TIA Portal: Why can I not access my PLC?! Here are the PROFINET basics!

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 60

  • @hegamurl7434
    @hegamurl7434  5 років тому +27

    I apologize for the short confusion in the middle... I have switched the PLC's and simply downloaded to the wrong one 😅

    • @mortenlund1418
      @mortenlund1418 5 років тому +3

      This is what makes your videos extra informative. Thanks for the upload.

    • @pavelyanchylenka8076
      @pavelyanchylenka8076 4 роки тому +1

      Hello, nice you chanel, very good information. send you mail maybe whatsAPP, maybe you help me

    • @marlordOfDoriath
      @marlordOfDoriath 4 роки тому +2

      Are you kidding? That's what made the video interesting... Drama in the middle and resolution.... Great.

    • @ahmadpoureskandari6127
      @ahmadpoureskandari6127 3 роки тому +2

      Dear Hegamurl you are very good and these are not important

  • @Facemix
    @Facemix 3 роки тому +1

    Hey Hegamurl, is it possible to like your videos two times??? What a legend you are! PLC legend, my friend!

  • @TheBiggerRPM
    @TheBiggerRPM 2 роки тому

    This video saved me after hours of trouble shooting! The ISO access part to assign IP address in particular. Thank you Hegamurl 😊

  • @armchairfreedomfighter
    @armchairfreedomfighter 5 років тому +5

    Many thanks for the video! Top man!

  • @framos9991
    @framos9991 Рік тому

    My favorite teacher ✌Thanks!

  • @davidpalmer963
    @davidpalmer963 11 місяців тому

    Very good info. Your videos are extremely helpful

  • @mohamedaboudaif8227
    @mohamedaboudaif8227 Рік тому

    Thank you for the great information you explored in here

  • @mohamedkerchich7506
    @mohamedkerchich7506 3 роки тому

    Hi Hegamul,
    I did manage in the past to download a program to the PLC even though it didn't have an IP address, and actually I have just done it now while watching your video which I found so beneficia.

  • @dan-olaliljenberg5637
    @dan-olaliljenberg5637 3 роки тому

    Love all your videos Phillipp! Also want to see a video on modbus TCP/ IP.... Thanks man!

  • @fvee
    @fvee Рік тому

    Am having issues with connecting to a new S7-1500 PLC. I guess with the example you have set in the video i will go try it and give you feedback. Thanks a lot

    • @kream770
      @kream770 9 місяців тому

      how did it go!

  • @armchairfreedomfighter
    @armchairfreedomfighter 5 років тому +5

    Philipp for president!

  • @berinderazvan7909
    @berinderazvan7909 5 років тому +1

    thanks for your wery well explained .Continue with the video.

  • @IK-qu9hw
    @IK-qu9hw 5 років тому +1

    Thank you for your video.

  • @martintrost815
    @martintrost815 4 роки тому

    Like your other videos, it was very informative. Thanks.

  • @emcee3120
    @emcee3120 4 роки тому

    Sir, please also make a video on Modbus communication (TCP & RTU)
    Thanks.

  • @nagugulbarga
    @nagugulbarga 4 місяці тому

    Is it possible to make video on CAN communication with s71200 using profinet to CAN gateway. Which is currently demanding in the automotive industry

  • @saadamine7000
    @saadamine7000 5 місяців тому

    Thanks you teacher

  • @raphaelm.marcalcampos6910
    @raphaelm.marcalcampos6910 3 роки тому

    Great videos! Thanks.

  • @DSimonJones
    @DSimonJones 2 роки тому

    WondebA !!!! Danke from wales:)

  • @saifrehman7413
    @saifrehman7413 4 роки тому

    Much respect

  • @fverboven
    @fverboven 3 роки тому

    Top! this is what i really needed :)

  • @salehaarooj
    @salehaarooj 2 роки тому

    Hello Hegamurl, first of all I just want to thank you for making such Informative videos on Siemens PLC. Secondly my question is, in the video @ 17:35 you tried to change the IP address Manually but it didn't work and you said once you download the IP then you can't change until reset but then later part you change the IP of One of the CPUs in Device Configuration. What is the difference if we change the IP address in Online Access "Functions" or in Device configuration? Thanks

  • @sourav_majumder
    @sourav_majumder 4 роки тому

    Thank You...

  • @seyedabolfazlmohamadi3794
    @seyedabolfazlmohamadi3794 Рік тому

    Hi. thanks to you for your good course.
    I cant connect to plcsim v13 sp2 and there is just an icon like plc in subfolder of plcsim in online access root with no name or any other information.
    would you help me please?

  • @deshabandhunayak320
    @deshabandhunayak320 5 років тому

    Please share a video on rack fault OB 86 with 317F PN/DP cpu.

  • @maheswaran9727
    @maheswaran9727 3 роки тому

    Share some details about serial communication

  • @pratheeshlalpradeep2159
    @pratheeshlalpradeep2159 3 роки тому

    Please do a video on sina_pos function blocks

  • @Mathis-ug5oh
    @Mathis-ug5oh 7 місяців тому

    I love you.

  • @davidpalmer963
    @davidpalmer963 9 місяців тому

    Hey Hegamurl, do you like the Rock Group "Blondie"?

  • @arielvalentino4339
    @arielvalentino4339 4 роки тому

    Hi Phillip, would you make video for S7 communication (usend urcv)?

  • @MrKarajo
    @MrKarajo 3 роки тому

    Great video but which interface must be configured? TCPIP or ISO?

  • @VIMBAITSIDE-by1fc
    @VIMBAITSIDE-by1fc 6 місяців тому

    all my online access are saying update accessible device l dont know what to do

  • @Sandman777-RTU
    @Sandman777-RTU 5 місяців тому

    Can anyone explain why is the first and second plc is 101 and 102? Thanks

  • @nicolasmavrocordatos3322
    @nicolasmavrocordatos3322 4 роки тому

    Could the issues that came up in the middle of the video be solved by changing the subnet mask?

  • @soufyandadoun5024
    @soufyandadoun5024 3 роки тому

    Thanks

  • @xdisceptionnuble6071
    @xdisceptionnuble6071 4 роки тому

    When i try to download to plc device it has a red background colour at the address task bar and i cant press load, how to fix this please?

  • @faiksoyalp2850
    @faiksoyalp2850 4 роки тому

    Thank you

  • @waqasakram3332
    @waqasakram3332 4 роки тому

    Hello guys...
    I am using my CP-343 attached in rack with CPU 300 as an "IO Module" over profinet protocol with CPU 1500. After configuration "Operating mode" I exported my GSD from CPU 300 and import into CPU 1500 project but still I am not able to go online with GSD because GSD "Online & Diagnostics" are shwoing wrong module information online and offline where module details are not available.
    Please help...

  • @djjackocomeon
    @djjackocomeon 4 роки тому

    Hi Phillip, I know I am not in the right area for this question but I don't know where else to contact you? I would like a tutorial on setting up a PC on my network that will run WinCC runtimea dn be able to control my PLC from the PC, just like a HMI.

  • @saedalhabbashi2790
    @saedalhabbashi2790 Рік тому

    Confusing and error -full video

  • @jahirsuja9211
    @jahirsuja9211 4 роки тому

    I am requesting you to make some videos regarding SINEMA.

  • @leafarrrrr
    @leafarrrrr 5 років тому

    I'm using simulation, i tried to configure 2 cpus, which were assinged with a different IP address automaticlly from TIA. When i tired to assing an ip address, all the section was grey so i couldn't configure anything. But i can still access all the functions in the "online access" for both the cpus, although they are in a different networks. Do you know what is the reason for that?
    Btw you are great! thanks for your videos and time!

  • @AnilYadav-wp6gs
    @AnilYadav-wp6gs 2 роки тому

    ("an interface is not available for an online connection to the configured access node.)" sir please help me to solve this prblm

  • @sarahlabidi6558
    @sarahlabidi6558 Рік тому

    Thank you Hegamurl

  • @sandropernerstorfer
    @sandropernerstorfer 3 роки тому

    Danke dir hat sehr geholfen

  • @nircola
    @nircola 3 роки тому

    Hi
    there is a scenario that you must create subnet to assign ip ?
    thanks in advanced

  • @Himanshu-bu8hc
    @Himanshu-bu8hc 4 роки тому

    Please describe abt the hardware datatypes

  • @lego12682
    @lego12682 Рік тому

    Why is my tia portal not connecting?!?!

  • @saeed2tube
    @saeed2tube 5 років тому

    Hi.
    Could you please use software in your pc so it can zoom on screen? (Sometimes is hard to read text specially by mobile phone)

    • @hegamurl7434
      @hegamurl7434  5 років тому +1

      Can try to use a lower resolution, that might help. I will test it and if it still looks okay then maybe use it

    • @JustIce-zv8pk
      @JustIce-zv8pk 5 років тому

      @@hegamurl7434 Please don't change resolution. Quality of your videos is very good, and lowering resolution will just blur text even more.

  • @joymohadani9366
    @joymohadani9366 4 роки тому

    Not understood at all.. How u connect two plc and there network connection.

    • @hegamurl7434
      @hegamurl7434  4 роки тому

      Here is my complete playlist about communication... there is a LOT more than just this video (and even more than in my playlist)
      ua-cam.com/play/PLtGimRyb0S0iXquTkCKS-ANPPr925ntO9.html