SUN GTIL2 1000W with limiter after one year of use

Поділитися
Вставка
  • Опубліковано 30 чер 2021
  • SUN GTIL2 1000W with limiter after 1 year of daily use.Gain like 700Kwh solar production..it could be more with more solar panels..
  • Наука та технологія

КОМЕНТАРІ • 22

  • @benkanobe7500
    @benkanobe7500 2 роки тому +2

    Thank you so much for this information. I just purchased two and am looking forward to getting them set up. I have access and the space, is there a limit to how much my panels can supply without hurting the inverter? Thank you from San Diego, California

    • @viocaia
      @viocaia  2 роки тому

      I have 1350W PV.. and it's working fine.

  • @offgridwanabe
    @offgridwanabe 2 роки тому +2

    Yes they are very good and easy to use with solar and battery.

    • @viocaia
      @viocaia  2 роки тому +1

      I wish to have batteries for the night..It could double the harvest..someday maybe!

    • @akimi0222
      @akimi0222 2 роки тому +1

      @@viocaia i have the same inverter like you have and I'm using a 24v 180AH system LiFePO4 batteries. It increases my harvest from 1.5KW per day to 4KW. I only have 1.2KW panels at the moment.

    • @viocaia
      @viocaia  2 роки тому

      @@akimi0222 I\ll do that as soon as I can afford, it's a need!

  • @StartledPancake
    @StartledPancake 10 місяців тому +1

    Thank you for putting out this really useful video. Do you know if this inverter can work in conjunction with a standard grid tie inverter, i.e. added to an existing grid solar tie system?

    • @viocaia
      @viocaia  10 місяців тому +1

      It's working , it's a very versatile inverter.

    • @StartledPancake
      @StartledPancake 10 місяців тому +1

      @@viocaia Thank you for the quick reply! Just to confirm you already have this inverter working with another, grid tie inverter only (such an en Growatt or solis) on the same circuit? Thanks again:)

    • @viocaia
      @viocaia  10 місяців тому +1

      @@StartledPancake No, I didn't
      use it with another grid tied inverter, because this one it's already on grid, but I'm pretty sure it can work with any other inverter, you see, SUN GTIL2 it's just ''reading'' the wave on the line...I mean you can use it even out of the grid as long there is pilot 50/60Hz inverter...

  • @toastertv2243
    @toastertv2243 2 роки тому +2

    Can i know how do you connect the Sonoff Pow?
    Sun GTIL Output --> output [Sonoff] input ->> Wall
    confused.

    • @viocaia
      @viocaia  2 роки тому

      Look here ua-cam.com/video/Iqy0W1FW42M/v-deo.html

  • @MIKATI76
    @MIKATI76 Рік тому +1

    Buna!Ati avut vreodata pròbleme cu distribuitorul de energie electrica din cauza acestui invertor?

    • @viocaia
      @viocaia  Рік тому

      Nu..fiindca nu ''scapa'' extra pe retea..

  • @allzzizzwellzz5841
    @allzzizzwellzz5841 Рік тому +1

    can i connect 48v 800w wind turbine via charge controller or rectifier?

    • @viocaia
      @viocaia  Рік тому

      I think so..but look around there are special models for wind turbine, 3 phases input.

    • @allzzizzwellzz5841
      @allzzizzwellzz5841 Рік тому +1

      @@viocaia it's much expensive
      while this solar is more less cost

    • @viocaia
      @viocaia  Рік тому

      @@allzzizzwellzz5841 Probably if you use a rectifier bridge to DC..or a direct DC turbine..it should work..

  • @evelbsstudio
    @evelbsstudio 2 роки тому +1

    Are these stackable on the same phase on the grid side?

    • @viocaia
      @viocaia  2 роки тому +1

      Yes, they are.

    • @evelbsstudio
      @evelbsstudio 2 роки тому +1

      @@viocaia ah brilliant, just ordered the 22-65v 1000w version to go with my small solar shed..
      Going to have to extend the sensor cable because my electric meter is 29m away lol..
      This is going to save me having cables everywhere from the inverter to the fridge freezer, TV, router, NAS, Alexa's, CCTV system etc..
      Now what to do with the existing inverter lol

    • @viocaia
      @viocaia  2 роки тому +1

      @@evelbsstudio I'm not sure if you can use the same sensor for both inverters...but for sure you can use two of them on the same phase