How to install drainage pipes with the correct fall? OHOB Training Academy

Поділитися
Вставка
  • Опубліковано 16 січ 2025

КОМЕНТАРІ • 44

  • @balamusadanso7074
    @balamusadanso7074 10 місяців тому +5

    Well articulated, precisely done

  • @marctronson6696
    @marctronson6696 Рік тому +16

    Once you have measured the fall from.one end to the other, just pull a string line on the top of the pipes from collar to collar to make sure the fall is consistent. Easier and quicker tha n trying to guess with a spirit level

  • @bakker071
    @bakker071 Рік тому +5

    So what happens when the ground sags? Will the gravel stay in place?

    • @drainfast-uk
      @drainfast-uk  Рік тому +3

      Our recommendation is to surround all buried pipes with pea shingle or similar aggregate to avoid puncturing or crushing them when compacting. When the soil settles over time or the ground is loaded in some other way (traffic, building...). The pea shingle will "flow" around the pipe and fill any voids underneath better than many other options

    • @bakker071
      @bakker071 Рік тому

      @@drainfast-uk thanks, I’m a bit biased. We have such lovely ground that everything has to be piled.

  • @cristhianlopez8726
    @cristhianlopez8726 Рік тому +3

    Omg that was an amazing job editing.

    • @drainfast-uk
      @drainfast-uk  Рік тому +1

      You did a great job Christhian, thanks again

  • @ronnoman61
    @ronnoman61 6 днів тому

    Anybody alive out there, that can remember laying salt glazed pipes with tar based tow and cement and sand ? Then building the inspection chambers in brick. Plastic pipes make it as easy as falling off a log and why not? who wants to go back to those days. I'm so glad to be long retired from all that.

  • @leonmorris5602
    @leonmorris5602 2 місяці тому +3

    You Gotta invest in a grading level us aussies use, trusting brickwork to measure from is the most rookie thing iv ever seen at least use a laser

    • @Dleweyy
      @Dleweyy Місяць тому +1

      Exactly what I was thinking, at least get the laser out 😂

    • @leonmorris5602
      @leonmorris5602 Місяць тому

      @@Dleweyybro wtf are they doing in the uk 😂 that shit is embarrassing

  • @roybatty4687
    @roybatty4687 Рік тому

    So you want to lay it at a slope but check it's flat with a level?

    • @drainfast-uk
      @drainfast-uk  Рік тому +1

      There is more than one way to use a level. In this case as described in the video, the bubble is not central but used to make sure the fall is consistent.

    • @Tom-Lahaye
      @Tom-Lahaye 7 місяців тому

      Many levels have multiple lines on them, when the bubble is between the center two lines then it's level.
      But on the level he used (and I use) there are 2 or more lines outside of the center ones, the outermost line normally correspondents with the 1:40 fall, when the bubble touches that line you're okay.

  • @RavinderKumar-r9k
    @RavinderKumar-r9k Рік тому +1

    Don't you think slope is too much. I use 2 inches for 6 metre pipe

    • @drainfast-uk
      @drainfast-uk  Рік тому +2

      We understand that every building site may be different and people may have a prefrence or diffrent methods that work as effective. This video is mainly for a broad demonstration purposes.

    • @RavinderKumar-r9k
      @RavinderKumar-r9k Рік тому +1

      @@drainfast-ukSir , I thought for a moment, I am wrongly laying the pipes

    • @drainfast-uk
      @drainfast-uk  Рік тому +1

      @@RavinderKumar-r9k Not at all, methods can be different depending on various factors and preferences. 😊

    • @peeb2896
      @peeb2896 7 місяців тому +1

      "Don't you think slope is too much. I use 2 inches for 6 metre pipe" No wonder we are all confused...LOL! Inches and Metres....LOL!

  • @andrewthomson3165
    @andrewthomson3165 3 місяці тому

    1 inch in forty inch full on sewer pipes always has been. I've installed them forty years never been called back for a blockage.

  • @l0I0I0I0
    @l0I0I0I0 Рік тому +1

    Why does the pipe need the flexability? You stated at the elbow to place a material to prevent the concrete from sticking to the pipe.

    • @drainfast-uk
      @drainfast-uk  Рік тому +1

      The pipe needs some flexibility in case there is slight ground movement, otherwise pipes could crack. Regarding concrete sticking to the pipe - the polythene or fibre board is to stop the concrete adhering to the building structure.

    • @l0I0I0I0
      @l0I0I0I0 Рік тому +1

      @@drainfast-uk Thank you, that's very helpful. Fiberboard to keep the concrete From sticking to the stricture? Is it not part of the foundation? Guess I assumed you would be pouring a slab?

    • @unda25
      @unda25 11 місяців тому +1

      also if you block it with some waist like cemenet or pplatering ,you can replace only one section you dont need to brake all the ground floor or basement , + is standar 600 mm movemnt BS

    • @l0I0I0I0
      @l0I0I0I0 11 місяців тому

      TY. I understood some of that. Im a diy.

  • @steveandrandibuell9212
    @steveandrandibuell9212 3 місяці тому

    Steve

  • @hanshichen8167
    @hanshichen8167 9 місяців тому +1

    should make slope from base then lay the pipe

    • @drainfast-uk
      @drainfast-uk  9 місяців тому

      Preferences can differ depending on the groundworker, all methods can vary. If you get the same result from the practice you've been taught then there is no wrong way.

  • @Boxingfanatic-fb8zg
    @Boxingfanatic-fb8zg Рік тому

    Isn't it Better practice to use mf elbows and pipe with collars. So the male end of elbow can go into the collar end of pipe and so on.. less chance of getting a leak.. the was you've piped that up the rubber seal is under stress from passing water.

    • @drainfast-uk
      @drainfast-uk  Рік тому +1

      It might be better practice but the method demonstrated is widley used across the industry, passes inspection and does not put the rubber seal under stress.

    • @Boxingfanatic-fb8zg
      @Boxingfanatic-fb8zg Рік тому +1

      @@drainfast-uk it's definitely got more chance of leaking fact

    • @roybatty4687
      @roybatty4687 Рік тому +1

      So you want to lay it at a slope but check it's flat with a level?

  • @vigalway
    @vigalway 6 місяців тому

    If some inspector passes this ….he doesn’t know what he is at either .
    Don’t be said by this video .

    • @drainfast-uk
      @drainfast-uk  6 місяців тому

      What specifically do you object to?

  • @user-qd6iq7jp7m
    @user-qd6iq7jp7m 9 місяців тому

    Is this a joke

    • @drainfast-uk
      @drainfast-uk  8 місяців тому +7

      No, but this is: what kind of bird works in the construction industry? A crane.

  • @user-qd6iq7jp7m
    @user-qd6iq7jp7m 9 місяців тому

    No you set a Lazer set fall in the Lazer do it right these lads haven't a clue

    • @drainfast-uk
      @drainfast-uk  8 місяців тому +1

      Both options can work fine depending on the job at hand.

    • @jimmyboimazarti1234
      @jimmyboimazarti1234 5 місяців тому +2

      lol what you onabout you don’t need laser for internal drainage 😂