WATER HEATER GAS VALVE REPLACEMENT

Поділитися
Вставка
  • Опубліковано 5 вер 2024
  • Water Heater Gas Valve assembly amzn.to/2WPId0f
    Make sure to purchase a replacement compatible with your existing gas valve. A service technician is recommended for the repair to ensure the gas supply line is leak free
    (As an Amazon Associate I earn from qualifying purchases)
    This reset will work with most gas water heaters. Whirlpool, A. O. Smith, Rheem, Bradford White, GE General Electric, ao smith etc.
    This should work with American water heaters, Rheem water heaters, A. O. Smith water heaters, and Bradford white water heaters

КОМЕНТАРІ • 66

  • @usborn1
    @usborn1 2 роки тому +8

    I just did this same job yesterday. I watched some videos just incase there might be something I forgot. One video showed me how to replace this without draining the entire tank. I am glad I watched it as the tank did not want to drain because of to much calcium build up. As long as nobody opens a faucet in the house it is very easy. Just like you did shout off the water to the tank, put a bucket under the drain and open it up. Some water will come out but then it will almost stop. There will be a vacuum in the take and you will be able to take off the valve and only loose about a half a cup of water. It was so easy I though some would have to go wrong but it did no, even though it was Fri. the 13th. The whole thing took about 30 min.

  • @neilbedajna8282
    @neilbedajna8282 2 роки тому +3

    The best instructional video in the entire youtube. Thank you.

  • @smarthome2660
    @smarthome2660 3 роки тому +4

    For this very reason is why I always install a water shut off on both the cold and the hot pipes. Having two water shut offs isolate the water heater from the rest of the house so you can still use water through out the house while doing maintenance on the water heater. It is helpful when you drain the sediments out of the heater once per year. Speaking of sediments, check the anode rod for deterioration every other year. This is one cause of sediments. If you wait too long to replace the anode rod, you might not be able to replace it and the water heater will soon fail. A build up of sediments is one cause of high temperature failure. Your water heater is slow to drain due to a build up of sediments and thus tripping the high limit sensor which makes the whole gas control valve fail.

  • @luishernandez5394
    @luishernandez5394 2 роки тому +3

    I’m and Hvac/t technician I changed one out for the first time by my self pretty easy common sense

  • @imagetf
    @imagetf 8 місяців тому +1

    Thank you so much! We followed every step of your instruction and got our unit back up and running.

  • @megavideoyoutube.2654
    @megavideoyoutube.2654 3 місяці тому

    This was Great really appreciate the step by step instruction. Very informative about the gas & water lines, also about purpose leak detector and pipe sealant. My son & I got our unit back up and running🙃

  • @philliphall5198
    @philliphall5198 10 місяців тому

    Very well explained and easy to understand how to change it out
    These valves don’t last very long eather, pretty cheap unit 😢😢😢

  • @richardrodriguez5846
    @richardrodriguez5846 Рік тому +1

    Thank you so much for your detailed instructions! I was able to change out old broken thermostat to a new one. I changed out my honeywell with a resideo brand. Same specs, different brand. I'm an electrician so plumbing isn't my strong point, but I do find lots of similarities. Your video still helps out till today, thankyou again!

    • @checkitout2468
      @checkitout2468  Рік тому

      You’re welcome. Thanks for the kind comment. 👍😎

  • @arifkharadi880
    @arifkharadi880 2 роки тому +2

    Thanks for the detailed instructions and all the cautions one of best vedeo on UA-cam

  • @ask43242flight
    @ask43242flight 2 роки тому +1

    Very nice tutorial. It seems the flex pipe is one-time usage.

  • @philliphall5198
    @philliphall5198 10 місяців тому

    I use a spray bottle and dawn dish soap and little water
    Works great

  • @melvinmcgregor2673
    @melvinmcgregor2673 6 місяців тому

    Nice video and very good explanation. The only missing component that was not shown is a sediment trap/drip leg. Could that be the reason your gas valve needed to be replaced?

  • @luv4macaws
    @luv4macaws 4 роки тому +2

    Thank you, my vent was partially plugged reducing the pilot flames ability to light the furnace.

  • @AlexA-vl1zx
    @AlexA-vl1zx 3 роки тому

    Awesome video. I appreciate all the little details like what you might have to wiggle, what should plumbers tape, etc. It helped me change mine out with confidence

  • @checkdacontract
    @checkdacontract Рік тому

    There's a nipple in between the gas valve and the a coupling that feeds into the gas shutoff valve. The flex gas line looks so much easier

  • @spekkio64
    @spekkio64 5 років тому +3

    amazing video and extremely detailed with a good reason. Thanks for saving me hundreds of dollars

  • @dh1270
    @dh1270 Рік тому +1

    Good job man. Simple and informative.

    • @checkitout2468
      @checkitout2468  Рік тому

      You’re welcome! Thank you for the kind comment!👍😎

  • @runwayray
    @runwayray 4 роки тому +4

    I need the guy to fix the guy on the guy

  • @terryholcomb9492
    @terryholcomb9492 4 роки тому +2

    I see you love the word GUY

  • @jfarinacci0329
    @jfarinacci0329 2 роки тому +1

    very good vid. thank you.

  • @BrimmyBeats
    @BrimmyBeats 16 днів тому

    Take a shot everytime he says this guy

  • @lorenzoalmanza4765
    @lorenzoalmanza4765 2 роки тому +1

    Muy interesante información 👍❤️❤️

  • @ManuelAlvarez-yj5bu
    @ManuelAlvarez-yj5bu Рік тому

    Very nice … gracias!

  • @doubletake2448
    @doubletake2448 5 місяців тому

    Unless not required by your state (which is unlikely), installing a gas valve with out a sediment trap is not up to code.

  • @brianbushay8283
    @brianbushay8283 2 роки тому +1

    I see two problems with your heater installation. Your flex gas line if legal in your jurisdiction should connect to the top of a tee with a drip leg on the bottom of the tee and you flex line should not have a dip in it that goes below the gas inlet. Your water supply lines are also a problem. The flex connectors you use have plastic inside that stainless steal mesh. You should not have anything that will melt within 18" of the top of the tank and keep 6" away from the flue

    • @tonymc3817
      @tonymc3817 2 роки тому

      Yeah that's the problem with these diy'ers. I'm always correcting their work too.

  • @bowtiedbigcat9484
    @bowtiedbigcat9484 4 роки тому

    My water heater was bought in 2016 I get no status light on my water heater. Rheem recommended to ship me the gas value replacement.

  • @davidvasquez2867
    @davidvasquez2867 3 роки тому

    My gas line connector(the adaptor between the gas hose and valve) was very tight due to pipe dope in the thread. I tried to unscrew it with force and broke the old gas valve where it connects to the water heater. Now I have to drill out the remainder of the connection. Don’t be like me and just go to Lowe’s and buy a new gas line connection to replace the one stick to the valve. Save yourself a big headache.

  • @m2luxuries718
    @m2luxuries718 3 роки тому

    Great video came in to use

  • @kevrobinson2000
    @kevrobinson2000 3 роки тому +1

    Amazing video! Thank you so much for taking the time to give detailed instructions! Is the 1/2" nipple to compression fitting 16:42 , is that a standard piece I can buy at Home Depot?

    • @AlexA-vl1zx
      @AlexA-vl1zx 3 роки тому

      Late response but in case others are wondering - yeah. I found a lot at Lowe’s

  • @kennethhoskisonsr9210
    @kennethhoskisonsr9210 Рік тому

    That drain valve is a ¼ turn open, closed. I did same thing

  • @svirgo1224
    @svirgo1224 3 роки тому

    thank you, it helped me a lot

  • @MistaFrisco
    @MistaFrisco Рік тому

    Does it matter if the model number is different from the the old control valve?

  • @slidn1
    @slidn1 2 роки тому

    the problem to start with was most likely the pilot tube connector was not tight enough and gas was leaking

  • @mrdeanv4414
    @mrdeanv4414 3 роки тому

    Great video and very informative....I'm looking for a burner assembly for a 40 gallon Reliance water heater m# 640 gort 300... I just replaced the old control valve wv8840b1109 with a WT8840B1000 control ... any ideas?

  • @kstevens77
    @kstevens77 3 роки тому

    Replaced mine after same type of leak follow a hard multi-day freeze down in Dallas. I cannot get the status light to blink and therefore cannot get pilot to light. Any guidance would be great.

  • @stephanefraga2599
    @stephanefraga2599 Рік тому

    Temperature can be increased by removing knob

  • @glober8
    @glober8 4 роки тому +1

    Hello!
    Does that small box uses a type of batery? For the green or red light to flash or be on.

    • @CWfist
      @CWfist 3 роки тому

      NO battery, It has an internal element (called Thermopile ) at the burner that catches the heat from the pilot flame and that heat generates a low voltage that feeds that light in the gas valve. Watch this video and it explains it well ua-cam.com/video/1VIvEqVbt14/v-deo.html

  • @daryl4083
    @daryl4083 2 роки тому

    the shot with the water coming out of the Honeywell box?
    there is nothing connected to the water, the pilot light, thermocoupler and the pilot spark.
    nat gas enters the honeywell.
    I think you may have water in your nat gas?

    • @checkitout2468
      @checkitout2468  2 роки тому

      There’s a probe on the back of the “box” that penetrates the tank.

  • @adambivins9409
    @adambivins9409 4 роки тому

    how long do you fill the tank for? Also, how long do you run the hot water in the sink?

  • @calvinbaxter172
    @calvinbaxter172 3 роки тому

    how to switch from natural gas tp propane

  • @Yukam1912
    @Yukam1912 5 років тому +1

    SO QUESTION: THIS STATUS LIGHT BLINK EVERY THIRD SECOND, THAT RELECTS THERMOPILE ERROR ACCORDING TO CHARD PROVIDED ABOVE,,
    ARE THESE TWO ISSUES, ARE INTERRELATED , OR THAT LEAKAGE CAUSIN THIS MALFUNCTION?

    • @michaelfinnegan4348
      @michaelfinnegan4348 5 років тому

      What does 7 blinks mean?

    • @Yukam1912
      @Yukam1912 5 років тому

      Michael Finnegan 7 blinks of red light
      According to chart provided

    • @JadedeaJade
      @JadedeaJade 5 років тому

      if it blinks once every 3 seconds then that means its working as normal. now if it blinks more than once, look at your guide.

    • @TheMrskydog
      @TheMrskydog 3 роки тому

      @@michaelfinnegan4348 7 blinks means gas valve bad. Replace with new unit.

  • @hopeforthefuturesg
    @hopeforthefuturesg 3 роки тому

    ida flooded my basement about 6 inches now I have no hot water and can't get the pilot to spark a light...I pulled the burner out and dried it off and been a day and still won't spark. what should be my next step..let it dry out more?

    • @JOENUPE
      @JOENUPE 3 роки тому

      Control box is most likely shot. Just finished replacing one in the Bronx. Control box was submerged.

    • @hopeforthefuturesg
      @hopeforthefuturesg 3 роки тому +1

      @@JOENUPE i only had about 6 to 7 inches..idont think it reached the control box..the burner area was soaked as I pulled it out though

    • @JOENUPE
      @JOENUPE 3 роки тому

      @@hopeforthefuturesg no worries….did you remove the bottom plate and check for spark?

  • @enzoamore9173
    @enzoamore9173 5 років тому +1

    That's why I always install a ball valve on the hot side so I get no back feed

  • @raycarr225
    @raycarr225 2 роки тому

    valve was stuck...tapped it around its case and boom! lit up. 25 years old! pilot was lit. so, not the thermocouple.

  • @michelgrenier1878
    @michelgrenier1878 2 роки тому

    This could be the wrong pipe dope , The pipe dope must be approved for Natural gas and Propane ;A home owner replaced a gas valve on his furnace , The house blew up ,and there were casualties in Ontario Canada , Law suits occurred , HVAC suppliers no longer sell to the public , Only to licensed contractors in Canada .

  • @davidwangeman11
    @davidwangeman11 5 років тому

    I have to do this. Pretty nervous

    • @checkitout2468
      @checkitout2468  5 років тому

      I would recommend having professional come out and do it for you.

    • @davidwangeman11
      @davidwangeman11 5 років тому

      @@checkitout2468 I think my friend and I can do it but I'd rather have someone come out and do it which is what I'm probably going to do

  • @laszlovass7326
    @laszlovass7326 2 роки тому

    I just had this same water leak. These valves are nothing but trouble, garbage.

  • @z14film31
    @z14film31 5 років тому +3

    Had to Fast forward the whole video Keep repeating the same things. To long for no reason