Well if you understand the circuit well you know "dead zones. I recommend shutting off the breakers as many of my viewers are beginners and that is the safest thing to do do
@@ThePunggolHandyMan sorry my bad. Realise it’s another light cable. Due to your tutorial, I fixed my first 2 gang broken switch. Thank you much. Keep up the good work
For a 2 gang 1 way smart switch where there is a Live, Neutral and two Load terminals, is the COM wire for the rest of the house inserted into the Neutral terminal of the smart switch?
My 3 gang switch has 1 com port but my new one has 3 com ports, 1 for each L1. I was told that I need to connect the com ports. What kind of wire should I use ? On online shopping I can see AWG ranging from 14 to 30. Thanks.
Different people have different preferences. Check out the latest video on my Facebook page to learn why! m.facebook.com/story.php?story_fbid=pfbid08ohT31Nc5Xsvk1yGc4sFuEEtqQUdPYU3Nuax7pmdGkymTzuW6d7N43vAeJSQz1TAl&id=100063622060836
Don't forget LOTO hehe. Anyway, any idea on how to convert concealed socket(new bto) to those protruding socket with casing? I'm thinking of creating additional power socket loop that runs externally like old hdbs.
Easy just mount the box over the existing hole and pass the wires through. You can even use the concealed screw mounts to attach the new box (drilling the box may be required.) Then use gap filler to fill up the remaining gaps!
This a great video bro to do.. tapping the existing conceal powerpoint to another new powerpoint either via trunking or conceal la......i just done with this project just become of my fish tank😂😂😂😂😂
Nah it depends on the silicone. It must be the printable kind. I usually use caulk. Check the link below. This one is says paintable on the tube amzn.to/3WtPdPz
@@ThePunggolHandyMan Hi, any recommendations for caulk that I can get in Singapore? I was doing research and all the caulk I come across are those in the large tubes that require the caulking gun. I'm only looking to seal up some light switches, so something small and compact would be good. Thanks!
Hi Kenneth I use this daily. Comes in a handy squeeze tube! Product Name: Selleys No More Gaps - Gap Filler Product Price: $9.5 Discount Price: $9.4 Product Link: c.lazada.sg/t/c.YkOs5b
My punggol home 2 gangs 1 way only have 3 wires (not 4) to connect 2 lights , is it possible. Gang 1: wire 1 to COM, wire 2 to the other slot. Gang2: daisy chain wire in one slot, wire 3 to other slot. Total only 3 wires : wire 1,2,3
Psps, can I check if the daisy chain wire can be slot into a N (neutral) slot? Cause the standard HDB 2 gang switch has L1 & L and L2 and L. But the new one I bought has L1 L2 L and N. Connecting the live and the daisy chain to L doesnt work
Hi I need help, I'm changing my kichine switch it is connected to my hood and light. It's a 2 Gang but not sure how many way. How to identify? I take a photo and show to the hardware shop person he also not sure! How I wish I could upload a photo here.
Thank you for producing such helpful video. I changed my broken switch today after watching this video.
Most welcome! I'm so glad it helps!
Only video that clearly related to what I was handling.... Smart switch😊 Thanks
great tip and a well-made video. you explained everything so that even i could understand... many thanks!
Thank you so much man for sharing this video, it is very helpful
thank you for this video... life savior. resolved issue with the bridge wire...~
Glad I could help! Leave me a like n subscribe!
Hi, i wish to understand how you determine that the toilet light wire is the daisy chain that supply to the rest of the house?
Hi check out this video for more information on how a Daisy Chain works
ua-cam.com/video/M8bib8PDHR4/v-deo.html
Well explained, Good job. Thanks Wang
Nice content. Do you know how electrician can work without turning off the circuit breaker? I never see them turn them off
Well if you understand the circuit well you know "dead zones. I recommend shutting off the breakers as many of my viewers are beginners and that is the safest thing to do do
Hey, appreciate your 2g1w tutorial ❤
Do you have 3g1w tutorial for viewing?
Hi, good stuff. But I have live cable and light wires. Then I see additional black wire. I am stubbed as to that. Earth cable? Thks
Wow I gotta see a picture
@@ThePunggolHandyMan sorry my bad. Realise it’s another light cable. Due to your tutorial, I fixed my first 2 gang broken switch. Thank you much. Keep up the good work
@@colinchong4187 thank you for the vote of confidence!
Thanks very useful
Thank you!
I assume that style neon tester is still legal in your country. You would get thrown off site in UK/Europe. Use a non-contact voltage test pen.
Yeah it's legal here
For a 2 gang 1 way smart switch where there is a Live, Neutral and two Load terminals, is the COM wire for the rest of the house inserted into the Neutral terminal of the smart switch?
Hi different smart switches have different wiring. Best ask your supplier
If you trun the second pole on. Will the yard 💡 and the toilet 💡 turn on?
No. If I turn the second switch on, only the yard light is turned on,
Thanks! Similar for 2g 2w light switch? I messed them up
Wow I have to do a video for 2g2w that's even trickier
great explanation. thanks
Thanks for the video!
My 3 gang switch has 1 com port but my new one has 3 com ports, 1 for each L1. I was told that I need to connect the com ports. What kind of wire should I use ? On online shopping I can see AWG ranging from 14 to 30. Thanks.
Just wondering, is there no law that say that BTO/HDB that electrical wiring must be with proper colour code? everything brown colour?
no earth wire?
what do u recommend for the cordless screw driver which is reliable?
Different people have different preferences. Check out the latest video on my Facebook page to learn why!
m.facebook.com/story.php?story_fbid=pfbid08ohT31Nc5Xsvk1yGc4sFuEEtqQUdPYU3Nuax7pmdGkymTzuW6d7N43vAeJSQz1TAl&id=100063622060836
My switch is as you described starts flickering and has a burning smell. Should I just re-wire or get a new switch? Thanks for the handy video.😊
Hi! You need a new switch!
The old switch will have the label for the wiring for live n netural?
Switches are usually live and load, light point is live and neutral. Depending on who installed it your wires may be labelled or unlabelled.
Well explained thanks.
Glad it was helpful!
Don't forget LOTO hehe. Anyway, any idea on how to convert concealed socket(new bto) to those protruding socket with casing? I'm thinking of creating additional power socket loop that runs externally like old hdbs.
Easy just mount the box over the existing hole and pass the wires through. You can even use the concealed screw mounts to attach the new box (drilling the box may be required.) Then use gap filler to fill up the remaining gaps!
You gave me an idea for a video
This a great video bro to do.. tapping the existing conceal powerpoint to another new powerpoint either via trunking or conceal la......i just done with this project just become of my fish tank😂😂😂😂😂
Perfect thanks
This video clear teaching
I'm so honoured you find it beneficial! Share it with your friends!
My light switch only 1 L. Can I connect 2 live wires together
Can attest to not putting silicone around switches. U can't paint over silicone lol. Anyway to paint over silicone?
Nah it depends on the silicone. It must be the printable kind. I usually use caulk. Check the link below. This one is says paintable on the tube
amzn.to/3WtPdPz
@@ThePunggolHandyMan Hi, any recommendations for caulk that I can get in Singapore? I was doing research and all the caulk I come across are those in the large tubes that require the caulking gun. I'm only looking to seal up some light switches, so something small and compact would be good. Thanks!
Hi Kenneth I use this daily. Comes in a handy squeeze tube!
Product Name: Selleys No More Gaps - Gap Filler
Product Price: $9.5
Discount Price: $9.4
Product Link: c.lazada.sg/t/c.YkOs5b
Hi do you know how to convert switch light to 3 pin plug?
Haha depends on your setup it might be possible, however there may not be any ground connection
@@ThePunggolHandyMan ahh i see ya i think mine no ground connection, but can it be modified ?
Yes it possible, I think its best you contact me via FB to discuss further
Good Stuff! Thanks!
Hi Bro. I have problem in connecting back my 2 gang switch controlling 1 light. Possible to guide me. Thank you.
2 gang or 2 way?
2 way with 2 gang switch.
My punggol home 2 gangs 1 way only have 3 wires (not 4) to connect 2 lights , is it possible. Gang 1: wire 1 to COM, wire 2 to the other slot. Gang2: daisy chain wire in one slot, wire 3 to other slot. Total only 3 wires : wire 1,2,3
Yes if it is 2 gang 1 way, having 3 wires is correct because that's the end of the chain
Psps, can I check if the daisy chain wire can be slot into a N (neutral) slot? Cause the standard HDB 2 gang switch has L1 & L and L2 and L. But the new one I bought has L1 L2 L and N. Connecting the live and the daisy chain to L doesnt work
Hi cam contact me via FB? I'll try to answered there
What if the fixtures i have got neutral coming out? Where does it go on the switch?
Is this HDB? Or maybe you're looking at a dual pole connection
Hi I need help, I'm changing my kichine switch it is connected to my hood and light. It's a 2 Gang but not sure how many way. How to identify? I take a photo and show to the hardware shop person he also not sure! How I wish I could upload a photo here.
Hi Aaron do contact me via fb I'm more than happy to assist!
What if we have two live wires on the two gang switch board, what to do?
Check out the video on house wiring and daisy chain That should explain heaps
If you have two live wire in the two gang board meaning you are connecting without looping common
Hi, live goes to com and not load right? My current set up is live to load and not com. Help😭
Live to com, load is light 😀
Nice Bather
What if you have two live wire
Meaning your light use different breaker/MCB. Hope this will help.😊
can show 1 ganger?
Great video broo....u got FB page bro so can follow.....
Yes it's the Punggol Handyman
What if there is two live wires
Have a watch, this video will explain
ua-cam.com/video/M8bib8PDHR4/v-deo.html
Not helpful... this is based overseas
Yup this was for the asian context and does not apply globally
This is Timothy from Africa. I am Electrician. Can you please send me your email
You may contact me over Facebook at the punggolhandyman
Power loud n clear🫡
What if you have two live wire
Nice Bather