  • @ПавелХоречко
    @ПавелХоречко 4 роки тому +1

    Всё чётко,быстро,качественно!!!👍👍👍

  • @gentry7921
    @gentry7921 2 роки тому

    Excellent DIY video. No BS. Crammed a lot of useful information into a short clip. I wus all DIY videos were this good.

  • @soroushsam7
    @soroushsam7 2 роки тому

    I liked your presentation and the music too, everything was awesome, nice, and professional work presentation. thanks to Как заменить вытяжку в ванне

  • @nickblack7468
    @nickblack7468 3 місяці тому

    Why the flex bracket wasn't install? I figured it out during my personal installation. it is because the old fan was attached directly to the wood and the original hole was made according to that situation. So, if in this case you will make a hole to use a flex bracket, you will have an extra space between the flex bracket and the main chassis of the new fan because there're some extra lips on the flex bracket for its screw secure attachment to the wood. To eliminate this issue and to install the fan flush with the new opening, the installer created his new installation approach. Thanks to this video. I have used this installation approach as well.

    • @FixitAll
      @FixitAll  3 місяці тому

      @@nickblack7468 Thank you!

    • @FixitAll
      @FixitAll  3 місяці тому

      @@nickblack7468 Absolutely correct, when you already have wood on one side, then no reason to use bracket.

  • @FloridaRailfanKid803
    @FloridaRailfanKid803 Рік тому +1

    Awesome 👍

  • @jjsudlow
    @jjsudlow 3 роки тому +1

    Thanks, very instructive.

  • @abrahamabraham1384
    @abrahamabraham1384 2 роки тому

    Tks for the video just bought a Panasonic as my fan is done I noticed the vent hose that's another project don't believe my current fan has one its an older home

  • @everythinghomerepair1747
    @everythinghomerepair1747 4 роки тому +1

    Great job. However you need to put a cover on that junction box to meet code.

    • @FixitAll
      @FixitAll  4 роки тому

      Will do. One more fan there on next week.

  • @Samy-hh1wn
    @Samy-hh1wn 2 роки тому +1

    Awesome but man that music is so annoying

    • @soroushsam7
      @soroushsam7 2 роки тому

      I liked the music too, everything was awesome, nice presentation. thanks to Как заменить вытяжку в ванне

  • @JoJo-Chris
    @JoJo-Chris 3 роки тому +1

    👍 Thanks! Very helpful. One question, I noticed most folks aren't using the flex-Z fast bracket but rather are screwing through drywall to studs and blocking to secure the fan unit to the adaptor. I'm curious about this approach. It seems like it would be easier to avoid the flex bracket all together but I hadn't thought about doing it that way. Hope this makes sense.

    • @FixitAll
      @FixitAll  3 роки тому +2

      Never used metal bracket from factory box.
      All the time piece of 2x4 or similar board and 4 screws like in this video.

    • @FixitAll
      @FixitAll  3 роки тому +2

      Of course you can use a bracket, but only if you install it from attic.
      My work with Panasonic installation mostly from the room, and probably ones in a year from attic. So that's why i never used bracket.

    • @JoJo-Chris
      @JoJo-Chris 3 роки тому

      @@FixitAll great I'm going to try your method tomorrow! Thanks for the quick replies.

  • @liyilwot3320
    @liyilwot3320 4 роки тому +1

    Добрый день, как всегда приятно смотреть на вашу работу.
    Можно узнать, что вы используете для съёмки и монтажа видео.

    • @FixitAll
      @FixitAll  4 роки тому

      Здравствуйте. Начало видео видно и на 15:15 вы также можете увидеть камеру Sony на ножках. Ну а в ручном варианте моменты в этом видео с телефона Samsung 10.
      Все мои видео на канале сделаны в программе Pinnacle Studio 19.

  • @alexill
    @alexill 4 роки тому

    Merry Christmas!!

    • @FixitAll
      @FixitAll  4 роки тому

      Same to you and Happy new year!

  • @apex007
    @apex007 4 роки тому

    Why the junction box? Were the wires too short?

    • @FixitAll
      @FixitAll  4 роки тому

      Yep, just 6" short. Old connectors box was on left, new on right. And wire go straight down into wall to the switch. No way to pull out some inches more.

  • @Aspridis85
    @Aspridis85 4 роки тому

    инспектор рад будет такому монтажу коробки,когда дом продавать будут))

    • @FixitAll
      @FixitAll  4 роки тому

      Им главное чтоб была коробка, а как она там закреплена никто не делает этому замечаний. Ну не было у меня с собой той коробки что гвозди сбоку, только ремадельская с хвостиками :-)

    • @Aspridis85
      @Aspridis85 4 роки тому

      А крышечку сверху прикрутил на неё?)А не более чем в 4" от коробки,закрепил провода скобой?))

    • @FixitAll
      @FixitAll  4 роки тому +1

      @@Aspridis85 Ну ты зверь... Лаадно, в следующий раз установлю и прибью, я там вторую вытяжку ещё менять буду.