How to Fit an Isolation Valve on Copper Water Pipe

Поділитися
Вставка
  • Опубліковано 16 вер 2024
  • Isolation valves are a wonderful thing and Roger loves fitting them wherever he can. You might recognise this boiler room, it's the fourth episode we've shot in here. This job takes a while so you'll also get a bit of Roger's insight, some gripes, plumbing history and general musings from a man that has much to share with the audience that he loves.
    Isolation valves or service valves are a life and time saver. We'll show you how to fit an isolation valve to copper water pipes so that your appliances can be disconnected from the main water supply quickly and easily.
    We prefer an isolating valve with a handle and the one used in our video is an Intaball Lever Ball Valve with red handle from Altecnic Plumbing and Heating Supplies.
    #plumbing #boiler #DIY
    ===================================================
    Don't forget to stay up to date with Skill Builder!
    Get in touch and send us your pictures and videos - skill-builder.u...
    See our Tweets - / skillbuilderuk
    See our Facebook Page - / skillbuilderchannel

КОМЕНТАРІ • 238

  • @neilphilip2320
    @neilphilip2320 Рік тому +4

    I'll give you a life supply of pipe cutters if you convince my wife that all she needs to do is select one (or more) of her multitude of jumpers when it get gold outside. I'll even provide you with suitable safety gear for your visit! Brilliant channel.

  • @leehotspur9679
    @leehotspur9679 Місяць тому

    Just started doing a bit of Reno work here in NZ Thanks for all of your vids always instructional and interesting Thanks again Roger

  • @windspoint
    @windspoint 3 роки тому +20

    It might seem a bit obvious but to us less confident it would be nice to see an example of how best to measure the fitting for the amount of pipe to cut out to accommodate the valve!

    • @Paul_707
      @Paul_707 Рік тому +10

      Use a couple of pieces of off cut pipe, say 150mm long each. Insert them into the valve and measure the total length. The excess over 300mm is the figure you need.

  • @chrisf5475
    @chrisf5475 2 роки тому +1

    Found this to get some info… didn’t expect to be so entertained. Brilliant 😄

  • @johnabbiss43
    @johnabbiss43 Місяць тому

    Thanks 🙏 for sharing this with us 👍🏻

  • @wetpaints8490
    @wetpaints8490 5 років тому +4

    Love watching skill builder vids. Taught me how to solder. Just fitted two new radiators in my extension, SDS chiseled my floor up, layed two new pipes, plumed everything together. Probably didn’t save money as had to take time off work to do it. But.....having a new (talent is the wrong word) talent is awesome 😎. Cheers big man. Have you got a “Patron? Account, you should get one.

  • @harryham1
    @harryham1 5 років тому +5

    Love that Life of Brian reference that the cameraman managed to slip in there.

  • @flycow69
    @flycow69 5 років тому +4

    Greetings from New York City. Good work, love the accent.

  • @paulross7204
    @paulross7204 5 років тому +5

    I sit behind a desk all day. That was like therapy I could watch you all day long, in fact most enjoyable thing I’ve seen today. Can you put those valves on potable supplies. I use ball valves but they tend to weep over time.

    • @djyul
      @djyul 5 років тому

      It is a ball valve

    • @SkillBuilder
      @SkillBuilder  5 років тому +5

      Yes they are good for high pressure and potable supplies. The cheap ball valves are a liability but lots of people fit them just to tick a box. Then it is somebody else's problem.

    • @m.o.2085
      @m.o.2085 4 роки тому +1

      @@SkillBuilder Amen! They should be outright banned, no wonder you can't find them anywhere in Europe. Is it another UK novelty? Utterly useless.

  • @TheAudiostud
    @TheAudiostud 5 років тому +4

    Roger! You wouldn't last five minuets on my site! You'd probably spend all day looking at my eclectic hoard of videos! Thanks for another cracking shorty Skill Builder Team Great Work Well Done!

  • @berkayultraslan1
    @berkayultraslan1 5 років тому +2

    I love that ptfe technique around that olive

  • @Maker76
    @Maker76 5 років тому +1

    Guys, finding your channel really useful, easy to follow and I assume would offer the diy'er lots of confidence to tackle the simple stuff. Keep it up, I'm really enjoying your videos, working my way through the them.

  • @zedman442
    @zedman442 5 років тому +5

    Little PTFE round an olive goes a long way. Lived by that for years. Like you believe in helping the next person out. I also put in a isolated loop with one radiator to a combi boiler so you can drain down but keep hot water on for the customer.

    • @williammcgrattan9583
      @williammcgrattan9583 5 років тому

      Or a little bit of Hawk White paste would be equally just as good. It's good stuff.

  • @tedfusco3472
    @tedfusco3472 Рік тому

    . Thanks, you just solved a problem . I didn't know they made ball values with compression fittings. Now I won't burn down my house trying to solder one in.

  • @london_roubenl
    @london_roubenl 3 роки тому

    Really enjoyed this video, thanks for your knowledge and time.

  • @the-colonel9809
    @the-colonel9809 5 років тому +1

    Always enjoy the videos Roger keep up the good work

  • @stephenhodges4933
    @stephenhodges4933 4 роки тому

    great stuff simple and straight forward but hints at problems others may get

  • @chloehelliwell
    @chloehelliwell 3 роки тому

    Really enjoying these videos, Thanks Roger!

  • @Alan_Edwards
    @Alan_Edwards Рік тому

    I am adding isolation valves for my 1st floor shower in preparation for a bathroom remodel. I normally would sweat in a valve, but there is no way I will be able to fully stop the water flow so going with compression valves makes sense and it sure looks a lot easier. I have never seen anyone put Teflon tape on the compression ring, but since I am concerned about leaks I think I will give it a go. Thanks mate.

  • @BHANGUVIDEOSUK
    @BHANGUVIDEOSUK 3 роки тому

    Great man! I learning lot from your videos. You are Clint Eastwood of "PLUMBWOOD".

  • @iameccles
    @iameccles 5 років тому +4

    the cameraman questions are a nice twist from the norm. "hidden depths lol"

  • @StephenSmith-yy5xx
    @StephenSmith-yy5xx 4 місяці тому

    I searched for how to fit a compression valve into a run of pipe. But with one end loose, its the same as fitting a valve onto new work - thanks for showing the PTFE tip, so I learned something. I'd really like to see how to fit one in a run of pipe where there is no play in one of the ends of piping.

    • @SkillBuilder
      @SkillBuilder  4 місяці тому +1

      we will do that, we have a solution

  • @jerrymcg3199
    @jerrymcg3199 4 роки тому

    Great video.
    You are the only one on YT to show it being done on an installed pipe. All the videos on YT show valves and compression couplings being fitted onto loose pieces of pipe on a bench.
    A child could do that. The problem is where there is no give in the pipe.
    I have been trying to find how to insert a piece of copper pipe between two compression fittings to join two pipes with no give, without success.

    • @SkillBuilder
      @SkillBuilder  4 роки тому +1

      You need a slip coupling. They are available as repair couplings solder or compression.

    • @jerrymcg3199
      @jerrymcg3199 4 роки тому

      @@SkillBuilder Thank you for the reply. My problem is that my pipe diameter is 18mm and I've searched but never found slip couplings in that size.

  • @robmarrin6720
    @robmarrin6720 4 роки тому

    My name is robin and it means work's with water, and I was an alarm engineer and became a creator of exquisite bathrooms as yourself,, I'll send some pics to your link below 👍the irony is I've worked with water for 15 years now after 12 in alarms, and only two years ago did I discover what robin means😂😂

  • @ratchriat1716
    @ratchriat1716 5 років тому

    in my opinion a lever ball valve they are the best easy and safe to use enjoyed the video.

  • @williammcgrattan9583
    @williammcgrattan9583 5 років тому +1

    Good job Roger 👍

  • @nickcollins7568
    @nickcollins7568 5 років тому +7

    Those full bore lever ball valves are brilliant. I have long since given up fitting gate valves. They are way too unreliable as they invariably leak or let by!!!

  • @dannechita8577
    @dannechita8577 Рік тому

    something new learnt today. cheers

  • @stephenhookings1985
    @stephenhookings1985 3 роки тому

    Great tip on how to "flow" the PTFE onto pipe. And I always wondered how to fit the into existing pipework - now we know.

  • @beneveleigh8840
    @beneveleigh8840 3 роки тому

    Excellent plumber

  • @karimabdullah2925
    @karimabdullah2925 5 років тому

    love this guys videos. Highly entertaining guy

  • @lovingitandlife
    @lovingitandlife 2 роки тому

    always enjoy your videos,as a carpenter i've always asked plumbers how to do things and they have been always helpful. i notice you put ptfe tape on the pipe,i always thought and done it on the thread,have i been doing it wrong,did like your way though.thanks, mark.

  • @paulashford7509
    @paulashford7509 5 років тому

    Good videos for someone like me, who knows very little....

  • @robmarrin6720
    @robmarrin6720 4 роки тому +2

    Sheer class, if you don't have luck you need money ❤️👍

  • @240soundwave
    @240soundwave 5 років тому

    PTFE tape, Truth to Power. Praise!

  • @Chanesmyname
    @Chanesmyname 5 років тому +1

    Actually, now I've watched the whole video, the Aladin isolator would have made your life far easier. :)

    • @markroper6188
      @markroper6188 5 років тому

      Chanesmyname they are good when you have no other option- but £40 vs a fiver... plus the system was drained down

    • @Chanesmyname
      @Chanesmyname 5 років тому +1

      @@markroper6188 I know that price difference is chunky but saving the trouble of draining down and for the speed of the fit and for a one off item, I like the ease of it and I think there is less than go wrong with the fit too - no undue pressure on pipe lengths to tweak at other joints when flexing them to fit into the pipe cut out...no pipe slice either. :) Lazy and lacking great skills I admit it and that aladin valve is best for me as an odd job and not a being a well-skilled plumber. :)

  • @SuperTannoy
    @SuperTannoy 5 років тому

    Very informative, very amusing, love it.

  • @johndowney8713
    @johndowney8713 3 роки тому

    Great videos.

  • @mango3586
    @mango3586 5 років тому

    all your videos are interesting sir

  • @johnriggs4929
    @johnriggs4929 3 роки тому +3

    PTFE tape on olives... "Nah, you don't need to do that..."
    You do if you buy 'em from Screwfix

    • @mr.d7372
      @mr.d7372 3 роки тому +1

      Totally agree. PTFE very amateurish. But where does one buy good olives these days?

  • @alanmullock381
    @alanmullock381 5 років тому +2

    Oooohhhhh! Spanner envy!👍👍👍👍👍👍👍🤣🤣🤣🤣🤣🤣🤣🤣

  • @roybatty2030
    @roybatty2030 8 місяців тому

    Ensure the valves are full bore and check if they have an arrow for flow direction.
    I usually tighten the fittings, loosen them off and apply PTFE then finally retighten.

  • @grrinc
    @grrinc 5 років тому +4

    Question Roger.... are there standards that need to be taken into account when fitting isolating valves onto central heating systems? Ta.

  • @uffiserviceuk5377
    @uffiserviceuk5377 3 роки тому

    Nice channel 👍

  • @declan3906
    @declan3906 3 роки тому +3

    "In classical Greece, "speaking truth to power" was known as parrhesia. ... Noam Chomsky is dismissive of "speaking truth to power". He asserts: "power knows the truth already, and is busy concealing it"."

    • @grotekleum
      @grotekleum 3 роки тому

      I think Noam Chomsky is right.

  • @carguillo1
    @carguillo1 5 років тому

    Hi Roger its kev love that spanner take care mate

  • @stakkerhmnd
    @stakkerhmnd 5 років тому +1

    1st. Firsted. Fit an isolation valve on copper water pipes ! You know it makes sense !

  • @marcck5597
    @marcck5597 5 років тому +2

    Offset the valves. Use jointing compound. Mark the pipe before you cut. The full bore lever valve handles should always fall into the off postion, against the flow.
    If your gonna show someone how to do something, do it right. For there benifit.

    • @prplumbing7869
      @prplumbing7869 5 років тому

      If you are getting on your high horse then learn to spell right you illiterate troll

    • @ciaranamhain
      @ciaranamhain 2 роки тому

      Agreed except I don't think I'd want a valve falling to closed on a heating circuit.

    • @endurojimmy3109
      @endurojimmy3109 Рік тому

      @@ciaranamhain I've worked in boiler houses for about 30 years.
      All lever op valves must fall to close, any valve which has the potential to cause damage to a system would be lockshield or similar.
      In fairness there's so many safety interlocks nowadays that any closed valve would protect and stop the system anyway.

  • @pooleheating
    @pooleheating 5 років тому +2

    The lever valve unlike a ballofix doesn't have a direction of flow as being a lever valve it should always fall to close.

  • @gdfggggg
    @gdfggggg 5 років тому

    Push fits mate, Bosh, owzya fava 👍🏻

  • @dansmith436
    @dansmith436 5 років тому +13

    2:47 .. cant be the only one who saw the monkey in top left corner ? :O

    • @alwoolhouse6255
      @alwoolhouse6255 4 роки тому +1

      Blimey Charlie but you’re right. SkillBuilder does Easter Eggs!

    • @markeverson1385
      @markeverson1385 4 роки тому +1

      i can only see a one Monkey. Robin is better on his own.

  • @jamesdooley713
    @jamesdooley713 4 роки тому

    Well Roger , im a carpenter with no plumbing experience but i want to learn, what videoes should i start watching of yours to learn as much plumbing as possibel off of you?

  • @steveprice9462
    @steveprice9462 5 років тому +5

    Hi, how did you decide how much of the copper pipe to cut out? Thanks.

    • @88CBAUGH
      @88CBAUGH 3 роки тому

      I was wondering about that myself.

    • @broadwayFan28
      @broadwayFan28 3 роки тому

      I'm at the same point. I need to know how much copper to remove from 3/4" copper pipe before installing the ball valve. Worse, it runs through joists that are 2 feet apart.

  • @chrisharries2463
    @chrisharries2463 Рік тому

    How wide is the gap between pipes then.

  • @ThePhilandPam
    @ThePhilandPam 5 років тому +3

    I used to use ptfe on the olives but now use Jet Lube V-2 Plus, never had a leak yet, any experience of this or thoughts?

    • @mp9748
      @mp9748 4 роки тому

      TheP Jet lube is the way mate. PTFE on a olive is bad news

    • @roybennett206
      @roybennett206 3 роки тому

      @@mp9748 why is PTFE bad news ?

  • @robmarrin6720
    @robmarrin6720 4 роки тому +1

    Have you got a link to the nut spanner used on the lever valve's 👍❤️ great workmanship, or workpersonship but that sounds strange man, 😂👍❤️

    • @88CBAUGH
      @88CBAUGH 3 роки тому

      It's a split ring compression fitting spanner 15mm / 22mm. On Ebay for about £12, or Amazon for a couple of quid more.

    • @kevwade63
      @kevwade63 2 роки тому

      Toolstation £8

  • @roberthatcher2773
    @roberthatcher2773 5 років тому

    Should I change all my 30 year old Gate Valves for Lever Valves on next drain down of Hot/Cold and CH? - Some Gate Valves stiff as hell to turn!

  • @LewisCowles
    @LewisCowles Рік тому

    What do you think about the self-tapping Aladdin isolators?

  • @espenklingsheim978
    @espenklingsheim978 5 років тому +6

    You would be welcome on my site.

  • @bahopik
    @bahopik 5 років тому +1

    How do you guys bend pipes like that? Never it seen it before, do you anneal s section or something? Nice pipe hangers by the way I wish these were available to me

    • @SkillBuilder
      @SkillBuilder  5 років тому

      We will make a video on bending pipes.

  • @loafersheffield
    @loafersheffield 5 років тому

    "Picking up the wrong end of the stick," is derived from Roman plumbing. They would have communal latrines with streams diverted through two channels. One for sitting over to flush through the poo etc and another into which they would dip a stick with a sponge tied to the end for washing ones derrière. Then the stick/sponge would be put back down for the next bloke to pick up... and then the next... and then the next and so on.

    • @JuiceBanger1
      @JuiceBanger1 3 роки тому

      The rule of thumb comes from, don't use a stick thicker than your thumb, to beat your wife.....

  • @xxSweetStrangerxx
    @xxSweetStrangerxx 3 роки тому +1

    Do you need permits to do this job?

  • @samacochan
    @samacochan 4 роки тому

    At 1:35 you are cutting some pipe to install a ball valve, how much did you cut off ? What's the measurement ? Thanks

  • @MontyVideo969
    @MontyVideo969 5 років тому +1

    I noticed you wound the PTFE tape (@3:30) the same way for both the left and right olives - doesn't that mean that the right hand tape is going to "undo" when you tighten your nut?

    • @SkillBuilder
      @SkillBuilder  5 років тому +1

      Hi Patrick
      The olive doesn't move as the nut is tightened so there is no tendency

    • @bigdavey69
      @bigdavey69 4 роки тому

      Real plumbers don’t use ptfe on olives we use jet lube

  • @bikerchrisukk
    @bikerchrisukk 5 років тому

    great video again, i wonder what you think and what you've heard of about those isolating valves that clamp on and pierce the pipe? I know they're only supposed to be for jobs where you can't turn off the mains water but would still be interested in your thoughts. Cheers !

  • @THECARKUS
    @THECARKUS 5 років тому

    Roger... Dude, that pipe slice is causing me anxiety :-) You need to change that wheel... And Bahco is my favourite. Their adjustable spanners are the kings! Love your work. Thanks yet again!

    • @SkillBuilder
      @SkillBuilder  5 років тому

      I slung it in the bin. Got a new one. Happy days

  • @bigbadgaz1
    @bigbadgaz1 3 роки тому

    8:35 Monty Python reference , nice :)

  • @angelinthedocks3732
    @angelinthedocks3732 5 років тому +2

    P.T.F.E on the olive is fine but wrapped around the thread on a compression fitting is fairly pointless imo. Fernox LS-X and hawkwhite both have their place.

    • @SkillBuilder
      @SkillBuilder  5 років тому

      Swanseal is my favourite gunk

    • @whitacrebespoke
      @whitacrebespoke 5 років тому

      I did a kitchen in the summer and client did their own plumbing all with compression fittings I think he must have used about 5 rolls of tape. Olives threads the whole works all taped up.

    • @williammcgrattan9583
      @williammcgrattan9583 5 років тому

      I'm a jet lube v2 man, coz I'm special. Lol

  • @WilliamSiggery-oq8lx
    @WilliamSiggery-oq8lx 3 роки тому

    Roger what do you know about cracks in walls on extension how to fix

  • @cskeise
    @cskeise 4 роки тому

    ROGER...💙👊😃🔧

  • @dhuryodhankaurav8487
    @dhuryodhankaurav8487 10 місяців тому

    The valve doesn't need any threading on the pipe?

  • @yensabi
    @yensabi 5 років тому

    Why not freeze the pipe Roger instead of draining a large system down and then having the hassle of bleeding a dozen rads , that's what I would do , I've got a couple of those open ring spanners and I agree they are brilliant also Kopex make the best pipe slices I have ever used
    Cheers mate....👍

    • @SkillBuilder
      @SkillBuilder  5 років тому +8

      Yensabi, I have done a bit of freezing in my time but I was removing the old towel rail and re-routing the supplies. I couldn't lift the floor so I did the whole job at arm's length with some push-fits. These jobs are stressful enough without putting myself under extra time pressure. The time I froze a mains pipe and went out to the van for the spare gas canister and the van had been towed away still lives in my memory.

  • @hectorheath9742
    @hectorheath9742 3 роки тому

    what about the burrs your blunt pipe cutter leaves behind?

  • @fablan3308
    @fablan3308 2 роки тому

    Can I use one of them instead of a mains tap

  • @djyul
    @djyul 5 років тому +3

    Bacho in Holland is a Bacardi cola :)))

  • @MT_T991
    @MT_T991 5 років тому +1

    What's your main interest outside of plumbing

    • @SkillBuilder
      @SkillBuilder  5 років тому +8

      Cycling; since I was 11 I have ridden my bike all over the place.
      Reading. I probably only read around 20 books a year but would love to read more and have a lot stacked up for my retirement.
      Rock climbing but I do less than I used to.
      Travel. I love to go anywhere.
      Camper Bus We go away abroad in the camper bus about 5 times a year and that always involves a lot of cycling.
      Photography I take lots of pictures for magazines and i would love to be better at it

  • @letsgocamping88
    @letsgocamping88 5 років тому +5

    You’re sounding like an electrician.

  • @ianjonas7925
    @ianjonas7925 2 роки тому

    Hi Roger, out of pure interest, and I know the unit is a fairly costly initial outlay, but why do many plumbers not use one of the lovely Rothenburger Pipe Freezers?
    I've used one a few times before to replace radiators and they are a godsend in terms of speed.

    • @SkillBuilder
      @SkillBuilder  2 роки тому +1

      I have used the electric freezers but most of the time there are ways and means that are straightforward.

  • @mansoorhussain1797
    @mansoorhussain1797 4 роки тому

    Can you do a video on traps

  • @declansmith1692
    @declansmith1692 2 роки тому

    Not put uni white on rings?

  • @vicventurini3786
    @vicventurini3786 3 місяці тому

    V2 plus on any compression fittings involves water! Not PTFE!

  • @unknownmale
    @unknownmale Рік тому

    I'm replacing the radiators on one floor and want to put some lever valves in so I can shut down the flow and return on that floor and have the heating for the rest of the house up and running while i modify the pipe work up to the new radiators, might take a week or so with the additional work to the walls/plaster etc. Is there any reason I can't use these valves for this purpose? It's a big house and takes a long time to drain down!

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      Hi David
      That is precisely what they are used for so long as the system is unvented

    • @unknownmale
      @unknownmale Рік тому

      @@SkillBuilder Thanks for the reply! It's a vented system

    • @unknownmale
      @unknownmale Рік тому

      @@SkillBuilder SHould I use gate valves for an F&E system

  • @Chanesmyname
    @Chanesmyname 5 років тому +1

    Could you have fitted an Aladin isolator valve? You can use them on live feeds too.

    • @Razz60
      @Razz60 4 роки тому

      They cost about £50

    • @800Viffer
      @800Viffer 4 роки тому

      @@Razz60
      How much would it cost for an engineer to drain down and refill the system with another dose of inhibitor?

  • @1xstew
    @1xstew 3 роки тому

    I have to fit an external expansion tank to my combi boiler, so I know I need to put a Tee in the return pipe to the boiler to feed my new expansion tank.
    I don't want to drain the system.
    Can't I buy a freeze kit and freeze the pipe below the Tee and close off the isolator to the boiler above the Tee so only a small of water will spill out the bit of pipe below the isolator valve.
    Be easier to draw a diagram I know . . Tried to be as descriptive as I can!

    • @SkillBuilder
      @SkillBuilder  3 роки тому

      You can buy a tee that is made for this very job. It makes a tiny hole in the pipe and that is plenty to allow the expansion vessel to work.

    • @1xstew
      @1xstew 3 роки тому

      @@SkillBuilder That will save me a lot of work . . What exactly do they call this Tee? Are they on eBay?
      Thanks for this.

    • @stewartc3954
      @stewartc3954 3 роки тому

      @@SkillBuilder Hi again . . tried searching for thisTee but cant find it. Please help. Stewart

  • @seanditch4419
    @seanditch4419 Рік тому

    Hiya, How did you know how much pipe to cut out please?
    thank you for this video.

    • @amg863
      @amg863 Рік тому

      He didn't. If you watch the video he plays with the pipe to give himself more room to fit the valve in. When it doesn't work, he cuts off a tiny bit more.
      Trial and error. Push the pipe as much as you can or cut off a bit more.

    • @seanditch4419
      @seanditch4419 Рік тому

      @@amg863 Exactly, so he must've known how much extra he needed to cut because he first lined the valve up to check, which is why i asked
      "How did you know how much pipe to cut out?" I'm guessing trial and error isn't something that you can do too often before you knackering the job up.

    • @amg863
      @amg863 Рік тому +1

      @@seanditch4419 it doesn't have have to be super precise. just cut a little and try again if you still don't have enough room. If you cut too much by accident you can always buy a length of 15mm copper pipe for less than a tenner and patch up the gap.
      Or if you're really worried about it, you can buy self-cutting isolation valves which are pretty much fool-proof but I don't think plumbers will recommend them because it's not the "proper" way to do it but it worked for a lot of diyers.

    • @seanditch4419
      @seanditch4419 Рік тому +1

      @@amg863 Ahhhh right, great stuff, i thought he was measuring an exact precise distance between two points on the valve.
      I've seen those Aladdin self cutting valves and was told that they themselves would only use them in an extreme emergency, because apparently they fail quite quickly.
      Thanks for your help clearing that up for me....👍👍👍👍👍👍👍👍

    • @amg863
      @amg863 Рік тому +1

      @@seanditch4419 I have a self cutting valve for an outdoor spigot that's been there since before I moved in and it hasn't leaked yet. It reduces the water pressure a little bit though. It's not as good but it's not bad either.
      Cheers

  • @vistron888
    @vistron888 5 років тому

    On the original internet talkboards was a DIY group. Was a little clique that thought they ran the place & the usual forum sycophants. They would always bleat on about how you shouldn't use PTFE tape, it should be a cold weld..etc etc. Any other view was shouted down. Kind of people who would argue with a wall.

  • @ahinesbm9105
    @ahinesbm9105 3 роки тому

    Hello Roger i have question when i put thw water on in the bathroom and turn the water on in the kitchen the pressure is droping can it be fix ?

    • @SkillBuilder
      @SkillBuilder  3 роки тому

      You can only get out what you put in. If the pressure is low on the mains you won't get much out. Have you got a combi boiler?

  • @RosskillbaneC
    @RosskillbaneC 5 років тому

    Do you have the qualification for an unvented cylinder

  • @calsitup
    @calsitup 3 роки тому

    I noticed you put the ptfe tape on same way as the direction of nut on the left. Then did the same on the right olive opposite direction of the nut. Is this normal ?

    • @SkillBuilder
      @SkillBuilder  3 роки тому

      It doesn't matter because it is on the olive and the olive doesn't turn

  • @craig5832
    @craig5832 2 роки тому

    What's with the gorilla in the top left corner at 2:47 ? I thought I was seeing things 🤣🤣

  • @pkfan5112
    @pkfan5112 2 роки тому

    There are a lot of room. Why put two Valves in the same place?

    • @SkillBuilder
      @SkillBuilder  2 роки тому

      I like having motorised valves in line and I am not alone in that.

  • @GrahamOrm
    @GrahamOrm 5 років тому +1

    PTFE always a good idea on brass olives, they're crap. I don't do it with copper olives. Buy a new pipe slice you old miser! EDIT: Ha! Still watching, just got to the comment about the pipe slice being worn out. Could have put a new system in waiting for it to cut!
    Putting the screw in your mouth: Fitting a loo for an old couple, floorboards soaked in piss. Drilled pilot holes for pan screws and switched drill bit for screw driver bit, put the drill bit in my mouth and thought, hmmmm that's salty! 30 Years ago, never forgotten it.

  • @redwarrior260
    @redwarrior260 Рік тому

    Don’t you have to deburr the ends of the pipes that are cut?

    • @SkillBuilder
      @SkillBuilder  Рік тому

      I never deburr and I don't know any plumber that does. Imagine the miles of pipe I have installed all wrong

  • @isyt1
    @isyt1 5 років тому +8

    You’d get thrown off my site! But only because you make everyone else look bad

  • @cglees
    @cglees 4 роки тому

    Roger, love your work. Quick question...I’ve been fitting isolating ball valves on all of my pipework during my bathroom refit that I’m doing. They work for me. Anyway I’ve been told that they will reduce the flow and I should have used full bore valves like you have in this video. Some of them are for my new bath, sink, toilet etc. Should I replace them all before it’s too late? Thanks in advance, Chris.

    • @SkillBuilder
      @SkillBuilder  4 роки тому +2

      Hi Chris
      The problem with isolating valves is that they weep around the glands unless you spend a lot on them and when you spend a lot they tend to be full bore. Most plumbers I know wouldn't touch an isolating valve when carrying out a repair or service. You go in to service a tap and end up having to drain down and replace the valve.
      Now they are in I would leave them. If you have mains pressure they won't slow the flow much, if it is tank fed you might want to remove them on the shower and fit full bore.

    • @cglees
      @cglees 4 роки тому

      Thanks for the swift reply Roger! So far I have just removed the old suites and put the isolating ball valves on so that I could refill the system for the rest of the house. It’s not too late, I could drain down again and remove them when I fit the new suite. I’m going to fit the abacus wall mounted system and will have a gasket like in your video to individually control each service for future maintenance.
      I had no idea the ball valves were so unreliable.
      It’s not mains.
      What about if I drain down again and fit full bore gate valves on my hot and cold feeds?

  • @rimmersbryggeri
    @rimmersbryggeri 5 років тому

    BAcho is now owned by Snap On.

    • @sadiqmohamed681
      @sadiqmohamed681 5 років тому

      And the other company, projectors and video monitors, is BARCO. I think they are Finish.

  • @hinguyen9584
    @hinguyen9584 3 роки тому

    What is the brand of this valve?

  • @Weizel88
    @Weizel88 3 роки тому

    What about deburring the inside of the pipe you have cut? 🤔

    • @SkillBuilder
      @SkillBuilder  3 роки тому +1

      I don't know anyone who does that.

  • @k20aa
    @k20aa 5 років тому +4

    Christ by a new 22 slice lol

    • @SkillBuilder
      @SkillBuilder  5 років тому +2

      I have one but this one keeps surfacing. I know it is wrong but with me it is all about the hardship.

    • @k20aa
      @k20aa 5 років тому +1

      I know the felling I can always find the crap one in my tool box . The new one always hides @@SkillBuilder

    • @SkillBuilder
      @SkillBuilder  5 років тому +3

      @@k20aa
      I binned the old one this afternoon, invested in a new Monument Pipeslice. I can't retire now. Onwards and upwards.

    • @k20aa
      @k20aa 5 років тому

      Good work . Think of the extra years on your wrist lol@@SkillBuilder

  • @Tubekeny1
    @Tubekeny1 5 років тому

    Why not plan how you are going to lengthen the pipe before you cut it?