    Basic Rules for Lapping length in Column - Lap length in RCC Column
    Practical Training course & Fee Detail:- www.civilguruji.com/s/store/c...
    CALL NOW:- 9111001234
    ABOUT THIS VIDEO :-
    In this video Er. Akash Bohare & Corporate Trainer of Civil Guruji (Civil Engineers Training Institute) is Explaining About Basic Rules for Lapping length in Column - Lap length in RCC Column
    When we provide lapping in a column, all the rebars should be lapped in zone-B as shown in the drawing. The top and bottom portion of the column, i.e. zone-A ( L/4 length ) should be avoided as there will be a maximum moment in this zone due to lateral forces acting on the column.
    If the length of the column is L, then the L/4 length from the top & bottom of the column is categorized as tension zone A and the center L/2 length of the column (zone B ) is considered a safe area for the lapping purpose.
    All the bars that are lapped should be staggered within zone B as shown in the above drawing. In any case, not more than 50% of rebars should be lapped in the same level. If all the column bars are lapped at the same level, it leads to failure of the column.
    The spacing of the stirrups in the lapping zone should be minimum when compared to the regular column c/c stirrup spacing.
    If the designed regular spacing for the column stirrup is 175 c/c, then the spacing of stirrups in the lapping zone maybe 150 c/c or 125 c/c as according to the column design.
    As per IS code, if the bar diameter is greater than or equal to 36mm, then you should consider welding those bars instead of lapping. If welding is not possible, then you can lap these bars with an additional spiral of 6mm bar at the splice length.
    For the rebars of diameter greater than 12mm, you can consider providing a joggle of 1 in 6. That means if the bar dia. is 20mm then the length of the joggled part of the bar can be calculated as
    J = 6 ×Diameter of rebar
    = 6 × 20mm = 120mm.
    When we tye the rebars in the lapping zone, the joggled part of the bar should be placed over the inner surface of the bottom bar (as shown in the above drawing ) to get a uniform clear cover from the concrete surface.
    If you tye the joggled portion of the rebar over the outer surface of the bottom bar, then the lapping zone invades the concrete cover area provided for the bars.

КОМЕНТАРІ • 373

  • @cadwithmohasin1755
    @cadwithmohasin1755 2 роки тому +9

    Sir you are really a experience holder. I am happy that i am your subscriber. I hope you will continue to bring such videos.

  • @jaibheem2154
    @jaibheem2154 2 роки тому +1

    Tq sir for sharing ur precious knowledge to us

  • @SonuRaj-cd1vy
    @SonuRaj-cd1vy 3 роки тому

    Impodent vedio.... shaander vedio sir🙏🏼🙏🏼 tq civil guruji

  • @sultansyed4316
    @sultansyed4316 3 роки тому +1

    Thank u sir ji for valuable information 🙏

  • @RafiAhmad-oh3gw
    @RafiAhmad-oh3gw 3 роки тому

    Sir i liked your teaching. Your videos always be a complete informatable videos

  • @ziauddin7948
    @ziauddin7948 Рік тому

    excellent column bar lapping length calculation & rules #👍👍

  • @arunverma4210
    @arunverma4210 3 роки тому

    Thanks sir you are doing great work

  • @lileshkumar5434
    @lileshkumar5434 3 роки тому +5

    Best way to learn laping.....very ease explanation.....thank you so much sir......aise hi direct site se hi video laate rhiye sir jo important hai construction me Hum engineer k liye....aur sath hi jo pdhai kr rhe hai usko bhi visualize tarike se smjhne ko milta hai.....♥️♥️

    • @Civil_Guruji
      @Civil_Guruji  3 роки тому

      Lilesh ji thank you... Bilkul apke learning ko hamesha badhane k leye Civil Guruji apke according videos laate rahega.... Keep learning keep sharing

  • @Rajeshkumar-mx6uw
    @Rajeshkumar-mx6uw 3 роки тому +2

    Thank u so much for giving your valuable time i think this video is valuable for everyone..

    • @c42c1
      @c42c1 3 роки тому

      I am thankful for knowledgeable video. I have one query , I am constructing house there is column shifted in retaining wall while basement shuttering , now ground floor column is out now rebar should be from basement or Frist floor level. Which is correct one.

  • @shaileshjadhav8302
    @shaileshjadhav8302 2 роки тому

    Thanks sir....khup mast details sanghitale lapping zone

  • @kumaramarendra9636
    @kumaramarendra9636 3 роки тому +9

    Many concepts clearl just in one vedeo,thanks sir.

    • @Civil_Guruji
      @Civil_Guruji  3 роки тому +2

      Amarendra i feels good to hear that keep learning keep sharing

  • @shivprasadtiwari1770
    @shivprasadtiwari1770 2 роки тому +2

    Sir,
    Kindly make a video of tolerance limit of plumb of various components of R.C.C.members with reference to I.S. Code.

  • @buildingworksolution.7639
    @buildingworksolution.7639 2 роки тому

    Ap ne Bahut achhe se samjaya

  • @ujjalbistu8754
    @ujjalbistu8754 3 роки тому +3

    Love u sir for ur concept ...all doubt clear...

    • @Civil_Guruji
      @Civil_Guruji  3 роки тому

      Thank you Ujjal.. Bahut acha feel hota hai ki aap sab apni learning ko le kar aahe badhna chahte hai... Ise tarah se aage badhiye Civil Guruji hamesha apke support k leye hai...

  • @fazalamin4034
    @fazalamin4034 2 роки тому

    thanks for each lecture

  • @mayurgoswami7367
    @mayurgoswami7367 Рік тому

    Good detailed video.Thanks

  • @sultansyed4316
    @sultansyed4316 3 роки тому +5

    Column is the most important part of structure

  • @sanjayborge2240
    @sanjayborge2240 3 роки тому

    Very informative and useful post subject to lap, please upload next video so that purpose of this video will be best, don't delay.regards.

  • @khaniqtidar8627
    @khaniqtidar8627 2 роки тому

    Masha allah. Great.

  • @akramahasan3150
    @akramahasan3150 2 роки тому +8

    But U r provided lap on L/4 junction. As per rule lap are provide after L/4.
    Means =3200 clear distance then we provide lap above 800mm means 800+lap length

    • @Fun_Tech_GK
      @Fun_Tech_GK 2 роки тому +3

      you are right.....
      but in this video it shows lapping in non lap zone
      it's wrong.....

  • @hikikomorihachiman7491
    @hikikomorihachiman7491 Рік тому

    Could you upload a video how they make the jackle aligned?
    I keep seeing the crank/jackle getting out of alignment each time the stirrups/ties is fitted on the column.

  • @vikashkumaryadav3228
    @vikashkumaryadav3228 3 роки тому +5

    Sir please use imperial units as it is more convenient for engineers as well as clients.

  • @baldebkishan3233
    @baldebkishan3233 3 роки тому

    Pranaam Civil Guruji. Please make video on Shuttering of Stairs

  • @rachananegi6078
    @rachananegi6078 2 роки тому

    informative ..thank you

  • @SachinPatil-jo8wk
    @SachinPatil-jo8wk 3 роки тому +1

    Sir if the beam is setting eccentric except the center of the column then what should be the size of the column at that time.

  • @dietali333
    @dietali333 2 роки тому +1

    If the only 40cm length available above the ground floor slab column.
    Can you please advice me about the lap lengths is ok for the first floor to second columns.

  • @zaheerimtaz
    @zaheerimtaz 2 роки тому

    Aapka vedio bht hi ACHA hai..
    Great knowledge ke saat

  • @sesibabugantyada4479
    @sesibabugantyada4479 3 роки тому

    Good analysis👍

  • @mohdehtesham1429
    @mohdehtesham1429 3 роки тому

    Excellent concept

  • @PMPlansDesign
    @PMPlansDesign 3 роки тому +3

    The top most important learning platform is here for civil engg.I can guess that how much your team is dedicate,passionate to provide the knowledge to others that's why the channel has not been monetized till now.U r Great Sir. 🙏🙏

    • @kaakib8841
      @kaakib8841 2 роки тому +1

      O course bech k paisa chhapte hain... Sab business hai

  • @pranjal.jha.
    @pranjal.jha. 3 роки тому

    Well done Akash bhai ✅

  • @ommishra7610
    @ommishra7610 2 роки тому

    Sir this video very helpful

  • @dilse7192
    @dilse7192 2 роки тому

    Thanks sirji super video

  • @tabraizhussain594
    @tabraizhussain594 2 роки тому

    Very good lecture

  • @nikeshshrestha5409
    @nikeshshrestha5409 3 роки тому +76

    This one is mistake bro...lap should be at the mid section of the column. I mean rod must be cut at h/4 + lap length from the plinth beam. However, in this case, lap is not at the mid section.

    • @anuragkhati4547
      @anuragkhati4547 2 роки тому +6

      Wahi to 800 mein hi lap kar dala isne ,

    • @ahmedzohair9905
      @ahmedzohair9905 2 роки тому +5

      Lap should be in zone B. Either in mid or up and down but shall not enter in zoneA, that is L/4 from top and bottom

    • @Adarsh_Yadav1
      @Adarsh_Yadav1 Рік тому +4

      yes bro he made mistakes

    • @shadikansari7505
      @shadikansari7505 Рік тому +4

      Sahi bola bro, ye to khud hi galat sikha raha hai logo ko

    • @musarratrazakhan4389
      @musarratrazakhan4389 Рік тому +1

      True👍

  • @shubhamshegokar
    @shubhamshegokar 3 роки тому +10

    Qty of Rate analysis in excel per video banaiye sir

  • @prabhupadasahoo7483
    @prabhupadasahoo7483 3 роки тому

    Sir ,Please make a video quantity of reinforcement of Column

  • @vinayshastri8274
    @vinayshastri8274 2 роки тому +9

    I am a diploma civil engineer from 1968 batch , and wish to suggest so many my experiences to society of engineers.

    • @sahilpatel7308
      @sahilpatel7308 2 роки тому +2

      Can you please share your experiences.? It would be helpful to us

    • @rickmorthy4576
      @rickmorthy4576 Рік тому

      Please help share us some of your knowledge

  • @CivilConstructionWorld
    @CivilConstructionWorld 3 роки тому +1

    GOOD VIDEO BROTHER KEEP DOING

  • @bhartpur8368
    @bhartpur8368 2 роки тому

    Thank u so much.......

  • @Asifsultanmehar
    @Asifsultanmehar 2 роки тому

    thanks ❤
    for nice sharing

  • @samirbala9007
    @samirbala9007 2 роки тому +1

    Sir, favourable and Unfavorable Bond condition ki ak video upload karia sir, it will be very helpful for us... (IRC 112-2011) Where Lape Length is varying.. according to Bond condition...

  • @jayantajithazarika2619
    @jayantajithazarika2619 2 роки тому +1

    Thank you very much for your nice and fàntastic video .

    • @Civil_Guruji
      @Civil_Guruji  2 роки тому

      Jayanta thank you for your words... Keep learning

  • @rameswarmunda4466
    @rameswarmunda4466 3 роки тому

    Sir very good helpfull

  • @abhishekshah3598
    @abhishekshah3598 Рік тому

    Can we cast 12m bar for column without cutting , for clear height 4m (2Floor) ?

  • @garammasala4661
    @garammasala4661 3 роки тому

    Shukriya sir ji aap ek footing se lekar slab tak ka single video banadijye with full details

  • @gajananeh8469
    @gajananeh8469 3 роки тому

    Thank you sir

  • @atrandom1438
    @atrandom1438 3 роки тому

    Yes, i want more video related to site visit.

  • @ahsanulhaq6132
    @ahsanulhaq6132 Рік тому

    Great information

  • @erkundanyadav
    @erkundanyadav 3 роки тому

    Come with some beam Reinforcement details also sir from site.

  • @shatrughanprasadbharti1162
    @shatrughanprasadbharti1162 2 роки тому

    We have to follow lower dia for lap, is it mention in code ?

  • @saurabhmahar7852
    @saurabhmahar7852 Рік тому +1

    Thankyou so much sir

  • @remixes1916
    @remixes1916 2 роки тому

    Bottom portion se kaise lap ho skta hai...ek to galat bhi pdha rhe,upar se itna confidence..bhagwan bchaye civil engineers ko civil guruji se

  • @officialvaidehinayak3186
    @officialvaidehinayak3186 3 роки тому

    Well done 👍

  • @adityajoundal8500
    @adityajoundal8500 2 роки тому

    Sir aisehi information dijeye🙏

  • @aryaman4068
    @aryaman4068 3 роки тому

    Wow awesome video

  • @anujgupta.youtubestar6434
    @anujgupta.youtubestar6434 3 роки тому

    Nice.. Tecnical view

  • @Ergamer-dm2fr
    @Ergamer-dm2fr 3 роки тому

    please make a video on cheak shear force in beam so we can evaluate our beam is safe or not, without using is code

  • @MARUTII
    @MARUTII 3 роки тому +1

    excellent video sir
    aap ke jaise teachers agar collages main ho to desh ka cehra badal jayega.

    • @Civil_Guruji
      @Civil_Guruji  3 роки тому +1

      Maruti ji thank you for such a lovely comment... Hume bhi bht inspire karta hai apka support.. Keep learning keep sharing

  • @ajaykumarchakravarty3053
    @ajaykumarchakravarty3053 2 роки тому

    Excellent.

  • @shahmikonyak5942
    @shahmikonyak5942 2 роки тому

    Good explaining...👍👍👍👍

  • @d.d.dansena8606
    @d.d.dansena8606 Рік тому

    Welding will be use for lap joint,??

  • @rupammandal3910
    @rupammandal3910 3 роки тому

    Sir, plz make a video on beam column junction as per IS 13920....

  • @akashpatil5155
    @akashpatil5155 Рік тому

    What will be the length or ratio required for Lap of joggle / what will be the joggle length ?

  • @SachinPatil-jo8wk
    @SachinPatil-jo8wk 3 роки тому

    Nice lecture sir

  • @harshkumar2010
    @harshkumar2010 3 роки тому

    thanks

  • @fahimakhtar1000
    @fahimakhtar1000 3 роки тому

    Very nice 👍

  • @hellosir8844
    @hellosir8844 2 роки тому

    Sir make video on retaining wall steel design

  • @dulhapur
    @dulhapur 2 роки тому +4

    Clear Height between plinth beam top and roof beam bottom-11 feets
    Zone-A-11/4=33 inches
    Zone-B-11*12-66=132 -66=66 inches
    There are 6 bars 16mm@4,12mm@2
    At zone B top- 2 no of lappings
    At zone B middle(30 inch below top lapping points)-3 no of lapping
    At Zone B bottom (30 inch below middle lap point)-1 lapping
    Whether the above arrangement is allowble?
    Whether lintel tie beam can be provided any zone?
    What if lintel tie beam falls on zone-A top area?

  • @shrinivasuttarwar372
    @shrinivasuttarwar372 2 роки тому

    Sir mere 1st floor pe contrapctet ne galti ki, sirt Or sirt 1.5 feet hi steel ki length chhodi.... He to kya kar sakte he...

  • @user-ld6oh7fz6k
    @user-ld6oh7fz6k Місяць тому +1

    Sir gajab kya explain kiya
    Meri nazre nahi hati 11 minutes tak

    • @Civil_Guruji
      @Civil_Guruji  Місяць тому

      Thanks for the love, @user-ld6oh7fz6k! 🌟 Khushi hai ki aapko video pasand aaya.

  • @jhalakgiri8612
    @jhalakgiri8612 2 роки тому

    Namaste 🙏 Nepal 🇳🇵

  • @AnaadiGk-pf3cn
    @AnaadiGk-pf3cn Рік тому +2

    धन्यवाद सर

  • @rahulmaurya1689
    @rahulmaurya1689 2 роки тому

    Pls make video on upvc pipes

  • @SabirAli-ob6ou
    @SabirAli-ob6ou Рік тому

    Think.you.sir

  • @atanusabyasachirout6479
    @atanusabyasachirout6479 2 роки тому

    Kindly make video about highway work sir

  • @arkhan1083
    @arkhan1083 3 роки тому

    sir total station se column positioning ka video banaye plz..

  • @jugeshwarrajak9295
    @jugeshwarrajak9295 Рік тому

    thanks sir

  • @mohdasgarali8704
    @mohdasgarali8704 2 роки тому

    Sir pls make a video aboy Types of steel and which is best for consideration?.

  • @erkundanyadav
    @erkundanyadav 3 роки тому

    Nice information

  • @pk.pavankumar7320
    @pk.pavankumar7320 3 роки тому

    circular column k cutting length pr video banaye sir.

  • @tiwarianant92
    @tiwarianant92 Рік тому

    Thanks for the video sir 9:49

  • @dipakkarande9672
    @dipakkarande9672 3 роки тому

    Good information

  • @shambhoodayal9230
    @shambhoodayal9230 Рік тому

    Kya ham column and beams ki steel bar ko specially case me welding kara sakte hain ki nhi in the place of overlaps

  • @mrstark9625
    @mrstark9625 11 місяців тому +1

    Thanks for sharing❤

    • @Civil_Guruji
      @Civil_Guruji  11 місяців тому

      Thank you for your comment!
      We appreciate your support. We strive to provide the best Knowledge for civil engineers,

  • @abhishekfaridvar3321
    @abhishekfaridvar3321 2 роки тому

    Thanku sir

  • @rohitray7068
    @rohitray7068 3 роки тому

    Sir, iss mai toh lap junction zone A nd B k junction mai hi aagaya par actual mai toh lapping zone B k middle mai hona chahiye na, matlab ki L/4 xod k ,zone B mai lap karna chaiyne ,pare iss video mai 4 rod toh exact L/4(800mm) mai hi hai?

  • @shamrezbashir9424
    @shamrezbashir9424 Рік тому +1

    Very informative video bro....kindly can you share your knowledge regarding check list from foundation till finishing level of double storey house and multi storey apartments....

  • @irfangul4345
    @irfangul4345 Рік тому +1

    ZABARDAST G ♥♥♥♥♥♥♥♥♥

    • @Civil_Guruji
      @Civil_Guruji  Рік тому

      Thank you
      Irfan Gul
      Hame bohat khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
      KEEP LEARING, KEEP SHARING.

  • @pradeepyadav232
    @pradeepyadav232 Рік тому

    All stirrup ke baare me video banaye sr

  • @zabeeullahazimi2437
    @zabeeullahazimi2437 3 роки тому

    Sir make video for beam lapping

  • @pateljingeshkumar3926
    @pateljingeshkumar3926 3 роки тому

    Clear Engineer 😀👍

  • @polashhasan9336
    @polashhasan9336 Рік тому +1

    Want to see more video ‍sir......

    • @Civil_Guruji
      @Civil_Guruji  Рік тому

      Watch this Video ua-cam.com/video/B0Qwlb-4xc4/v-deo.html
      Hope this Video Will help you.

  • @jahanhussain1822
    @jahanhussain1822 2 роки тому

    Design of footing ka videos banaye

  • @Himanshu_official10
    @Himanshu_official10 Рік тому +1

    Thanks sir

    • @Civil_Guruji
      @Civil_Guruji  Рік тому

      Welcome
      acting lover himansh10
      Hame bohat khusi hai ki aapko hamari mehnat pasand aai , Civilguruji isi tarah civil engineers ko aage badane ke liye mehnat karte rahega aur aap bhi knowledge dusro ko share karte rahe.
      KEEP LEARING, KEEP SHARING.

  • @AnkitPrajapati-lw8kd
    @AnkitPrajapati-lw8kd Рік тому

    Aapne jo bataya ye ek column ka lap kaha dena hai ye bat hai par koi residential and commercial building me ek floor pe 30 se 40 columns hai to sab columns me kya karna hai??

  • @pratikbaikar18
    @pratikbaikar18 3 роки тому

    Column me stirrups ki spacing kaise hoti hain?

  • @sureshkamble7665
    @sureshkamble7665 4 місяці тому +1

    Vrry good information

    • @Civil_Guruji
      @Civil_Guruji  3 місяці тому

      Thank you for appreciating our content! We're glad you found the information helpful. Stay tuned for more valuable updates.

  • @sayanbanerjee8727
    @sayanbanerjee8727 2 роки тому

    Sir plinth beam ke jo stirrup bind karte hay woh l/4 , l/5 ,l/6 ke rules wise bind karte hey, woh wali vedio bana dijiye sir

  • @barmudatv9253
    @barmudatv9253 Рік тому

    Sir chair bar ki cutting length bar nikalny wali vdio ka link share kgea please