    If you have no water flow or your hot tub pump is just humming, test your pump capacitor and that just might be the problem.
    👀 Capacitors: Order HERE (CANADA ONLY)
    https: //www.electricmotorsbarrie.ca/
    ❤ SUBSCRIBE - ua-cam.com/users/VIPPoolsand...
    🎁TIP JAR - PAYPAL: info@vippools.ca
    -------------PAID LINKS BELOW-----------------------------------
    ✔ Hot Tub Heater Element (Off Set)
    5.5kw amzn.to/3OpkSOO USA
    4.0kw amzn.to/381p1HD USA
    5.5kw amzn.to/3rBUXtb CANADA
    4.0kw amzn.to/3vw3bV7 CANADA
    ✔ Hot Tub Heat Tube Gaskets
    amzn.to/3JOqu1f CANADA
    amzn.to/381otS5 USA
    ✔ Hot Tub Test Kit:
    amzn.to/3xGeKvo CANADA
    amzn.to/2LOl2nb (small kit)
    amzn.to/3rO71W3 (large kit)
    ✔ Hot Tub Pump Capacitor Tester:
    amzn.to/3JYgfaO CANADA
    amzn.to/3uPw0wu USA
    ✔ Hot Tub Volt Tester:
    amzn.to/36odwJY CANADA
    amzn.to/36v17Ek USA
    ✔ Volts and Amps Tester
    amzn.to/37qsKyA CANADA
    amzn.to/3Mej4Gl USA
    ✔ Pool and Hot Tub Wrench
    amzn.to/3KWmdKI CANADA
    amzn.to/3vtslDv USA
    ✔ Pool O-Ring Lube
    amzn.to/3Eq40mq CANADA
    amzn.to/3KVn2Du USA
    ✔ Pool and Hot Tub Silicone
    amzn.to/3JTkCnA CANADA
    amzn.to/3uRwj9V USA
    ❤ FACEBOOK - / vippoolandspa
    😎 Join this channel to get access to perks:
    / @vippoolsandspas
    #hottubpumphumming #hottubpump #spapumphumming #hottubpumploud

КОМЕНТАРІ • 41

  • @VIPPoolsandSpas
    @VIPPoolsandSpas  3 роки тому +3

    Testing a capacitor is very important.

  • @user-pz9lr5vv2x
    @user-pz9lr5vv2x 2 місяці тому +1

    Great job and advise. Ty

  • @ajaxborges
    @ajaxborges Рік тому +2

    I felt that this video was perfect. And it has given me the confidence to test out my capacitor on a pump that just hums (and won't turn).

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Thanks for the comment. Make sure to Subscribe so I can make more videos.

  • @commentsonthetube14
    @commentsonthetube14 Рік тому +3

    Most multimeters can test capacitance too, so you don't necessarily need a specific tool.
    The unit is micro farads. That weird u (I forgot the Greek name) is the metric symbol for micro. And capital F is farads.
    Thanks for the video! Helped me fix my pump!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Thanks for the comment. Had a brain fart in the video. lol

  • @anxiousbeachbums
    @anxiousbeachbums Рік тому +1

    Yours is the video I've been searching for (found many focusing on the "wet end" when I was suspecting the capacitor). Will start out attempting to spin the motor with a screwdriver (not sure if possible on a 12 yr. old Watkins XP2). Then gloves on, eyes open for black widows and attempting to remove the capacitor. Helpful video.

  • @medium_mike
    @medium_mike Рік тому +3

    Anytime you are handling a capacitor, it is a good idea, after disconnecting the power, to take a screwdriver with a plastic handle and short the contacts by touching them at the same time with it before touching it with your hands. This will remove any standing voltage from the capacitor.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Did I miss that? Thank you.

    • @medium_mike
      @medium_mike Рік тому +1

      @@VIPPoolsandSpas No problem. I was more or less leaving the tip for someone that might be new to the task. It's a really simple trick that can save you from having shaky hands of fear. Sometimes those terminals can be stubborn enough to remove without adding trying to keep from getting shocked to the equation. 👍

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      @@medium_mike my other videos I do say to do that, just forgot on that one. Thanks again.

  • @mickeyrat1297
    @mickeyrat1297 3 роки тому +1

    Good work!

  • @BillyMcCord
    @BillyMcCord Рік тому +1

    My tub is doing exactly this! ... I will pull that CAP and replace hopefully that is my issue.

  • @bumblebee85hastoys
    @bumblebee85hastoys Рік тому +1

    I have the humming when I try to turn the aux on in my tub...I also get a slight odor when I also turn it on, but it just hums...I do not get this metal melting type of odor(hard to describe the smell) when I don't use the aux. I think I need a new compacitor.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      AUX is pump 2 I think. Whatever pump it is, sounds like it's seized or its the capacitor. Unplug the pump or turn the power off right away and test the capacitor. If you can turn the impellor pump shaft, its the capacitor. If you can't turn it, its the bearing.

  • @stevethompson5424
    @stevethompson5424 2 роки тому +2

    I have a hot springs with a wave master 7000 pump that keeps tripping the breaker. It has 2 capacitors though. One on top and at the rear. Which do I change or both. Very hard to get to without draining the tub and removing the pump.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 роки тому

      I would say the start capacitor in the back. But, not sure the pump you have.

    • @anxiousbeachbums
      @anxiousbeachbums Рік тому

      Filling my tub for the winter season and ran into the same problem w/ the same pump (Hot Springs Jetsetter). Guessing it's the capacitor (Power on, large click, breaker pops in 3-5 seconds). Thought shaft might be seized-up but it still spins. Capacitor not doing it's job. Sun went down..........tackling it again tomorrow. Will see if I can spin the shaft with a screwdriver as he did in the video.

  • @flackit0
    @flackit0 Рік тому +1

    My tub is doing the same.!!! I chanche the capacitor but is still doing the same i need spin whit the screwdriver 😢

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Needed to check the impeller first and then test the capacitor. If the impeller spins freely, then the pump is no good.

  • @swedishkev
    @swedishkev 3 роки тому +1

    l have a Rimini spa bad or hotub , that is about 8 years old. I am in Sweden, We noticed a while ago that it did not seem to have full power, when pushed on full power, the flow was weak, everywhere. We also said to ourselves, that we think that we had 2 power settings, you pushed it in and got like 50% bubbles and then pushed it in again for full bubbles. But we only seemed to have one setting now full and off only. I know the pump is 2 speed, says on it. So I took the pump out and took it apart, noticed that the impellor was half missing, all broken, So I thought great was impellor, ordered a new impellor and seals, just the same, pushed the jet button on, which again only full mode, hardly any flow. could not believe that this was not the problem.
    And then after testing it for a good few times, the jet button refused to go on to full bubbles, I am thinking that this is some safety cut-off switch inbuilt. I thought for a while that possibly the pump smelled like it was burning just a little. I have taken out all the jets, emptied the water, blasted a hose through all of them, thinking that if 50% of the impellor is disintegrated, then bits must be stuck somewhere. Some small bits have come out. very small though. I am wondering if I need to buy a new pump, Just hope it's not the motherboard or control panel. Because the pump has not 2 speeds working, or something is definitely not right. What's your opinion. Is there something else I need to check? I am cracking up, not finding the problem, Could it be the capacitor? I am hoping a new pump will solve the issue. Appreciate your opinion thanks.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 роки тому +1

      Whats the brand (name) of the hot tub?

    • @swedishkev
      @swedishkev 3 роки тому

      @@VIPPoolsandSpas camargue Rimini , denform ,denmark

    • @swedishkev
      @swedishkev 3 роки тому

      @@VIPPoolsandSpas pump lx whirlpool

  • @macminista2003
    @macminista2003 Рік тому +1

    I have a new circulation pump which keeps making screeching sound. It’s the second time this has happened after four days of turning it on. Please can you help.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Sounds like the bearing.

    • @macminista2003
      @macminista2003 Рік тому +1

      @@VIPPoolsandSpas thank you for your prompt response. How can it be possible on two occasions for it to go so quickly? How can I replace the bearings for Laing E10 circulation pump, where can I buy parts in the UK>

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  Рік тому +1

      Its all one piece. Can't replace on a Laing. If its a grinding sound, replace the pump. If it's a "ticking" sound, check the impeller.

  • @judydai4045
    @judydai4045 3 роки тому +1

    Why my lifespa new pump only have high speed on, lower speed which when the heat on, the low speed should be on to circulate water, so that spa water can be heated up. Can you help me with this issue, thanks.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 роки тому +1

      New pump?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 роки тому +1

      You wired the cord into the new pump? Does the new pump have 2 speeds? Does the cord have a black and a red wire?

    • @judydai4045
      @judydai4045 3 роки тому

      @@VIPPoolsandSpas the new pump has two speed, and black wire for high speed and low speed is red color

    • @judydai4045
      @judydai4045 3 роки тому +1

      After installation of the pump, I adjusted the control panel on the temperature to 90 degree, and it shows me temperature jump up very quick without hearing the lower speed pump running,

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 роки тому +1

      @@judydai4045 what spa pack is in the tub? Also. Make sure the pump is wired right. Red should be high and black should be low