How to replace a combustion control unit on a Baxi Heat Only boiler

Поділитися
Вставка
  • Опубліковано 30 січ 2025

КОМЕНТАРІ • 58

  • @charlieteer6162
    @charlieteer6162 Рік тому +1

    I've got one of these to do tomorrow. I've never done one before. Cheers for the video.

  • @Kiangaf
    @Kiangaf Рік тому

    Came across this issue today on a job. I appreciate the video. It’s not a popular Baxi model around here. It’s an expensive part and the customer only had the unit installed in 2017. Hopefully they are still in warranty.

  • @peterromaniuk5771
    @peterromaniuk5771 10 місяців тому +1

    All now working again....👌In total with the failed Combustion Control unit & the incorrectly fitted 30Kw one, it has had 4x Combustion Control Units fitted in the last 10-days!!! @ over £320 a pop, not cheap......Looking forward to more videos...

    • @cputilitysolutions
      @cputilitysolutions  10 місяців тому +1

      Wow that's crazy! Main thing is it's sorted now. Just goes to show why part numbers are so paramount to the boiler you're fitting it to when it comes to combustion

  • @alfiespencer1161
    @alfiespencer1161 Рік тому +1

    Quality video, really helped me out for my first time replacing one

  • @IJHougfhton
    @IJHougfhton Рік тому +1

    Save me alot of reading and frustration today pal ,top marks....Cant say having to change all 3 items is progress in the boiler world....madness 300 quid for parts to

    • @cputilitysolutions
      @cputilitysolutions  Рік тому +1

      Thanks mate, yeah it's a poor design on the combustion control unit

  • @kynohunt126
    @kynohunt126 2 роки тому +1

    Brilliant watch, you taught me every step of the way!! Need guys like you 👌🏽

  • @brendanfisher2528
    @brendanfisher2528 3 роки тому +2

    I had this issue with one of these but could not seem to get the parts for it as seemed to be to new at the time. :/ also surprised baxi sent washers etc. As they hardly never send washers or o rings or seals.

  • @jamesknowles550
    @jamesknowles550 Рік тому +1

    Hi -- yes iv'e done a couple of these burner units -- both boilers were just out of guarantee -- one a baxi 224 combi and one a potterton titanium 18kw heat only -- both units are fan , pcb + gas valve -- and what i think is that on both occasions the units failed when the boilers were in demand + the power went off -- ether a pre payment meter running out or the power being turned off at the consumer unit for some reason -- and then the power put back on while the boilers were still in demand !! your well right it's got to be poor manurfacture thats causing this in the first place -- i like your videos take care Jim .....

    • @cputilitysolutions
      @cputilitysolutions  Рік тому +1

      Thanks Jim glad you enjoy the videos 👍🏽 the unit is pretty straightforward to change but a rip-off how it's built!

  • @jamesparry175
    @jamesparry175 2 роки тому +1

    Awesome video, have one to replace on Thursday so this has helped me loads thanks for uploading 👌👌

  • @ImranAhmed-fr8ds
    @ImranAhmed-fr8ds 3 роки тому +2

    Fantastic video mate, love your videos. Keep em coming. Very beneficial. Keep doing what your doing.👍🏽

  • @boilers24-7
    @boilers24-7 3 роки тому +1

    Great video mate , clear & concise.👊🏾

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 11 місяців тому +2

    Does it come with new fibre?

    • @cputilitysolutions
      @cputilitysolutions  11 місяців тому +1

      For the gas connection yes

    • @lostinthoughtscalminsilenc8167
      @lostinthoughtscalminsilenc8167 11 місяців тому +1

      @@cputilitysolutions for the setting up of gas valve, is it turn it on and then adjust? Just as some always say turn 8 times etc

    • @cputilitysolutions
      @cputilitysolutions  11 місяців тому +1

      @@lostinthoughtscalminsilenc8167 yes put it in service mode and then adjust as you take your readings 👍🏾

  • @avnishkumar9118
    @avnishkumar9118 3 роки тому +1

    Great video mate!never done the adjustment on gas valve on these but now I know.cheers for! that mate

  • @macpatel7810
    @macpatel7810 3 роки тому +3

    Another great video CP. Great step by step explanations as usual. Top stuff. Also, who is the idiot with the dislike.

  • @richardgransden2375
    @richardgransden2375 3 роки тому

    Thanks for the video , did my first one today and your video helped me out .👍

  • @abualam4418
    @abualam4418 3 роки тому

    Your video’s are very helpful to us,
    Thank you

  • @peterromaniuk5771
    @peterromaniuk5771 10 місяців тому +1

    Hi, A quick question, Just had a failed Fan on one of these, a EcoBlue Advance Heat 25 ERP, British Gas came out & replaced it, the Capacitor on the Motherboard had Blown. The Man from BG then struggled to set the correct Max/Min CO2 Settings? Is there a "Base" Setting for the Adjustment screws? ie All the way in or all the way out? From which you can then carry out fine adjustments? He thinks it might be a faulty Gas Valve on the New Combustion Control Unit? I know that new parts do fail, but I'm only the homeowner & not a BG Gas Registered Fitter, But before he condemns the newly fitted Combustion Control Unit, it may steer him in the right direction, he said yesterday that he had never fitted a replacement Unit before, which doesn't instil me with a lot of confidence. Thanks for any feedback that you can provide....

    • @cputilitysolutions
      @cputilitysolutions  10 місяців тому +1

      Hi, all the combustion control units need setting up out of the box. All he needs to do is to check the instructions for commissioning and all the information is in there on how to adjust the gas valve. Max rate has to be between 9.2-9.4% CO2 and the minimum has to have a 0.4% difference from the max

    • @peterromaniuk5771
      @peterromaniuk5771 10 місяців тому +1

      Thanks for Your Reply, I have the Service Manual, so will photocopy it & laminated it & leave it conveniently by the Boiler!!!!😇 @@cputilitysolutions

  • @mrman3509
    @mrman3509 3 роки тому +1

    Great video. Very clear 👌

  • @peterromaniuk5771
    @peterromaniuk5771 10 місяців тому

    Hi, It turns out that the first Combustion Control Unit the BG Gas Fitter fitted was for a 30kw Boiler BAXI Part Number 7786339 & not for the 25kw Boiler that we have & that is why he couldn't set the MAX & MIN CO2 Readings!!!! He came back the next day with the correct Baxi Part Number 7775020 But now there are 3 Red Flashes instead of 4!!! which is an ignition Fault according to the Service Manual. He says the Gas Valve isn't opening?? Could he of damaged something else by fitting the Incorrect Combustion Control Unit in the first place??

  • @manjsingh6500
    @manjsingh6500 3 роки тому +1

    Brilliant video 👍👍👍

  • @aminsajawal3935
    @aminsajawal3935 3 роки тому +1

    Great video brother thanks 🙏

  • @peterromaniuk5771
    @peterromaniuk5771 10 місяців тому +1

    Just to add, I complained to BG about the persevered capabilities of the first Engineer, he was blaming his stores for sending the incorrect part? BG are sending out a "senior" Engineer tomorrow for a second opinion. It maybe that the 2nd Combustion Control Unit has a faulty Gas Valve, so needs a 3rd Unit, But the Original Gas Fitter wasn't prepared to sanction another one, So to be prepared for tomorrow, is there anything that you can check for a faulty Gas Valve? Is there a setting on it that maybe closed, or is it a case that it either lets Gas through or it doesn't?

    • @cputilitysolutions
      @cputilitysolutions  10 місяців тому +1

      Sorry to hear of your troubles, there's also a coding chip which is programmed to the boiler so to make sure that's been fitted as well

    • @peterromaniuk5771
      @peterromaniuk5771 10 місяців тому +1

      Thanks, TBH I don't know what the first BG Gas Fitter has fitted, to me he seemed way out of his depth & was on the phone to BAXI the whole time, from what I see from your video, it should be quite straightforward. I just hope that he hasn't damaged something else by fitting the 30kw Combustion Control Unit first? That is my major concern ATM. From a simple replacement of a failed PCB, I could potentially be looking at a replacement Boiler, if the person tomorrow can't fix it...I tried my best getting a reputable household name in & it seems to have backfired on me big style.....

    • @cputilitysolutions
      @cputilitysolutions  10 місяців тому +1

      @@peterromaniuk5771 I don't think you have anything to worry about, as you're covered by BG they will have to get the boiler running for you. Hopefully the new correct combustion unit will sort it

    • @peterromaniuk5771
      @peterromaniuk5771 10 місяців тому

      Well that's not what the first Guy said!!!! After 3-Days he just turned around & said "That's it's I can't fix it!" & washed his hands of it....Said that he would speak to his Manager & get the HomeCare Contract cancelled & refund me what I've paid......He said, he couldn't sanction any more replacement parts as they are so expensive!!!! No Shit I said.....Hence I complained & hence the "Senior" BG Engineer fingers crossed coming out tomorrow for a second Opinion.....

  • @daddybassi
    @daddybassi 3 роки тому

    Where does the RCD key located?

  • @leaturk11
    @leaturk11 3 роки тому +1

    nice job

  • @simonmander4314
    @simonmander4314 3 роки тому +1

    Great vid thanks. How do you rate these boilers?

    • @cputilitysolutions
      @cputilitysolutions  3 роки тому +2

      They're decent heat only boilers, I believe there was a bad batch manufactured with this fault, and apparently it happens more on Y-plan systems someone who works for Baxi told me.

    • @simonmander4314
      @simonmander4314 3 роки тому

      @@cputilitysolutions thanks.

  • @harwoods11
    @harwoods11 2 роки тому

    Why do these units fail like this?
    My daughters new house is just 3 years old (stood empty for first year) and now the 4 red led flashes. Fan spins freely.
    Obviously a pcb component has failed.
    I assume this is not a DIY job as the gas valves etc need to be reset and calibrated.

    • @cputilitysolutions
      @cputilitysolutions  2 роки тому +1

      It seems to be a manufacturing flaw as I've changed quite a few of these now. As long as the boiler was registered you should still have warranty on it so best to give Baxi a call and definitely NOT a DIY job!

  • @Smokeblow
    @Smokeblow 2 роки тому

    Amazing 👊

  • @peterromaniuk5771
    @peterromaniuk5771 10 місяців тому

    Latest Update, Senior BG Gas Engineer has ordered a replacement for the replacement, not happy with the Gas valve Electrical Readings, thinks that the Gas Valve has blown the PCB? Replacement due to be fitted tomorrow......🤞

  • @paulsmith2931
    @paulsmith2931 2 роки тому +2

    Bet that cost nearly the price of the complete boiler, baxi are a rip off how they design some of their boilers that you have to change half the boiler because of one component failing.

    • @cputilitysolutions
      @cputilitysolutions  2 роки тому

      It's true, costs around £500 I believe. However if you have the warranty cover then at least you'll have some peace of mind for that many years

  • @chrishard7616
    @chrishard7616 2 роки тому +1

    Well this has just convinced me not to buy a Baxi 400 series if you can’t just change the fan that is doomed to fail in a short life time. Ridiculous design!

    • @cputilitysolutions
      @cputilitysolutions  2 роки тому

      Yes and no, there was a faulty batch produced but they've rectified the issues now. Also you'll get between 5-10yrs warranty depending on which model you go for so you wouldn't have to pay for the repair if needed within that time. I still fit a lot of these Baxi heat only boilers as they're easy to install, don't require a permanent live or pump overrun, and have a rear flue option as well. Don't be put off by the repair! 😉

    • @chrishard7616
      @chrishard7616 2 роки тому

      @@cputilitysolutions Even if they are now better, conceptually, to have the fan integrated into the unit like that is just plain stupid. It's a mechanical device that will eventually fail and should be changeable easily and at low cost. To replace it in the future is around 3/4 the cost of a new boiler, plus there is the labor charge to add, crazy design so I wont be getting one, even though I think as a boiler when its working properly it's probably a good choice. Why on earth can't they make it so the fan can be easily changed at a sensible cost? Oh yes, it's so they can rip people off for overpriced spares! I've got a Glowworm Spacesaver that is now 33 years old and is still working fine, granted it's not very efficient but it's cost virtually nothing to maintain just requiring 3 fans in it's life.

  • @adrianingham1560
    @adrianingham1560 3 роки тому +4

    Stupid design. It's like changing a car engine just because the water pump goes. I replaced with new boiler.

    • @nathd1748
      @nathd1748 2 роки тому +2

      Yes absolutely idiotic design just because a fan has busted.

    • @chrishard7616
      @chrishard7616 2 роки тому +1

      @@nathd1748 absolutely stupid and designed to cost you lots of money in repairs.......should be made illegal

  • @amerriaz10
    @amerriaz10 Рік тому

    i will not be recommending baxi to my customers. vaillant only

  • @amerriaz10
    @amerriaz10 Рік тому

    £360 for the part. rip off

  • @jockster5525
    @jockster5525 2 роки тому +1

    Quality mate 💪