Siemen's SIPART PS2 Manual Calibration ! SIPART PS2 Calibration in Hindi

Поділитися
Вставка
  • Опубліковано 16 чер 2019
  • Today I'm here explained that how to calibrate a siemens SIPART PS2 smart positioner in “ Manual Mode ”.
    This is the only video on UA-cam explaining Manual Mode calibration exclusively for you guys so please watch carefully.
    Also I request you to please share this special video and comment if there is any doubt/trouble during calibration.

КОМЕНТАРІ • 158

  • @vinaysane5435
    @vinaysane5435 Рік тому +1

    Excellent Sir & Very Thanks for showing how to calibrate Siemens Sipart PS 2 Positioner.
    Very Thanks Sir.
    💐💐💐💐💐💐💐🙏🙏🙏🙏🙏🙏🙏

  • @unfilteredwithprakash6970
    @unfilteredwithprakash6970 4 роки тому

    Sir, nicely explained, impressive. Keep doing such great work

  • @pareshrathod1482
    @pareshrathod1482 4 роки тому +1

    Thank you very much for great video
    Good work bhai

  • @sreenubabu6488
    @sreenubabu6488 3 роки тому

    Thank you my friend..good job and very useful information

  • @Ram-sx5mv
    @Ram-sx5mv 3 роки тому +1

    बहुत बहुत धन्यवाद भैया ये वीडियो बहुत helpful ह मेरे लिए ओर भी वीडियो बनाओ
    God bless u sr💐💐

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому +1

      शुक्रिया, आपका आशिर्वाद बना रहे 🙏🙏

    • @Ram-sx5mv
      @Ram-sx5mv 3 роки тому +1

      @@shantilaldhakar9967 भगवान से प्राथना करते ह आप हमेशा तरक्की कर ऐसे ही लोगो का भला करते रहे हेल्प करते रहे🙏💐😊

  • @sureshkumarverma5094
    @sureshkumarverma5094 3 роки тому

    Thank you very much . Good information.

  • @vthls
    @vthls 5 років тому

    Comprehensive! Thank you sir..

    • @shantilaldhakar9967
      @shantilaldhakar9967  5 років тому

      You are welcome

    • @pravinchavda9226
      @pravinchavda9226 4 роки тому

      Plz ...any vacancy for Instrument technician I am diploma in instrumentation and control engineering with 8year experience.plz give me your WhatsApp number...Pravin CHAVDA Gujarat Jamnagar

  • @mr.nizamulhoq851
    @mr.nizamulhoq851 4 роки тому

    excellent and so more helpful presentation

  • @rajeshsinghcimac
    @rajeshsinghcimac 4 роки тому +1

    Thanks a lot. nice presentation. (y)

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Sir, Thank you very much for your appreciation.
      I'm glad that my small video is helping thousands of people across the globe which was my main Moto for this upload.

  • @Marafeq344
    @Marafeq344 2 роки тому +2

    Thank you for the video

  • @Hewagej
    @Hewagej 2 роки тому +1

    Very good video
    Thank you so match

  • @vinaysane5435
    @vinaysane5435 8 місяців тому

    Very Good &Knowledgeable Video.👍👍👍👍👍💐💐💐💐💐🙏🙏🙏🙏

  • @kishoreKumar-wt4vi
    @kishoreKumar-wt4vi 4 роки тому +1

    Thanks ji for good posted. please do more videos on Siemens positioner troubleshootings also.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Thanks for appreciation and I will accept your feedback regarding video on troubleshooting.
      Thanks again...

  • @himmatgarg2239
    @himmatgarg2239 5 років тому

    Wa. Bhai .. Superb....

  • @BhagwanSingh-sv3kh
    @BhagwanSingh-sv3kh 2 роки тому

    Thank you helpful video

  • @rajarajan6291
    @rajarajan6291 4 роки тому

    Good job

  • @kunalpareta5908
    @kunalpareta5908 2 роки тому

    Great job 👍

  • @aamirkh4064
    @aamirkh4064 2 роки тому

    Thank you very much

  • @sunilrathod663
    @sunilrathod663 11 місяців тому +1

    Thanks bhai

  • @waqashabib1674
    @waqashabib1674 4 роки тому +2

    Nice representation, done the same and valve was properly calibrated

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 роки тому +1

    Good work

  • @abhijitpadhiary4349
    @abhijitpadhiary4349 3 роки тому +1

    Thank you 🙏, Nicely explained.

  • @manikr9465
    @manikr9465 3 роки тому +1

    It was good informative video that who worked in instrumentation filed especially in fild side.if you possible plse put more different type of positioner configuration and caliberation. For instance azbil

  • @MdAli-vg2ko
    @MdAli-vg2ko Рік тому

    Nice

  • @surajkumarkhunte1181
    @surajkumarkhunte1181 2 роки тому +1

    thank you

  • @AshokPrajapati-ec3qh
    @AshokPrajapati-ec3qh 2 роки тому

    Good sir

  • @himanshushekharpandey7186
    @himanshushekharpandey7186 6 місяців тому

    Thnx via

  • @hadiyalshailesh9748
    @hadiyalshailesh9748 4 роки тому +1

    Good

  • @dalimnath614
    @dalimnath614 3 роки тому +1

    Thank you

  • @madhavrabari4756
    @madhavrabari4756 2 роки тому

    🙏 Thanks 🙏

  • @soumyaranjanjilu7816
    @soumyaranjanjilu7816 2 роки тому

    Thanks for this video bt sipart ps2 all models calibration plz video make

  • @devispatel50
    @devispatel50 4 роки тому

    👍

  • @jitendrakumarsahu4087
    @jitendrakumarsahu4087 4 роки тому +1

    Parameters ka video banaye plz

  • @iqbalmehedi3423
    @iqbalmehedi3423 4 роки тому

    how can i attach a position feedback module?

  • @pushpasahu1910
    @pushpasahu1910 4 роки тому

    Sir Forbes Marshall positioner ka callibration ka video bnaeye

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 роки тому

    Eska full video dekhao with industry ka sir

  • @402san
    @402san 4 роки тому

    y end 1&2 ka limit set krne k liye - aur + ko ek saath press krna he kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Press & hold “ - ” button and note that control valve is fully closed, set it as your “ Yend 1 limit”.
      Similarly, press & hold “ + ” button and note that control valve is fully opened. This will be your “ Yend 2 limit”.

  • @mdfarhan3259
    @mdfarhan3259 4 роки тому

    Sir hm jb bhi esko calibrate karenge manual mode me le Jake hi krenge.auto me nhi Kar sakte hai kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому +2

      Auto mode me bhi kar sakte hai.
      Parameter no. 4 access karke “ + ” button Ko 5 seconds k liye hold karo to auto calibration start ho jayega.
      Also I had made a seperate video for auto calibration procedure so please watch that stuff on my UA-cam channel.
      Thanks

  • @haidarquarrar8848
    @haidarquarrar8848 Рік тому

    Sir auto calibration me run 2 me fans jaraha aur P 8.1 uske niche fault ka symbol and up 1 show kar raha Hai kaise setting karenge

    • @shantilaldhakar9967
      @shantilaldhakar9967  Рік тому

      Valve is either jam or may not open/close properly.
      There may be air leakage from seal/diaphragm in output side.
      Check for these issues

  • @thomaselsen1672
    @thomaselsen1672 2 роки тому

    after a manual calibration, i am getting a negative number on the positioner display because the valve is seating which is desired but the negative number is not. How do i make the display read zero when going under the lower set point of the manual calibration?? Please Help!

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      Your Positioner is mounted on which system i.e. Air to open/close actuator or power cylinder?
      Case 1: If ‘Air to Close’ type pneumatic actuator then check air pressure and ensure that it does not exceed specified limit.
      Case 2 : If power cylinder then you adjust through cushioning screw.
      And then repeat manual calibration procedure as explained in this video.

    • @thomaselsen1672
      @thomaselsen1672 2 роки тому

      @@shantilaldhakar9967 it is a fail to close valve. On a diaphragm actuating control valve. The system set points requires the valve to jump up to 20% open as soon as any Ma signal is applied. So the valve was manually calibrated to set the lower limit to that 20% open so when Ma is applied it would automatically go to 20% open and achieve desired set points. Since the new 0% is manually calibrated to 20% open and the positioner closes the valve all the way to its seat once it gets the close signal. the display will read a negative number now because it thinks it is -20% to the seat. I was wondering if there is any way to zero that number out on the display or a better way to set up that valve to be able to achieve those set points. Thanks for the Help.

  • @jitubabusay2826
    @jitubabusay2826 28 днів тому

    19 mA mai 100% open karna hai to kya kare please batayiye

  • @vipulgp9843
    @vipulgp9843 4 роки тому +1

    auto caliberation ke time run2 me up 1 error dikha raha hai....kya problem ho sakta hai???

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      It's upper limit or open limit is not in the range that's why that error arises.
      So adjust the feedback positioner link with control valve and adjust in open condition with the help of friction clutch gear available on positioner.

  • @Diwa94
    @Diwa94 Рік тому +1

    up and down dono saath me push karte ho , ye to bolte nhi ho

  • @Ajayyadav-nh3qb
    @Ajayyadav-nh3qb Рік тому

    how to set her feedback deviation

  • @SonuKumar-ju2ok
    @SonuKumar-ju2ok Місяць тому

    Zero karne ke liye bhi +ve and -ve button ek sath press kar rahe h and 100 karne ke liye bhi same kar rahe h ?

    • @shantilaldhakar9967
      @shantilaldhakar9967  Місяць тому

      Action fast karne k liye Aisa Kiya ha.

    • @shantilaldhakar9967
      @shantilaldhakar9967  Місяць тому

      +ve button press & hold and then press -ve button
      In this way your action become fast.

  • @atanuhalder322
    @atanuhalder322 4 роки тому

    Sir my calibration is running at run4 continuously is not going at run5 please help me

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Dear friend,
      RUN 4 step during calibration “ Determine the minimum increment length ” means positioner will increment command by smaller fractions in decimal points & simultaneously check feedback and if it doesn't match then positioner stucks in RUN 4.
      Solution::
      (A) There may be leakage from fittings/diaphragm so check all fitting tightness.
      (B) The position FB link may be loose so check tightness.
      And then calibrate again you will definitely success.
      Thanks for your query and I hope this information helps you a lot.

  • @haidarquarrar8848
    @haidarquarrar8848 2 роки тому

    Open karne keliye EK button ya do boton EK sath push karna zaruri Hai kya

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      Single button se slowly open hoga
      and Two buttons ek sath press karne se fast open hoga.

    • @haidarquarrar8848
      @haidarquarrar8848 2 роки тому

      @@shantilaldhakar9967 thank you sir for reply

    • @haidarquarrar8848
      @haidarquarrar8848 Рік тому

      Sir EK problem Araha Hai valve auto calibration karne ke baad bhi valve 20 % hai aur command bhi 20 % araha Hai auto mode me lekin dcs me 0%show kar raha Hai valve kya karun ki valve fully close hojayye valve hamara fail to close Hai

  • @RamSingh-nj8mr
    @RamSingh-nj8mr 2 роки тому

    If positioner not operate in manual mode & not vary the opening percentage during manual command from positioner
    Plz help & how to contact you

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      My contact number 8003228484

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому +1

      May be air supply pressure is not sufficient or control valve/actuator is mechanically jammed.

  • @GauravKumar-xu9gh
    @GauravKumar-xu9gh Рік тому

    I have confusion for parameter 7 and 38 could anyone can explain please.

  • @instrumentpower6380
    @instrumentpower6380 2 роки тому

    सर मैं जैसे ही End1 देकर hand press कर रहा हूं Range लिखा आ रहा है End 2नही आ रहा है क्या चेक करू

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      “Range”means your range selected in “End1” or “End2” is incorrect. Please set it inbetween 10% to 85% at zero and span respectively. 👍

  • @sbibhureddy2255
    @sbibhureddy2255 3 роки тому

    Me Ra ek positioner auto/manual calibration nehi leraha he. Next Kia karunga

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      Please what's app your query/screenshot of error so that I may help you in a better way.
      What's app number 8003228484

  • @RizwanAhmad-wg6fs
    @RizwanAhmad-wg6fs 4 роки тому

    How to solve hunting and overshoot problems. There is no tube leakage but also hunting.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Check air leakage after positioner output from tube joints and actuator diaphragm.
      If this check is found normal then check the feedback positioner link connection. It may be loose or very tight so adjust link and properly tight again.
      After all that please make positioner calibration, I think your problem will get resolved.

  • @nikhilkapoor4561
    @nikhilkapoor4561 2 роки тому

    Positioner display is not getting power on ....22 v DC ... What will be the solution

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      If power is healthy then it's interface card may be faulty.
      Solution: Contact to supplier/vendor for repairing/replacement.

  • @manekmanek2617
    @manekmanek2617 4 роки тому

    Good brother what about hantting

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Hunting problem caused due to these possibilities ::
      1. Instrument air pressure drop after positioner output by any means including ALR failure or air leakage problem.
      2. If the spring tension is loose than required then it happens.
      Thanks for appreciation and query.

  • @odishabirdlovers3827
    @odishabirdlovers3827 Рік тому

    Mera position reverse may kam kar rahahey kya karu

    • @shantilaldhakar9967
      @shantilaldhakar9967  Рік тому

      Check parameter no. 7 and select proper parameter i.e. “rise” or “fall”.
      Your problem will be resolved.

    • @odishabirdlovers3827
      @odishabirdlovers3827 Рік тому

      @@shantilaldhakar9967 thanks

  • @tariqueanwer9329
    @tariqueanwer9329 2 роки тому

    Sir mera actuator 0mm tk close nahi ho raha hai please help

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      Check your actuator specification and if it is air to close type actuator then set air pressure.
      Also, you may set pressure 5-10% higher than rated pressure.
      Secondly, if above things checked and ok but problem not resolved then ensure that actuator spring tension is ok or not.
      It may be due to high spring tension of actuator so adjust it properly. 👍

  • @kirtandas1974
    @kirtandas1974 3 роки тому

    Sir ek problem hai 100% command pe 66 % arha hai... Input
    Kya kare
    12 no parameters me ja ke chenge kar ke dekh liya par ho nahi rha .
    Please iska kya problem hai btae

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      Factory reset your positioner and then re-calibrate in manual mode. If you got any issue then feel free to comment regarding problem.

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      RESET :: Go to parameter no. 50 and then press and hold “+” button for 5 seconds. This action will factory reset your positioner.👍

    • @Pawankavlog24
      @Pawankavlog24 Рік тому

      @@shantilaldhakar9967 sir mere positioner me zero command dene pe 20% command aa rha h to kya problem hoga command zero nhi aa rha

  • @sajidaziz2862
    @sajidaziz2862 3 роки тому

    AoA
    sir my control valve ps2 positioner continue stuck on RUN 5 but not show finish option please giuide me

    • @sajidaziz2862
      @sajidaziz2862 3 роки тому

      if stroke 20 mm then we select 90 or 30
      but now i select 90 and selector switch on 90 same as follow in parameter 2 according to manual

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому +1

      @@sajidaziz2862 please select 33° angle and then lock that position at 33°.

    • @sajidaziz2862
      @sajidaziz2862 3 роки тому

      ok i will try now

    • @sajidaziz2862
      @sajidaziz2862 3 роки тому

      @@shantilaldhakar9967 sir but when we select 90??if stroke is more than 20??

    • @sajidaziz2862
      @sajidaziz2862 3 роки тому +1

      @@shantilaldhakar9967 Thanks for guidelines my job is done.

  • @hooshangalizadeh637
    @hooshangalizadeh637 3 роки тому

    how to adjust the display contrast ?

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      please share details/model no. of your Siemens positioner.
      It will be like “ 6DR5051 or 6DR5052” .

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому +1

      I had gone through the positioner manual but did not find any information about contrast control.
      FYI 👍

  • @pradipkumaryadav252
    @pradipkumaryadav252 3 роки тому

    If 41 blinking on screen then what will do

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      Check the Instrument air pressure, if it is not sufficient to open/close valve then this error occurred 👍

  • @SurenderSingh-sk3kn
    @SurenderSingh-sk3kn 3 роки тому +1

    Bhai maan ge chorre

  • @jitendrakumarsahu4087
    @jitendrakumarsahu4087 4 роки тому

    VEnd2 ke baad Range ka option aa rha hai , calibration nhi hota hai ,,kya kru bataye

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Please adjust the zero and span range and accordingly it's feedback too.
      The difference must be greater than 80% and then calibrate using above explained procedure.
      Thanks buddy

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Operate the valve using + & - buttons on positioner and set Feedback 0 at zero check and atleast 80 to 86 at span check.
      Then calibrate the positioner in auto/manual mode.

    • @jitendrakumarsahu4087
      @jitendrakumarsahu4087 4 роки тому

      @@shantilaldhakar9967 span and zero kaise set kare? Hindi me bataye sir

    • @jitendrakumarsahu4087
      @jitendrakumarsahu4087 4 роки тому

      @@shantilaldhakar9967 Jab Range ka Option aata hai us time + button press karne se Vend2 aa jata hai fir se

  • @sagarmali8393
    @sagarmali8393 Рік тому

    What is meant by U- di error

    • @shantilaldhakar9967
      @shantilaldhakar9967  Рік тому

      means positioner feedback is inappropriate with respect to command signal.

    • @shantilaldhakar9967
      @shantilaldhakar9967  Рік тому

      futher you may adjust it by roller gear mounted just below display.

  • @sbibhureddy2255
    @sbibhureddy2255 3 роки тому

    Siemens positioner ko kese single action karenga.?

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      Make one output lower side port dummy and connect connect control valve to the remaining port.

  • @mrinmoysahoo8626
    @mrinmoysahoo8626 2 роки тому

    Agar run 1 ya run 4 ma error ageya to kya karna chahiye

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому +1

      Error in RUN 1 means either actuator/power cylinder is jammed or air pressure is not sufficient.
      Please check air pressure, pressure seal condition and jamming of valve/actuator.

    • @mrinmoysahoo8626
      @mrinmoysahoo8626 2 роки тому

      @@shantilaldhakar9967 thanks

    • @mrinmoysahoo8626
      @mrinmoysahoo8626 2 роки тому

      Or run 4 kya matlab hai

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому +1

      @@mrinmoysahoo8626 It's my pleasure to help you 😊

    • @shantilaldhakar9967
      @shantilaldhakar9967  2 роки тому

      @@mrinmoysahoo8626 RUN 4 : Positioner check and determine the minimum increment length so if error means there may be air leakage through actuator/power cylinder pressure seal parts.
      Please check and ensure that their is no any such leakages. 👍

  • @parmarashvin3993
    @parmarashvin3993 3 роки тому

    Sir ye 90°And 33 ° me kush samj nahi aa raha kush jyada jankari de sakte he please... Sir...

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      In case of linear actuators, if valve stroke is less than 20 mm then we select 33° transmission ratio else for valve stroke more than 20 mm we select 90°.

    • @parmarashvin3993
      @parmarashvin3993 3 роки тому

      @@shantilaldhakar9967 ok thank you sir

    • @mayankparmar4850
      @mayankparmar4850 3 роки тому

      Muje bi isme samaj nahi aaraha hy

  • @8899122246
    @8899122246 2 роки тому

    Feedback kaise set krenge

  • @parmarnil4748
    @parmarnil4748 3 роки тому

    0 jaga pe 100%dikhae और 100 % जगा 0 dekha to kya karne ka

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      केवल फीडबैक गलत आ रहा है या कंट्रोल रूम से कमाण्ड ही गलत आ रही है।

    • @shantilaldhakar9967
      @shantilaldhakar9967  3 роки тому

      Check parameter No. 7 and 38.
      If position feedback is just reverse then change parameter no. 38 from rise to fall and vice versa.
      And if command signal is reverse then change parameter no. 7 as explained above.
      I hope you got solution, further feel free to contact if you have any query.
      Thanks

  • @alijee4876
    @alijee4876 4 роки тому

    Yar agir new install karna hai tu kary ga

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Same procedure will be followed for newly installed positioner.

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому

      Please share your email ID so that I may help you by providing sufficient documents.
      Thanks

    • @alijee4876
      @alijee4876 4 роки тому

      alijee.aj137@gmail.com

  • @sreenubabu6488
    @sreenubabu6488 3 роки тому

    Friend if possible English language

  • @PradeepKumar-qk3qo
    @PradeepKumar-qk3qo 3 роки тому

    Can you learn me sir ji

  • @mayurparmar104
    @mayurparmar104 5 років тому

    Control valve mera open hai to zero dikha raha hai.. Or close hone par 100 dikha raha esa kyu

    • @shantilaldhakar9967
      @shantilaldhakar9967  4 роки тому +1

      Please check perameter no. 7 & 38 both parameters must be selected “ rise ” instead of “ Fall ” and then calibrate in manual mode as described in this video.
      I hope your problem will be resolved.

    • @kishoreKumar-wt4vi
      @kishoreKumar-wt4vi 4 роки тому

      Yes correct ji.

  • @bhagwansinghlodha939
    @bhagwansinghlodha939 2 роки тому

    kavi kavi error aati h calibration nhi leta h wo

  • @sambalpurisongsulhabaysi.8343

    har waqt kya dono + aur - button ko press kar k karna padega...agar nahi to dono ungli se kyon chek dete ho...

  • @janmuhammad2751
    @janmuhammad2751 2 роки тому

    Good