thanks for getting back to me appreciate it. The flow of water is fine when the water is turned to cold but not when run got it is a trickle.

    • @cagmito76
      @cagmito76  2 роки тому

      @@erikmorales1004 Let me have a think on that , its hard one as usually low pressure is affected when hot or cold as heat in controlled electrically. Maybe its overheating and cutting out but ill have a think and get back.

    • @cagmito76
      @cagmito76  2 роки тому

      @@erikmorales1004 What model do you have Erik ?

    • @erikmorales1004
      @erikmorales1004 2 роки тому

      @@cagmito76 I think your correct it seems to be cutting out and the water get very hot and it makes a click noise then the water stops.

  • @karhukivi
    @karhukivi 6 місяців тому

    Motor running but no water? If it is very col weather, check for a frozen supply pipe before going after the solenoid! I'm lagging mine now after discovering the real cause of no water.

  • @saimaahmed4258
    @saimaahmed4258 2 роки тому

    Water leaks from the bottom of the shower. When I took off the shower head, there was no leak. So I replaced the shower head and even with a brand new one, there is a leak from the bottom of the shower.
    So it seems I can’t put a shower head on the shower lol!! Anyone got any ideas on how to resolve? Thx

    • @cagmito76
      @cagmito76  2 роки тому

      are you sure is not coming from the prd

    • @saimaahmed4258
      @saimaahmed4258 2 роки тому

      @@cagmito76 Hi, no I’m not sure at all…I’m out of my depth here. Given what I’ve already described can it be the prd? It costs about £5 to purchase n thn I can follow a video to fix it!

    • @cagmito76
      @cagmito76  2 роки тому

      @@saimaahmed4258 Here is a video of one dripping , badly some are not quite so bad as this ua-cam.com/video/nsRRRDWwlWM/v-deo.html

  • @smithers139
    @smithers139 8 місяців тому

    My shower cold till you turn up to 8 the it gets very warm turn it to 5 it goes cold but turn it to 6 for a bit then down to 5 ok

    • @cagmito76
      @cagmito76  8 місяців тому

      electric showers heat by flow rate of water so check for inlet pressure blockages filters blockage internal hater can , flow stabilser valve wear , out let pipes.

  • @dilligaf2386
    @dilligaf2386 Рік тому

    Tou sound like you know what your talking about, What about this one power off and cold water coming out of the shower I've had to turn the stopcock off under the sink. PRD ?

    • @cagmito76
      @cagmito76  Рік тому +1

      sound like solenoid inlet valve is not closing

  • @davidkeitel7297
    @davidkeitel7297 2 роки тому

    on my electric shower the water is very very hot even when i turn it to low can you tell me what is wrong

    • @cagmito76
      @cagmito76  2 роки тому

      there is a problem with the flow it could be blockage or flow control valve.

  • @thingamejignobodyknows4346
    @thingamejignobodyknows4346 Рік тому

    Solenoid is on a car too lmfao

  • @stepahead2523
    @stepahead2523 Рік тому +1

    Sorry replaced the Selonoid only cost 10 pounds

    • @cagmito76
      @cagmito76  Рік тому

      Yeah they are the best fixes nice and cheap and easy.

  • @jamesjohno1180
    @jamesjohno1180 Рік тому

    I just have absolutely no power I can’t work out what it is

    • @cagmito76
      @cagmito76  Рік тому

      if you got no power it could be wiring , switches , pressure microswitches thermal cut out it needs to be tested but never test with electric on.

  • @____________________________.x
    @____________________________.x 2 місяці тому

    Mine has ‘hot for first few seconds, then just goes cold’ 🤷‍♂️

  • @zakiharoun4899
    @zakiharoun4899 Рік тому

    You are making too many assumptions that people know it in advance

    • @cagmito76
      @cagmito76  Рік тому +1

      This is part of a series if you watch playlist and buy book it might make a bit more sense.

  • @Plumb4
    @Plumb4 7 днів тому

    Triton Seville shower keeps running hot and cold any ideas of the problem ?

    • @cagmito76
      @cagmito76  5 днів тому

      quite a few issues can cause this from pressure non consistent flow through heater limescale maybe others.