Cutting takeoffs and proper attachment to trunklines (Mechanical Training # 104)

Поділитися
Вставка
  • Опубліковано 26 лис 2024

КОМЕНТАРІ • 188

  • @derekw40
    @derekw40 2 дні тому +1

    This guy did a great presentation. Tons of real information very little filler.
    Thank you sir.

  • @markmartin6856
    @markmartin6856 8 місяців тому +19

    You can always tell when you're being taught by someone with tons of experience. Great job dude!

  • @Tony-dk1bp
    @Tony-dk1bp Рік тому +32

    I can't imagine a better teacher.

    • @yodamanrulz176
      @yodamanrulz176 Рік тому +2

      I have to applaud the teaching capacity, patience, and forthright giving the knowledge that this fellow is capable of. Your methodology should be taught to other teachers. So many are flawed. Thank you for your time sir. You’re one in 1 million. 👍🏻🤓

    • @courtneywilliams9530
      @courtneywilliams9530 Рік тому +2

      I teach for a living and he is a natural born teacher. His companies website says they have 100 years of experience, so I’m guessing he came from a family of excellent teachers. But I’m sending this to a number of my HVAC oversight on projects I’ve volunteered for because it is so helpful. Please keep putting out more. I will watch them all!!!

    • @Mr572u
      @Mr572u Рік тому

      ⁠@@courtneywilliams9530. Company’s

    • @RealGame101
      @RealGame101 2 місяці тому

      Yeah he's good

  • @lmoore5264
    @lmoore5264 19 днів тому +2

    What a great video Andrew. I can't believe how much I learned in 36 minutes. You didn't stand there and babble for 10 minutes, you got straight to the point. In my book you are the definition of the word PRO. I wish we had more you tube creators like you. You didn't waste my time and I learned a lot. Thank you!

  • @alexeilesukov6624
    @alexeilesukov6624 10 місяців тому +21

    My baby brother just recently got promoted to foreman at a hvac company and wants to bring me in. He told me to try to learn as much as possible about the trade by watching UA-cam videos. He said that your videos are the most informative ones and that I should follow and subscribe. He also told me to lose some body weight. When you mentioned working in crawling spaces and uncomfortable positions, I understood. Thank you

    • @erichorton1440
      @erichorton1440 7 місяців тому

      Highly recommend starting your own hvac company. You'll make millions.

    • @FcsstlHeatingCoolingPlumbing
      @FcsstlHeatingCoolingPlumbing 4 місяці тому

      I use zip tie and 3 zip screws into the band of the zip ties.

  • @douglassmorris7375
    @douglassmorris7375 11 місяців тому +7

    I'm a DIYer and started a register reposition out of frustration. Was really uncomfortable until I watched this video. I am now so ready to finish this job😀.

  • @199randomhero
    @199randomhero 3 місяці тому +6

    This is hands down the best video I've seen for someone new to hvac and explaining how to do these connections and cutting, thanks!

  • @patrickjoseph7726
    @patrickjoseph7726 10 місяців тому +5

    Andrew, that was fantastic ! I'm a professional handyman and this is probably the best video I've ever seen for conciseness, camera quality, knowledge, and voice presentation . Great job ! PJ

  • @WOW_AQUATICS
    @WOW_AQUATICS Рік тому +19

    Best video on professional instruction installation I have ever seen. Thanks sir.

    • @tantricsphinx
      @tantricsphinx 11 місяців тому

      When this piece ended, I thought, "Wow! That was the best..."
      🫡

  • @jamespurchase4035
    @jamespurchase4035 11 місяців тому +45

    Jack Reacher does HVAC too? I'm impressed😂

  • @matthewray4637
    @matthewray4637 Рік тому +5

    From a fluid mechanics point of view, adjacent takeoffs (or takeoffs on opposite sides of the trunk in the same area) are more efficient than having two side by side on the same side of the trunk (particularly when they are close together). Adjacent ones will evenly distribute the airflow to both takeoffs and create two opposing vortices in the trunk which creates a negative pressure in front of takeoffs leading to a forward turbulent flow in the trunk line which has better sheer properties and can actually improve performance over longer runs. Having them on the same side one after another will create two vortices with the same direction on the same side, this can cause two big issues. First, if they are too close, you will have flow separation and potentially flow reversal immediately after the second takeoff. Second, if they are too close the vortex around the first takeoff can create a turbulent flow over the outlet to the second one creating a drop in pressure in the second line.

  • @TAYLORD_Technologies
    @TAYLORD_Technologies 3 місяці тому +3

    I have to say... this is the first video I've seen of this guy and AGL Mechanical. This is hands down one of the best teachers I've seen on UA-cam. A lot of relevant information and little simple tricks of the trade. 10/10

  • @michaelohara2161
    @michaelohara2161 3 місяці тому +2

    I’m a Sheetmetal Local 80 commercial journeyman retiree.
    I carried that tool for years. I used it off and on.
    I never liked it much, because of the metal shavings everywhere. I always had my hammer, flat screwdriver and midwest aviation snips.
    Those flange taps are relatively new. Spin on and tab taps, and conicals, were way more common. Although I do like them.

  • @freddycarballo4248
    @freddycarballo4248 10 місяців тому +3

    Man you are professional with no doubts.

  • @pin_cushion
    @pin_cushion Рік тому +2

    Please keep making content! These videos put This Old House to shame. I just paid for a system design for my house with no preexisting duct and I'll be DIYing and this is the best advice for ducting i've stumbled across.

  • @tantricsphinx
    @tantricsphinx 11 місяців тому +1

    Andrew, I wasnt familiar with your channel before watching this video. Just wanted to say that I love your communication style. So deliberate, detailed, well reasoned...no fluff all useful knowledge. That was 36 minutes of learning. A very satisfying experience. Thank you!

  • @ianhinkle4587
    @ianhinkle4587 Рік тому +6

    2 years as an apprentice summed up in a 36 minute video. Great work. Keep them coming.

  • @JohnBehling-ek6ik
    @JohnBehling-ek6ik 5 місяців тому +2

    Outstanding video- you are an excellent teacher. Thank you for taking the time to share some of your knowledge.

  • @Esiddik
    @Esiddik Рік тому +2

    I watched like toooooo many videos of nonsense before I found you!!! and the only problem was because your title makes your videos hard to find !!!! 😭😭😭 ( for a beginner not knowing those are the terms to use)
    Amazing tutorial , you are an amazing teacher!! I wish I found you 16 videos ago 👏🏼👏🏼👏🏼👏🏼

  • @gordonbramhan7520
    @gordonbramhan7520 Рік тому +1

    I have been in hvac for 30 years but installing ductwork is not my thing. Thanks for the information and detailed explanation
    I use zip ties and duct aluminum tape exclusively

  • @bradsmart7190
    @bradsmart7190 10 місяців тому +1

    Took on the job of installing my own furnace/heat duct. Lots to learn, thx for all the in depth info!

  • @mikev.1034
    @mikev.1034 4 місяці тому +1

    I seen a bunch of videos like this but, I think your method is definitely superior to other methods I seen. 👍

  • @ebbiebob
    @ebbiebob 28 днів тому +1

    Man you make amazing videos! Thank you so much! I really appreciate the education! Bless you! 💪🙏💯💯

  • @JayMurrr
    @JayMurrr Рік тому +1

    I watched many videos and got bored AF. But for some reason yours got my attention and I watched the whole video. I’m trying to add a run to my garage so I’m sure this is what I need to learn.

  • @jeremygattenby2183
    @jeremygattenby2183 Рік тому +2

    Thank you! Going to be installing my own ducting to save some money. This video really helps.

  • @danurdahl4420
    @danurdahl4420 3 місяці тому +1

    I really enjoy these videos and he explains what he is doing so well.

  • @jdawes4403
    @jdawes4403 Рік тому +1

    Keep ‘‘em coming bro- you’re helping people !

  • @3dux128
    @3dux128 Рік тому +1

    Pro! Pride in workmanship! Whatam I doing here. He had me hooked. Thanks.

  • @thomasbessent3670
    @thomasbessent3670 Рік тому +2

    sir I want to thank you for an outstanding presentation ! you have saved me thousands of dollars , you are very practical in your profession you have one good gift , and this one is needed in the HVAC community as a homeowner I will take out my 30-year-old duck board that has invaded my home . again thank you so much for your presentation ): God bless you and your family .

  • @marcveuhoff1871
    @marcveuhoff1871 Рік тому +1

    Excellent Video! We'll explained. I've seen many duct tutorials and you are one of the best.

  • @israelquintanilla2784
    @israelquintanilla2784 7 місяців тому +1

    Thank you for taking the time to teach us this very much appreciated

  • @gabrielakerekes5844
    @gabrielakerekes5844 Рік тому +1

    Amazing video,very clear and at point teaching. Love your video and too bad you are not servicing Florida. We need to connect almost all returns from rooms to the main line. Builder did run the flex tubs but didn’t connect them to the Trunkline and that cause us a great trouble with AC uneven in rooms having 6-7 degrees difference from main hallway in the middle of the house where the main return it’s hook up and the rooms around the hallway. Now after leaving 10 years in the house we discover the returns are not hookup to the trunkline. I would love to give you the job but you are in different state. But honestly your video couldn’t be more clear and having mechanical knowledge and education,I think we my husband we can do it.
    Thank you for your video and I already subscribed . I enjoy watching you valuable classes! 🥂

  • @annemoreno362
    @annemoreno362 Місяць тому +1

    I've looked everywhere for an adapter that would take and go from the register into the trunk line on both sides and continue down and across the transfer duct kind of a wonky T. They are nowhere to be found. I applaud you making your own

  • @Davidandgoliathhvac
    @Davidandgoliathhvac Рік тому +1

    Great content Andrew! Keep showcasing your craftsmanship! It inspires guys like me to improve our skill set and quality of work.

  • @colindgrant
    @colindgrant Рік тому +1

    Fantastic video. Very well explained with no fluff.

  • @philiplacey5430
    @philiplacey5430 Рік тому +1

    God help me if I ever need to crawl up in an attic and do any of this - but if I do, I'm ready! Nicely done!

    • @shellylynn899
      @shellylynn899 3 місяці тому

      It's horrible in the dead of summer with this crazy humidity

  • @absoluteidaho3767
    @absoluteidaho3767 8 місяців тому +1

    Excellent video and information! Thanks for sharing your knowledge!

  • @edwardsmith9256
    @edwardsmith9256 Рік тому +1

    thank you for your excellent lesson on Flex duct work. I am currently replacing my old flex duct. I now see what I could have done better. Thank goodness, I have only just started. Hopefully, the fold back method will make things much easier. Thanks again for your video.

  • @RealGame101
    @RealGame101 2 місяці тому +1

    This video was so good thanks man. All I need to do now is figure out where to reduce the lines

  • @tomhernandez1308
    @tomhernandez1308 Рік тому +1

    I thought your cutting method for a takeoff hole was quite novel and effective. Given then chance, I'm gonna try that myself in my own DIY work. Thanks for the very helpful video.

  • @clemgray
    @clemgray Рік тому +1

    Thanks… You just saved me $4000. Awesome

  • @lawlissmml1
    @lawlissmml1 2 місяці тому +1

    Elon should hire Andrew to work at Space X. The prior comments nail it - he is an enigma. A rockstar instructor!

  • @monkeyfinger7949
    @monkeyfinger7949 7 місяців тому +2

    Really great tutorial. I learned a lot. Thank you!

  • @ryansport33
    @ryansport33 7 місяців тому +1

    I'm hooked. OG methods shown here!

  • @scottschweigert1657
    @scottschweigert1657 8 місяців тому +1

    you gotta add a tip jar or something to your links --- this is such well done and high quality content

  • @yorkrojas1452
    @yorkrojas1452 Рік тому +1

    Thank you Sir. Just started in the Trade!! Thanks a Million!!

  • @terrygrant8126
    @terrygrant8126 11 місяців тому +1

    I have done it wrong and now I know thanks to you friend!

  • @carlotodaro5052
    @carlotodaro5052 Рік тому +1

    awesome lesson, I can't wait to see the workmanship I have in my attic. I'm going to finish a room upstairs and wanted to see how everything needs to be. That was a great how to and explanation on how it all works. thank you, Sir.

  • @briancarroll.
    @briancarroll. 8 місяців тому +2

    Great video. Thanks for the lesson!

  • @markdarling7526
    @markdarling7526 Рік тому +3

    Just watched all 36 minutes and loved it. You have taught me a lot about running and installing ductwork. Am about to tackle my house here in Florida. Original ductwork is 39 years old and I’m losing air and house stays dusty all the time. My house is only 1200 sq ft
    and replaced my unit from 1 1/2 ton to 2 1/2 ton just 10 months ago. The original ductwork is all flex , main truck line is 10” with 4” going to all the registers. Any tips or advice or other of your videos of yours you can tell me. Thanks again for taking the time to share your knowledge in this matter of HVAC ductwork.

    • @Perly53
      @Perly53 Рік тому

      Hi Mark. I'm in FL too with similar situation. Did you get this done? How did it go?

  • @jerryc7016
    @jerryc7016 Рік тому +1

    Excellent video. Very detailed. Easy to understand. 👍

  • @WhiteWakedNProud
    @WhiteWakedNProud Рік тому

    TWIMC
    here in socal in commercial for flex tails, we use panduits with a strap gun and some people sink 3-4 screws into the zip tie. After using the strap tool, I've never had one snap or fall off with or without screws. As long as the strapping tool was used on a fitting with a rib, without a rib it'll forsure pull off but get it tight with the strap gun and fasten some screws through the zip ties, like 3 or 4 minimum even spaced out, then call it good. And the use of tape is unnecessary and air leakage will be minimal which imo makes the process easier, quicker, and prevents frustrations from working with tape.
    I'd also like to add that i think people snap the zip ties using the strapping tool and snap the zip ties which leads to frustration, causing them to hand tighten them or use linesman. Which is easily pulled off, however some screws into the zip ties can help without the strapping gun.
    However I believe this is due to mishandling of materials. If film tape, zip ties, or even the pookie get left in the sun it can degrade such materials significantly.
    Thank you showing how to insulate fittings, i spent hours google searching how to and such info was not available. Cant wait to wrap a 90 and it look tits

  • @pastormartinez4676
    @pastormartinez4676 Рік тому +1

    Branching is the best best method, it self-balances air pressure and velocity.gradually reduce the size from the plenum with wyes and always use angled take-off’s (unless you’re working on a tight area such as a basement)
    Also,make sure to use dedicated Panduit gun (semi or automatic) and keep duct stretched and turns smooth!
    As a side note,we always use manual adjustable dampers, (where access is possible) it pays off when customers call-back complaining about un-even airflow (trust me,they always find a problem in one of the rooms)!
    And last but not least… if you’re running over 25 feet duct,upsize diameter 2” for friction,remember air is a fluid and follows the rule of “Path of least resistance”!
    I keep learning and improving my methods every day and following others good practices I’ve seen when I get a chance(on service calls) and applying what I’ve learned over the years… I must say without bragging that the results are extremely satisfying!
    This video it’s a good introduction for the apprentice on “How to” do the work,but in practice wouldn’t perform at it’s best!
    Good enough it’s neither good nor enough!
    Don’t get me wrong,this is a good video,but it would be a great video if it further explained the above mentioned facts!

    • @TonyNanni
      @TonyNanni Рік тому

      Why don’t you explain what your “branching” method is and show these “angled” takeoffs you would use on round pipe trunk line.

  • @ArnettEducation
    @ArnettEducation Місяць тому +1

    man, thanks a lot for this! very helpful!

  • @tunaman2200
    @tunaman2200 Рік тому +1

    Excellent Video! Thank you!

  • @ansarhassan4
    @ansarhassan4 Рік тому +1

    Great video loved it, just wondering how to choose right duct size, I am planning DIY duct for my parents house. Please have video on this subject

  • @Lkom24
    @Lkom24 Рік тому +1

    I love the malco hole cutter

  • @The_Honcho
    @The_Honcho 3 місяці тому +1

    Great way to connect flex, this is how I do it now, even had my boss try to pull the flex off lol

  • @ericviele4379
    @ericviele4379 10 місяців тому +2

    Fantastic teaching and incredible work. My only concern was that you kept mentioning duct tape, but I’ve always heard duct tape is no good in this application (oddly enough).
    What type of tape do you use?

    • @rod00777
      @rod00777 7 місяців тому

      What type of tape is he using?

  • @jamescollins8148
    @jamescollins8148 Рік тому +1

    Phenomenal! Great video Thank You Andy!

  • @JonathanCamargo-q7c
    @JonathanCamargo-q7c Рік тому +1

    excellent explanation

  • @wdanderson1984
    @wdanderson1984 Рік тому +1

    Great information dude. Thanks for the video!

  • @josesquiabro5819
    @josesquiabro5819 2 місяці тому +1

    Great video

  • @janerikborge
    @janerikborge Рік тому +1

    Excellent presentation. Thank you.

  • @carloschacon3909
    @carloschacon3909 2 місяці тому +1

    Thanks for your video...

  • @MFD541
    @MFD541 7 місяців тому +1

    point is, no excuses for not knowing your job. well done.

  • @JackA2430
    @JackA2430 2 місяці тому +1

    Great video man

  • @kelturner5452
    @kelturner5452 Рік тому +1

    When we do takeoff on insulated trunks we use the end of starter to cut thru by rotating back& fourth,like when you demonstrated dropping marker. Fantastic tutitor glad I' ve found your channel,subbed 1st. video before done. Great content no nonsense instructions! Keep them coming,love phrase quality is your reputation!! Permission to borrow sir? Thank you

    • @aglmechanicaltips
      @aglmechanicaltips  Рік тому

      You can use that phrase all you want. I'm glad you like the channel.

  • @jimmyfavereau
    @jimmyfavereau Рік тому +1

    Gold! Thank you 🙏🏼

  • @aKumah.
    @aKumah. 9 місяців тому +1

    deserves a subscription 🤝🏼💪🏼

  • @andranika6203
    @andranika6203 Рік тому +1

    Thank you for teaching 👍👍👍

  • @davejohnsonnola1536
    @davejohnsonnola1536 10 місяців тому +1

    F&B refrigeration guy looking to upgrade my 1940s cottage to central HVAC.
    Gracias.

  • @jonc5152
    @jonc5152 Рік тому

    man - wish I'd found this sooner... I am on the tail end of redoing my upstairs (attic) ductwork. Not knowing how to handle rigid duct I opted to just do everything with flex. I basically made 2 straight headers down each side of the attic and tapped off to boots using wyes. I screwed the flex wire to the wyes with zip screws and sealed with mastic tape.... the inside air seals are durable but the jacket seals are not super great. I used canned foam to foam insulate the wyes but it makes the connection to the flex insulation odd. I think my way out to a decent quality is duct tape between the vapor barriers and foam. I am also considering zapping them with a coating of spray foam (2 part, not 1 part cans) as additional exterior sealant. If the duct taping goes well then I may just be able to mastic the whole joint instead.
    I leaned a lot on the attempt and I've also learned a lot from your great channel. If I redo my ducts in the future (if the ones I just did have an issue or maybe when I go to change out my new HVAC units in 12-15 years) then I will definitely go with rigid metal headers, hopefully I can just find pre-insulated spiral sections... I don't understand why those aren't more of a "thing".... pre insulated spiral with an array of pre insulated fittings... suspend, screw, foam seal together.
    Anyway... thanks Andrew!

  • @damianbenavides8653
    @damianbenavides8653 Рік тому +2

    Thanks 👍🏻👍🏻

  • @johndavidson5564
    @johndavidson5564 Рік тому +2

    Ok liked and subscribed first of all, second, I'm a commercial HVAC lead in Indiana and I have never seen anyone duct sealing the outside of insulation. Is that required in your area? we also never use the yellow formaldehyde insulation usually r-4 1/2 inch formaldehyde free, the white kind. Unfortunately, Panduit straps are commonplace here but I also tape the inner flex and then the outer after Panduits. Though after hearing your tear out experience with sweating I may stop panduit strapping the outer jacket. I am very curious to get your thoughts on some things as I am always trying to grow and learn. We typically wrap out pipes before installation, and then double back and duct seal all metal seems, then the next day we come through and piece out the missing insulation. We do not use staples as a matter of fact I have never seen staples be used here. Almost everyone uses Nashua FSK tape for holding the insulation together and some companies only use 3M Venture Tape UL181 which both does not adhere very well, and looks bad so I try not to ever use it. Also wanted to give you some video ideas since it seems that the channel is new. I would love to see you wrap a reducer and an end cap and some other fittings. thanks.

  • @nlh8162
    @nlh8162 Рік тому

    Well that's a great teaching sermon right there my friend the problem is you have to find the suppliers that will stock these parts I love those start collars not all suppliers have them

  • @salzafar2030
    @salzafar2030 Рік тому +1

    Great video, is this some special duct tape for hvac ducts? Thanks

    • @aglmechanicaltips
      @aglmechanicaltips  Рік тому +1

      Yes, the tools and materials used are linked in the video description

  • @ludwig6332
    @ludwig6332 8 місяців тому

    The guides state it is better to have opposite take offs at the same place for efficiency, as staggered close together reduces aire flow, static pressure.

  • @thecurious6721
    @thecurious6721 Рік тому +3

    Thanks for the great tips 👍 I am in Canada and we use rigid uninsulated ducts, which are (mostly) in conditioned space. But it is very informative especially as the flex ducts (as the manufacturers say) are gaining popularity here as well. Could you advise what kind of duct tape you are using and what will happen if you dont mastic over the tape at the take off? Do you use flexducts for 2 storey houses as well? We have difficulty moving air from the basement to the second floor with rigid ducts. I am wondering how it would be with the flexducts. Thanks 🙏

    • @aglmechanicaltips
      @aglmechanicaltips  Рік тому +2

      I was using Nashua 365 duct tape but I will changeout the tape used based on the season and outdoor temperature (super sticky duct tape is hard to work with on hot days). Mastic provides air sealing when applied directly to sheet metal seams. When applying mastic over duct tape on insulation seams it just provides another level of durability to the tape and prevents the tape from coming up. If you didn't mastic it, it would probably be alright but if it's available I would apply it.
      Couple notes on flex ducts; In my region, we don't have basements and normally wouldn't "chase" duct up to another level due to the length of run and a couple other factors. Long lengths like that should probably be ran in hard pipe but flex can be used if you do a static loss calculation on the flex and upside the flex to a larger size to account for the static loss. Example: a 6" hard duct that is 20' long might be equivalent to a 8" flex duct that is 20' long (I didn't calculate this, I'm just giving you an example). Hope this helps.

    • @thecurious6721
      @thecurious6721 Рік тому +1

      @@aglmechanicaltips Thank you very much for such detailed answer. 🙏

    • @hairlesscactus
      @hairlesscactus Рік тому

      Do you ever have condensation forming on the uninsulated ducts?

    • @thecurious6721
      @thecurious6721 Рік тому +1

      @@hairlesscactus in normal situation - no. In my experience I had issue only once, when the guy closed basement registers and it was very humid there and airflow was slow, so that ducts where very cold. Sometimes plenums sweat a little bit. Other than that no issues. And we have 70% humidity in the summer.

    • @hairlesscactus
      @hairlesscactus Рік тому

      @@thecurious6721 thank you for the reply!!

  • @scotthayes6946
    @scotthayes6946 Рік тому +1

    Hi Andrew. Great video. Great tips. Great techniques. One question: What is the duct tape you are using? Many thanks.

    • @aglmechanicaltips
      @aglmechanicaltips  Рік тому +1

      In this video I used Nashua 365 a.co/d/fAO8lsM This is a really sticky tape though so if it is really hot out 90°+, you might want to use shurtape (I dont have the model at this time).

    • @scotthayes6946
      @scotthayes6946 Рік тому

      @@aglmechanicaltips Wow.!! Thank you for the speedy reply. I will give the Nashua 365 a try. Many thanks.!!

  • @ProfessorGilligan1
    @ProfessorGilligan1 2 місяці тому

    I have flex duct that has disconnected from the main trunk in my crawl space. So, this is not clean, new vapor barrier.
    How do I get the old flex duct to attach back to the old and dirty take off and main trunk vapor barrier without just releasing? BTW, no mastic was used by the professional HVAC company. I’m wondering if I mastic over the properly attached vapor barrier release can be avoided.

  • @Joe-Gil
    @Joe-Gil 22 дні тому +1

    Ugyes!
    (Clever in hungarian)

  • @chris_jorge
    @chris_jorge 6 місяців тому +1

    damn there's no chance ill find someone in miami, fl that will do a job with this level of detail

  • @Ageehvac
    @Ageehvac Рік тому +1

    Thanks bro...lots of info

  • @learning2a2day98
    @learning2a2day98 9 місяців тому +1

    Electrician here, I can say I have never worked around any ductwork this guy has installed. The amount of times I have had to fix flex attachment points with only the large zip ties holding and zero tape. Weather, they are off when I get there or fall off from the easiest little touch. Having a conscious might make a little more work or take a little more time at the time, but what used to be called taking pride in one's work makes less work for all involved. Think down the line, after we all leave the jobs, service and maintenance involve human bodies with access being the most important part of those two inevitable facts of what we do in the trades.

    • @damienarnold6585
      @damienarnold6585 6 місяців тому

      Those guys must NOT be using a pan duet gun to tighten the zips. The zip will stay on a lot longer than the tape.
      I do hvac and when I run duct I use both zip and tape. Imo opinion to use one without the other is lazy. I've been back on jobs and seen the mess after a few years have passed .

  • @performancehvacr6629
    @performancehvacr6629 Рік тому

    I have always done at least two wraps of duct tape and 3 screws. Do you find a need for screws? Awesome videos. I watched the first one a while back. Glad to see you back at it.

  • @gen-shynobi7939
    @gen-shynobi7939 3 місяці тому

    I just subscribed thanks for you r videos btw do you have a start to finish set of videos I /we can watch i want to install my own lines to my home im remodeling and this home 1950s didnt come with hvacand id like to install one im in need of this info asap thanks

  • @cadamham
    @cadamham 5 місяців тому

    How do you see taps with dampers and adjustable handle?

  • @devinfisher1815
    @devinfisher1815 4 місяці тому +1

    Is that tape 1402 mastic or something a little thinner? And I assume it’s not necessary to mastic over the take-off to supply line? Thanks for the info.

    • @aglmechanicaltips
      @aglmechanicaltips  4 місяці тому

      It is 1402 mastic tape. If using "mastic tape" then it is not necessary to mastic over the takeoff but it should be sealed one way or the other if in non-conditioned space.

    • @devinfisher1815
      @devinfisher1815 4 місяці тому

      @@aglmechanicaltips Ty!

  • @stevebabiak6997
    @stevebabiak6997 Рік тому

    No mention of dampers. Do you normally not use them?

  • @sergiohernandez4163
    @sergiohernandez4163 Рік тому

    By code in Kentucky we have to use metal tape and zip tides instead of mastic. I argue my point that zip tides are worthless but can't argue with the inspector

  • @elonmust7470
    @elonmust7470 Рік тому +1

    Thanks for putting your heart into what you do. I appreciate your sharing of knowledge!

  • @TheFla904
    @TheFla904 11 місяців тому

    If it’s snaplock pipe, use your duct knife and it pops a hole super easy

  • @lestalkmorebasss
    @lestalkmorebasss 4 місяці тому

    On a commercial job site the insulators get upset if you go around cutting circles out of their insulation. They’d prefer you mark the circle and cut an X so the insulation is not removed. The cuts let the insulation be folded back and the tap installed 🤙 in a residential setting the X cut method creates less trash in the attic. I’ve seen some really awful ductwork during my years and mostly it’s from carelessness

  • @xmanprime3328
    @xmanprime3328 11 місяців тому +1

    Safety glasses???

  • @darrenaugustine6508
    @darrenaugustine6508 Рік тому +1

    Thats awesome! What is your method of insulating boots?

    • @aglmechanicaltips
      @aglmechanicaltips  Рік тому +2

      We have been working on a video on insulating misc fittings which includes straight boots, 90 degree boots and endshot boots. We are hoping to get this video uploaded this week. Stay tuned!

  • @jasonredman2265
    @jasonredman2265 2 місяці тому

    That’s funny as hell! He looks just like that dude

  • @MichaelDFortner
    @MichaelDFortner Рік тому

    The heat in the attic will eventually harden the duct tape. I have some in my attic and it needs to be replaced. So I would use metal tape or something else.

  • @joeshearer1247
    @joeshearer1247 Рік тому

    I like cutting the take offs before I wrap it If I can…. just curious what you thought about that. Also why You don’t use the skrim tape for the duct wrap

  • @scottschweigert1657
    @scottschweigert1657 10 місяців тому +1

    do you have to use a round take off on a round pipe? or can you bend the flange of a flat take off to fit? (none of the supply stores in my area have round takeoffs)

    • @aglmechanicaltips
      @aglmechanicaltips  10 місяців тому

      I've always been able to find round takeoffs, that's odd that your suppliers only have flat. I don't think flat would look good because it would bend the pipe it is attached to.

    • @scottschweigert1657
      @scottschweigert1657 10 місяців тому

      @@aglmechanicaltips one of the downsides of living in Hawaii - had to change my plan twice. Was going to do duct board, but can only find 1” duct board r4… so I found a place with round metal duct, but now no local place (even Home Depot) has round take offs! I can get em shipped but then they’re like $70 each … and I got 10 branches