How to Add a Structured VFD Control to your TIA Portal PLC Application (4 Step Tutorial)

Поділитися
Вставка
  • Опубліковано 23 лип 2024
  • ►► Grab My FREE GUIDE on How to Drastically Improve the Structure of your TIA PLC Applications Right Here:
    www.plcskilltree.com/free-gui...
    ►► Learn Advanced TIA Portal PLC and HMI Programming functions and features in the PREMIUM edition of my TIA Portal - All Basics Pack:
    www.plcskilltree.com/bundles/...
    ►► Get 15% discount on all courses and bundles by using coupon code TIAPORTAL15OFF at checkout.
    Getting started with TIA Portal has never been so easy.
    Let me help you become a confident and structured TIA programmer TODAY.
    VIDEO CONTENT
    00:00 - Intro
    01:32 - Adding a VFD to your Profinet Network
    06:58 - Setting up the Data Communication
    15:18 - Create Structured VFD Inputs and Outputs
    25:50 - Build a Standardised VFD Control Block
    33:10 - Let's Wrap it Up
    -------------------------------------------------------------------------
    This video contains a step-by-step guide for implementing a structured VFD control in your own TIA PLC applications - available NOW in the Premium edition of my TIA Portal - All Basics Pack training bundle.
    The All Basics Pack training bundle includes:
    ► 8+ hours of PLC and HMI training videos
    ► 40+ supporting documents
    ► 1 downloadable TIA Portal sample project (PLC+HMI application)
    ► 1 Certificate of completion (with unique ID) for each course
    ► 21-day free trial of TIA Portal
    ► 30-day money back guarantee
    ► Lifetime access
    ► Instructor support
    The Premium Content includes:
    ► 1 downloadable Premium TIA sample project (PLC+HMI application)
    ► 91-page premium guide
    ► All Premium application graphics in .SVG format
    -------------------------------------------------------------------------
    ► Thanks for watching!
    ► Got a comment, suggestion or a request🤔? ⬇️ Use the space below! ⬇️
    ► Subscribe to my channel 🙏to hear about new videos first! Don't forget to hit that notification 🔔!
    ► I am a freelance system integrator - check out my services at www.rsautomation.eu
    #tiaportal #plc #hmi #s7 #tutorial
  • Навчання та стиль

КОМЕНТАРІ • 76

  • @PLCskilltree
    @PLCskilltree  8 місяців тому +4

    ►► Grab My FREE GUIDE Featuring 5 easy steps to Drastically Improve the Structure of your TIA PLC Applications:
    www.plcskilltree.com/free-guide-optin

  • @shawnbraganza9020
    @shawnbraganza9020 4 місяці тому +1

    Great video. Thank you

  • @candiahung3208
    @candiahung3208 9 місяців тому +2

    Great video! Send to my team members! Look forward for the advance one or the safety one!

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      Thanks Candia, appreciate the support!

  • @jasonwattsae
    @jasonwattsae 9 місяців тому +1

    Great video! Very straightforward explanation of how to use UDTs! I love seeing more people trying to help others unlock the power of well designed FBs!

  • @gilbert-plclearningchannel7304
    @gilbert-plclearningchannel7304 9 місяців тому +1

    this is very advance programming , it 's very organize because he's using UDT,,god bless sir.

  • @chidoziriiroh9329
    @chidoziriiroh9329 6 місяців тому +2

    Thanks a lot Hans

  • @Bigmallone
    @Bigmallone 9 місяців тому +1

    Very helpful video

  • @warasali7875
    @warasali7875 4 місяці тому +1

    Very good video 💯❤ your teaching way are so deferent. Thank you

    • @PLCskilltree
      @PLCskilltree  4 місяці тому

      How is it different? Would be nice to know 👍🏻

  • @teknosistem
    @teknosistem 14 днів тому +1

    Thank you sir.

  • @akhtarshamim2424
    @akhtarshamim2424 7 місяців тому

    Thanks Sir very very nice video upload thanks 👍👍👍👍👍

  • @automationwithmukeshdayama6100
    @automationwithmukeshdayama6100 9 місяців тому +2

    Nice, pls make video on report generation

  • @arefrrafiee7546
    @arefrrafiee7546 9 місяців тому +2

    Thanks a lot for this great video. I have just one question: what is the word swapping in Siemens?

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      It’s not word swapping, it’s byte swapping - within a word. A word has 2 bytes - 0 and 1. You just swap those.

  • @nitishkumar-le6un
    @nitishkumar-le6un 4 місяці тому +1

    Very well explained.... Great work Patron ... Keep it up .... Could you please check for ATV0320 drive profibus communication with Siemens plc.

    • @PLCskilltree
      @PLCskilltree  4 місяці тому

      Thanks, sorry no experience with ATV0320

  • @dogucosgun8659
    @dogucosgun8659 7 місяців тому +1

    Your courses are amazing. Are you planning to make more advanced new courses on your website?

    • @PLCskilltree
      @PLCskilltree  7 місяців тому +1

      Yes I am working on a smaller course about advanced structuring. Thanks for your support!

  • @chrisredfield8698
    @chrisredfield8698 3 місяці тому +1

    I appreciate the time and effort you've put into this. Pls keep pumping these kind of lessons as they are gold to us.
    But i have a QUESTION in terms of "byte swapping", would keeping the bits as you declared in the video instead of bit15 to bit8 then bit7 to bit0 affect the control of the vfd or not ?

    • @PLCskilltree
      @PLCskilltree  3 місяці тому +1

      Hi Chris,
      Thanks for your nice words, happy to hear you get something out of these videos.
      If you do not do the byte swapping, then your VFD control will not work (because your bits 0 to 7 will be switched with 8 to 15). Was that your questions?

    • @chrisredfield8698
      @chrisredfield8698 3 місяці тому +1

      @@PLCskilltree Yes sir you've answered my question

  • @ouahoudizakaria1668
    @ouahoudizakaria1668 5 місяців тому +1

    good

  • @user-hf1wj8bl9x
    @user-hf1wj8bl9x 3 місяці тому +1

    Hello hans. Do you also teach in your hmi program about display event (not alarm) . And also using OB of plc?

    • @PLCskilltree
      @PLCskilltree  3 місяці тому

      There’s a complete lecture in my HMI course dedicated to system diagnostics. I’m only using OB1 in my courses but I might update my premium content with interrupt OBs.

  • @SergioGarciaU
    @SergioGarciaU 8 місяців тому +2

    Thanks for the video. Just one question: Why don't you create a UDT for this block interface like you did for the others? (with Cmd, Stat, Cfg, Flt)

    • @PLCskilltree
      @PLCskilltree  8 місяців тому +2

      Good question Sergio. I usually create a UDT with Sts, Cmd, Cfg etc… structures for the parent module - in this example it would be the Refill Module.
      Here I have chosen only to map the command and status of the telegram for the lower level VFD control block, where generated faults are part of the Flt structure of the higher level Refill block.
      But this comes all down to preference. Yes you could create a complete Sts, Cmd, Flt, Par,… structure as well for the VFD but I prefer to keep that larger structure only for the parent module (e.g. refill).

    • @SergioGarciaU
      @SergioGarciaU 8 місяців тому +3

      @@PLCskilltree It makes sense since the number of interface signals to the block is low. Thanks a lot for the answer.

  • @user-hf1wj8bl9x
    @user-hf1wj8bl9x 3 місяці тому +1

    Hi. Your videos are awesome. Im interested in your courses but i want to know what are the knowledge i will learn in the course. I already bought courses before but i didn't expect what i need. Thanks Hans

    • @PLCskilltree
      @PLCskilltree  3 місяці тому +1

      Thanks.
      You will learn how to build structured TIA PLC and HMI applications from scratch, not just loose concepts or isolated examples - complete and fully functional applications.
      If you go to my website www.plcskilltree.com, you can read much more about each course or bundle and there are plenty of testimonials from people who took my courses. That should give you a good idea.

  • @HectorRodriguez-si3yr
    @HectorRodriguez-si3yr 6 місяців тому +2

    Hi, what if i want to run backwars the motor? how can i do it using tahat telegram? wich flag should i use?

    • @PLCskilltree
      @PLCskilltree  6 місяців тому +1

      You’ll have to set bit 11 “setpoint inversion” of the controlword to “1”.
      My course (check the description below the video) comes with a sample application that shows you the exact logic first controlling the drive (including running the drive in the opposite direction)

  • @mehdikeyvani6179
    @mehdikeyvani6179 Місяць тому +1

    thanks for your advanced tutorial , as a question? do you have tutorial about free telegram in your premium course?

    • @PLCskilltree
      @PLCskilltree  Місяць тому

      The premium course uses the same telegram as the video. Why would you want to use a free telegram?

  • @eisasatari3777
    @eisasatari3777 4 місяці тому +2

    HI ,
    There is no TELEGRAM option in my added drive properties 🤔
    can you guide me ?
    thanks in advance

    • @PLCskilltree
      @PLCskilltree  4 місяці тому

      Which drive did you add? Which plc are you using?

  • @mohammedrezk8072
    @mohammedrezk8072 9 місяців тому +2

    it's great to get this chance enhancing my plc structured code but it seems the guide sign up page is not good to send every time i got "This value seems to be invalid." error for all my emails trials

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      I have many sign ups each day, so the sign up page seems to work. Maybe try again another day.

    • @mohammedrezk8072
      @mohammedrezk8072 9 місяців тому

      it is working now flawlessly Many thanks@@PLCskilltree

  • @chrisredfield8698
    @chrisredfield8698 2 місяці тому

    Hi Hans chris again 😊. I've followed your steps and i created the "Standard Vfd Control FB", i've never thought it would be this easy especially the abuse of UDTs. But i wanted to ask about COMMISSIONING (inserting the motor data etc..), do you do it as a second step or do you follow another method ?
    Thanks in advance 🙏

    • @PLCskilltree
      @PLCskilltree  2 місяці тому

      Hi Chris,
      My video about creating the software is the first step, before the commissioning. Then during commissioning you will need to setup the VFD - give it an IP address, configuring the motor data like voltage, current, rpm, power etc....
      I typically get the motor data from the data plate on the motor (picture with mobil phone) and I use the setup on the BOP screen of the VFD to set the applicable parameters to the correct values. I also write down the motor data for each motor in my project worksheet, just so I have a backup.

    • @chrisredfield8698
      @chrisredfield8698 2 місяці тому +1

      1- I apologize for skipping ahead of the video i'am just a bit excited😋
      2- It seems that my Noob brain and its short term memory had a misunderstanding. I thought that "VFD control FB + commissioning" was enough and forgot about adjusting the VFD's
      Parameters through it's BOP/AOP so it can be controlled by the PLC through PN like in our example.
      Signature
      NOOB_Lvl_ONE_THOUSAND

  • @Huyautomation2901
    @Huyautomation2901 9 місяців тому +2

    So as the video,i cant read Current ,Voltage from VFDs ?

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +2

      In this tutorial I am using standard telegram 1 for data communication between VFD and PLC. If you select a different telegram, you can get current and voltage status. Remember to update the UDTs and control block as well with the additional status information.

    • @Huyautomation2901
      @Huyautomation2901 9 місяців тому

      @@PLCskilltree Can you recommend the best Telegram for control Plc and VFDs ?

  • @SelmaneAmraoui
    @SelmaneAmraoui 9 місяців тому +2

    How to create an HMI to control the speed after completing all these steps ?

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      That part is described in my premium training bundle, check the description below the video.

  • @vijaipackiri238
    @vijaipackiri238 Місяць тому +1

    Dear friend... some of the blocks are already created in previously. So Need to create all by this session video itself. Then only easy understand this all

    • @PLCskilltree
      @PLCskilltree  Місяць тому

      Thanks for your feedback. If you want to know how the program was made from scratch, please go and check out my courses in the description.

  • @ColinDickie
    @ColinDickie Місяць тому +1

    Can this be simplified using Technology Objects?

    • @PLCskilltree
      @PLCskilltree  Місяць тому +1

      As far as I know, technology object are for motion axes = servo axes, not for VFDs.

    • @ColinDickie
      @ColinDickie Місяць тому +1

      It can be done with Technology Objects as I've done it. However, in my instance it was still using Telegram 1, and it resulted in over simplifying everything. I will be using your method from now on, which I hope will give me more control. Thank you!

  • @mr.write1433
    @mr.write1433 9 днів тому +1

    i dont have the simatic drive ? how will i see it ?

    • @PLCskilltree
      @PLCskilltree  9 днів тому

      Not sure what you mean

    • @mr.write1433
      @mr.write1433 7 днів тому +1

      @@PLCskilltree I already fix the problem. My version of TIA portal has no sinamics driver so i download it separately on their website.

  • @amarnathnsw9392
    @amarnathnsw9392 4 місяці тому +1

    Pls sir make video on profibus communication

    • @PLCskilltree
      @PLCskilltree  4 місяці тому +1

      Profibus is kind of an outdated technology, I prefer to create videos on newer technologies

    • @amarnathnsw9392
      @amarnathnsw9392 4 місяці тому +1

      @@PLCskilltree ok but in India most place we are used sir

    • @PLCskilltree
      @PLCskilltree  4 місяці тому +1

      @@amarnathnsw9392 I understand

  • @abdevilliers6555
    @abdevilliers6555 5 місяців тому +1

    Hello Sir, Can you send me the backup please.

    • @PLCskilltree
      @PLCskilltree  5 місяців тому

      The complete application is available in my premium bundle. Check out the description below this video for more info 👍🏻

  • @mr.write1433
    @mr.write1433 9 днів тому +1

    Tia portal integration to vfd kinda complicated…

    • @PLCskilltree
      @PLCskilltree  9 днів тому

      It’s not the only way to communicate, but it’s a structured way

    • @mr.write1433
      @mr.write1433 7 днів тому +1

      @@PLCskilltree Your videos are helpful. There's no video on the details of the function blocks though ?

    • @PLCskilltree
      @PLCskilltree  7 днів тому

      @@mr.write1433that information is in the course itself - link in the description below the video.

  • @angelrivera3192
    @angelrivera3192 3 місяці тому +1

    It’s to complex and there are a existing functions for this in the library of the software

    • @PLCskilltree
      @PLCskilltree  3 місяці тому

      I disagree about it being complex. It’s actually straightforward with simple steps. If you’re used to building structures for your plc applications then this example is relatively easy.
      Can you send me a link to the library that you are mentioning?

    • @nicholasfender869
      @nicholasfender869 20 годин тому

      Sina_speed or Sina_Para ?

  • @Huyautomation2901
    @Huyautomation2901 9 місяців тому +2

    May I ask you,sir? Is that method used for all VFDs those have Profinet interface or just for Siemens VFDs?

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      I have used these steps as well for e.g. Danfoss frequency converts. The steps are the same, just different telegrams for the data communication between vfd and plc.

    • @Huyautomation2901
      @Huyautomation2901 9 місяців тому +2

      @@PLCskilltree so it depends on the different manufacturers ? And how they define Control Word?

    • @PLCskilltree
      @PLCskilltree  9 місяців тому +1

      @@Huyautomation2901 yes, but 4 steps for structuring stay the same. I would always build UDTs that mirror the communication and I always build a standard control block.

    • @Huyautomation2901
      @Huyautomation2901 9 місяців тому +2

      @@PLCskilltree thank u for your reply.I hope u will make more video about PLC