Haier Refrigerator Defrost Cycle checking steps
Вставка
- Опубліковано 3 чер 2023
- Excess Ice problem of Refrigerator.
Over Icing problem of Refrigerator.
Defrost problem of Refrigerator.
Excess Ice problem of Haier Refrigerator.
Over Icing problem of Haier Refrigerator.
Defrost problem of Haier Refrigerator.
Defrost problem of LG Refrigerator.
Excess Ice problem of LG Refrigerator.
Over Icing problem of LG Refrigerator.
thanks for your video. your explan is smuth and logic. i waiting for next subject. thanks again
Extraordinary...nice explanation
Excellent sir . thank you sir giving very clear and neat explanation it's very useful in the field.
Continue give the this type of part check videos sir and
new models Refrigerator and washing machine also
Thank you very much for this video, you saved me a lot of time and money with this!
Welcome
Very good sir.. nice explanation
Good
I have the model HRF-521DM6
Thank for this great explanation. One question, is it normal that when forcing defrost on PCB, pressing microswitch two times on PCB like in the video, defrost start but is switch off again after a few tens of seconds?
Yes, at Test Mode defrost will continue also until D sensor reach +10 degree. If temperature already have above 10 then PCB will provide supply to Heater only for ten seconds.
@@techsupport7898 In fact, I checked test mode defrost again while evaporator was full of ice. Same thing, supply to heater was off after tens seconds even defrost sensor was ice cold.
@@yannmoreau4605 that means issue with the Defrost sensor, giving wrong feedback to PCB, accordingly PCB power off the supply to Heater. In this case Sensor value changed. Not open or short.
My fridge is working but not cooling to -18
What can be wrong