Quick and Easy Duct Design Information

Поділитися
Вставка
  • Опубліковано 19 лис 2024

КОМЕНТАРІ • 220

  • @allintrance
    @allintrance 4 роки тому +12

    Finally... a contractor that is not arrogant & will share some great info on common HVAC problems. THANKS!!

  • @allintrance
    @allintrance 4 роки тому +3

    After watching this I opened the louvers in my return air vents & the system is probably moving 20% more air. I also removed every other fin from my living room registers to allow more air flow. And the sucking & whistling is gone from my return now. This is my third system in this house in 42 years. This is the first time I’ve had sufficient air flow from my AC. THANKS AGAIN!!

  • @cyndicaserta7096
    @cyndicaserta7096 2 роки тому +16

    *Easy to assemble **Fastly.Cool*

  • @domenickm1966
    @domenickm1966 3 роки тому +5

    Nice to have someone like you explaining this stuff.

  • @DJV94022
    @DJV94022 2 роки тому +2

    Just a quick tip for those that have no clue this example is for normal size homes (not mansions or anything that big of house)
    Flexes and they purposes
    4” is for bathrooms /private toilet rooms
    Food pantrys/walk in closets, front doors or mudrooms,
    5” normally laundrys or a bedroom where you barely fit a twin or bunkbeds
    6” kids bedrooms , living rooms/family room,dining rooms
    7” kitchens, dining room,living rooms(will take 2)master bedrooms (will take two)
    8” master bed rooms , living room
    10-20” are usually trunklines, returns flexes

  • @gamking7987
    @gamking7987 5 місяців тому

    I've always come here to this channel for the right info and right to the point.

  • @XxDarkRaverxX
    @XxDarkRaverxX 3 роки тому +1

    I don't understand everything you said, but I understand a lot more than I did before. Thank you for taking the time to explain it to us. :)

  • @miguellorenzo249
    @miguellorenzo249 4 роки тому +1

    David my wife and I appreciate your information its very helpful and huge money saver thxs for putting it all together

  • @kencrane6420
    @kencrane6420 6 років тому +10

    David, you did a great job explaining some complex details and giving valuable information in this video.

  • @nickrobinson9503
    @nickrobinson9503 6 років тому +11

    Loved the information on wider grill spacing, that hasn’t even occurred to me. Thanks for the eye opener

  • @alexanderleal8770
    @alexanderleal8770 4 роки тому +1

    You are a fantastic instructor. Thank you for all the great information.

  • @mickbrown815
    @mickbrown815 4 роки тому +1

    David I’m glad you mentioned about the return vents and sizes!! I just couldn’t understand why we have 2 (3) ton units in a 2 story house but our bedroom that is on the first floor is notorious hot all the time. Now that you mentioned the vents ours seem tiny!! I will go buy some new bigger ones!! I had been up to the attic and believed that maybe some of the ducts weren’t on or where loose but everything was fine. Thank you for that information!

    • @mickbrown815
      @mickbrown815 4 роки тому

      David - well I ended up purchasing a couple of frost king air diverters so far it seems a whole lot better than it was. I got the biggest ones from Home Depot. Our sizes is 8 x 14 but vents are directed in every direction. So directing them over the sleeping area is better. I’ll see how it goes

  • @snort455
    @snort455 4 роки тому +3

    This is a lot of important info on supply theory! I haven’t seen anything like this elsewhere.

  • @Ronsonic
    @Ronsonic 4 роки тому +2

    Very helpful for me considering replacing my ductwork along with the new heat pump we're planning. This man is passionate about his ducting!

    • @jonwillard3198
      @jonwillard3198 3 роки тому

      Dude, get a metal shop to make your ductwork. I was a duct guy for a very reputable company which had a small tiny metal shop. We ripped out flex systems, ductboard systems that a mouse chewed into and died, and re did shabby ass installs. If yu go round pipe and flex runs, use six inch runs to each vent. Use reducers as yu go down the trunk. Make the return slightly bigger than the largest supply duct. And if yu use round pipe, get metal fittings made and use curved fittings to get to transition to the round pipe. It makes a difference. I fixed a job, I literally saw how much of a difference curves make vs. Flat square boxes and flat squares where the air changes direction. It makes a huge difference which translates into your energy bill which could turn into thousands and thousands of dollars

  • @nathanwilliams4056
    @nathanwilliams4056 3 роки тому +1

    Very good, easy to understand Dave. I appreciate your instruction manner - not over my head with big terminologies!

  • @chrishill1073
    @chrishill1073 4 роки тому +2

    You are very good at explaining , Unrestricted
    Airflow.
    RETURN
    THAT AIR !

  • @WelshPoniesandCobs
    @WelshPoniesandCobs 5 років тому

    This UA-cam video which you made is VERY HELPFUL! I am going to replace my grills, and my cousin who has found that her return ducting has holes in it is reading your video as I am typing as she just got a new 3 ton AC/HEAT HVAC unit and found that the AC doesn't blow hard enough to cool her mobile home. She guessed when she looked down her vent that the reason is that the reason is the holes in the ducting. Thank you for this video.

  • @k.scottphillips8933
    @k.scottphillips8933 6 років тому +1

    I haven't found anyone yet in my area who will do duct work modifications to our home. They are all happy to drop in a new HVAC but what we really need is to modify very badly remodeled ducts. One HVAC contractor even told me that he doesn't make enough profit doing ducts. At least he was honest. So if you are wondering why homeowners are watching your video, this could be why.

  • @angelgonzalez5237
    @angelgonzalez5237 4 роки тому +2

    Thank you David your a good person and you definitely know your trade. I appreciate all your videos and all the knowledge your giving us. Hope all is well stay safe be well David

  • @Trentfully
    @Trentfully 5 років тому +2

    Thanks for the video. Especially that part about grills is super helpful for my situation

  • @crobinson1479
    @crobinson1479 4 роки тому

    Excellent video!! We were going to replace ductwork ourselves. Now, we will get an HVAC person. Thx so much

  • @cam4usa
    @cam4usa 4 роки тому +1

    I have a new appreciation for HVAC guys!

  • @rayquiles9897
    @rayquiles9897 7 років тому +1

    David your videos are the best I've seen in terms of information and advise they are great. Thank Q!

  • @scottfowler3427
    @scottfowler3427 3 роки тому

    Very informative. You are a good teacher! Thank you 🙏

  • @davidliniewkski1687
    @davidliniewkski1687 3 роки тому +1

    SIR I need some help I live in a double wide trailer --I am going to buy a new air condition unit .the unit is just air no heat in the unit .i have a new heat unit in the hallway it has a 10 inch flex unit pipe from one side of trailer to the another side of trailer works great. now if i put a ten inch line from one side of the trailer to other side will this be OK. MY OLD AIR UNIT WAS THIS WAY. YOU NO TRAILERS HAVE METAL DUCTWORK UNDER THE TRAILER --HELP WILL BE THANKFUL

  • @jmc6940
    @jmc6940 2 місяці тому

    The regular guy has no other options but to do it themselves. The cost of living is out of control. You have to do it your self to survive. Thanks for sharing.

  • @jimmywilliams5842
    @jimmywilliams5842 4 роки тому +2

    Great practical real world situations you see as a "Seasoned Professional Technician". Great videos for the guys David. Thanks!

  • @smarterairelectrical
    @smarterairelectrical 4 роки тому +1

    Great video!

  • @jeffreygunter417
    @jeffreygunter417 4 роки тому

    Well done. Easy to understand and nailed the return issue.- Thanks!

  • @joeydelmarsjr.646
    @joeydelmarsjr.646 3 роки тому

    i got a 4ton for 1300sqft thats 350ft per ton in southern Nevada easy 115 degree days, i aim to get 1600cfm and my filter is 20x20x1 side by side for a total of 20x40 filter return. i currently use the honeywell HD merv 11 filters but i think ill start using the 3m 1200 merv 11 because of the more surface area on the filter to help decrease static pressure if that doesnt help ill try to use 4in filter

  • @edwardlopez8883
    @edwardlopez8883 5 місяців тому

    Ok I don't have air returns in my 2nd floor rooms and I want to replace my supply ducts aswell so do I make the return and supply both 7 inch flex which is what is on the supply in 1 room now?

  • @sterlinghousewashpressurew9594
    @sterlinghousewashpressurew9594 6 місяців тому

    Great information thank you.

  • @danielscroggins6806
    @danielscroggins6806 3 роки тому

    Thank you very informative, can you tell me if it matters where the heat outlet is placed in the room for best results mine seem to be to close to the room doors

  • @keithsac2542
    @keithsac2542 7 років тому +4

    Manual d is the proper way to calculate size of ductwork. Caution, when using a friction rate it is based on 100' of equivalent length of ductwork. Duct systems should use available static (T.E.S.P. of blower minus everything external of of equipment: coils, filters, grills, etc. x 100/ effective length of ductwork ) to size ductwork.

    • @JohnnyJr396
      @JohnnyJr396 5 років тому

      KEITHS AC thanks! So if you figure all pressure drops of everything outside of AHU it should equal the TESP of unit?
      Also why some use .1 for return and supply and others do .5 for return and
      .1 for supply.
      Too many contradictions

  • @FooDaki
    @FooDaki 2 роки тому

    hi david thanks for you videos .... how do u know wich friction loss to use per duct?

  • @EbanQHanna
    @EbanQHanna Рік тому

    Hello David, what size main (incoming) flex should I use for a triangular terminal box that has 2 x 8" flex please

  • @cast1070
    @cast1070 4 місяці тому

    Hi trying to fix a hot room , I changed the grill to same you showed , do I need to go from 5 to 6 flex in that room to cool it down more ? Is coming from a triangle at the end of the ductwork line box 2 5 inch line on each side to 4 vents 2 bedroom , small bathroom and one in dining room area , this one room is the one hot , no leaks

  • @ricksmith4087
    @ricksmith4087 5 років тому

    Thanks Davis, you are very helpful and explain things in a very understandable way. Much appreciated!

  • @fldave612
    @fldave612 Рік тому

    I have a 3.5 ton, 13.4 SEER packaged heat pump with an X13 blower and 10KW back up strips. My duct work is single 14 inch flex return, the filter box is a 14x20, the supply is also 14 inch flex that is wye'd off into 2 plenum boxes under the house, each plenum box feeds 5 vents, each supply vent is fed with 8 inch flex, the individual supply vents are 4x8's. All of the flex is black polyester. Does this sound adequate or undersized? I ask because I get a slight whistling from the return and the condensate will not drain if the blower is running even with a P-trap full of water and the bottom of the air handler side of the unit is always wet.

  • @newill7732
    @newill7732 2 роки тому

    Good info, thanks.

  • @ryanthomas8004
    @ryanthomas8004 2 роки тому

    LOL, "Ductulator" @3:00 . Great video, tks sir

  • @jaimepadilla6530
    @jaimepadilla6530 4 роки тому +1

    You're definitely 👍 💯 right ✅, exelent job 👏 keep up the good work. I like how you explained basic things to upgrade the performance of the Hvac equipment and get the most efficiency and extend the durability, save money on service calls, simple things go a long way awesome work;)

  • @paulhayes9200
    @paulhayes9200 4 роки тому +1

    So it sounds like if you use flex verse metal duct you reduce the volume by 50%. for calculating size of duct. So using metal I could use 6" duct, If I use flex I need 12" duct?

  • @dagestanifive
    @dagestanifive 4 роки тому +1

    David I have a question. If I design a duct system for example 4 ton airhandler @ 1600 CFM. I size the trunk line with the ductulator for 1600CFM, should all the flex drops CFM equal 1600 for a balanced duct system?

  • @j.r.1223
    @j.r.1223 4 роки тому +1

    Great info! Thank you!

  • @reekinhavok420
    @reekinhavok420 Рік тому

    if only everyone was this good at there job we be good

  • @juanpardo1073
    @juanpardo1073 5 років тому +1

    Great video, thank you Mr Jones

  • @randydimmette3457
    @randydimmette3457 3 роки тому +1

    David, thanks for all the helpful videos. I have a 1600 sq.ft. older home and not an open floor plan. 3 ton heat pump with gas furnace. The main trunk line has 7 ea 6" flex lines and 1ea 12" flex line feeding a 2 trunk line about 20' away that has 5ea 6" flex . There is very little cfm at the end of 12" flex. Would a 12" inline duct fan work to boost cfm's for the 2nd box. The 2nd box jas plenty of cool air. Thanks for any help.

  • @bobbrua8758
    @bobbrua8758 4 роки тому +1

    what about the tonnage on air conditioner nice video will subscribe

  • @woodrowharris3502
    @woodrowharris3502 Рік тому

    What does inside the duck work suppose look like from return vent to unit and from unit to one room as far material looking like inside of it and what point of 1500 soft house 500 is garage to have one big return vent and the other one e3 times smaller

  • @trinkladd
    @trinkladd 4 роки тому

    Thank u sir for the video. I am very hand and repair homes for a living. I am needing a ductwork designed for my home. But don’t want to pay an arm and leg. I will hire a professional to hook up the new unit. I want it efficient and have questions about how many returns the house needs. It used to be one. Now concensus seems to be some kinda return in each room or a vent pass through. I’m confused. Could you help me? Thanks -Jerry

  • @dutchslayer7056
    @dutchslayer7056 4 роки тому +1

    Great video! Where can I get the wide spaced louvered registers and returns? The brick n mortars don’t appear to carry them. Thanks!

  • @JuanGarcia-gj5fz
    @JuanGarcia-gj5fz 6 років тому +1

    Great info. Thank you😊

  • @hugovalenzuela6669
    @hugovalenzuela6669 3 роки тому +1

    Excelente!

  • @brucerice4577
    @brucerice4577 6 років тому +5

    Return grills, versus pass through grills, when and where to use them when and not to use them???

  • @thenexthobby
    @thenexthobby 13 днів тому

    My attic system servicing our 2nd floor has a noisy return. The flex duct looks huge and it's a short path to the air handler (although with one 90-degree bend. I do recall once temporarily running it without the grill and it was quieter. Not sure if it would pass the ballpoint pen test ... but shouldn't grilles have a CFM rating?

  • @mgarc1960
    @mgarc1960 3 роки тому

    What is your take on concealed ducted mini-split systems. Is sizing the same as a FAU? How about installing the unit in a vented crawl space.

  • @broncheemims8493
    @broncheemims8493 5 років тому

    Good job Mr. Jones

  • @speed3000gt
    @speed3000gt 4 роки тому +1

    How large of a return grill should you use for bedrooms? The return ducting is 9 inches

  • @andrewilliams8314
    @andrewilliams8314 6 років тому

    David when using 8 in flex duct connected to a 8 in adjustable elbow do you pull the flex duct insulation over the elbow to insulate elbow or use separate insulation to wrap flexible elbow thanks please show video

  • @lovoniamallory1269
    @lovoniamallory1269 4 роки тому

    hey day what do you think of heil. and I have an old house shopping around for contractors what to put it in the basement many folks just don't want to do it they want to go in the attic

  • @williamwatts8831
    @williamwatts8831 4 роки тому +1

    David we have a house without ductwork and a finished basement we are wanting to put in a furnace and central air would it be advisable to try to service the first floor with ductwork in the ceiling otherwise we've been told we'll have to gut the basement

  • @marconator3896
    @marconator3896 5 років тому +1

    If I have a room 13x11
    And I have a 6" supply grill
    Will be good to put a 6" return grill
    Above the door or will be better an 8"
    I remember when I start working on hvac we used 6" returns
    But now days I haven't seen that
    Anymore I see 8" returns even when the rooms has a 6" supply
    Wondering why?

  • @idanny76
    @idanny76 2 роки тому

    I have high static pressure on a new 3.5 ton heat pump. I know for sure the flex duct is the issue. I have two 12" coming out of the supply in opposite directions. I know I need an 18" for a 3.5 ton heat pump. I did a diagram layout of the duct in the attic. What would happen if I just replace the two 12" to 18"?
    Ignoring the downstairs, because everything is between the walls. The problem was even worse with an undersized return. The original and only return was a 24x18. The total static pressure on the unit was .9 W.C. I was able to drop the TESP to .66 by making the return 30x24. Since there is so much static pressure and the unit TESP is a .2 and I need an 18" for a 3.5 ton for 1400 CFM. How big does the supply plenum should be and what shape? Should the supply plenum split to 3 18" going out to each of the 3 distribution boxes? Do the other three distribution boxes also need to be larger?
    Looking at the triangle shaped supply plenum I have very little room up for a rectangle plenum. I think a 3 feet ductboard supply plenum should work. There is a foot from the Air handler to the ceiling and I think 2 feet from the attic floor to the roof. Now I am looking at two types of designs. Design #1 keeps the 18" ducts straight by having a single 18" coming out of the supply and then a distribution box splitting it to three 18". The sides would be coming out straight to the to side boxes and one going to the third box with a slight curve. Design #2 splits to three right at the supply plenum and goes to each box individually, but all three will have a slight curve. I will not be using any metal plenums..... it will be all flex duct and ductboard boxes, because of budget. I am not trying to make a perfect system, but trying to remove the restriction from the 12" undersized ducts installed and replacing the flex duct that was patched with mastic with new ones.
    Another question about the installation..... I have the flex duct running up and strapped to the roof for support. Since the supply plenum is low to the floor due to the roof..... Can the flex duct be run on the attic floor? Can you tell me which layout makes more sense and less restrictive? Thank you.
    Layouts:
    Current
    i.ibb.co/Ld9kmPM/Flex-Duct-Layout-and-Size.jpg
    Option #1
    i.ibb.co/GHyS00g/2022-07-05-0002.jpg
    Option #2
    i.ibb.co/PNN8mSB/2022-07-05-0001.jpg
    Air Handler Specs
    ibb.co/17VvF4B
    Video of attic
    ua-cam.com/video/iInIN89q8GU/v-deo.html

    • @DJV94022
      @DJV94022 2 роки тому

      For a 3.5 system to be honest it should be a 16” flex but it should be a 16x16 plenum fiberglass/metal from there you should use a 14” flex to the first box and a 12” to the farthest box thats away from the plenum

  • @Rch5.0
    @Rch5.0 2 роки тому

    Thank you

  • @bernieahaus1332
    @bernieahaus1332 4 роки тому

    Were do you get the grills that you refer to in your video

  • @steelod1528
    @steelod1528 4 роки тому

    Well hey david if we using .5 for the flex supply. What should the static pressure be for the return if its flex as well on the metal ductulator i dnt have flex ductulator

  • @kaitreehouse2258
    @kaitreehouse2258 6 років тому +2

    Great video, interesting information...Thank you. I have a question David, I want to replace my ductwork, located under the house, outdoor, on the ground, what type of flex is recommended? I live in Florida.

  • @trathehandymanchicago1976
    @trathehandymanchicago1976 4 роки тому +1

    thanks man

  • @thomasc9015
    @thomasc9015 7 років тому

    What size would the main trunk be coming off the unit. I have 1000 sf basement and 1200 upstairs my unit is in the basement ? Thnks

  • @miguellorenzo249
    @miguellorenzo249 4 роки тому +1

    In Orlando Florida what R value should I have for flex?

  • @joezavala4606
    @joezavala4606 6 років тому

    Where can I get the wide openning supply grills some supplies only have the small .

  • @patriciahouston-martinez6858
    @patriciahouston-martinez6858 7 років тому

    Hi David,
    Great video!
    We had an Aprilaire humidifier over our heater. It was on one side of rectangular insulation.
    We removed this humidifier because of moldy smell.
    We cleaned well and covered the hole temporarily. Smell is gone!
    But, now I need to get the house appraised and I want the patchwork to look more professional.
    The hole is about 18” x12”
    What is the best material to patch it?
    Thanks for your help!

  • @harvortiz4756
    @harvortiz4756 4 роки тому

    Question, Should the supply air be in the ceiling? or below in the hall?

  • @iwiredit
    @iwiredit 5 років тому

    At the end of the video you said a woman had to turn her thermostat down to 74 and you change the grills and she was able to turn it back to 78 degrees. That's good that those grills improved her airflow that well she must have really had some serious issues, but In no way shape or form is 78 degrees cool in any house. Maybe for an old lady that's in her 80s. I have an 18 seer 3 ton 2 stage condenser that pulls humidity out tremendously well. My thermostat stays at 72 with around 46% humidity in my house in July and August. That's doing the job rather well and it's comfortable for me. If I set it at 74 / 75 with my condenser would be a little higher energy saving and more comfortable for most everyone else such as guest. 78 degrees and up on a thermostat is just not comfortable cool in a home and would only be for an old woman with poor circulation. My grandma is 82 years old and likes it at 78 to 80 degrees in her house in the summertime.

  • @Lilmiket1000
    @Lilmiket1000 7 років тому +1

    I have a 2.5 ton system in a 870 sqft house. 3 of the registers are ok. but 1 of the registers are noisy closest to the supply. and 2 of the registers don't get much air flow and the air is much warmer than the other 3. all on 6in. flex duct. i'm not sure about the size of the return. duct but the grille is 14x24 (what are your problems with this?)
    1950's house with no insulation. im assuming thats why the tonnage is so high for the house size.

    • @bluecollarmillionaire4life
      @bluecollarmillionaire4life  7 років тому

      correct on the tonnage, sounds like it very ubdersized
      put most of the air out furtherst from the return.
      to get good even temp
      thanks for watching

  • @marlymar4
    @marlymar4 4 роки тому

    what is the name of that flexible duct calculator and where can I purchase one? Thanks

  • @otienothomas5841
    @otienothomas5841 2 роки тому

    how marketable is this course

  • @filitamayo
    @filitamayo 4 роки тому

    Hi David, I was wondering if you could help me size my addition . I want to use a roof top unit but seeting on the side instead of on the roof. Please let me know. I can give you more details if you do have time to help me out . Thank you for the info you provided on this great video.

  • @TheByers1
    @TheByers1 4 роки тому

    i'm looking for any information on maintaining static pressure on my trunk as i take off runs seems crazy to reduce after every run

  • @bwhitney61
    @bwhitney61 4 роки тому +1

    I have a 8*14 room what size duct for supply and return

  • @bxx7666
    @bxx7666 Рік тому

    Great stuff

  • @ramsngt3069
    @ramsngt3069 7 років тому +1

    amazing thank you so much

  • @jimacheson4933
    @jimacheson4933 5 років тому

    This video helped, thanks!

  • @cyrusIIIII
    @cyrusIIIII 7 років тому +2

    Thanks for the videos. Why do you read 0.1 friction loss? and then you used 0.4..... why based on what?

  • @TomKaren94
    @TomKaren94 7 років тому +5

    ... and if I'm not using flex?

  • @timothyanthony83
    @timothyanthony83 4 роки тому

    Love it love it

  • @airplane247
    @airplane247 7 років тому +3

    what size melt main duct for a 2.5 ton 1200 square feet house for both sides on a package unit heat pump??

    • @jonwillard3198
      @jonwillard3198 3 роки тому

      18 by 10 splitting into 12 by 10 each way off the split , then reducing to ten by ten each way. Leaves plenty of airspace for 1000 cfms. Depends on the unit too. I've seen alot of chicken shit looking bowers with a frigging tiny tiny opening for the supply. We can thank the white collar world for that one, more engineering jobs had to be created for all the graduates, so God damn, common sense and what was a bit cheaper went out the window, and every thing went digital board and techie, which makes it cost way way more. I even saw an American standard unit with a chickenshit looking blower opening. So they're telling you to attach a duct four times the size of the blower opening. Bull shit. No techie fucker is gonna tell me it blows air thru that duct like an opening three times that size. The engineers probably cut costs to maximize profits there. So good luck in today's times of " fuck a good job and good work, I gotta make mine, and also the created engineer jobs where everything had to be revamped so newbie graduates have a white collar job". Oops, sorry for the rant. But things would be simple, men would take more pride n their work, etc. If uncle Sam ddnt have to create jobs for all the newborns because women gotta be a mom two three or four times.

  • @frankgall6
    @frankgall6 Рік тому

    Set that duct sizing calculator on fire and do a manual j and d! These are our professionals. We’re f’d

  • @Sctronic209
    @Sctronic209 5 років тому

    Is there a specific place to purchase the Ductulator you are using?

  • @deanmartin1966
    @deanmartin1966 7 років тому +1

    Great video

  • @Onelovej
    @Onelovej 7 років тому +1

    great info thanks

  • @johnathanhardee6953
    @johnathanhardee6953 6 років тому

    Is there a ever reason to not insulate flex ducting in between floors? Ive lived at my house in Virginia for 2 years. Its about 20 years old. I just discovered 2 sweat spots coming from uninsulated flex tubing in the downstairs ceiling. The HVAC system inside and out are 3 years old and in great shape. By cutting holes in several ceiling areas ive noticed that all of the duct work in the 1st floor ceiling is uninsulated while the unit in the attic is insulated and installed to a high quality.

    • @richardwoeckener7936
      @richardwoeckener7936 5 років тому

      Always use insulated flex duct... no exceptions.... all ductwork should be insulated!! Including return !! Some others will cut corners or tell ya the return duct doesn't need to be insulated...

  • @darlingtonheatingandcoolin7037
    @darlingtonheatingandcoolin7037 5 років тому

    Hey can you do a video on sizing cans and grills? Thanks

  • @khubbify
    @khubbify 5 років тому

    A great video, thanks for sharing. Would you know of someone in the Hobe Sound/Stuart area that has the same expertise as you? It is only a 2000 sf house but it is miserable to try to cool it and I know ducting is 80% of the issue.

  • @steevebarthelemy8724
    @steevebarthelemy8724 5 років тому +1

    Sa sa ye la ki santi rans sèk konsa ? Kisa ki aluminium carbide la ? Poukisa yo mete aluminium nan system nan ? Yo pa konen aluminium ak plon se bagay ki dezentegre vit ki pa janm dwe chofe trop paske l'ap gaye an poud gaz nan tounen moun ? Se krack moun vini pran isi ?

  • @york57
    @york57 7 років тому

    Mr. Jones you are a HVAC genius. I am one to try doing stuff myself because I can never afford a to hire someone. Well we are building a small rancher in WV. after getting sick from west Nile virus I had to go out from work. My current home we are gonna rent out because I honestly cant afford to live in it anymore. It is gonna take awhile to do but Im trying to do most myself. We just had it framed so its wide open. The plan is to begin framing the interior and start roughing it in electric plumbing and hvac. I prey after watching your videos I can mange to do my own ductwork. Its a 32X44 rancher and I want to run flex line . I did a layout on my laptop and have the location for the furnace . Do you think there is anyplace I could go and they could tell me what I would need in regards to the sizing of material needed Flex Line Returns etc.if I were to buy from them.? Im not sure if any place would do that.The tool you used was very informative but I have never used one before so there is alot of learning. In the meantime Im going to look for more of your videos . Thanks you

    • @vinnymac8127
      @vinnymac8127 7 років тому +1

      An HVAC supply house isn't going to tell you how to size your duct system. You need a proper load calculation done on the house, which will size your system and ductwork based on square footage, windows, insulation, etc. I've been an HVAC installer for 15 years and it took me several years to be able to properly design a duct system. My advice to you is to hire a professional before you fuck it up, and I'm not trying to be rude, I'm just being honest with you.

  • @DCruzful
    @DCruzful 4 роки тому +1

    Hey David, Thanks for the video and your time. Quick question if I change my 16 Sears A/C UNIT to a 20 Sears do I need to change my ductwork?

    • @hangngoaigiare
      @hangngoaigiare 4 роки тому +1

      Pastor David Cruz no the ductwork has nothing to do with your furnace efficiency. Ur duct size will determine how many cfm you can deliver to your room.

  • @saw837
    @saw837 7 років тому +1

    Can i ask u a question couse here in florida no body can give me a answer why i have some two room that is always hot

  • @salazajf
    @salazajf 7 років тому +2

    Great job on the video. Very thankful for you to post this. Question. How do you calculate splits on supply ducts? And whats the difference metal vs triangle duct-board wyes?