Passing Solar Electrical Cable Through a Roof.

Поділитися
Вставка
  • Опубліковано 20 січ 2025

КОМЕНТАРІ • 30

  • @mischafellner8943
    @mischafellner8943 Рік тому +2

    Hey soladeck you guys rock. It’s true your soladeck roof box has proven its greatness. Here in N California we standardized this great box (*with incorporated roof flashing). ....for most asphalt shingle installations and some flat tile( with secondary flashing underneath). But seriously your product is nearly perfect. Multiple hundreds installed. 0h yah.....Please move the interior upper romex concentric knockouts down about 1/4”.

  • @AlpineDividends
    @AlpineDividends Рік тому +1

    Solid video! Thanks for all the detail. I installed my first soladeck last week but into an attic. Cheers bud eh

  • @GregoryDibb
    @GregoryDibb Рік тому +2

    what did you use to mount that 6x6 gray junction box to the rail? You called them "chiclets" or "k-nuts?" This is at 29:05

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому +1

      Sorry for the delay as this was missed. We use the Knuts. I don't no why these aren't populating please call 844-548-7297 toll free and we can support you with mounting a JB

  • @brentfrank7012
    @brentfrank7012 10 місяців тому

    I find that lifting the shingles first with the flat bar then cutting your shingles with large scissors takes about half the time. In my opinion you should dress those nail holes you pulled out with roof mastic and the entire bottom of the metal flashing under the shingles with mastic as well. Very clean electric work, great demonstration. Thank you.

  • @agrxdrowflow958
    @agrxdrowflow958 11 місяців тому

    Fun to watch a master.

  • @MiningChef
    @MiningChef Рік тому

    Great video 🎉

  • @atranimecs
    @atranimecs 2 роки тому

    Awesome stuff, thanks for showing us.

  • @Orbacron
    @Orbacron Рік тому +1

    Do you ever have to use conduit over the mc4 panel wires in order to prevent mice or squirrel chewing through the mc4 cable sheathing🤔

  • @donpickerel9507
    @donpickerel9507 Рік тому +1

    Great video and use of different angles to show every detail.
    I'm curious about the step bit. Wouldn't a knockout set leave a better hole? At least that's what we used to use.

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому

      Thanks, Don
      Absolutely. A knockout kits will work as well but you may find it cumbersome given the depth of the box. Now most often a step bit can be acquired readily or already carried with an installer’s tool vs a knockout kit isn’t.

  • @robertwodnicki5597
    @robertwodnicki5597 2 роки тому

    awesome video

  • @ericroang685
    @ericroang685 Рік тому +1

    How far back are the PV panels from the 2 foot overhang ?
    Thank you for the videos.

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому

      Sorry for the delay. Great question. Setback around the perimeter of the roof should generally be 12". You want to consider if you're too close the the eaves edge, the rain will shoot off the solar panels and miss the eavestrough. Other consideration are cleaning the panels and access. Always leave yourself enough room to navigate safely while maximizing the solar production.

  • @csharknet
    @csharknet Рік тому

    good video thank you

  • @johnlee7691
    @johnlee7691 Рік тому +1

    Can you connect emt to the bottom of the soladeck through the roof eave?

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому +1

      Absolutely you could. You either need to bend your EMT for the offset required or transition from EMT to flexible conduit to make a proper connection. Dont forget to consider bonding methods for your jurisdiction!

    • @joeee7943
      @joeee7943 Рік тому

      The wire in x flex tube going from the soladeck device appears to be laying on the roof, should not be raised up off the roof by 7/8”?

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому

      Hello Joe, You could have that option depending on your particular installation requirements.

  • @dfreadhoff
    @dfreadhoff Рік тому

    See you are at 411 subs and know how important 500 is so I gave you mine!

  • @jackmehoffer7819
    @jackmehoffer7819 9 місяців тому

    Wow way harder than it needed to be.

  • @ar007r
    @ar007r 10 місяців тому

    suscribed

  • @christianklinger6826
    @christianklinger6826 Рік тому

    so teure sachen. mach das doch ordentlich ohne kratzer bitte.

    • @raysolarmadeeasy
      @raysolarmadeeasy  Рік тому

      Wir sind uns nicht sicher, was Sie meinen und warum Sie es für teuer halten. Dies ist eine ordnungsgemäße und übliche Installation. Vielen Dank fürs Einschalten.( We are unsure what you mean and why you feel it's expensive. This is a proper and common installation. Thank you for tuning in.)

  • @navsoltani
    @navsoltani Рік тому

    Impressive idiot-proof video!