All About Lights | How to Install a Pendant Light | This Old House

Поділитися
Вставка
  • Опубліковано 9 лют 2025
  • This Old House host Kevin O'Connor discovers the proper way to install ceiling-mounted light fixtures. (See below for a shopping list and tools.)
    SUBSCRIBE to This Old House: bit.ly/Subscrib...
    Shopping List for How to Install a Pendant Light:
    nonmetallic electrical cable, for wiring new fixtures and dimmer switch
    pancake electrical box"], for attaching new pendant fixture to ceiling
    dimmer switch"], for operating new fixtures
    three-gang switch box"], for housing the new dimmer and two existing wall switches
    Tools for How to Install a Pendant Light:
    screwdriver, for removing and tightening screws
    pry bar, for removing old switch box
    cordless drill, for drilling holes and driving screws
    electrical-box hole saw, used to cut holes in ceiling for pancake boxes
    drywall saw, for enlarging hole in wall for new switch box
    plumb bob, used to transfer fixture locations from countertop to ceiling
    fish tape, used to pull cable through wall
    caulking gun and fireproof caulk, for sealing hole bored in top wall plate
    About This Old House TV:
    This Old House is the No. 1 multimedia home enthusiast brand, offering trusted information and expert advice through award-winning television, a highly regarded magazine, and an information-driven website. This Old House and Ask This Old House are produced by This Old House Ventures, LLC and are presented on PBS by WETA Washington, DC.
    Follow This Old House and Ask This Old House:
    Facebook: bit.ly/ThisOldH...
    Twitter: bit.ly/ThisOldH...
    bit.ly/AskTOHTw...
    Pinterest: bit.ly/ThisOldH...
    Instagram: bit.ly/ThisOldH...
    bit.ly/AskTOHIG
    Tumblr: bit.ly/ThisOldH...
    For more on This Old House and Ask This Old House, visit us at: bit.ly/ThisOldH...
    All About Lights | How to Install a Pendant Light | This Old House
    / thisoldhouse

КОМЕНТАРІ • 121

  • @thomasmagda4580
    @thomasmagda4580 4 роки тому +13

    This has to be the easiest case scenario. How about without attic access and perfect mounting points?

  • @heroknaderi
    @heroknaderi 4 роки тому +3

    Very incredible I as well retrofit new work boxes as old work. Very helpful 😎👍

    • @christophereaton4694
      @christophereaton4694 4 роки тому

      Don't let the inspector see it.
      Can't legally run screws through the box unless it's designed for them.
      But, but, but....
      The Evenrued principal.

  • @Maxid1
    @Maxid1 10 років тому +95

    Another best case scenario job. The common answer to "What's upstairs." is some combination of, two angry cage fighters, 15 badgers, a lice filled flea farm and Chucky.

    • @JoeOklahoma
      @JoeOklahoma 7 років тому +2

      Lol'd at this, but when I saw "and Chucky" I lost it.
      About to move into my own home soon... hoping it's a best case. But then, I dig the Child's Play series and would totally be down for a Good Guy doll up there.

    • @muhammadsultani6078
      @muhammadsultani6078 7 років тому

      Maxid1 .

    • @MamaJade1
      @MamaJade1 2 роки тому

      Lmao

    • @davidparker9676
      @davidparker9676 2 місяці тому

      You forgot the family of angry rabid raccoons.

  • @jacobmyer7481
    @jacobmyer7481 4 роки тому +24

    Looks like Joe Exotic is doing well

  • @x2malandy
    @x2malandy 4 роки тому +2

    Open attic, nice.

  • @andyneipert2527
    @andyneipert2527 2 роки тому

    I like the lights he poot in

  • @merlonglighting4810
    @merlonglighting4810 2 роки тому

    Thanks for your share .

  • @davidfelton5648
    @davidfelton5648 2 роки тому

    Awesome video it was done correctly

  • @RobertLeBlancPhoto
    @RobertLeBlancPhoto 5 років тому +6

    Easy when you have an open attic. ;)

  • @PSNCraCkBaBy13
    @PSNCraCkBaBy13 4 роки тому +2

    2:40 that shepherd hook 😳👀😬

  • @Wannagobackto1980
    @Wannagobackto1980 5 років тому +9

    Putting 2 14/2's in a pancake is illegal. But I cant say I havent done it. Sometimes you get in a pinch and have no choice. Overload the cubic inches.

    • @GlitchedPepsi
      @GlitchedPepsi 5 років тому +1

      Davey28car not illegal everywhere

    • @denislamarche4656
      @denislamarche4656 4 роки тому

      Definitly against cec

    • @Nick-bh1fy
      @Nick-bh1fy 4 роки тому

      @@denislamarche4656 1000% 😂

    • @mr.g937
      @mr.g937 3 роки тому

      @@GlitchedPepsi Where isn't it illegal?

    • @oriannahernandez8219
      @oriannahernandez8219 8 місяців тому

      Agreee!! The wires and wire nuts could barley fit and I thought he was a licenced electrician

  • @anshugarg2727
    @anshugarg2727 3 роки тому

    Perfect

  • @jgroenveld1268
    @jgroenveld1268 4 роки тому +7

    Definitely not to code. You needed to apply the peanut butter BEFORE Jelly to the bread.

  • @YeseniaMariee
    @YeseniaMariee 4 роки тому +3

    how much would you say cost, to have done by an electrician

  • @mcarroll598
    @mcarroll598 4 роки тому +2

    Why wouldn’t this guy get a 3 gang plastic old work box for the switches?! Would be a lot better install.

  • @manuelsalgado8510
    @manuelsalgado8510 5 років тому +1

    I have 1 light in my kitchen and want to add 3 pendant lights . Can I use the same switch?

    • @RobertLeBlancPhoto
      @RobertLeBlancPhoto 5 років тому +1

      Sure. The circuit is simple. Parallel the hot wire for each additional light to a hot wire going to the load side of the switch, and parallel the neutral of each additional light to a neutral wire that's tied into the neutral of that circuit. If your circuit is grounded, tie in the ground wires as well.
      I recommend using fixtures that have dimmable LEDs and use an LED compatible dimming switch.

  • @Ariztid
    @Ariztid 3 роки тому +3

    She should've worried about getting new cabinets and counter tops before getting these installed.

  • @wyldebill4178
    @wyldebill4178 2 роки тому +1

    Wiring by Joe Exotic

  • @NinoValleyTv
    @NinoValleyTv 7 років тому +12

    I LOVE HOW THEY DONT SHOW YOU THE LITTLE PROBLEMS THEY RUN INTO...I.E. FIRE BLOCKING WHEN RUNNING WIRE IN THE WALL...SCREWING THE BOX INTO THE STUD WITH A SCREW AT A SLANT SO YOUR BOX ENDS UP CROOKED AS DO YOUR OUTLETS AND COVER PLATE....C'MON

    • @spencerwyche2552
      @spencerwyche2552 4 роки тому +2

      They never show things like that,that's why DIY'ers screw up there houses and end up calling us,real electricians.

  • @Dredpath1
    @Dredpath1 7 років тому +9

    Ok well if I’m correct, that box is no longer UL listed because he drilled through the box into the stud. He also cut off those 45 degree tabs for the nails. He should have used an old work box.

    • @VolpeInCalze
      @VolpeInCalze 5 років тому +1

      He should have went for an old work box with the tabs that flip out. Would have also been more secure and less floppy

    • @EVGSTORE
      @EVGSTORE 4 роки тому

      he cant use the nail tabs without cutting off more wall. It worked for the situation.

  • @星海音乐
    @星海音乐 8 років тому

    Where did you find the electrical box which is very shallow? Most of the boxes are very thick and if they are installed under the wood just like you did, the box will be pop out of the ceiling. So they have to nail it beside the wood which is not as good as beneath it. Where I can find the shallow electrical box? Thanks!

    • @donl1410
      @donl1410 8 років тому +3

      Pancake or ceiling boxes. The big box stores or hardware stores.

  • @meicealways5842
    @meicealways5842 4 роки тому

    I have questions i need answered
    My new home is not prewired for pendants...if you could give me an average price of how much it costs to install the lights of the home isn’t prewired for pendant....my lights will be about $100 a light..may you just estimate cost of labor and cost of it not being pre wired for the lights

    • @slappadabass3290
      @slappadabass3290 3 роки тому

      😂😂😂

    • @meicealways5842
      @meicealways5842 3 роки тому

      @@slappadabass3290 u laughin but it’s already compete lol
      Go look at the videos 💁🏽‍♀️💁🏽‍♀️

    • @slappadabass3290
      @slappadabass3290 3 роки тому

      You were asking TOH to give you an estimate 😂😂

    • @meicealways5842
      @meicealways5842 3 роки тому

      @@slappadabass3290 Chile anyway ….

  • @altecdarpa21
    @altecdarpa21 10 років тому

    if that outlet next to the switch is that close to the sink should it not be GFI?

    • @boris9305
      @boris9305 8 років тому

      +altecdarpa21 It's most likely a split receptacle and I have never seen a split GFI. So you would have to make it 2 switches each a GFI. Anyways the electrical was most likely done before the GFI code was instituted, and it is not retroactive.

    • @ColinBeirneSYR
      @ColinBeirneSYR 7 років тому

      Yes

    • @steveloux4709
      @steveloux4709 3 роки тому

      All receptacles serving counter surfaces in the kitchen must be GFCI protected, as well as the dishwasher circuit.

    • @davidparker9676
      @davidparker9676 2 місяці тому

      A regular outlet can be GFCI protected by the most upstream outlet being a GFI or having the entire circuit on a GFCI breaker in the panel.

  • @sever427
    @sever427 3 роки тому

    Ohhhh so that's how you use a plumb bob#chiggycheck

  • @pattremper8539
    @pattremper8539 8 років тому +27

    That's not code. You can't put screws through the box should have used a 3 gang old work box

    • @kleung347
      @kleung347 8 років тому +2

      if you look closely at the 3 gang box he used, all he did was take a 3 gang new work box and cut the brackets off of it.

    • @donl1410
      @donl1410 8 років тому +2

      I don't think the sheetrock srews are likely to become energized

    • @ericwotton2046
      @ericwotton2046 6 років тому

      If the screws are in the back 1/4 of the box it's okay or if it's a listed box with built in screws (smart box makes some) this guy didn't have an old work box so he hacked off the wings of a new work box.

    • @justincaver4958
      @justincaver4958 6 років тому

      That is to code.

    • @lilkid8486
      @lilkid8486 6 років тому +3

      This is definitely not code compliant. Once he cut the brackets off and screwed through the box, he voided the UL listing.

  • @colinhealey6244
    @colinhealey6244 7 років тому +3

    5:39

  • @MattBruns
    @MattBruns 9 років тому

    Is the red wire a 2nd hot wire?

    • @Dredpath1
      @Dredpath1 7 років тому +1

      it's acting as a switch leg

  • @TNtoolman
    @TNtoolman 10 років тому +31

    The electrician's ear rings clash with his outfit...

    • @Chuck59ish
      @Chuck59ish 10 років тому +9

      That's how he tests foe live wires, he just hooks on each earring.

    • @hubomama
      @hubomama 5 років тому

      Porsche924Tim is

  • @anne-marielynnsettano3245
    @anne-marielynnsettano3245 7 років тому

    How long should it take

    • @DavidLucBelanger
      @DavidLucBelanger 6 років тому +1

      About an hour if you don't stop working and everything goes according to plan, but if not maybe 2h-3h.

  • @Dredpath1
    @Dredpath1 7 років тому +5

    Did anybody else notice that he used 14/2 on a circuit that has 12/2? i hope thats not a 20A circuit because 14AWG wire is not rated for 20A.

    • @MIW_Renegade
      @MIW_Renegade 7 років тому

      It’s a light the wire probably came from a 20 amp circuit somewhere else like the outlet next to it the lights not gonna draw 20 Amps it’s gonna draw less that 5 amps

    • @RedBullishTrading
      @RedBullishTrading 6 років тому

      Safeman4202 technically it is rated for it(via the table) but they have a special code for small wires and that’s where they don’t allow it. For some reason....

    • @RedBullishTrading
      @RedBullishTrading 6 років тому

      SomeRandomGuyWithAChannelOnUA-cam that doesn’t mean it’s ok

    • @x2malandy
      @x2malandy 4 роки тому

      I did notice that. I figured they wanted to make it a "combo light and heater". Ha

    • @adammorgan9304
      @adammorgan9304 2 роки тому

      #14 thhn is rated at 25 amps but has overcurrent protection limitations

  • @theoneevans7790
    @theoneevans7790 4 роки тому

    I never seen this video ether too

  • @Bendc1970A1
    @Bendc1970A1 5 років тому +1

    What would have happened if there didn't happen to be a ceiling joist to screw the pendant mounts into? My luck i'd plumb bob up to the ceiling and there would just be drywall there.

    • @RoastBeefSandwich
      @RoastBeefSandwich 4 роки тому +2

      Use an old work light fixture box, those won't hold a fan but will be plenty for a pendant light.

    • @JimDean002
      @JimDean002 2 роки тому +1

      Use a fan bracket. It's basically a threaded rod that wedges into the ceiling joist on either side and once it's there you clamp the ceiling box to it. Installed probably they'll hold anything you want to hang on it

  • @pappabob29
    @pappabob29 10 років тому +2

    looking at the K.O. spacing on those pancake boxes, they sure look like 3 1/4" pancake boxes. Those are only acceptable as a "end of the line" outlet (one romex only) because of their conductor fill capacity. Even than, # 12 overfills the box but it's commonly overlooked. Two romex's in each pancake "overfills" the boxes even with #14 romex. Also, did all three boxes land on a ceiling joist?? Why not move them over 1 1/2" and use a standard 1 1/2" deep box or use a junction box in the attic with a single romex to each pancake box???

    • @nbarges
      @nbarges 9 років тому

      Pappa Bob Thanks for adding this comment, now I know exactly what to do.

    • @boris9305
      @boris9305 8 років тому +1

      +Pappa Bob It's different codes in different states/provinces. In Ontario you can put 2 romex wires in a pancake and use the pancake box wherever you want.

  • @venividivici4253
    @venividivici4253 5 років тому +3

    When you hooked that wire onto the screw terminal, why didn’t the electrician clamped it down with the piers to close the loop around the screw then tighten the screw? That’s pure laziness what the electrician did.

    • @GlitchedPepsi
      @GlitchedPepsi 5 років тому +2

      Not really its clockwise so its fine

  • @follow_fraser3081
    @follow_fraser3081 8 років тому

    In Canada you can't splice in a pancake box.

    • @EXLMOB
      @EXLMOB 7 років тому

      it's pretty much code anywhere since they are are about 7 Cubic inches and 14/2 is 6 cubic inches.

    • @AMD1
      @AMD1 4 роки тому

      @Jupp Schlabutt What's to worry about with wire nuts? Bad/loose connections only occur when installed wrong.

    • @AMD1
      @AMD1 4 роки тому

      @Jupp Schlabutt North America has both push in and lever wago connectors available. Lever wago's are gaining popularity, but a lot of people are hesitant about using the push in wago's because of a similar design used on older outlets/switches. They were an inferior design, which in a short period of time became apparent that the connections were loosening as the springs became weak. It's my understanding that several European countries had wire nuts. They fell out of favor because they were poorly designed, and in a short period of time often cracked and became loose. Some designs in the past may have been inferior to their Continental counterparts, but that doesn't mean their methods of termination are unsafe today. With modern designs, no one type is better than the other when it comes to long term durability and operation.

  • @Guillotines_For_Globalists
    @Guillotines_For_Globalists 8 років тому +1

    He could have kept the same smaller box. You can fit four switches in a standard two switch box if you really wanted to.

    • @TrafficControlFreak
      @TrafficControlFreak 7 років тому +1

      sure, but it's definitely not code and would not pass inspection!

    • @benmardis8237
      @benmardis8237 7 років тому +3

      Makes it much easier for fishing wires with the box removed

    • @RedBullishTrading
      @RedBullishTrading 6 років тому +2

      Traffic Control Freak stack switch is code and UL listed.

  • @omarr.378
    @omarr.378 7 років тому

    What would an electrician charge for a job like that?

    • @EXLMOB
      @EXLMOB 7 років тому +2

      I would have charged close to 300-400 usd

    • @AlMai222
      @AlMai222 5 років тому

      Ryan Simmons LOL

  • @kevinherrera836
    @kevinherrera836 8 років тому

    I have a problem with a dimmer switch?

    • @crapper1
      @crapper1 8 років тому +6

      Kevin Herrera hammer fixes 99 percent of all problems

    • @zachreese6540
      @zachreese6540 7 років тому

      Burn the house down

  • @UsCrestElectric
    @UsCrestElectric 5 років тому

    you guys did an electrical code violation. you can not run 2 pcs of Romex wire in a pancake box. instead you can install a 4s box to run 2 romex wires

  • @romuloromero2268
    @romuloromero2268 2 роки тому

    Of course they have attic access 😤. Show us an example where they don’t, like in most houses

  • @Tymullen
    @Tymullen 7 років тому +5

    2:39 CODE VIOLATION!!! ⚠️ You can’t drill through a box- you buy a retrofitted box with tabs that go on the back of the Sheetrock

    • @ThaChazo
      @ThaChazo 6 років тому +3

      2:27

    • @venividivici4253
      @venividivici4253 5 років тому

      2:39 is incorrect too. Should have tightened the loop before screwing it down.

  • @davide82843
    @davide82843 5 років тому

    His earrings look hip

  • @camojim5402
    @camojim5402 4 роки тому

    Not only did he overload the pancake but you're only allowed 1 romex in each of the plastic tabs in the 3 gang box. Unless it's a single gang only 1 wire per tab. This animal also decided not to use a drop cloth or an old work box. He also cut the hole like he had zero pride in his work.

  • @jacobgarner5593
    @jacobgarner5593 4 роки тому +1

    Your only allowed to put one one romex wire to each metal pancake box 💯
    Not up to code !
    An inspector wouldn’t allow to romex wires in 1 metal pancake box.
    Am I right or wrong ?

    • @steveloux4709
      @steveloux4709 3 роки тому +2

      The fill for #14 AWG conductors is 2.00 cu inches for each wire entering the box to be spliced, plus one (1) count for all grounds entering, plus one (1) count for any internal cable clamps or hickeys (of which there are zero in this case). So (4) current carrying conductors x 2.00 cu in = 8 cu. in plus one ground count of 2.00 cu in = 10.00 cu in required. That appears to be a Raco 293 pancake box; the manufacturer indicates the volume of the box is only 6.00 cu. in. Splices of this nature cannot be made. If the electrician were committed to the pendant location mounted at the joist, he should have brought a single 14/2 cable up from each pancake to the attic and terminated in a 4-square junction box with adequate volume to make an appropriate splice.

    • @edsadler4196
      @edsadler4196 2 роки тому

      Steve I was thinking he was going to run to a 4 square when I was watching. I was very surprised when I seen two box connectors in the pancake. I’m not sure where they found this electrician but he needs to be trained on the code.

  • @Stardust_Truth_Seeker
    @Stardust_Truth_Seeker 5 років тому

    Oh that's such a shame you edited out the most important part to see how you do is to thread a second wire through beside the original one and to see how it could be pulled down through the wall was crucial! could you please please add a video to show how to do that?

    • @RobertLeBlancPhoto
      @RobertLeBlancPhoto 5 років тому

      There's an open vertical cavity in the wall, and the new wire was simply fed through it by first dropping a fish from above, tying the new wire to it, and then pulling it up, which they showed being done.

  • @slappadabass3290
    @slappadabass3290 3 роки тому

    Two drywall screws for a three-gang box huh?
    💩

  • @denniskintanar7971
    @denniskintanar7971 9 років тому

    it is for mommy mmy

  • @laydlow87
    @laydlow87 6 років тому

    Amateur hour

  • @Trackman80
    @Trackman80 4 роки тому

    Hack

  • @elchotocorazon
    @elchotocorazon 6 років тому

    seriously wtf do yall make your houses out of a big bad wolf would be able to huff n puff yo asses

  • @denniskintanar7971
    @denniskintanar7971 9 років тому

    what is your address