HURRY THE OFFICE AC IS NOT COOLING AT ALL

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 119

  • @2xKTfc
    @2xKTfc 24 дні тому +37

    "They could be calliing someone else" is the addendum to "it's a lot easier to get budget for an 'emergency' than for maintenance". Sometimes, maybe, you're lucky and telling them "more maintenance expenditure will save you more in overtime fees" actually goes through to the right person.

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому +8

      Maybe one day it will hit the right set of ears

  • @andyguest6543
    @andyguest6543 24 дні тому +12

    Coil cleaning videos might be boring for you but I find them so satisfying and enjoyable to watch.

  • @toddgailboord6213
    @toddgailboord6213 24 дні тому +8

    Hi and Thank You in your after video notes. Reminding us to have a good attitude toward our customers (even when they do not make sense). They support us by calling us. We need to support them and listen to them.
    Sincerely
    Todd

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      Exactly right, thanks for watching

  • @aeternusdoleo4531
    @aeternusdoleo4531 24 дні тому +15

    "Thermostat was blank" - "You need to cycle power to reset the HP Lockout"
    I'd ask the manager to verify if someone didn't decide to turn off/on the breaker for that thing by applying the trusty "have you tried turning it off and on again" method of troubleshooting. I would not be surprised if that was the case, it and explains both these things. The HP lockout itself tripping, well... you found a few causes for that I'd say.

    • @throttlebottle5906
      @throttlebottle5906 22 дні тому

      ALWAYS assume the unit ahs been breaker power cycled hundreds to thousands of times, BEFORE you get a trouble call..........

  • @carter608
    @carter608 23 дні тому +2

    I love watching the very dirty condeser coils being cleaned probably the most satisfying part of the whole video

  • @kg4muc
    @kg4muc 24 дні тому +10

    Great catch on the over heated terminals
    Might not be a problem at the moment but would be later. The Big Picture comes through once again 😅

  • @terrygrant8126
    @terrygrant8126 24 дні тому +6

    Your wisdom is very encouraging.....thank you sir.....

  • @phillip5397
    @phillip5397 22 дні тому +3

    I’ve seen people on that same carrier break the R wire coming from the terminal board with the overload wires on the blower motor. The blower motor would over amp because the set screw on the motor pulley was not tightened down and closed itself shut. So the motor would run for 20 to 30 minutes,Trip off on overload and break the 24 V to the thermostat. Therefore causing the thermostat to go blank. But when I showed up the thermostat was on

  • @kat2641
    @kat2641 24 дні тому +2

    I would haft to say my most frustrating thing is my customers who do not do any maintenance 🙄🤬🤦‍♂️ AN it seams like they always call when we are slammed an say we need you right away… You are 💯 % right!! Their lack of maintenance costs them more In R&R but I can not understand for my life why they don’t want to try and save them major repairs issues… Yea it’s more work for us to replace and repair but it pays the bills . So I do understand and appreciate your fluster… on the ice maker?? Some one had their common sense thinking up their booty!!! If they will not allow moving ?? At least a 45 deg deflection to push the heat above the air unit..

  • @c117ls7
    @c117ls7 23 дні тому +1

    Well said at the end! If only these companies could understand everything that lack of maintenance causes. There's no way emergency repairs are cheaper than routine maintenance

  • @CopeBUILT
    @CopeBUILT 20 днів тому

    Thank You so much for the video, and all the information. Have a great rest of your day

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      Thanks bud, I appreciate the feedback

  • @Transit_Biker
    @Transit_Biker 23 дні тому +2

    That condenser is CAKED, holy cow!

  • @carloshilarionvazquezaranda
    @carloshilarionvazquezaranda 24 дні тому +2

    Buenas tardes Chris, nuevamente un formidable video y sigo muy impresionado en tu manera de pensar y resolver las cosas tengo que aprender mucho de ti. Gracias por tu sencillez y enseñanzas.
    Saludos desde Coacalco Edo de México.

  • @Ykl199
    @Ykl199 23 дні тому +1

    I'm in high school and I'm dropping band as soon as I can and taking up Hvac. I wanna start my career early and learn about it.

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому +1

      Follow your passion

    • @Ykl199
      @Ykl199 19 днів тому

      @@HVACRVIDEOS Sir yes sir :)

  • @johnrider7826
    @johnrider7826 23 дні тому

    Another great video, maybe common was making a bad connection at T-stat

  • @brushben22
    @brushben22 24 дні тому +1

    Great stuff as always

  • @zekenzy6486
    @zekenzy6486 24 дні тому +1

    Great video . Thank you for sharing

  • @helmsajr
    @helmsajr 24 дні тому +1

    Great job Chris. Always enjoy your videos.

  • @Fluxkompressor
    @Fluxkompressor 24 дні тому +3

    What I always wonder when you clean a condenser every week or 2: (that's very satisfying to watch by the way)
    I have a Split AC with 5 inside units which runs all Summer for cooling and all Winter for heating.
    Its been about 4 years since I've installed it, I looked thru the condenser the other day and it was clean like new
    You must have some dirty air there. How do you guys breathe?
    Yes, I know, dessert and stuff....
    My unit is hanging 20ft high on a wall with no trees, exhaust fans or a dirty rooftop in de vicinity. I was almost disappointed not having to clean it

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому

      Lol, I can imagine how fun that must be

    • @DBVintage
      @DBVintage 24 дні тому +1

      It’s probably because your unit runs as a heat pump. When it’s running in heat mode, the condenser will frost up like an evaporator since it basically is the evaporator when the system is in reverse cycle mode. As the system defrost, a lot of the dirt, probably washes away.

    • @Fluxkompressor
      @Fluxkompressor 23 дні тому

      @@DBVintage That's what I thought too. The climate here is more on the heating than on the cooling side. Its like 1h cooling vs 10h heating, so the outdoor part is a evaporator for most of its duty.
      Alec from technology connections made a video about his split AC
      This thing runs the condenser fan in reverse full blast after it has shut down the compressor when it satisfied the indoor temperature to blow of any dirt that might have been caught by the condenser
      That is a really nice trick. But my unit doesn't seem to do this I think. Why isn't this a wide spread technique on equipment like this, exposed to dirty environments?

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 24 дні тому +1

    Starting with the basics and easier type repairs can solve many issues. Its not always some intricate elaborate issue.

  • @ni_wink84
    @ni_wink84 24 дні тому +1

    I don’t know why but I always loved cleaning the condensers. Everyone else hated PMs and that was like my favorite thing to do, check belts, clean coils, replace filters, especially coils though it was like a competition in my head to see which unit had the most crap come out of it 😂😂😂😂

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому +1

      It's oddly satisfying and rewarding at the same time

    • @ni_wink84
      @ni_wink84 20 днів тому

      @ when I was a brand new tech that was my only job, even though I had a ton of schooling and experience previously I was the clean it guy, learned to love it lol

  • @jamiekingston9189
    @jamiekingston9189 24 дні тому +2

    Airflow is king!

  • @Pippy626
    @Pippy626 24 дні тому +11

    Some day ACs will require a water hookup and have a system to auto clean the coils

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому +6

      Or at least city code will require rooftop water sources

  • @thesilentonevictor
    @thesilentonevictor 24 дні тому +1

    Big picture diagnosis master

  • @SproutyPottedPlant
    @SproutyPottedPlant 24 дні тому +3

    Wow look at that poor condenser, it’s got everything against it with dirt, ruined fins, wrong fan motor and ice machine blowing on it and yet it keeps going ! Also satisfying seeing the dirt come off the various coils 😊👍

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому

      It really was fighting for its life

  • @Shmash_whatever
    @Shmash_whatever 24 дні тому +5

    Is this one of the units where 24v hot runs through the blower overload? Could explain a thermostat that went blank and then came back on

  • @calex9398
    @calex9398 24 дні тому +1

    Very nice my friend

  • @Critter145
    @Critter145 24 дні тому +3

    “Hurry, we don’t budget for preventative maintenance!”
    That’s what I heard when I read the title.

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому

      Lol, that might be reading between the lines a bit

    • @Critter145
      @Critter145 24 дні тому

      @ perhaps🤣. It was true in the restaurant I worked🤦🏻‍♂️

  • @lavina58
    @lavina58 25 днів тому +2

    Awesome 🙌🙂👌🍀

  • @kmerc609
    @kmerc609 20 днів тому

    Never underestimate the customers ability to cycle power from the breaker. Worked with a guy who went to test voltage on an open air case and the customer had been resetting the breaker due to high head pressure. Dude got a flamethrower in the face.

  • @bassmaster2009
    @bassmaster2009 24 дні тому +1

    That spray bottle is sick
    Can you plz share the link for it
    Thanks.

  • @Critter145
    @Critter145 24 дні тому +5

    The same people who won’t pay to prevent problems and save money in the long run are the same people who think mining rare earth elements, mining copper, cobalt etc., and shipping the car around the world twice is more energy efficient than buying a gas car made in the same country.

  • @ayyy8467
    @ayyy8467 23 дні тому +2

    Could you please show us how you connect to measure quick and set up

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      I have a bunch of videos that show that process, but on my next one if I have time I'll see if I can do a little something along those lines.

  • @furiousotter1039
    @furiousotter1039 19 днів тому +1

    As a technician in south Florida with regular 60+% humility seeing 30+ degree temp splits shocks me. Whats the humidity in your area?

  • @taylorj9920
    @taylorj9920 24 дні тому +3

    You could of rotated the I/M condenser in like 1 min to kick the discharge away from rtu cond inlet

    • @HVACRVIDEOS
      @HVACRVIDEOS  23 дні тому +1

      Nah the lines could begin leaking if I started moving them, it needs to be a planned event not a thing we just do on the fly

    • @taylorj9920
      @taylorj9920 16 днів тому +1

      @HVACRVIDEOS
      Those hoshi fittings are solid they don't leak unless you do something dumb or loosen them
      Quick small twist of cond and if anything a ¼ turn from your Cresent to make sure they didn't bump
      and that would of eliminated a large portion of the direct discharge - recirc in less than 5 min..

  • @1966jcar
    @1966jcar 24 дні тому +2

    turn them 90% to left those split condenser

  • @wtfux
    @wtfux 24 дні тому +2

    For split multi row condensers, would a thin water wand be of use? Something like a fixed rain head style shower head on a pole, so it sorta looks like a flat shovel so the whole thing is as thin as the wand pole itself to squeeze between the condenser rows?

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому

      It could but there would be drawbacks

  • @jordanhenshaw
    @jordanhenshaw 24 дні тому +1

    I wonder if the breaker tripped and Joe Shmoe just flipped it back cuz it looked weird.

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому

      Thats possible or it was reset when the lights where kicked off at the end of the night

  • @makeitcold6649
    @makeitcold6649 24 дні тому +2

    There’s harder ways to make less money than washing coils, especially if it happens to occur after hours. Easy money😂

  • @ivoryjohnson4662
    @ivoryjohnson4662 24 дні тому +1

    I am thinking the condenser fan will run in reverse on a timed basis kinda like construction equipment radiator fans do to clear the radiator.

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      True mfg has a line of coolers that do something like that, it doesn't work as well as you'd think

  • @kenward9968
    @kenward9968 24 дні тому +1

    Hey Chris, Is there a common on the t-stat?

  • @DESUDESU24
    @DESUDESU24 24 дні тому +2

    Why not attempt to rake up that big section of flattened fins? Yeah it may fall off due to degradation, but wouldn't it be better to have airflow with a little bit of metal missing as opposed to no airflow rendering a big section of the condenser useless?

  • @chrislawson1233
    @chrislawson1233 21 день тому +1

    Equipment owner can't afford regular maintenance because they spend all their money on emergency service calls to deal with issues that could be prevented with regular maintenance.

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому +1

      It's the ol chicken before the egg situation

  • @robertspadezhinton
    @robertspadezhinton 24 дні тому +1

    Can you put a barrier between that unit so it won't blow on the other unit.?

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      Possibly, like some sort of air diverter

  • @slamdvw
    @slamdvw 24 дні тому

    Can you ( with customer approval, of course ) put "reverse rotation fans" on the ice machine condensers?

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому +1

      I suppose you could but it might affect the performance

  • @UnfixingDread52
    @UnfixingDread52 15 днів тому +1

    What app do you use for your pressures?

  • @torinbrown8196
    @torinbrown8196 25 днів тому +4

    25 seconds posted and I'm the 19th to view ❤
    Shit hot brother 😂

    • @jontank
      @jontank 24 дні тому +2

      i think the channel members get early access to the videos

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому +1

      Bang

  • @suezq74
    @suezq74 24 дні тому +1

    1:53 R22 🤮(I hate R22 because it’s bad for the ozone layer) - Riley

  • @winch1587
    @winch1587 11 днів тому +1

    Anyone knows where I can get 'generic' condensing units without compressor? I'm not in the USA, with many ac's with corroded and punctured condenser coils with no way to get oem replacement coils. Replacing equipment is too expensive.

  • @LilyRoseElectric
    @LilyRoseElectric 21 день тому

    Great job 👏 Are you hiring by chance?

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому

      I am not at the moment but feel free to email me a resume hvacrvideos@gmail.com

  • @prettycureforever7102
    @prettycureforever7102 24 дні тому +1

    Only in la most big rtu are r-22 smh

  • @ReferBoyz
    @ReferBoyz 23 дні тому

    Tools / tool bag load out video soon ?

    • @HVACRVIDEOS
      @HVACRVIDEOS  20 днів тому +1

      I'll jot that down and see what I can do

  • @musicnerd72
    @musicnerd72 23 дні тому +1

    How in the heck did that condenser coil get flattened on the right side like that?

  • @DanT271
    @DanT271 24 дні тому +2

    If you have the clearance you could turn those condensing units sideways?
    No consideration for the AC when they installed them
    Lack of maintenance? Pay me now or pay me later

  • @dannywalsh840
    @dannywalsh840 24 дні тому +1

    What do you blurs out on the bottom of your iPad please

    • @HVACRVIDEOS
      @HVACRVIDEOS  24 дні тому +1

      That's super secret information

    • @m9ovich785
      @m9ovich785 24 дні тому +1

      I spotted some random No's that looked like GPS locations.

  • @uxwbill
    @uxwbill 24 дні тому +4

    Being a one man show who does HVAC/R part time at best, MeasureQuick's usurping the ability to take screenshots earned it an immediate vacation. Still debating whether to give them a second chance...

    • @LasVegasVocalist
      @LasVegasVocalist 24 дні тому

      Why would they do that?

    • @uxwbill
      @uxwbill 20 днів тому

      @@LasVegasVocalist I suppose it depends upon how charitable one wants to be in their assessment. About a year ago, MeasureQuick announced that in order to do certain things, they wanted you to buy these things called Qbits. You "spend" them running reports on systems that you'd serviced. To that end, if you took a screenshot of MQ, you'd risk your account being banned for having done so.
      As I have Testo stuff rather than Fieldpiece, and it seems that MQ only "merely" supported Testo stuff for the longest time, I just went back to the Testo provided apps. Once bitten, twice shy.

  • @throttlebottle5906
    @throttlebottle5906 22 дні тому

    oh, heaven forbid the the "office" folks have to break a sweat or lift a finger to continue completely messing up most everything they touch or do...

  • @steveblake8766
    @steveblake8766 24 дні тому +2

    356th thumbs uP