Jeep EV Conversion - Regen Fault Kick on Full Pack Charge - FIXED

Поділитися
Вставка
  • Опубліковано 16 жов 2024
  • So, with this build using a NetGain Hyper9HV and the Orion 2 BMS, there was a condition that would force you to recycle (restart) the system to clear the fault.
    Conditon:
    If the Pack was fully charged and you had Regen enabled, if you were on throttle, all good, then fully off throttle to let it slow to 0 RPM, the regen would attempt to recharge the battery pack with Regen.
    Problem:
    The pack is full. So, CCL (Charge Control Limit as opposed to DCL, Discharge Control Limit) won't allow the Regen to put any more juice into the battery for obvious reasons.
    Solution:
    You have to shunt that extra voltage and not let the lower limit of the charge, say 5.5kw, to be the bottom. This is now done in the BMS settings (mostly).