How to Calculate Development Length ,Top Extra ,Bottom Extra ,Stirrup Spacing & Lapping Length

Поділитися
Вставка
  • Опубліковано 10 лют 2021
  • 15 Mistake in House construction
    • 15 Biggest Mistakes du...
    15 Technical Term for civil Engineers
    • 15 Technical Every civ...
    Official Website Civil Site Visit
    civilsitevisit.com
    Daily New Job Links
    civilsitevisit.com/recruitment/
    WHATSAPP GROUP
    chat.whatsapp.com/BVZb2995QXA...
    chat.whatsapp.com/K83YQHVXxkd...
    chat.whatsapp.com/BPoi8iLL9fZ...
    ( TELEGRAM GROUP FOR CIVIL ENGINEERS )
    t.me/joinchat/i84Oy3K0wqgzMjU1
    t.me/joinchat/zwE9MYXIdgY5OWY1
    ( TELEGRAM GROUP FOR JOB UPDTAE )
    t.me/joinchat/AzzpD2BS3qhmZjZl
    ( OUR OTHER UA-cam CHANNEL )
    1. For Job Update
    / @civilsitevisitjobsupd...
    2. For Business Idea
    / @businesskaadda12
    3.Civil Engineer Sharma Ji ( Basic of civil Engineering )
    / @civilsitengineer
    4.Pareeksha ( Job & Exam Preparation )
    / @civilengineerintervie...
    10 Most watched Video of ( CIVIL SITE VISIT )
    1. Tile or marble Flooring
    • मार्बल लगाये या टाइल |...
    2.How to decrease construction cost of House
    • घर बनाते समय इन 5 बातो...
    3.Construction Cost of 1000 Sqft House
    • Construction cost of 1...
    4.Parapet Wall Cheap & Best Design
    • Parapet wall two Best ...
    5.Wall Dampness Treatment
    • Wall Dampness Treatmen...
    6.Marble or Tile Flooring
    • Marble or Tile ? which...
    7.Cracks in wall repair
    • घर की दीवारों में क्रे...
    8.Mistake in House Construction
    • घर बनाते समय इन 8 बातो...
    9.1000 sqft House Material Quantity
    • 1000 sqft का घर बनाने ...
    10.ACC Block Vs Red Brick
    • 1000 sqft का घर बनाने ...
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - rs140565@gmail.com
    ✔Twitter: VisitCivil?s=09
    ✔Facebook Page: / 100041543491213
    ✔ LinkedIn: / rahul-sharma-66324a215
    ✔Instagram: / civil_site_visit
    ✔Tumblr: / civilsitevisit
    For Business Enquiry
    7006672812 (Note :- Only WhatsApp )
    Disclaimer - This video is for educational purpose only. Copyright
    Disclaimer Under Section 107 of the Copyright Act 1976, allowance is
    made for "fair use" for purposes such as criticism, comment, news
    reporting, teaching, scholarship, and research. Fair use is a use
    permitted by copyright statute that might otherwise be infringing.
    Non-profit, educational or personal use tips the balance in favor of
    fair use .
    #civilengineeringbasic #Practicaltraining #siteengineerTips

КОМЕНТАРІ • 144

  • @SAURABHPISE1
    @SAURABHPISE1 3 роки тому +1

    Good sir this is important for life . Thank you sir your help sir better

  • @ChhotanKuamar-fe8tb
    @ChhotanKuamar-fe8tb 2 місяці тому

    Aapka Har video me 100 me se 9o present swal smjh jata hu Thank you sir civil guru ki jay 🙏 namaste

  • @pihuandpranshu0024
    @pihuandpranshu0024 Рік тому

    Thanks you for provide very clear concept

  • @prafulkindo5445
    @prafulkindo5445 3 роки тому +1

    Thanks for making me civil engineer.

  • @prafulkindo5445
    @prafulkindo5445 3 роки тому

    Very very very good knowledge.

  • @arunmohan6196
    @arunmohan6196 3 роки тому

    Very nicely explained

  • @aamirmalik7096
    @aamirmalik7096 3 роки тому +1

    Waoo sir good job keep it up and thankyou 🥰🥰

  • @vikrantparihar5962
    @vikrantparihar5962 Рік тому +1

    Will cover come in lap length- In simply support beam or in continuins beam in BBS calculation ?

  • @wonderingcivil8808
    @wonderingcivil8808 Рік тому

    Thanks
    From Australia

  • @tanveerbhat8267
    @tanveerbhat8267 Рік тому

    sir mein bhout confuse tha top extra bar nikalny k liye thanks a lot sir

  • @Deepakkumar-vr2ke
    @Deepakkumar-vr2ke 4 місяці тому

    Sir ji aap great ho.

  • @arifullah5048
    @arifullah5048 3 роки тому

    Thanku sooooo much sir,for your coapration

  • @phyohtetkoko929
    @phyohtetkoko929 Рік тому

    Thanks for teaching sir

  • @GhaziAbbas313
    @GhaziAbbas313 Рік тому

    Thank n Sir me apse bhtttt kuch seekh rah hu

  • @SumanDas-ey8ro
    @SumanDas-ey8ro 3 роки тому

    Sir... Thank you... 👌👌🙏🙏

  • @civilengineerdharam320
    @civilengineerdharam320 3 роки тому

    Please make a video footing and foundation work.. Thx you

  • @ch.427
    @ch.427 2 роки тому

    Great video

  • @shibankumardutta4971
    @shibankumardutta4971 3 місяці тому +1

    Very good sir

  • @dhirugusain5834
    @dhirugusain5834 3 роки тому

    Sir, drawing or design krne k baad site pe execution ki vedio b daalna..🙏

  • @b.m.sudhakar6595
    @b.m.sudhakar6595 6 місяців тому +1

    Thanku Sir❤❤❤

  • @SahilSharma-ly7ql
    @SahilSharma-ly7ql 3 роки тому +4

    In which case bottom extra is more than top extra other than cantilever beam ?? Plz explain and also what about secondary beam resting on primary beam what about its development length

  • @hemantkharat4994
    @hemantkharat4994 2 роки тому

    thanks....sir ji

  • @bhagirathigope1809
    @bhagirathigope1809 10 місяців тому

    Thank you sir🙏🙏🙏

  • @energy3698
    @energy3698 3 місяці тому

    Thanks

  • @DJRJLPRODUCTION
    @DJRJLPRODUCTION Рік тому

    Love you Sir.......

  • @lionbln2688
    @lionbln2688 3 роки тому

    Do over head tanks design also steel details

  • @252ranjeetrajendrashinde5
    @252ranjeetrajendrashinde5 3 роки тому

    Make videos pile to rectangular column conversion

  • @randheerverma5174
    @randheerverma5174 Рік тому

    Can you say me which is code are you use sir bcz this all formula not fit in our Structure design.

  • @arjunsinhgohil2790
    @arjunsinhgohil2790 3 роки тому

    Sir kya ghar ke liye pile foundation thik hai ya footing kar ke column karte hai woh 🙏🙏🙏

  • @RaviPatel-nt6gg
    @RaviPatel-nt6gg 3 роки тому

    Structure se related video please sir ji

  • @abishekbishwakarma4062
    @abishekbishwakarma4062 3 роки тому

    very nice

  • @saidviproductions8123
    @saidviproductions8123 Рік тому

    great sir

  • @Muhmd123.
    @Muhmd123. Місяць тому

    According to which code?

  • @ayushraghav6675
    @ayushraghav6675 10 місяців тому

    Less also bend from deployment lenght

  • @mayu792
    @mayu792 Рік тому

    Sir thanks for this vidio...but..digram me dusre side me dekho 0=15L likha he..baki pura samj aaya he...or ak vidio banayiye same pr dusra site+digram+blank papers pe samjayiye..clrly...
    Utube me aapki taraha kisine nahi samjaya he..but one more try...u get outstanding vidio...
    Or ha c/c se samjayiye colom konsa bhi size ka raha to problem nhi hoga

  • @er.sunnykhangwal5570
    @er.sunnykhangwal5570 3 роки тому

    Thanks for your great support sir.its really more helpfull for freshers .👍👍👍

  • @izaanahmad7494
    @izaanahmad7494 3 роки тому

    Sir apne is series me ek jagah bataya hai
    *stirrups m spacing +, - 15mm & cover block me +, - 10mm ka tolerance chalta hai IS CODE me dia hai.
    Sir yh IS CODE m kaha dia hai.
    Please mention kriye.

  • @imranali8706
    @imranali8706 2 роки тому

    Sir colum ka bbs bataye plz

  • @AsgharAli-cw6vb
    @AsgharAli-cw6vb 3 роки тому

    Good

  • @Manjunath_pai
    @Manjunath_pai 3 роки тому +2

    Sir in L/4 we take L= Clear span you told in video to take effective span .Which one is correct

    • @MAnas-el6cd
      @MAnas-el6cd Рік тому

      See in drawing detail L is effective span and not clear span. Spa

  • @dhirajawade5526
    @dhirajawade5526 3 роки тому

    Sir beam mai strips jo hai unka hook jo aata hai wo kis taraf ana chahiy uper ki taraf ya niche kai tarf?

  • @omprakashmandal543
    @omprakashmandal543 3 роки тому

    Column ka bbs video ek upload karo sir ji

  • @roopeshsolanki5786
    @roopeshsolanki5786 2 роки тому

    phi*fe/4tbd is this the second formula?

  • @Rock-xw1ty
    @Rock-xw1ty 3 роки тому

    Achi video

  • @iasmotivation8632
    @iasmotivation8632 3 роки тому

    Sir beam Ka schedule drawing kya aap mujhe de skate hai

  • @pappanthelegend2662
    @pappanthelegend2662 3 роки тому +1

    What if my beam depth is 400mm..How to give 510 as ld

  • @bhaviktank9964
    @bhaviktank9964 3 роки тому +2

    Bbs calculated karte hai staircase beam slab ya video lekar aaoo

  • @munirrayma339
    @munirrayma339 3 роки тому +1

    Sir 510 ka pura dege to cover kaise milega beam me..

  • @user-tu3lq2xl2g
    @user-tu3lq2xl2g 4 місяці тому

    Hello sir
    Kya aap aese aur drawings de sakte hai mujhe practise ke liye

  • @hemanttumreki8024
    @hemanttumreki8024 2 роки тому

    L/7 ke bare me bataiye

  • @dhruvratanpara1279
    @dhruvratanpara1279 3 роки тому +1

    tq sir🙏

  • @armyofficermanishsharma5039
    @armyofficermanishsharma5039 3 роки тому +1

    Good evening sir

  • @samdecent4362
    @samdecent4362 3 роки тому

    Ld=(0.87fy)xdia/(4 Tbd)
    Development length ka formula ye haina syllabus me to ye bataya tha?
    Please clear my doubt

  • @vipinchandra8955
    @vipinchandra8955 3 роки тому

    Sir apne column ka reinf ke bare mai Nhi btaya...column reinf 40 mm pe phir beam reinf 25 mm ke cover pe ayega

  • @arifurrahman1150
    @arifurrahman1150 3 роки тому

    Building slab casting ke liye knsa cement use kare OPC or PPC

    • @Melodymix10
      @Melodymix10 4 місяці тому

      Use ppc it has more strength than opc.....

  • @riyazshah4915
    @riyazshah4915 3 роки тому

    Sir -510 hoo to beam ka size kitna

  • @MAnas-el6cd
    @MAnas-el6cd Рік тому

    if a beam B1 is connecting to a Col from one side and another beam B2 is connecting from opposite side of col. And both beams details is different B1 has 3 Top continues bars and B2 has 4 Top continous bars how will we provide development length and will B2 continues bars extend into B1 or not plzzzzzzz someone .....

  • @Faisu_shorts1008
    @Faisu_shorts1008 9 місяців тому

    Ap bhtt accha smjhate ho bhai

  • @mohitsingh1515
    @mohitsingh1515 3 роки тому

    Maximum length of beam and column

  • @abishekbishwakarma4062
    @abishekbishwakarma4062 3 роки тому

    keep it

  • @mohittiwari2989
    @mohittiwari2989 Рік тому

    What is spacing length?

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 Рік тому

    @10:08
    Sir you are wrong.
    We shouldn't provide lap upto 2D for bottom rebar.

  • @shibankumardutta4971
    @shibankumardutta4971 9 місяців тому

    Sir 20 minut wala video dikhie

  • @bhupendrathakur1141
    @bhupendrathakur1141 Рік тому

    Sir video quality badayiye

  • @ashishkamble2242
    @ashishkamble2242 Рік тому

    sir beam ki depth 500 hai to 510 kaise aaya please samjhao

  • @rezaurrahman2713
    @rezaurrahman2713 Рік тому

    Sir 20 minutes wala video chaheye hum ko..

  • @mdfaizakram21db49
    @mdfaizakram21db49 7 місяців тому

    L ka value 500 kis ke according le liye

  • @amdnishar7865
    @amdnishar7865 2 роки тому +1

    Ye 10 db samajh me nhi aya sir pliz kaha se aya 10db

  • @housevaastu
    @housevaastu 3 роки тому +1

    Sir L d ki value comp aur tension member k liye 1 formula h us s development length find k जाती है

    • @civilsitevisit
      @civilsitevisit  3 роки тому +1

      uspe b video hai dekho channel meh

    • @housevaastu
      @housevaastu 3 роки тому

      @@civilsitevisit usme 49D h and grade M25 h.

    • @araynyadav7696
      @araynyadav7696 3 роки тому

      @@civilsitevisit sir job hai to hum logo Ko bulaeye

  • @rahulramola934
    @rahulramola934 Рік тому

    3:55 top extra bars

  • @prashantananda1221
    @prashantananda1221 Рік тому +1

    Sir Aapka beam ka depth 500 ka toh fir 510 ka steel kaise provide karoge ......kya sir kuch b bak rehe ho .........LD me hi sab Ho jayega sir , 10d ka koi jarurat nehi hai .

  • @RaviPatel-nt6gg
    @RaviPatel-nt6gg 3 роки тому

    Sir ji good evening video clean please🙏

  • @theakashthings8637
    @theakashthings8637 3 роки тому +1

    Top extra ka bhi nikalo

  • @masoomraza8365
    @masoomraza8365 3 роки тому

    Bottom extra ko L/7 kaise lete hai kanhi kanhi drawing pe diya rahta hai

  • @MohdAnas-jz2ue
    @MohdAnas-jz2ue 3 роки тому

    Why did u take only 1 side cover? Its 50 cover so u have to take bothe side

  • @armyboyshailendra289
    @armyboyshailendra289 2 місяці тому

    0.10*l kaha se aata hai dor

  • @mdrahmatullah8527
    @mdrahmatullah8527 3 роки тому

    ❤️❤️❤️

  • @ajaydhamtan2926
    @ajaydhamtan2926 3 роки тому

    ❤️

  • @akhilkachhiya197
    @akhilkachhiya197 3 роки тому

    500 mm depth he column ki to 510 mm kese ho sakta he...

  • @moreconstruction4575
    @moreconstruction4575 3 роки тому

    😍😍

  • @AmitRawtiya
    @AmitRawtiya 3 роки тому

    But sir IS 13920-2003 clause 6.2.6 said we can't provide lap in confining zone.
    Due to seismic zone k movement के karan column k inner face se hame 2D (D= effective depth of beam) हट्टाना पड़ेगा.
    And also IS code said we can't provide lap जाहा Positive Bending Movement Over 50%..???
    But apne video me btaya lap hmm center se 0.15L pr provide krenge...but IS code toh isake liye mnaaa krtaa h....

    • @farazshaikh2109
      @farazshaikh2109 2 роки тому

      Yes you r correct , we can't provide lap @ 0.15L from support, IS 13920 clearly mentioned that

    • @chatpatgamingyt2707
      @chatpatgamingyt2707 Рік тому

      @10:08
      Sir we shouldn't provide lapping upto 2D for bottom rebar.
      Please you read carefully codebook

  • @sulendrnayak496
    @sulendrnayak496 6 місяців тому

    Very naice ❤🫶👌🌹✍️🙏

  • @santanukumarlenka9919
    @santanukumarlenka9919 8 місяців тому

    0.15L?

  • @vishalsharma5415
    @vishalsharma5415 3 роки тому +3

    Why we dnt apply direct 60 db that equal to 50d +10 d

  • @shivbhagwan8166
    @shivbhagwan8166 3 роки тому

    I know Steel working

  • @miraamir1104
    @miraamir1104 Рік тому +1

    When depth of beam is 500mm how is it possible to provide 510 mm devlopment length as you calculated

    • @favadkhan5805
      @favadkhan5805 Рік тому

      deveelepment length galat nikali

    • @xahidmushtaq4062
      @xahidmushtaq4062 Рік тому

      The development length at column beam junction of bottom bars has no issue because they can go through the height of column

    • @miraamir1104
      @miraamir1104 Рік тому

      @@xahidmushtaq4062 what about strip footing with eccentric wall with only 150mm spacing from the exterior face of wall to the exterior face of strip

  • @sajidshaikh1502
    @sajidshaikh1502 3 роки тому +15

    But our beam depth is 500 how we can provide 510🤔

    • @tafzeelqureshi5444
      @tafzeelqureshi5444 3 роки тому +1

      That extra length will go in column.

    • @sajidshaikh1502
      @sajidshaikh1502 3 роки тому +4

      @@tafzeelqureshi5444 but column fill till the bottom of beam... So we have only 500mm depth if we assume 40 mm cover from top then 40 mm also subtract from 500mm🤔

    • @viveknt2467
      @viveknt2467 3 роки тому

      @@sajidshaikh1502 exactly

    • @sanjitjadhav7273
      @sanjitjadhav7273 3 роки тому +1

      First we have all drawing details and development length is also mentioned. So that column is fill up to that point where development length is apply.

    • @prajjupoojary2352
      @prajjupoojary2352 Рік тому +3

      @@sajidshaikh1502 this question answerable by only experienced civil engineer. This man didn't have any practical knowledge. Only book knowledge

  • @rezaurrahman2713
    @rezaurrahman2713 Рік тому

    Development length wala

  • @mdmazharali991
    @mdmazharali991 Рік тому

    0:00

  • @sndpn4u
    @sndpn4u Рік тому +1

    300/500 beam mein development length ka baki 510 mm AAP kaha dalenge.. calculation galat hai

  • @bonanza2247
    @bonanza2247 Рік тому

    Why depth of beam is always larger than width ?

    • @MAnas-el6cd
      @MAnas-el6cd Рік тому

      Not always
      I have seen a beam of 30 inches width and 24 inches depth at site.

  • @alok1144
    @alok1144 3 роки тому +1

    450 beam me agar 16 mm ka daya aaya toh 510 kaise ayega

    • @civilsitevisit
      @civilsitevisit  3 роки тому

      minus kar lo jo b ayega
      calculation meh glti ho sakti hai check karo

  • @wondergyan6171
    @wondergyan6171 3 роки тому

    Sir please provide me this drawing in pdf form

  • @e.sankari1394
    @e.sankari1394 3 роки тому

    Can you please say in English

  • @rajasthanibhauu2299
    @rajasthanibhauu2299 2 роки тому

    Appki beam ki depth hi 500 h, to 510 kese denge development length

    • @sumantamaitra4778
      @sumantamaitra4778 2 роки тому

      Total 870mm se jyada idhar development length nahi diya ja sakta

  • @itstruelife1514
    @itstruelife1514 3 роки тому

    Ld+10db many sir mana jitna bhi kam kiya ha usma follow hi nhi kiya ha

    • @amdnishar7865
      @amdnishar7865 2 роки тому

      Ye 10db kaise aya bhai mukhe to nhi aya samajh me bata do bhai

  • @akhileshpandey1025
    @akhileshpandey1025 Рік тому

    Devlopment length calculation formula is wrong

  • @keshariciviltech6719
    @keshariciviltech6719 Рік тому

    Abe bhai kyn glt bta rha h clear span inner to inner column hota h aur tm out to out bta rhe ho

  • @nooraincivilengineer
    @nooraincivilengineer Рік тому

    Bhut speed bataye hain

  • @jitendra5301
    @jitendra5301 Рік тому

    Yee🥰🥰