Air Handler Heat Strips Not Working, Fan Blower Won't Turn On! Common Problems!

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • In this HVAC Training Video, I show the Common Problems on an Air Handler with Strip Heating! I Show Troubleshooting Techniques on Multiple Components! Diagnosis can be Performed with the Power Off to the Air Handler or with the High Current Loads Disconnected Prior to Turning the Power on for Safety. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
    Tools Used In The Video
    UEI DL489 Multimeter: amzn.to/47Fod5n
    Alligator Jumpers- amzn.to/2PxqJXn
    Magnet Jumpers- amzn.to/2PyKPQZ
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our Related Videos
    • Air Handler with Elect...
    • ECM Multi-Speed Blower...
    • WHY CAPACITORS FAIL in...
    • TOP 5 CONTACTOR Troubl...
    • HEAT SEQUENCER Operati...
    • Air Handler Blower FAN...
    • How an Air Handler & H...
    • Air Handler Fan Delay ...
    • Heat Pump Thermostat W...
    • How an Air Handler & H...
    • Air Handler Control Bo...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
    All Our Educational Products on Our Site: www.acservicet...
    All Our Educational Products on Amazon: amzn.to/48pDd82
    Mini Split Book and E-Book on Our Site- www.acservicet...
    Mini Split Paperback on Amazon- amzn.to/3ytHJSs
    Mini Split Paperback on TruTech Tools- www.trutechtoo...
    Refrigerant Charging Book and E-Book: www.acservicet...
    Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Our HVACR Online Resources!
    Our HVAC Calculators: www.acservicet...
    Our Newest Articles: www.acservicet...
    Try our HVAC/R Quizzes! www.acservicet...
    Our Other Resources: www.acservicet...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Tools Used in Our Videos!
    Tool Links on Our Site: www.acservicet...
    Our Tool List on Amazon: www.amazon.com...
    Support the Channel by purchasing tools through TruTech Tools!
    Use this link www.trutechtoo...
    Save 8% at checkout using code "acservicetech"
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Follow Us On Our Social Media & Podcasting Channels!
    Patreon: / acservicetech
    Facebook: / acservicetech
    Instagram: / acservicetech
    X: / acservicetech
    LinkedIn: / ac-service-tech-llc
    Tiktok: / acservicetech
    Spotify: open.spotify.c...
    Apple Podcasts: podcasts.apple...
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    #hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #fanblower #stripheating #heating #circuitboard #sequencer
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

КОМЕНТАРІ • 108

  • @treywilson4310
    @treywilson4310 Рік тому +14

    Ima a new tech fresh outta school. This is the best channel out there

    • @MaMa-qh4dy
      @MaMa-qh4dy Рік тому +2

      You got that right!!!! And you made an excellent career choice because the young'ins are not interested in the trades like in the old days. It's a supply and demand economy, and you will do great by being great!.

    • @Clasped003
      @Clasped003 Рік тому +1

      A former pro technician here. You are correct. Craig and HVAC School and Ty Branaman are the most important videos out there. Literally priceless knowledge. It doesn't mean that anybody can just come up and wrench on this equipment though. Stuff happens irl that you need pro training to understand and deal with.

    • @ebenezerservices6363
      @ebenezerservices6363 3 місяці тому

      Excellent choice, the more you like it the more enjoyable it becomes and the reward it's really good!

    • @scottieholland6486
      @scottieholland6486 3 місяці тому

      So when breaker is on it should read 24 amps correct? And that should feed to the relay

  • @edilsonserafim4784
    @edilsonserafim4784 Рік тому +10

    One of the best HVAC instructor ever

  • @joshschumacher7984
    @joshschumacher7984 Рік тому +43

    Been doing this for awhile and some air handlers are a nightmare to troubleshoot. No room in some of those cabinets

    • @EastDallasKicks
      @EastDallasKicks Рік тому +5

      Think I was in a controlled lab environment AKA school and they had Lennox and carrier, the Lennox seemed like it was built to pop you. I have little lady hands and still kept shocking my self on some sequencer spade connector

    • @EastDallasKicks
      @EastDallasKicks Рік тому +4

      Was the only way to get to the limit and heat strips

    • @Begrateful2024
      @Begrateful2024 Рік тому +9

      Facts seems as if the engineering gets worse instead of better. Like why would you put the sequencers , relays limits etc. Directly behind the circuit breaker lol.

    • @EastDallasKicks
      @EastDallasKicks Рік тому +1

      @@Begrateful2024 scary I like the fuse links those they don’t hurt as bad but that mf sequencer damn

    • @HVACRTECH-83
      @HVACRTECH-83 Рік тому +1

      @Devonte Baker ya aaon puts drives directly in front of relays and fuses on some model configurations. I hate it and it's actually very unsafe to work on them

  • @erep4537
    @erep4537 Рік тому +5

    Ive been in the trade since 1987 and have taught alot of beginners. I have to say that these videos are very imformative and I will recommend them to my newbies

    • @aridematos3555
      @aridematos3555 Рік тому

      When does everything start to click? I've been an apprentice for 5 months and it still seems very complicated for me.

  • @roelfuentes6157
    @roelfuentes6157 Рік тому +16

    Only been in the field for about a year and a half, honestly these electric heat strips (in all electric and heat pumps) always gave me trouble. This video is great information for beginners like myself and hopefully a refresher for the seasoned techs.

    • @dariuswalters3696
      @dariuswalters3696 Рік тому

      Fr been in the trade about the same amount I’ll take straight ac and gas over a heat pump every time

  • @jerrypagitt
    @jerrypagitt 7 місяців тому +2

    Absolutely an excellent and informational video. He covers 100% of what might be wrong.
    Again, a professional video that any novice can understand as well as the professional.

  • @deanmartin1966
    @deanmartin1966 Рік тому +5

    Great explanation of an air handler. Thanks for sharing.

  • @ubaldosoto7591
    @ubaldosoto7591 9 місяців тому +2

    Wonderful video for older heat pumps. Exactly what I was looking for.

  • @KharmenSense
    @KharmenSense 7 місяців тому

    Been watching several channels, you're is by far my favorite. Thanks for taking the time to spread the knowledge.

  • @ahmaderfanfaizi5024
    @ahmaderfanfaizi5024 5 місяців тому

    Very helpful and educational video , thanks for making such videos, and it really helps new technicians in the field

    • @acservicetechchannel
      @acservicetechchannel  5 місяців тому

      Thank you for watching! I'm glad you found my videos helpful!!

  • @baileybroton4800
    @baileybroton4800 Рік тому +2

    I’m starting hvac/r certification in February so I’m studying as much as I can before I get there, as I’m the only girl enrolled so I hope to keep up 😁

    • @Clasped003
      @Clasped003 Рік тому +2

      Gender has no distinction in the trade. Put as much effort into learning and being a good student, and always remember to treat fellow tradespeople with respect. Good luck, and remember that above all else, electrical knowledge will always put you above the rest. I can never underestimate how important the electrical knowledge is.

    • @baileybroton4800
      @baileybroton4800 Рік тому

      @@Clasped003 I was talking about the entering physicality of it with large units cause I’m going for commercial but yes I agree

  • @Geetr469
    @Geetr469 9 місяців тому +2

    Great video. You're a good teacher 👍

  • @chriswigent9150
    @chriswigent9150 Рік тому +2

    Thank you for all your training and advice. You have helped me quite a few times. I've been in this field for a couple years, and still having trouble understanding the old carrier electric furnace 40AQ030. I've fixed one that was worked on by several hvac guys , I've put it back to original equipment and wiring and still having difficulty. Carrier has upgraded a 230v fan motor but with a little bit different wiring .

  • @Alex-jo2oi
    @Alex-jo2oi Рік тому +3

    Awesome video. Very precise and descriptive. These help out a lot!!

  • @Edgarallen666
    @Edgarallen666 Рік тому

    Im fairly new to the trade and i live in south texas about 30 mins from the border and its barely getting cold so i dont have alot of experience with heat sequencers and this helped me out alot and i enjoy watching your videos, thank you so much sir!

  • @markm0000
    @markm0000 Рік тому

    Your videos are really good I’m learning many things that I wouldn’t have with trial and error.

  • @Hvacnc
    @Hvacnc Рік тому +1

    I always wondered how those small square ac to dc things worked. Thanks. Hardly ever see them

  • @sonGOKU._.
    @sonGOKU._. Рік тому +1

    I learn so much from this video ❤

  • @Farm_fab
    @Farm_fab Рік тому +1

    You mentioned thermostat wiring done wrong. I was on a commercial job site that the apprentices wired the temporary power GFCIs wrong at the shop, and kept tripping breakers when plugging anything into them. I'm not an electrician, but I do know polarity on AC power.
    At work, they have a sign above the cart for green cones used when servicing MCC panels for the arc zone, and among other things, it says that they are only to be used by "electrictians". I mentioned that to one of the mechanics there, and they said that they now know why the cones weren't being used. No one in the employ of the company has that title.
    I told the mechanic that this must be referring to some professional that is both a magician and works with electric. What a typo.😀

  • @jrpritchard1622
    @jrpritchard1622 Рік тому

    thanks for training advice very helpful when our hvac tech is out or on vacation i have to fill your videos have help me

  • @stevencossaboon3237
    @stevencossaboon3237 Рік тому +2

    Great video Craig. Thank you!

  • @darius1988
    @darius1988 Рік тому +1

    What an ancient ventilation unit :)

  • @user-fk4fm7qe1e
    @user-fk4fm7qe1e 11 місяців тому

    Im J Hernandez im lerning alot with the videos they are very helpful thank you for it

  • @pizzle1011
    @pizzle1011 Рік тому

    Great video! Don't have many air handlers up here in the Chicago area. Ran into one and one if your previous videos helped

  • @markscott4159
    @markscott4159 Рік тому +1

    Can you explain why for some components it's better to test resistance rather then just continuity? I know for some components a resistance test gives you the value you need to verify its working properly but with other components like fuses continuity gives you that answer with an audible beep or silence. I guess what I asking is what components test better with resistance and what components test best with resistance?

  • @aaronfox5808
    @aaronfox5808 3 місяці тому

    Great info and Video

  • @user-qf7ed8tl7f
    @user-qf7ed8tl7f 11 місяців тому

    Thank you so much for your video and very good explanation.

  • @dahdahforsanful
    @dahdahforsanful 9 місяців тому

    Thank you Bro , I have one unit i check all wiring are ok , the proplem is fan is running but the heater not working , when i shut off the fan the heater work

  • @bobbybrown8926
    @bobbybrown8926 7 місяців тому

    great video and explanation of these components.

  • @marcusdarnell3348
    @marcusdarnell3348 Рік тому

    Great video! I assume the reason why you used the rectifier was because that relay operates off of DC voltage

  • @g.culpepper7134
    @g.culpepper7134 Рік тому

    Great video!! Extremely thorough 😊

  • @chiplaurn8175
    @chiplaurn8175 Рік тому +1

    Can you please do a residential Aquatherm (firstco) combo ac cool/ hydronic heat. If you haven’t already.
    Thanks for the great vids!!

  • @markm0000
    @markm0000 Рік тому

    It’s also good to measure the low voltage input side of the relay coil for excessive resistance. That can cause intermittent issues.

  • @Sylvio15
    @Sylvio15 8 місяців тому

    This video is helpful

  • @carlsummers
    @carlsummers Рік тому

    Thank you for such great educational information!!

  • @harveywholesales9226
    @harveywholesales9226 7 місяців тому

    best explainner

  • @hinojosa552
    @hinojosa552 11 місяців тому

    Hi, you didn't create a book for the heating electric element and relays ?, on how they are powered, I seen your video, excellent, I would like yo buy your book on the electric heating, already bought the air conditioning book

  • @rocker8692
    @rocker8692 Рік тому

    Craig is the man

  • @mickthomas5469
    @mickthomas5469 8 місяців тому

    Great video - thanks for sharing 👍

  • @riverratfishing
    @riverratfishing Рік тому

    Fantastic video. Very helpful as always.

  • @povoljan13
    @povoljan13 8 місяців тому

    done, rewatch if needed.

  • @MsFishingdog
    @MsFishingdog Рік тому +1

    Great video

  • @fakku6356
    @fakku6356 Рік тому

    Thank you for your advice its really helpful thank you thank you thank you I think that I might be close to have my own company 😆😆

  • @APHVAC0913
    @APHVAC0913 Рік тому +1

    Great video 👍

  • @arnelarcedo132
    @arnelarcedo132 6 місяців тому

    Hi, where can I get the 24 volts temp. power supply tester that is attached to the transformer? tnx in advance

  • @mariolopez1
    @mariolopez1 10 місяців тому

    Hi i been following your videos and i have a question about the common wire .how it works? what it does ?why the system doesn't work without it. Thanks

  • @robertmunguia250
    @robertmunguia250 Рік тому

    That’s a neat tester!

  • @Yourengineeringstandpt
    @Yourengineeringstandpt 9 місяців тому

    Can also do a continuity test thermal limit swirh correct

  • @douglas747wct
    @douglas747wct Рік тому

    Hi Craig, great training and videos. I purchased your book and got a lot out of that too. However, I have a problem that is bewildering and hoping for some advice from you. Tempstar FCX6000C AH with PSC fan motor that won't turn off. It is not equipped with a Sequencer but has an Overtemp Limit switch that isn't tripped. HP unit is TCH260AKA1 with demand defrost board. Pulled TStat, no joy. Checked 24V wires for shorts and continuity to Tstat and HP. All ok. Checked signals to pins on AH Fan Control Board and discovered Y from HP has ~18V on it continuously in relation to C terminal. With all signal wires disconnected except for R, C and Y wires from HP, the AH fan turns on - removing Y from AH Y terminal causes fan to turn off after normal delay. I don't know if that voltage is what the demand defrost board normally sends to AH during defrost cycle to turn AH fan on. So the question is, should I suspect Demand Defrost board on HP or Fan control board on AH? I loath throwing parts at anything. I will check the defrost cycle test function and note if the unit functions normally. I'll also check the condenser coil defrost sensor. Your help is greatly appreciated.

  • @eman3208
    @eman3208 Рік тому

    Another great video! Thanks!

  • @Jurornumber5
    @Jurornumber5 4 місяці тому

    What costs more, the parts or paying the tech to test and measure all of these parts?

  • @depv343
    @depv343 9 місяців тому

    I have a lennox system where the transformer in the air handler trips every time heat is called. The system comes on fine with ac and fan only but when it calls for heat the transformer trips pretty much immediately. Any thoughts what it could be or what i should check first? I appreciate any help in advance as winter is coming 🥶 and the family needs the heater.

  • @NorCal-refrigeration
    @NorCal-refrigeration Рік тому +2

    Good stuff 🤘⚡️🤘✨✨✨

    • @acservicetechchannel
      @acservicetechchannel  Рік тому +4

      Well Dave, you encouraged me to write a minsplut book roughly two years ago. Its now done and coming out in Jan! Thanks for your encouragement!

    • @NorCal-refrigeration
      @NorCal-refrigeration Рік тому +1

      @@acservicetechchannel I need a copy. Just went to vrv training and still don’t know how to fix them 😂😂😂😂

    • @whitesheatingairappliancer7101
      @whitesheatingairappliancer7101 Рік тому

      I will be buying the new book. Thanks for everything.

  • @hugoguevara3864
    @hugoguevara3864 Рік тому

    Very helpful thanks you

  • @curtisroy6369
    @curtisroy6369 11 місяців тому

    Was that heat kit flipped to match the specified air flow direction? I only ask since the lettering on all the components is upside-down. Is this common practice so that heat kits can be used on both up and down draft air handlers?

  • @chrisdeanndavison3626
    @chrisdeanndavison3626 Рік тому

    About the DC relays. Johnson Controls / UPG used 28v coil DC relays WITHOUT a rectifier in some of their air handlers around the 2010s. They were sending 24v AC to the relay coil. Can someone explain why (and for that matter how AC voltage works on a DC coil)?

  • @mrgreen9086
    @mrgreen9086 8 місяців тому

    What could be the problem if you have an electric furnace and oncall for heat the heat strips turn up but the blower fan which is controlled by fan relay does not.
    Fan only comes on if you turn the thermostat fan in the on position but not auto when calling for heat

  • @Hvacmaniac97
    @Hvacmaniac97 7 місяців тому

    Sequencer is just another contactor, i am enlightened 😅

  • @zahkiyyah
    @zahkiyyah 7 місяців тому

    Can a heating element be added to an air handler?

  • @ilovenythismuchilovenewyor5801

    hey Craig when you make your own testing set up like w a transformer . and have an inline fuse set up ... what size fuse do you use w that ? i want to make my own lil trouble shooting set up .. I picked up a 10/30 output transformer w a 110v input .. I added a plug to it abd 24v t stat wire w that online fuse holder but wasn't sure what's besr fuses to use for trouble shooting 24 v components.. is. a 3 am fuse good or what do you recommend... also I will be ordering your new book soon on the mini splits

  • @GotchaplumberGotchahvac
    @GotchaplumberGotchahvac 9 місяців тому

    .1 resistance for thermal fuse

  • @cassandraclements3636
    @cassandraclements3636 10 місяців тому

    Why my auxiliary heat coming on and its not cold enough outside

  • @johnp7390
    @johnp7390 Рік тому

    Hey, you only have to remove 1 wire on each component to check the fuses and hi-temp limit switches!! Why potentially loosen more spade connectors and create an intermittent that wasn't there originally than necessary?!?

    • @ParabellumX
      @ParabellumX Рік тому +2

      He could've done it for any number of reasons.
      He could've done it because he gets slightly nervous when recording his self.
      He could've done it because he has obsessive compulsive disorder (OCD), and everything has to be done in certain multiples, etc.
      It is insignificant to question one who is demonstrating something with the sole purpose of educating others, just so as long as the principle itself is understood.

  • @jesuscastillo1083
    @jesuscastillo1083 Рік тому

    What’s the difference between continuity .and ohms

  • @paulcharpentier1241
    @paulcharpentier1241 Рік тому

    Can you put a video up on how to make, or where to get, a transformer tester?

    • @whitesheatingairappliancer7101
      @whitesheatingairappliancer7101 Рік тому +1

      I'll just use your multimeter set the voltage AC disconnect your low voltage leads from the Transformer and put your probes on those connectors with the unit powered up you should read 24 plus volts ac. You can also do a continuity test with no voltage and the wires disconnected from the Transformer to see if the windings are broken internally.

  • @sheltonhood4428
    @sheltonhood4428 Рік тому +1

    Basic using OHM'S Law

  • @steepndeep615
    @steepndeep615 Рік тому

    Always check strip heater to ground

  • @shooter2843
    @shooter2843 Рік тому

    Where does the test transformer get its high voltage from?

  • @Gametight601
    @Gametight601 Рік тому

    Question! Does a 6 pin General purpose relay supply the strips with 24 volts? The unit does not have a board. I'm trying to trace a short down and it's difficult. Im getting 24 volts on every thermostat wire but the heat wires. The heat strips have a board which is CNT06195. I've changed it, but I'm still not getting the voltage I need to the heat wire. Before I changed the board, the heat strips would cycle on and off with just 13 volts. Now that I've changed the board with CNT06194 nothing comes on in heat mode , now I'm getting 16 volts. Part of the heat strips would stay on for 7 seconds and go off. Help I'm puzzled!!!! This is a trane. GAM2A0c48s41sba. Thanks

  • @SalahDambo-gb6cs
    @SalahDambo-gb6cs 9 місяців тому

    I don't see a problem with taking money, otherwise you can do a lot،If it is through legitimate methods, it works

  • @iceesrule75
    @iceesrule75 Рік тому

    Question?.. when you are checking ohms you are ✔️ getting continuity?

    • @chrisdeanndavison3626
      @chrisdeanndavison3626 Рік тому

      Hope this helps. Continuity, as in a closed circuit, should read 0.0 ohms (or close to it). If the ohm reading is much higher, as in 0.5, first check your meter's reading by just touching the two test leads together. If you still have a reading like 0.5, correct the problem with your meter. If your meter reads 0.0 lead to lead, but the component reads higher, it can be pitting on the contacts of the component, or just a poor connection of your test leads to the component.

  • @juliomoreno5370
    @juliomoreno5370 7 місяців тому

    I have a contactor instead of sequencer

  • @andrewmcdonald4519
    @andrewmcdonald4519 Рік тому

    Change the batteries In your meter

  • @Dontbeweakvato
    @Dontbeweakvato Рік тому

    This education is very important to brush up our knowledge. But hopefully the death warning will prevent unknowledgeable people from trying this... Homeowners and such.
    One wrong move and bam, your life is over. I work on these, at times, like I'm working with live ammo or bombs 😂

  • @pascualangulo1
    @pascualangulo1 Рік тому

    Super 👍

  • @Turfgreenpro
    @Turfgreenpro 8 місяців тому

    Your multimeter it’s very complicated I don’t understand it. You should have a common meter on your instructional videos so we can see where to set our meters and what you are talking about. What option is electrical resistance on my meter??🤷‍♂️🤷‍♂️

  • @saulzain1957
    @saulzain1957 Рік тому

    What do you do if it's a 2 stage heatpump package and the 10kw heat strip is not working?

    • @jkbrown5496
      @jkbrown5496 Рік тому

      The only impact of a heat pump on the electric heat strips is that the defrost board should energize W to run the electric strips during defrost. My heat pump got wired with the W2 on an input terminal on the defrost board instead of the output so wasn't being energized.

  • @djaudioxtc02
    @djaudioxtc02 10 місяців тому

    It gets even worse when you have the communicating kind and the AVC thinks heat relays are closed when they are open and because of that it locks out the AC😂 Talk about scratching your head.

  • @jasonrhoades9270
    @jasonrhoades9270 Рік тому +1

    Yea tell the world our trade for free.

    • @jesuscastillo1083
      @jesuscastillo1083 Рік тому

      He wants the people buy his books , l don’t think . He is doing it for free,

    • @coolramone
      @coolramone Рік тому +1

      Most people don’t have the time, or the interest, or the mechanical or electrical ability to do this. They would rather watch movies or music videos or play games or sports or spend time with family or work at their jobs. Everyday I go to work I pass the fitness center and there are 50 cars in the parking lot.

  • @sherwinalvarez7365
    @sherwinalvarez7365 Рік тому

    Great video