Common mistake or Common problem? Day In The Life Of A Plumber

Поділитися
Вставка
  • Опубліковано 23 чер 2024
  • Day in the life of a plumber and we are back to the large renovation we are doing and another common problem we find on the new Worcester 8000 boilers...they suck the life out of the gas meters giving low working pressure but is this a common mistake or a common problem when it comes to these boilers?
    Either way the low working pressure needs correcting so we need to update the gas pipe from 22mm to 28mm...which involved going under the floor boards and into the crawl space under neath the house which is never a nice job.
    See how we got on re running the gas which wasn't without its problems..even before we started laying pipe!
    Thank you all again for your continued support
    Subscription goal 9730/10,000
    #plumbing #howto #plumber
    Check the links below if you considering any work wear from Big Boots might save yourself a few quid
    BIG BOOTS 10% OFF LINK BELOW OR USE BULLDOG10 AT CHECKOUT
    www.bigboots.co.uk/discount/B...
  • Навчання та стиль

КОМЕНТАРІ • 79

  • @bluebulldog_uk
    @bluebulldog_uk  Місяць тому +1

    Anyone had similar experience when fitting worcesters? Let me know, as always thanks for your support 👊

    • @HughTL
      @HughTL Місяць тому

      ALLLLL THE TIME. Every 4000 / 8000 has to have 28mm. The compacts are fine with gas norrmally. Also fist thing id do is remove the lead and see if that helps with the gas

  • @bobbymckean915
    @bobbymckean915 Місяць тому +3

    Luke love the vid mate. Nice to know we all get the same jobs 😂😂😂 ( Make a site bog, standard bucket with some insulation around the top, a bit of cardboard for a lid, half fill with water) 👍👍😂😂😂

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Yes mate, can’t forget the insulation, makes the toilet lot better…bag as well 😅😅

  • @youbeenshamed
    @youbeenshamed 26 днів тому +1

    Great honest video, I’ve Faced this challenge many times also , used to gamble, found myself upgrading more than anticipated at times and its put a dent in the schedule. Moving forward from here unless I’m sure I’ll do a Calc and size it. Ten minutes work will give a good idea what’s required and save you over killing it with 28mm as sometimes happens with just estimating the run. Keep up the good work

  • @waynebrown7671
    @waynebrown7671 Місяць тому +4

    Easiest way on that gas run would of been Gastite flexible stainless plastic coated pipework and fittings they sell a 28mm upgrade pack online no joins under that floor 😉👍

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Never used it, what’s the costing like?

    • @martinwright7093
      @martinwright7093 Місяць тому +1

      @@bluebulldog_ukIt is quite expensive. 28mm x 15 metre kit is around £300 or so from BES. They’re not the cheapest but gives you some idea.

  • @paulstanyer8604
    @paulstanyer8604 Місяць тому +3

    Some installers don't check pipe sizing or read Mis when installing a new boiler they think the old boiler worked so it will be ok and wouldnt have a clue how to do a pipe size calculation anyway. Good honest video Luke

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Thanks 👍

    • @Brizzle9293
      @Brizzle9293 Місяць тому +2

      You have to do pipe sizing in your ACS so that’s not true

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      @@Brizzle9293 you do thats true but how much of the ACS do people remember or go back to…should be done but can be overlooked or ignored or sometimes not been able to gauge where the pipe runs can be a pain

    • @Brizzle9293
      @Brizzle9293 Місяць тому +3

      That’s true not slating what you’ve done, more the comment of most lads wouldn’t have a clue how to pipe size. Hear it all the time and it’s pretty tedious, so quick to slate other engineers

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      @@Brizzle9293 I know what you mean mate 👍👍

  • @matthewjohnson5477
    @matthewjohnson5477 11 днів тому +1

    Think manufactures instructions say if its a 40kw it can be 15.5 at the gas valve

  • @772pcs
    @772pcs Місяць тому +1

    Great video. Big spiders and all!

  • @jameswilson2899
    @jameswilson2899 Місяць тому +2

    Well done with that mate, especially on your own, I would have been cursing as well.

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Thanks mate….empty house but in back of my head I kept thinking what if someone starts putting the boards back down while I’m under here 😅😅

  • @chlalew
    @chlalew Місяць тому +1

    Should've stuck 35 down the hole! 😂 Even though I think you're still a little low according to BS (1mb drop between meter and appliance) most real world installers know that boiler is going to work just fine. Boiler is only going to run at max during hw demand and will probably throttle down as well. Ch is somewhere round 24kw. Problem may occur if other appliances are fitted, but that's not your problem.

  • @alimack5489
    @alimack5489 Місяць тому +3

    You need an apprentice that looks like a perfect job for one under there 😂 and he’s not allowed up until it’s done!

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +2

      That was me 18 years ago…throw the apprentice under for the day 😂

  • @mickobyobrien2650
    @mickobyobrien2650 Місяць тому +2

    I thought i saw a toilet under the floor 😮😂😂

  • @dbinga6204
    @dbinga6204 28 днів тому +1

    Got told by worcester on their 162 commercial boilers they will work safely down to something like 2mb gas pressure (obviously wouldn't get the full output though), not sure if that the same with there domestic range, also think their domestic range used to let you have 16.5mbar on the ilet due to the loss through the gas vale and gas connection firtings to the boiler

    • @dbinga6204
      @dbinga6204 28 днів тому +1

      Just got to 24nmin and You've pulled the page up in the book I was on about😂

    • @bluebulldog_uk
      @bluebulldog_uk  27 днів тому

      😂 yeah I’m sure they will test them right down to lower than what’s in book, commercial I’ve heard there’s more tolerance in the readings

  • @ben2692
    @ben2692 Місяць тому +2

    An equivalent Ideal you wouldn't have had a problem with the gas pressure mate.

    • @bluebulldog_uk
      @bluebulldog_uk  27 днів тому

      Yeah ideal am a lot more tolerance and don’t seem to suck the life out the meter 😂👍👍

  • @SuperWayneyb
    @SuperWayneyb 29 днів тому +1

    🤘😎🤘

    • @bluebulldog_uk
      @bluebulldog_uk  27 днів тому +1

      🙌👍 thanks for the support as always mate much appreciated

  • @graememclaughlin720
    @graememclaughlin720 26 днів тому

    .010m3 or IVx1.5

  • @jonny7491
    @jonny7491 Місяць тому +2

    Just remember to put your handbrake on.😀

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +2

      I’ve never forgotten after that day 😂😂👍

  • @markchambers
    @markchambers Місяць тому +3

    Hi Luke
    I'm not being a knob but have you considered the Gas supply being in voids as it's something I really find a difficult scenario.
    I'm guessing the ground floor void vented through air bricks but not so sure under the bathroom floor.
    I'm sure you're aware but the lead flex on the existing supply is basically 15mm bore and would have been half the issue if not more.
    I replace them immediately if I see them

    • @markchambers
      @markchambers Місяць тому +1

      Hi Luke
      How's the Installer Show been
      Are you there tomorrow
      ATB
      Mark

    • @markchambers
      @markchambers 29 днів тому +1

      Hi Luke
      I'm a knob after all.
      Nothing wrong with Gas pipe under joists flooring.
      I've spoken to Gas Safe Register on their stand at Installer Show.
      There's a Technical Bulletin on it according to GSR.
      Basically test been done and gas will escape
      Please accept my apologies.
      I've seen your van at show but not you.
      ATB
      Mark

    • @bluebulldog_uk
      @bluebulldog_uk  27 днів тому

      Hi Mark, sorry I missed you at installer mate, been a busy few days and not had chance to catch up. Always appreciate people asking questions mate no matter what it is as someone may be thinking the same thing and not know, so it’s always helpful, appreciate the comments and hopefully I can catch you on the next one 👍👍

    • @markchambers
      @markchambers 27 днів тому +1

      @@bluebulldog_uk Hi Luke
      I ambushed you by your van in the car park
      It was great to meet you 😁
      Enjoy your content
      Have you thought of purchasing a GoPro as would be easier for you to film stuff

    • @markchambers
      @markchambers 27 днів тому +1

      I spoke to two Gas Safe Register employees at their stand.
      There's a Technical Bulletin about it.
      Basically tests were done in relation to under flooring and tiles etc and gas still escaped
      Worth knowing
      He did though say you should risk assess it for yourself and if necessary fit ventilation
      I've done it by fitting ventilation in soil pipe vent boxing etc

  • @sidpf1972
    @sidpf1972 Місяць тому +4

    Can you put a test nipple on pipework just under boiler,then your first reading may of been ok?

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      That would be working pressure before boiler, Worcester would have still checked the boiler pressure and deemed it inadequate

    • @sidpf1972
      @sidpf1972 Місяць тому +2

      @@bluebulldog_uk yeah,thats what it says in the mi
      Before the gas vale - 2.5mb then minus on the gas valve itself
      Transco are happy with 16mb at inlet gas valve in service mode on max

  • @ununha
    @ununha Місяць тому +2

    U should fit a 25kw and save u and the customer lots of hassles

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Water pressure too good for a 24kw 👍

  • @user-kq9gq2xq2f
    @user-kq9gq2xq2f Місяць тому +3

    Its not a Worcester thing? If you fit a 30kw boiler or whatever size you have to size the pipe to the boiler output?

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Yeah you do but it just seems Worcesters am excessive for sucking the gas

  • @andrewoleary9704
    @andrewoleary9704 Місяць тому +2

    Have to employ a small child mate. At a bag of sweets a day it’s a no brainer

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Just get central Heatking in for day, works for bag of quavers and a can of coke 👍👍👌😂😂

    • @andrewoleary9704
      @andrewoleary9704 Місяць тому +1

      @@bluebulldog_uk 🤣😂🤣

  • @johnward5006
    @johnward5006 Місяць тому +3

    Why you don't follow industry standards when determining pipe sizing and gas rating is beyond me!
    Proper surveying equals a professional instal.

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому

      Pretty sure I explain this in the video if you watch it mate about sizing the pipework

    • @johnward5006
      @johnward5006 Місяць тому +1

      @@bluebulldog_uk My point was you should have had a greater expectancy of the possible shortcomings of the installation pipework simply by walking the job and noting just the obvious straight lengths.
      It's not just a Worcester issue, all zero governors suffer big losses across the valve.
      The Gas rate will always be the ultimate determining factor!

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому

      @@johnward5006 pretty sure I had expectations When I explained to customer that it might need upgrading in quote..again said this in video, old boiler gas rate was fine and working pressure.

  • @charliefox6987
    @charliefox6987 Місяць тому +1

    so the pipe which run vertically was clipped to the door frame is this ok?
    I'm looking to do a new gas run in-between floors on a property I'm working in. The builder is trying to make as little mess as possible. (keep the cost down)
    normally I would be run behind plaster board or chase it within the wall.. however this time they have requested to run in between floors clipped to the wall. (in the corner)
    reading through volume 2 of the viper book I can't seem to find anything which says its against the rules as long as its sleeved both ends. equally I can't seem to find anything to confirm its ok !

  • @Heatking
    @Heatking Місяць тому +3

    How rude 😂

  • @accesszero4803
    @accesszero4803 Місяць тому +1

    Sod this , this is ehy a press gun exsists

  • @dereklees4064
    @dereklees4064 Місяць тому +6

    It's basic pipe sizing mate, nothing to do with Worcesters and I can't understand this worcesters suck the life out the gas? 30kw boiler will suck same amount of gas irrelevant of manufacturer. The 1.5mb drop between boiler and gas valve is the allowance worcester give through internal gas pipework. I.e a total of 2.5 mb drop from meter.

    • @bluebulldog_uk
      @bluebulldog_uk  Місяць тому +1

      Just going off what I’ve seen and other engineers to be honest, I agree a 30kw boiler is 30kw but just seems the new Worcester drops in pressure more than other boilers

    • @johnward5006
      @johnward5006 Місяць тому

      Glad I'm not the only one that understands this and quite simply, if an appliance is designed to consume 30kw/hr or 300kw/hr that's exactly what you are ultimately looking to achieve.

    • @mikewebber5171
      @mikewebber5171 Місяць тому

      2.5 m bar drop allowed through gas valve. 1 mb at test point at boiler.

    • @johnward5006
      @johnward5006 Місяць тому

      @@mikewebber5171 1.5 across valve, not 2.5.

  • @alimack42
    @alimack42 26 днів тому +1

    I wouldnt be going below a floor with shorts on mate. Feck your knees

    • @bluebulldog_uk
      @bluebulldog_uk  24 дні тому +1

      I bought some slip on knee pads I normally keep in van that cover most my bottom leg but left them at home 😅