Sir most of time contractor font follow the calculation of devolepment length as per design he /she just subtract the calculation of cover from both side top and bottom . My Q is that suppose there roof beam of 300*450 having 25mm dia reinforcement and LD is 50*dia of steel so LD become 1250mm but our beam is 450 mm in depth and so it will cross through the roof slab What is the alternative of such problem as per IS code
Aap log is channel me hum logo ko jitna carefully sikhate hain itna detailes me hum log college me bhi nahin sikh paya. So many many many many thanks to you .
Doubt- सर हमारे घर के contractor ने सभी columns में 12mm का सरिया use किया है बस 2 column ऐसे है जिनमे 4 T10 mm का सरिया लगा है, इन दो columns के बीच में दुरी 5ft की है, अभी सारे columns का construction plinth level तक ही हुआ है, कृपया मुझे बताये क्या में foundation से आती हुयी इन दो columns की 10mm की सरिया को T12mm की सरिया से overlap कर सकता हूँ क्या?? 🙏
Development length me load steel to conceret kese transfer hota ye samjh me nai aaya.yeha concret kese work krta hai load transfer me please isko bataye
Video ko Like aur Share karne se main MOTIVATE hota hu... Jo mujhe help karti hain apke liye every day videos banane mein. Thanks
Sir Apne mera mail ka answer nehi diya....... 😐
Main sab ka main ka reply kar diya hu.. agar ap kal mail kiye ho to aj mil jayega..
Sir i think 3rd point that you have discussed between l.d & lap splices get interchange one another
You said l.d 50 d & lap 30 d or requred at the site which is max. We used but lap will be 50 D
Sir most of time contractor font follow the calculation of devolepment length as per design he /she just subtract the calculation of cover from both side top and bottom .
My Q is that suppose there roof beam of 300*450 having 25mm dia reinforcement and LD is 50*dia of steel so LD become 1250mm but our beam is 450 mm in depth and so it will cross through the roof slab
What is the alternative of such problem as per IS code
Aap log is channel me hum logo ko jitna carefully sikhate hain itna detailes me hum log college me bhi nahin sikh paya. So many many many many thanks to you .
Simply superb information ❤
Amazing video, tecnic super se super , aap zero lavel se samjhte ho ko bhi fresher samjh jayenga ,ye hota padane ka tarika"
Mukesh bhai is my best teacher 🤗
Great Sharing...
Respected sir your demo is excellent
Give further details,your demo is very clear
Awesome video sir ji ❤❤❤
Nice Explanation
Bahut achha hai
Really Good Bro. Now a days you improved a lot. Keep it up. All the best.
Very good information
Nice Video Sir
Superb
Very well and clearly explained
Keep it up
Mjjy kabii bii in dunu mn difference smjh nii aya until and unless i watch this video.... Love you sir from islamabad 🇵🇰
Sir may all ur wishes come true 💯🙏🙏🙏 ty so much for teaching, ty so much
Most welcome
Asome Sir😍❣️❣️
good explanation
Keep watching
Use full information sir 👌👌👌👌👌👌
Sir
Ld calculation per video banaye
Bhout acha hain sir
Sr i am ur big fan
Very help ful sir ji 🙏🙏
It's really help full for me ...Thank u sir🙏
Helpful sir
Keep watching
Its really help me
Superb bro
Excellent video sir. Thnx a lot
Thanks sir 🙏
Fine
Sir you are great.
ভালো লেগেছে
Super informed Sir
Well explained
Thank you 😊 😊
Most welcome 😊
Darun sir
Thanks
Good
Sir Difference between Development length and anchorage length?
video aa jayegi iski.
Anchorage length k bareme video banaye
Ok
Thank you so much sir
Thanks sir
Excellent explanation... 👌
Sir it will be grateful if you will show the chart as you tell us about lapping length concrete grade wise ..plz sir
Maine already video banaya hai ispe...
Thank u Sir it's nice video.
Please Sir make a video of long column and short column.
Pls. Make a video of construction with thumb rules.
I am first view
Beam me extra bar kese nikalte he sir ditel se bataoye
Development length is given on end columns.
Soil compaction test...is pr video kb bna rhe h sir
Sir ji mager bridge layout ke bare mein bataye
Sir development lenth and leping lenth find karne ka formula same hoga..?
Thanks sir...
tnx
Difference between Anchorage length and Development length?
Parso hi video banai hai ispe... Aap ja ke dekh sakte hai channel pe..
@@LearningCivilTechnology found it, thank you sir.
Sir Ji Agr overlapping me sariya band nhi kiya h toh Koi problem toh nhi hogi pls btaiye
Thermal Power Plant If you give some information about this...Realy it help us
Doubt- सर हमारे घर के contractor ने सभी columns में 12mm का सरिया use किया है बस 2 column ऐसे है जिनमे 4 T10 mm का सरिया लगा है, इन दो columns के बीच में दुरी 5ft की है, अभी सारे columns का construction plinth level तक ही हुआ है, कृपया मुझे बताये क्या में foundation से आती हुयी इन दो columns की 10mm की सरिया को T12mm की सरिया से overlap कर सकता हूँ क्या?? 🙏
👍👍✌
What is distance between two laps
Development length me load steel to conceret kese transfer hota ye samjh me nai aaya.yeha concret kese work krta hai load transfer me please isko bataye
Sir , IS CODE 456:2000 me aur previous Is code me kya difference hai
Pile Cap lap length??
❤
mera plote north side 23'5" & south side 25'5" and east side 38'4.5" & west side 38'5.5" ha to area sq ft & sq inche me batye .sir please.
Sir interview me ek question pucha
Tha ?
What is IS Code for BBS,and steel Reinforcement?
IS:1786 HYSD BAAR
Lap length me Ld kya h & iske value kya lete h
Aapne channel ka name change kyo kiya
Taki sabko asani se pata chal sake ye channel civil engineers k kie hain.
Lap length ka details IS 456:2000 me kis clause me hai
एक बीम मे 12mm 4Steel है, कितना Steel मे Lap दे सकते और कहां कहां देना चाहिए (Beam Lenth14mtr)
L/4 dono side se chodkar beech mai daina
🙏 🇮🇳 👍 😍
Sir app techar ban jao gi tuo Acha hay
Ban to jaunga..lekin koi college mujhe job degi kya...
English
Thanks sir
Thanks sir