Pentair Mastertemp 250 Gas Pool Heater Not Running Step by Step Repair of Gas Sensor
Вставка
- Опубліковано 26 сер 2024
- Mikey Pipes - Plumbing & Air By Tom, Inc.
December 31, 2023
Orlando, Florida
Step by step repair video guide of PENTAIR MASTERTEMP 250 pool heater with damaged gas sensor.
Hello 👋 Tom. Nice to Meet you. Keep up the Strong 💪 Efforts and Thanks for Helping make the Trades Great Again. 👍🙏
Thank-you stayed tuned for more great content!
Thanks, you too!
I knew it was going to blow with pump on. 😂 job well done Tom
🙏
@@MikeyPipesOrlando guess he got a little bit jumpy with the camera now. He'll be alright
Hi Tom Nice to meet you. Happy New Year.
Hi Scott. It’s me.
Thank-you!
Stayed tuned for more great content!
Happy New Year 🎆
Happy New Year and thank you for all of the informative videos.
Happy new year!
On the control panel there is a “Mode” button that has three functions as indicated in the box. Press the Mode button until the screen reads “Service”, your are now in Service Mode. Once in service mode you can manually control all your equipment, filter pump, heater etc via the buttons on the control panel. Once finished press the mode button until the screen reads “Auto”. By doing this you will not have to change programming.
Thanks for sharing
Oooooohhh shut that pump down first buddy. 😂
Got him!
Tommy 2 pipes !
lol
Hate to be that guy, but it's a 5/8 deep socket, not an 11/16... also, if you don't breach the filter and let the system drain down you will get A LOT of water when you pull any plug/sensor from the heater. Drain filter by opening the air relief valve, wait 5 minutes
Then take drain plug out of heater manifold. Once the heater drains you can replace what you need. DONT pull a plug or sensor when a pump running..
Thanks for sharing those tips & tricks.
Definition of punching your way out of a wet paper bag. Never double commented before
Thanks for sharing
Does it matter which terminal the cables reconnect to?
You gotta take a closer look at the wiring schematic
I changed the ags and it still will not heat my front panel only shows service heater. The front panel will not light up. The only light is the service heater light. Any suggestions. Thanks
Bad panel?
Guy, what are you getting into? Theses guys are using harbor freight tools? I had a girlfriend that went to pcb for vacation and never came back too?
Send her to Mikey Pipes
Mine won’t even turn on when I push the button? It worked last nite
Did you try opening the manual?
🤣
hi
First comment
Champion
I would have replaced that corroded terminal connection.
Thanks for sharing your feedback