Boiler not working. How to check heating pump.

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • Boiler not working, Checking pump, Radiators cold, No hot water

КОМЕНТАРІ • 71

  • @alanor76
    @alanor76 Рік тому +1

    Just waited 5 freezing days for the Ideal engineer to fix our boiler which was one year old and still under. warranty. He did exaclly you did!

  • @dantedante5599
    @dantedante5599 2 роки тому +1

    Thank you very much….my vaillant boiler wasn’t on for over 1 year as I’ve been away and when I come back didn’t work…..I’ve seen your video and I have done exactly the same and now the boiler is working fine
    Thousand thanks for this
    God bless you

  • @vitaheybridge8539
    @vitaheybridge8539 3 роки тому +3

    A million thanks for this video. On the coldest night of the year In Scotland so far, this saved the day. And the emergency plumber's bill.

  • @ourmail9044
    @ourmail9044 4 роки тому +4

    Thank you so much for this! My boiler was disconnected at work for an extension build and when I recommissioned it I had fault F75. I was getting ready to change the sensor and even the pump but after seeing your video I did what you said and the pump came right back to life. Cheers

  • @markbalanowski6762
    @markbalanowski6762 Рік тому +2

    Fixed my frozen pump! Made my day, thank you!

  • @andrewwalker4001
    @andrewwalker4001 2 роки тому +3

    Hit the pump with a hammer and bingo working again thank you spot on.

  • @cheaphungerskitchen211
    @cheaphungerskitchen211 3 роки тому +1

    This video was my salvation. Better than the engineer who came to my house, it was me thanks to this simple demonstration of professionalism. 🙏🏾

  • @1proplover
    @1proplover Рік тому +10

    Firstly you should mention that you should turn the power off to the boiler in case it kicks in whilst you are fiddling about with that small screwdriver in the pump. Secondly on the pump label in the 5 o clock position is an arrow - that is the direction of the pump - if you start turning it like you did in the opposite direction there is a good chance you will damage the pump vanes causing loss of pump pressure and having bits in the pump cylinder that will damage other vanes.

    • @radarwarrior5459
      @radarwarrior5459 Рік тому +1

      Firstly, he and you should mention, there is no need to open the bleeder completely. If the boiler is switched on and running, a simple half-turn would show you if the water pump is working if water and or boiling water gushes out! Then you know its working.

  • @strangerohnostsngerthings9837
    @strangerohnostsngerthings9837 2 роки тому +1

    thank you thank you thank you 1000000000000000000000 thank you You're a lifesaver I fix my boiler thank you

  • @GeghamSargisyan
    @GeghamSargisyan 9 місяців тому +1

    Thank you for perfect advice!!! You saved my day!!! Thank you!

    • @traceywheeler9171
      @traceywheeler9171 9 місяців тому

      Pump error code 281 I'm getting hot water but no radiators coming on. Did your hot water work before u did this pump fix?

  • @lancethrust9488
    @lancethrust9488 7 місяців тому +1

    ALL NEW PUMPS LOOK HARDER TO CHECK , HOW DO I CHECK IF THE TURBINE FROZEN

  • @nasedo3129
    @nasedo3129 Рік тому +2

    I can see my pump is spinning when I remove that threaded plug but the radiators are still cool to the touch. Could the impeller be broken? Is there any way short of draining the system and removing those four hex bolts and taking off the pump to visually inspect the impeller?

  • @ernestsdabolins626
    @ernestsdabolins626 3 роки тому +2

    Super ,Thank you very much.

  • @tigermoth61
    @tigermoth61 3 роки тому +1

    This is amazing, I was desperate and couldn't get hold of a gas engineer.. I wacked the pump hard several times and wow! the pump stated vibrating, and the boiler came on.. should I get a new pump?

    • @frosty_soda
      @frosty_soda 2 роки тому

      Yes, it stopped for a reason. Check the windings, it is probably old. Replace it

  • @user-rz6pg1nm4m
    @user-rz6pg1nm4m 3 роки тому

    Thank you very much! I fixed the heating pump on your advice, thank you!

  • @denniscronin1112
    @denniscronin1112 Рік тому +1

    You have to ensure the heating is off before removing the screw?

  • @adham7402
    @adham7402 7 місяців тому +1

    There is electronic device on the pump (wilo) i dont know how to remove it

  • @mrbig4532
    @mrbig4532 9 місяців тому +1

    You want to make sure the pump is isolated before you take that screw out .

  • @Scriffbin
    @Scriffbin 9 місяців тому

    Please clarify this bit as the tool landed and blocked the word out "if you give it a sharp tap its (what?) the pump off"

  • @katemackenzy5296
    @katemackenzy5296 Рік тому

    Thanks for video. very clear. ok removed the front nut, turned the inside screw- action seems fine...so put it all back together...turned to heat mode...the pump casing itself is getting very hot, is this normal? I can feel vibration and assume water passing through...I have hot water fine...but I only have two large cast radiators on this system, I dont believe they have water in them...as bleed valve produce nothing, but both cold as stone...even though boiler has kicked in, pressure at 1.6...any advice?if I open the feed tap the pressure goes up but not going to the rads.?
    TIA combination boiler.

  • @rebeccafindlay9068
    @rebeccafindlay9068 3 роки тому +4

    Hi I’ve taken the lock off but water continuously pours out of the pump and is very hot, the internal part turns freely but when boiler is running the pump makes no noise. Can you offer advice?

  • @GayleGrantDocGrant
    @GayleGrantDocGrant 3 роки тому +5

    When you remove the center screw should this device be plugged in or not? Thanks!

    • @colin5064
      @colin5064 2 роки тому

      yes it should always be turned off before attempting this

  • @colin5064
    @colin5064 2 роки тому +1

    Yes you should point our electric to the boiler needs to be (switched off) before doing this.

  • @junaibnaek9489
    @junaibnaek9489 2 роки тому

    Thank you so much..sattle my problem

  • @Sul331988
    @Sul331988 Рік тому +1

    Where do you find this pump?
    I have an ideal logic combi boiler, but cannot find this part.

  • @fablan3308
    @fablan3308 2 роки тому +1

    Do you need to switch off power off to do that

  • @PatLoya
    @PatLoya 8 днів тому

    screw is stuck, any tips on how to loosen screw?

  • @fablan3308
    @fablan3308 2 роки тому +1

    Do you need to turn the water off
    Or heating system

  • @jonnie1512
    @jonnie1512 4 роки тому +2

    Further to this the downstairs radiators come on for a short period before going off but the hot water and upstairs radiators work as normal

    • @cymro9559
      @cymro9559 3 роки тому

      Same as me what's solution!

  • @liaqathussain3011
    @liaqathussain3011 Рік тому +1

    Hi.. My pump is seized ..IV brought a new head.. is that a simple fix or replacement if I did it myself?.

    • @daveLin104
      @daveLin104 Рік тому +1

      Hi did you do it yourself in the end ?

  • @BorgOvermind
    @BorgOvermind 2 роки тому +1

    If the pump does not work will you have only hot water or nothing at all (no heat, no hot water) ?

  • @lordfennris5121
    @lordfennris5121 4 роки тому

    thx our heating wasent working your banging the pump has it working thx agen.

  • @spicelife6338
    @spicelife6338 3 роки тому

    Thanks mate

  • @bofhvp
    @bofhvp Рік тому

    Done that and the pump moves freely.
    Still got 1/3 of the rads that are luke warm and the rest cold.
    What would be the next to check ?

    • @goodhomehacks9780
      @goodhomehacks9780  Рік тому +1

      check system pressure if sealed system, should be 1 bar minimum, check rads for air, if still no joy you will need to call in a plumber

  • @petersutton3054
    @petersutton3054 5 років тому +1

    Hi my pump has a lot of water coming out nonstop from bleed valve and it blows fuse in pcb when heating is on but works ok on just hot water do i need new pump?

    • @goodhomehacks9780
      @goodhomehacks9780  5 років тому

      Hi Peter
      Sounds like you need to call in a plumber.
      If you have gravity primaries without the need for pump this would explain why boiler works ok on hot water only

  • @exwhyz33
    @exwhyz33 3 роки тому +1

    when I run the bath, then after a minute or so the pump produces a clear whirring sound for 10-15 seconds before settling down. what could be causing this? is there an easy check/fix ?

    • @colin5064
      @colin5064 2 роки тому +2

      probably a build up of limescale on the pump impeller, needs dismantling and removal of scale.
      You also may need to top up the Fernox or other brand inhibitor in the central heating system to aid lubrication of this pump

  • @mertsamet2953
    @mertsamet2953 Рік тому

    hello . do we have to decreese boiler pressure to 0 while this operation ? thanks

    • @goodhomehacks9780
      @goodhomehacks9780  Рік тому +1

      You can do, but remember to increase pressure to 1 bar before you check pump is working

    • @mertsamet2953
      @mertsamet2953 Рік тому

      @@goodhomehacks9780 no please look at the 1:13 . pressure must be zero at this instant ???

  • @shmugarinsky
    @shmugarinsky 3 роки тому

    This trick got the pump/boiler working last week, but this week the pump seems to be overheating again. Is there anything else to do to tune up the pump?

  • @jonnie1512
    @jonnie1512 4 роки тому +1

    I’ve taken the locking but off but the water just constantly runs out when I do this. On your video you only have a small amount of water come out. Can you help?

    • @sarunassurvila7857
      @sarunassurvila7857 4 роки тому +1

      If it sprays water after undoing the plug that means the pump isn't working well and it needs to be changed soon.

    • @adzsyed2051
      @adzsyed2051 2 роки тому +1

      Hi, was this the case as mine is doing the same?

  • @mrcombiBedford
    @mrcombiBedford 4 місяці тому

    Bad advice, NEVER bang a pump or anything, do NOT remove👎 the VENTING screw while full of water, that's dangerous water damage PCB.

  • @stevetabzz8535
    @stevetabzz8535 4 роки тому

    Hi Jonnie every time I switch the hot water switch on it trips the electrics out. Plus when I’ve also undone the plug on the pump loads of water comes out could this be the problem

  • @fablan3308
    @fablan3308 2 роки тому

    My on spins but doesn't work

  • @radarwarrior5459
    @radarwarrior5459 Рік тому

    "Check heating pump"? There's two pumps... pump one is oil pump and pump two is water pump. Your video refers to a water pump.

  • @philtse115
    @philtse115 3 роки тому

    I can feel my pump vibrating and its very warm, even hot to the touch. I haven't unscrewed the large screw yet which ill do tomorrow and also unplug from the electrical socket.
    Is the pump suppose to be hot?

    • @andrejrockshox
      @andrejrockshox 10 місяців тому

      well it is pumping hot water, so...

  • @bradjammin
    @bradjammin 5 років тому

    Are you turning off the system before you remove the screw?

    • @goodhomehacks9780
      @goodhomehacks9780  5 років тому +2

      Hi Bradley
      No need to turn system off before you remove screw.
      After you have removed the large screw use a small electrical screwdriver to insert into shaft.
      If the pump is running you will feel it vibrating against the pump impeller as it spins so all good with pump.
      If the pump is stuck you will feel no vibration. You will then need to turn the impeller with a small slotted screwdriver to free off. When impeller is free the screwdriver will vibrate and pump will start to spin. Remove screwdriver.
      If then pump is badly stuck you may have to push hard on screwdriver to free off.
      Sometimes tapping gently with a hammer before you remove screw works so try this first.
      Hope this helps and all goes well

    • @bradjammin
      @bradjammin 5 років тому

      GoodHomeHacks no problem. Doing this at present but there is STACKS of water coming from the pump as I open it

    • @goodhomehacks9780
      @goodhomehacks9780  5 років тому +1

      Something is amiss here and impellor seems to be letting by. This can be because pump is working fine and not stuck?
      Shut system off and allow to cool. Check system pressure is no more than 1 bar when cold if sealed system(Combi boiler).
      Remove screw and check if impeller turns. Small amounts of water are normal.
      If problem persists and you cant free off pump and you have loads of water coming out then you will need to call a plumber to resolve.
      @@bradjammin

  • @bobbysuk
    @bobbysuk 2 роки тому

    This video shouldn’t be alowed and nobody should be removing the front boiler case if you are not gas safe registered.
    The boiler case is an important part of the combustion process and the seal around it must be re fitted correctly otherwise it could have deadly consequences

    • @Kurnazify
      @Kurnazify Рік тому

      stfunoob even a chimp could do this. we dont like getting scammed by repairmen.

    • @m1geo
      @m1geo Рік тому +2

      Oh, behave mate. Its a waterpump! 🙄

    • @bobbysuk
      @bobbysuk Рік тому

      @@m1geo I know it’s only a water pump he’s working on but how did he access it ?!
      Bottom line is unless your gas safe you won’t understand how important it is that the case is installed correctly!

    • @growinsane9123
      @growinsane9123 Рік тому

      @@bobbysuk In most combi systems these pumps are not even inside the boiler. I have a Gledhill Boilermate and there is no gas connection. Perhaps the presenter should have mentioned this but there are circumstances where you are not going to be going anywhere near gas.