LAFD Light Force 94: Sheared Hydrant

Поділитися
Вставка
  • Опубліковано 18 жов 2024

КОМЕНТАРІ • 753

  • @mackflickerson6722
    @mackflickerson6722 4 роки тому +477

    For those who are less familiar with the make-up of the water supply system in the Los Angeles region, understand that the L.A. Basin is essentially a desert for many months of the year. Domestic water is brought into the region from hundreds of miles away through aqueducts, and stored in reservoirs. The water supply is, in many cases, both fragile and finite.
    Having a 2,000GPM "leak" in the water system for more than a few minutes can really begin to take a toll on the system's capacity and capability, both for firefighting water and for potable water. For this reason, the FD is tasked with and trained for emergently containing leaks from sheared hydrants.
    And L.A. uses wet-barrel hydrants; the water comes up the barrel right to the caps, even when it's turned off. This is beneficial to them because each cap has its own valve, and supply lines can be connected/disconnected while other lines on the same hydrant remain flowing. This is why there's no cut-off valve when the hydrant is sheared.
    As always, be reminded that it isn't wrong just because it isn't the way your department or city does it.

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому +54

      thank you!!!!

    • @darrenalexander8881
      @darrenalexander8881 4 роки тому +24

      Interesting. Thanks for the FYI. Me living in a city that's water supply comes from a Great Lake (Cleveland) our water supply & shut-off systems are totally different.

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому +20

      Mack Flickerson I’m not sure if that was directed at me , but I never implied that it was wrong , and anyway my Fire Dept has nothing to do with installing or maintenance of Fire Hydrants , the Water Dept handles that. It’s not our choice nor do we care ... in areas like NYC or anywhere that is exposed to prolonged freezing Temperatures we MUST have Dry Barrel hydrants , other wise they would freeze & be unusable in a winter months . It’s just a added bonus that dry barrel hydrants also don’t become a Geyser of water when sheered off ... I honestly thought that was only stuff that was i the movies because in 24 years working & 47 years living in the NYC area I have never seen a fire hydrant shoot water 40 feet into the up I to the sky . Only seen in it movies until this video & i have seen many hydrants knocked over by cars in my life . I was only commenting on who repairs & maintains hydrants . Although the fire department I work at & many others I know of on the east coast Regularly do fire hydrant inspection just to make sure they’re functioning if we find a hydrant That isn’t functioning we notify the water department... ok enough fire hydrant talk I hope 🤞

    • @rickgeller6043
      @rickgeller6043 4 роки тому +11

      Wow, you are so smart. Maybe you could an in-depth video about fire hydrants.

    • @anthonythorp7291
      @anthonythorp7291 4 роки тому +8

      Very interesting and very different from our hydrants.
      Seems to me if water is that valuable, an extra shut off valve would be money well spent.

  • @WannaBeHocker
    @WannaBeHocker 4 роки тому +15

    These firefighters gained a new appreciation for warm dry socks!!!
    Job well done!

  • @centralnewyorkresponses7887
    @centralnewyorkresponses7887 4 роки тому +221

    “Mom, I fixed the pressure issue in our garden hose”

    • @anthonythorp7291
      @anthonythorp7291 4 роки тому +23

      "Did you water the garden?"
      "Yep. The garden, the lawn, the street, even washed the car."

    • @danielfirecopter
      @danielfirecopter 4 роки тому +5

      @@anthonythorp7291 😂😂😂😂😂😂 good one

    • @Mrlopez-tg2nz
      @Mrlopez-tg2nz 4 роки тому +4

      @@anthonythorp7291 Good shet son!!
      I almost shet out the enchiladas! Good laugh 😆!!!

    • @alfredperea9771
      @alfredperea9771 3 роки тому +3

      @@anthonythorp7291 and the firemen came to congratulate me:) -good one-

    • @dhshenddhdj8708
      @dhshenddhdj8708 3 роки тому

      اااااتتتتلعاءلبئليلءترنىسيئؤنة

  • @kkerr1953
    @kkerr1953 2 роки тому +126

    A little disappointed that you spent so much time filming this and didn’t catch the actual shutting off of the geyser! 😢

    • @melvinojr7318
      @melvinojr7318 2 роки тому +7

      I agree.

    • @GETMONEYJONES2304
      @GETMONEYJONES2304 2 роки тому +4

      I know what

    • @roler8036
      @roler8036 Рік тому +2

      Yes I was also expecting to see the water fountain fading away and shut down.

    • @Gunawan-uz4cy
      @Gunawan-uz4cy Рік тому

      35ė

    • @RhetroRP
      @RhetroRP 3 місяці тому

      It’s disappointing that they turned the wrong shutoff. As a plumber, even I was thinking “why aren’t they shutting it off from the box in front of the hydrant

  • @staceyjackson8014
    @staceyjackson8014 Рік тому +2

    Watching your video, bring back many memories of growing up in the L.A. area and a fire hydrant happen just like your video. I lived there from 1969-1991.

    • @videolover1489
      @videolover1489 Рік тому

      You must be a last sane conservative person who left LA area before it became a shithole

  • @anthonyjackson1446
    @anthonyjackson1446 4 роки тому +13

    I like the new lime green safety coats i see the LAFD has purchased , that’s truly different for them to do that...👌🏽👍👍

  • @christopherhulse8385
    @christopherhulse8385 4 роки тому +46

    I'm from England and the only time I saw this happen is on films when cars always seemed to hit a hydrant!

    • @henryreeder5939
      @henryreeder5939 3 роки тому +4

      Yeah our hydrants aren’t built in like American ones there just holes in the ground and then fire dep puts the end in

    • @Thestuffnope
      @Thestuffnope 3 роки тому +5

      @@henryreeder5939 but then you have the chance that some idiot could park their car directly on top of the water source. But i guess that would depend on location.

    • @nevillemason6791
      @nevillemason6791 3 роки тому +2

      @@Thestuffnope The other problem is being below ground, the chamber can silt up so the first task can be to dig out the crap to find the valve.

  • @thatzombieplace
    @thatzombieplace 4 роки тому +103

    Haha I felt bad for the guy that had to get in there with their hands

    • @soccerboy22100
      @soccerboy22100 4 роки тому +11

      i think that was a woman

    • @stumckoo5978
      @stumckoo5978 4 роки тому +6

      Least senior member of the crew is my guess

    • @sheriffdan4714
      @sheriffdan4714 4 роки тому +1

      Also put a board in the way, the high pressure would leave your hand bruised

    • @timothyfrollini5383
      @timothyfrollini5383 4 роки тому

      Rookies for sure!!!!!

    • @MarcPhillip911
      @MarcPhillip911 3 роки тому +1

      @@timothyfrollini5383 yeah ok let's us see you do smart ass

  • @EightiesTV
    @EightiesTV 3 роки тому +27

    If they understood that hydrants are tapped off the main using a saddle connection with the valve located between the tap and the hydrant 2 to 10 feet directly from it, they wouldn't have wasted time operating the wrong valve 60 feet from the hydrant.

    • @thetapper61
      @thetapper61 3 роки тому +5

      They just didn't want to get wet. They were trying to shut the block off first, then shut hydrant gate, then reopen block.

    • @paulmonk7820
      @paulmonk7820 2 роки тому +5

      @@thetapper61 looks like they didn't know where the valve was.

    • @kennyw871
      @kennyw871 2 роки тому +2

      Training video.

    • @joemagliari11
      @joemagliari11 2 роки тому

      Im sure you can google their station, contact them and forward them the same information.... they wont see it commented on a UA-cam thread... tyfys

  • @scottminer7702
    @scottminer7702 3 роки тому +14

    Well done. We had to call City Water Works to shut off broken or frozen hydrants. Winter here in Canada made it more interesting creating really cool ice sculptures.

  • @tombo552001
    @tombo552001 2 роки тому +5

    We use to paint our hydrant valves half blue half yellow, it made it easy to know what was a hydrant valve.
    You might look at the other hydrants to see where there valve is located.

  • @bryandepaepe5984
    @bryandepaepe5984 4 роки тому +34

    This is a common sight after I visit Los Santos.

  • @richardwelch4653
    @richardwelch4653 Рік тому +1

    The house on the corner going to have some real nice green grass.

  • @sabereaseera1384
    @sabereaseera1384 3 роки тому +41

    Damn didn’t know everyone was suddenly a fire hydrant expert

    • @FB1ResponseVideos
      @FB1ResponseVideos  3 роки тому +7

      thank you!! lol

    • @meaninglesscog
      @meaninglesscog 3 роки тому +9

      Shoot, everyone on UA-cam is an expert on everything in the video AND world politics and how much America sucks compared to every single other country on the face of the Earth. Wonder if it is like this too on all of those other massive video streaming services based in all of those other better countries.

    • @danmilosevich
      @danmilosevich 3 роки тому

      Fire hydrant, fire fighting, paramedics, police, pilots, tow trucks, military, funerals. If it is on UA-cam then there is an expert for it. Or it is done the right way at the commentors place and wrong at the video place. Grin.

    • @kp5106
      @kp5106 3 роки тому

      I’m I Hebrew did utility work here in the south, light, gas, and water.

    • @josephastier7421
      @josephastier7421 3 роки тому

      It's UA-cam. We do it all here.

  • @flyoverkid55
    @flyoverkid55 3 роки тому +2

    The joys of being the station rookie.

  • @pg396
    @pg396 4 роки тому +17

    Those guys are standing under a lot of falling water. Wow. Like a decent Waterfall in the Sierras.

  • @geomodelrailroader
    @geomodelrailroader 2 роки тому +2

    I remember on Emergency where they had this unusual call. The Squad has to extract the driver of the wrecked car and the engine company has to turn off the main until a new hydrant is installed.

  • @Swoose17
    @Swoose17 2 роки тому +4

    It is what it is. I have heard a lot of calls for these over the decades but this is the first time I got to see what happens once they arrive on scene. Thanks for the video.

    • @davecruz9893
      @davecruz9893 2 роки тому

      THERE YOU GO......NOTHING !!!! TWENTY MEN DOINE A ONE MAN JOB....TYPICAL FIRE RESPONSE....

    • @princessrocha6910
      @princessrocha6910 Рік тому

      sabahay

  • @winnerLEE-s8s
    @winnerLEE-s8s 3 роки тому

    The most noble job in the world.
    I give you love and respect.
    in korea

  • @stevef7142
    @stevef7142 3 роки тому +9

    In a system that large I would be surprised if the pump station even noticed this.
    I worked got the WW for 7 years in IN. A contractor tying in an water tower knocked off the 24” valve, took 10 mins before pump station saw the drop in pressure. Contractor called screaming in about a minute. We had it shut off in 40 mins. I think I heard we lost over a million gallons.

    • @dons8122
      @dons8122 2 роки тому

      if it is down below the hills in LA it is all gravity fed even then some of the houses up on hills are still getting plenty of pressure with no pumps

  • @doug.afc.90.93
    @doug.afc.90.93 2 роки тому +1

    Wouldn't bother about having a shower would ya if you was the fireman under that waterfall 😂

  • @equipment-enthusiast
    @equipment-enthusiast 4 роки тому +31

    I hate when people leave the scene of a crime ! Hopefully someone seen who hit the hydrant.

  • @Foxtrot07gamer
    @Foxtrot07gamer 3 роки тому +11

    Legend has it it’s still going

    • @eddiebarrera469
      @eddiebarrera469 3 роки тому

      Their trying to figure out,lefty tighty ,right loosy.

  • @jailanimajid6115
    @jailanimajid6115 3 роки тому +7

    Salute to the firefighters.Good job.

  • @overbank56
    @overbank56 4 роки тому +36

    Well done guys! I know you were exhausted! At least the " geyser" was water & not a gas line leak. I wonder how much water was lost?

    • @jayasmrmore3687
      @jayasmrmore3687 3 роки тому +2

      It’ll all get evaporated and then the water cycle anyway

    • @thisismyusername6717
      @thisismyusername6717 3 роки тому +1

      @@jayasmrmore3687 ground absorbtion and re-location of water where water was already needed.

    • @jayasmrmore3687
      @jayasmrmore3687 3 роки тому +1

      @@thisismyusername6717 meaning?

    • @thehoneybadger8089
      @thehoneybadger8089 2 роки тому +2

      About 2000gal/min if they have a half decent system.

  • @wannabetowasabe
    @wannabetowasabe 4 роки тому +9

    I'm surprised not to see a comment about why two pieces of apparatus were sent. In this case LAFD ladder trucks have no pumping capability and no water tank so a regular Type I engine always accompanies the ladder truck. They always have an engine number that is 200 above the truck. Here this is Truck 94 accompanied by Engine 294. Station 94's regular engine would be Engine 94. At station 101 you would have a Light Force with Truck 101 and Engine 301. There are single Type I engines and some stations with only a single engine. When a regular engine joins a "Light Force" it is then called a "Task Force." At the time of this call, the regular Engine 94 might have already been assigned or is one with a paramedic on board, so they might give the hydrant calls to Light Forces only, I don't know.
    I imagine it is now DWP's job to make the repairs to place a new hydrant at the location. Years ago, now some 47 of them, when I lived in L.A., the LAFD had "plug buggies," which were a pickup with a single firefighter. I think they did preventative maintenance and tested the hydrants to make sure they were working on some sort of schedule, like once a year or something. Do they still use those units?

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому +1

      i'm sure someone will come along with that question soon!
      you're correct, truck companies carry hydrant shut off keys so all incidents involving a sheared hydrant will get at least a light force.
      and correct again, once the hydrant is shut down, the captain will contact metro and request "DWP for a sheared hydrant shut down at the intersection of..." followed by the location of the incident.
      Plug Buggies are still around. however, from what i've seen, during annual hose testing, the entire task force (and sometimes the rescues too) split the area to knock out more hydrants faster. i've really only seen plug buggies used for transferring equipment/personnel between stations, grocery store runs, reliefs of firefighters at incidents for prolonged periods of time near shift change, and other fire station needs.
      thanks for watching!

    • @wannabetowasabe
      @wannabetowasabe 4 роки тому +3

      @@FB1ResponseVideos It sounds like plug buggies are used as what CDF and federal wildland fire agencies call a "Utility."
      As for watching, you are welcome. I'm an old retired fire dog.

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому

      exactly, station utility. i hope retirement is treating you well!

    • @MidnightPolak
      @MidnightPolak 4 роки тому +1

      Interesting that the FD is sent at all. In Canada, at least in BC, the city's water operators are responsible for shutting down sheared hydrants, if they happen to be a wet barrel. Most are dry barrels, so there's no geyser when sheared off :)

    • @veachbr
      @veachbr 4 роки тому +1

      @@MidnightPolak This was my thought. Why not dispatch LA Department of Water and Power? Even if you send a Light Force, why go Code 3? What "emergency" was there in this situation? My department used to run code 3 to gas meters that were hit or leaking. A new chief (had been a CAPT with the volunteer department for ages) changed that and made it a non-code response unless we had an indication it was a fire/explosive hazard. The goal was to reduce running code 3 and the risks that entail. Just my thoughts. I'm not here to second guess these guys of LAFD doing fine work. I did notice that the CAPT (orange helmet) stayed high and dry the whole time. I guess rank does have its privileges! lol

  • @halloweenchainsawsforgoo
    @halloweenchainsawsforgoo 4 роки тому +70

    At least the grass was watered and some one got free car wash lol.

  • @curiousbat5368
    @curiousbat5368 3 роки тому +4

    It actuallly looks so refreshing for a city in the middle of the desert 😊 Of course not right where the hydrant is sheared but maybe just being around the zone

  • @nathanr.8556
    @nathanr.8556 4 роки тому +82

    If the valve was properly maintained that would have been a 5 minute job

    • @anthonythorp7291
      @anthonythorp7291 4 роки тому +10

      Been my experience a lot are like that. Definitely should be doing regular checks.

    • @TowGunner
      @TowGunner 4 роки тому +9

      No doubt. The video was clipped. Took much longer.

    • @Windgonner
      @Windgonner 4 роки тому +8

      Agreed, if the FD was given the necessary funding's there would be no problem. The problem occurs because Americans (in general) doesn't want to pay taxes for common needs like Fire Brigades.

    • @anthonythorp7291
      @anthonythorp7291 4 роки тому +12

      @@Windgonner want this American doesn't want to pay for is:
      Career welfare recipients.
      Unwed girls with kids.
      Lazy worthless people living off the gov aka me.
      4yr politicians term with full pensions.
      All the other ridiculous things politicians get.
      Gov pet projects.
      Fancy bridges and road ways.
      Over the top architectures gov building.
      Infrastructure in different countries.
      Multiple statues/displays being build when city should be filling potholes instead.
      Lawsuit settlements for bad cops.
      On and on.
      I have no problem paying for needed government and services that aren't wasting my tax money.

    • @nathanr.8556
      @nathanr.8556 4 роки тому

      @@Windgonner Wrong. Unless you are speaking of Trump

  • @jimaldridge4284
    @jimaldridge4284 2 роки тому +1

    Per National Fire Code if a fire hydrant is struck by a vehicle the exposed hydrant top is designed to break away from the main body of the fire hydrant to prevent a water ruptured like in video. In this case the hydrant body must have broken off from the 6" water main extension pipe servicing the hydrant, or a shear coupling was not installed for water to be shooting up to the sky like this.
    Every fire hydrant is designed to stay seated by water main pressure if the hydrant top is sheared off from the stem due to its upside down seat and disc design. Each fire hydrant is also to have its own isolation valve located 3'-5' from the hydrant. This is required to isolate only the hydrant for maintenance or replacement instead of having to isolate the entire water main loop keeping water service from homes and businesses. What's going on here is a puzzle.

    • @xxkillerkane420xx8
      @xxkillerkane420xx8 2 роки тому +1

      You’re talking about a dry barrel hydrant. This is probably a wet barrel. Your statement about EVERY hydrant is incorrect.

  • @ericl3568
    @ericl3568 4 роки тому +79

    Where's the Water Dept! They should buy the FD dinner for doing their job.

    • @josephbennett3482
      @josephbennett3482 4 роки тому +13

      The water authorities don't do Hydrants , it's the fire departments responsibility to tend to something like that , water authorities only do water line maintenance for homes and businesses.

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому +5

      That’s what I said . In the city i work as a Firefighter , this type of Incident would be handled by the City Water Dept , firefighters only go around & shut hydrants down opened up by kids to play in the water on super hot days , it’s there only way to cool down in the inner city’s

    • @josephbennett3482
      @josephbennett3482 4 роки тому +4

      @@OwneyMadden430 Hydrants are nearly impossible to open without the help of a Hydrant wrench , very few people can even get them to open and nobody definitely can't open the valve without a Hydrant tool because they are tightly shut and it requires a firefighters full strength sometimes to get the valve to budge.
      Ordinary people don't have tools large enough to open a Hydrant.

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому +8

      Joseph Bennett Really Joe ? As a Firefighter just outside NYC for the last 24 years I must have been hallucinating , because ive see it with my own eyes .. not only do they open ordinary hydrants , Have you ever heard of a magnetic hydrant wrench for hydrants that have a magnetic tip for the purpose of stopping people from opening hydrants illegally? Well Im sure you haven’t .. But the people u say can’t open regular hydrants even open these magnetic tipped hydrants with Magnets from huge radio speakers & an improvised wrench ... listen dummy idk who u are but you obviously aren’t a firefighter . So do yourself a favor and keep your idiotic thoughts to yourself seriously with all due respect ...

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому +5

      Joseph Bennett This happens to be a video in Chicago of kids who opened a hydrant to play in the water , do you see any big strong firefighters around with there full strength & hydrant wrenches? I don’t see any Joe !! So how did it open ? Soooo who opened this nearly impossible to open hydrant Joe? The Kids did you moron ... ua-cam.com/video/4-URRHLhFus/v-deo.html

  • @Quadrille763
    @Quadrille763 4 роки тому +12

    Interesting we don’t see this back east I always wondered how this was done

  • @deepierce5030
    @deepierce5030 3 роки тому +2

    11:54 "Hey Sarge, can ya give us a hand?" 11:55 "Voila, magic wand waved for ya!"
    Seriously though, great job LAFD for tackling all issues with the city!

    • @josephastier7421
      @josephastier7421 3 роки тому

      Twelve minutes of continuous video and he misses the actual shutoff.

    • @thisismyusername6717
      @thisismyusername6717 3 роки тому +1

      That guy was already in there. If he knew what to do he should of done it to start.

  • @CymruEmergencyResponder
    @CymruEmergencyResponder 3 роки тому +1

    This is why sub surface hydrants are a good idea.

  • @অবহেলিতছেলেরভালো

    so nice bro. অনেক সুন্দর হয়েছে

  • @southlafirephotography
    @southlafirephotography 4 роки тому +12

    Impressive video J! Love the thumbnail.

  • @skylerstearnes6370
    @skylerstearnes6370 3 роки тому +1

    Thank you for fixing it

  • @mattd8411
    @mattd8411 4 роки тому +5

    Yes definitely another advantage of having a dry barrel hydrants up here in the ole mtns of tn they would have broken off been replaced in a few hours without the waterlost. Wonder why they went to that first valve looks like they all should have a valve in front of the hydrant.

    • @shanegriffin8536
      @shanegriffin8536 2 роки тому +1

      That's the beauty of it lol. There's not always a foot valve at the hydrant. I'm in Chattanooga and run into that problem often. Either no foot valve or one nowhere near the front of the hydrant.

    • @tombo552001
      @tombo552001 2 роки тому

      But the wet barrel is so much easier to replace if it has breakaway bolts.

  • @smhenny
    @smhenny 3 роки тому +2

    Im so tired of web trolls giving videos a thumbs down. YOU try to follow LAFD on a radio and film for 45 minutes! Great video!

  • @jameshobby7953
    @jameshobby7953 Рік тому

    We have dry hydrants and where we are in the mountains, have about 175.0 PSI which would shoot water quite a bit higher than they have going here. Cool idea for clearing the valve box though!

  • @anthonyrobertson1787
    @anthonyrobertson1787 3 роки тому

    Thats One Way to Get your Shower 👩‍🚒👨‍🚒

  • @isaiahwilleford4618
    @isaiahwilleford4618 4 роки тому +5

    Also this is why I say we need auto cutoff valves in place in case a hydrant is damaged

    • @beastly7106
      @beastly7106 3 роки тому +1

      Especially on California where losing 2kgpm is a problem.

    • @can_hauler
      @can_hauler 3 роки тому

      This looks to be a "wet barrel" design, in it the valves are in the hydrant unlike a "dry barrel" design where the valves are below ground and doesn't geyser like this one when it gets damaged

    • @thetapper61
      @thetapper61 3 роки тому

      an auto cutoff could create water hammer and cause a main break on block. needs to be shut slowly to prevent that.

  • @FireRescue80
    @FireRescue80 4 роки тому +3

    That's not something you get to see everyday. Nice video.

  • @waynep343
    @waynep343 3 роки тому +2

    Decades ago the hydrant down the street was knocked off. My 17 year old sister took a bottle of shampoo and in her late 1970s bikini washed her hair. Only to be stopped by the CHP as she was in full view of the hollywood freeway and was causing a traffic jam. Juanita and middleberry streets FYI. it was a hot day.

  • @rp1645
    @rp1645 2 роки тому

    Just remember the warmer climate have these types of HYDRANT. Colder areas have a break away on ROD to base. The barrel is dry, it drains ( Hopefully) just depends on area of USA you live in.

  • @tv-zx1zw
    @tv-zx1zw 3 роки тому +2

    تحية لرجال الاطفاء الابطال👍👍👍

  • @bigtuna4037
    @bigtuna4037 4 роки тому +7

    Learned something new, I thought all hydrants were breakaway.

    • @josephbennett3482
      @josephbennett3482 4 роки тому +1

      No, fire Hydrants are open run systems that only have a valve in the top of the Hydrant so when it gets severed from the ground there's nothing to stop the water from coming out.

    • @royplumejr.8764
      @royplumejr.8764 4 роки тому +4

      In the northeast they are. The actual valve is below the frost line in the main.

    • @anthonythorp7291
      @anthonythorp7291 4 роки тому +3

      Wisconsin hydrants have a nut on top connected to a rod that runs about 6 ft deep to a valve. That valve supplies the water. The rod is designed to be the weakest link. If hydrant is hit, rod generally snaps. Sometimes it doesn't. For this an/or hydrant maintenance/replacement there's a valve in between the hydrant and water main.

    • @beastly7106
      @beastly7106 3 роки тому

      @@josephbennett3482 there are different types of hydrants not all are the same.

  • @vjsuhendra
    @vjsuhendra 3 роки тому

    God job

  • @DRFelGood
    @DRFelGood 4 роки тому +5

    Ah the water flow alarm 🚒🚒🚒🚒🚒🚒👍

  • @jelracer98
    @jelracer98 3 роки тому

    I bet the kids loved it and was yelling at the firefighters leave it alone lol

  • @fagiwarifwm1541
    @fagiwarifwm1541 2 роки тому

    It’s so beautiful

  • @tomwestley5332
    @tomwestley5332 4 роки тому +1

    They forgot the soap lol good job

  • @Mull_Shapaad
    @Mull_Shapaad 3 роки тому +1

    i could even smell that water just by watching the video

  • @alipescador2348
    @alipescador2348 3 роки тому +3

    Exelente labor los felicito Dios me los Bendiga 🙏

  • @ocsrc
    @ocsrc 3 роки тому +2

    Sure I can't use more than 50 gallons a day, but they can have a Bellagio fountain in the rich area of town ?

  • @arizonafirebuff1433
    @arizonafirebuff1433 4 роки тому +4

    Great footage! What camera are you using?

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому

      photos are taken on a Nikon D3400 DSLR, my scene vids are taken with an iPhone 11 mounted to that DSLR. thanks for watching!

    • @arizonafirebuff1433
      @arizonafirebuff1433 4 роки тому

      @@FB1ResponseVideos very cool! What about response vids?

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому

      for response vids, i use a Canon Vixia HF R50 (:

    • @arizonafirebuff1433
      @arizonafirebuff1433 4 роки тому

      @@FB1ResponseVideos ok cool. Just wondering cuz those vids are great quality!

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому

      i appreciate it!

  • @mikhaelbrilliant1248
    @mikhaelbrilliant1248 3 роки тому +1

    That Sweet great thanks

  • @gracie2424
    @gracie2424 4 роки тому +5

    A few weeks ago,there was a big water brake on the street and I was skateboarding and 5 seconds later after I passed the hole,water squirted everywhere luckily I didnt get wet but the firemen called some people to fix it,they didnt fix it because there was a emergency and they were leaving

  • @lebusraconte3040
    @lebusraconte3040 2 роки тому +1

    I just have a suggestion to all American Firefighters services. In France our firefighters have very efficient helmets. You should use the same protection helmets.🚒🍀🚒💫

  • @Wsportys
    @Wsportys 3 роки тому +1

    That was beautiful

  • @X-OR_
    @X-OR_ 3 роки тому

    Looks fun on a hot day !!

  • @bmsfx
    @bmsfx 3 роки тому

    If nothing else, the road is now clean..

  • @justiceagyeman1478
    @justiceagyeman1478 2 роки тому +1

    it really took them a long time to get that water to stop, and when i am 20+ then im gonna get a job for a fighterfire

  • @DSwirlman
    @DSwirlman 4 роки тому +2

    It's like watching Moe,Larry and Curly!

  • @overide_5532
    @overide_5532 4 роки тому +1

    Hey mom you wanted to go somewhere with a waterfall right?
    *brings out to the street

  • @omMohamed-dw5mn
    @omMohamed-dw5mn 3 роки тому +1

    احلى لايك حبيبتى الناس للناس حبيبتى ربنا يوفقك يارب العالمين اختى الجميله احسنتى النشر اختى الجميله

  • @fremountstsongsrich2453
    @fremountstsongsrich2453 4 роки тому +5

    I hope they re opened the 1st value they closed in case that was part of the main water line to the homes close by.

  • @TomTom-gn9mp
    @TomTom-gn9mp 3 роки тому +2

    Where'd all that water go? It doesn't seem to be flooding much.

    • @psirvent8
      @psirvent8 2 роки тому

      It all goes down the drain.

  • @vst9266
    @vst9266 3 роки тому +5

    When my wife's water broke was the same.

  • @ocsrc
    @ocsrc 3 роки тому +1

    That valve in the intersection is a hundred years old it's never going to turn without busting it right off and then you've got two problems
    Go get a 12-in pipe with bolt flanges and a valve and attach it to the base

  • @ocsrc
    @ocsrc 3 роки тому

    FYI:. There's a shut-off valve in front of every hydrant you don't need to turn off the valve in the intersection

  • @douglascrawford3896
    @douglascrawford3896 2 роки тому

    if i was a kid i would be playing in that ,until they showed up to turn it off !! someone is gonna get a bath turning that off ... lol

  • @MaxSmell210
    @MaxSmell210 3 роки тому +2

    2:40 just reaches down and turns off water.💪

  • @usuarioantofa2840
    @usuarioantofa2840 4 роки тому

    En Chile el servicio de Agua atiende estos casos,, por lo visto aya lo asen los bomberos buscando la válvula de pie como sele llama aka en Chile.. Excelente trabajo de los bomberos,, para cortar el agua del hidrante afectado muy bien,, saludos desde chile 🇨🇱 🇨🇱 🇨🇱 🚒🚒🚒

  • @charlespaul9787
    @charlespaul9787 3 роки тому

    Selute to fire force department. 🙏🙏🙏🐅🐅🙏

  • @KevinSmith-bs9iw
    @KevinSmith-bs9iw 4 роки тому +4

    It's too bad the city hasn't figured out to keep the valves in the street, with a minimum of one full length piece of pipe between hydrant and shut-off valve.

  • @waynep343
    @waynep343 3 роки тому

    It took me years of letter writing to get the hydrant on Wilton place at 5th st moved to avoid it being knocked off constantly and unusable. station 29 can you hear me. I finally cornered the 29 captain one day and pointed it out. I wonder if the power box on Wilton and wilshire is still wrapped in a yellow fiberglass blanket as the panel over the infused power cables is still missing after 10 years.

  • @haroldmedocland4635
    @haroldmedocland4635 3 роки тому

    I installed BAYARD SAPHIR CHOC hydrants. They can be bumped with a car and no leak, they have breakable bolts and the tap don't get open.

    • @psirvent8
      @psirvent8 2 роки тому

      C'est un gros avantage par rapport aux poteaux américains, et je doute qu'ils aient des Bayards là-bas en revanche.

  • @josephastier7421
    @josephastier7421 3 роки тому +1

    When he was hitting the tool with a rock I was waiting for another geyser to come blowing out of the hole they were working in.

  • @nothingtoxic1879
    @nothingtoxic1879 4 роки тому +2

    This video reminds me of everything about her

  • @ikhlaqhussain9601
    @ikhlaqhussain9601 3 роки тому

    Really awesome

  • @214jef
    @214jef 4 роки тому +33

    5 million gallons of water pissed away down the drain because of shitty, antiquated valves and no inspections.

    • @timothyhnida8965
      @timothyhnida8965 4 роки тому +3

      My question is why isn't there a break off valve so this doesn't happen.

    • @214jef
      @214jef 4 роки тому +6

      @@timothyhnida8965 you would think that by the year 2020 there would be advancement in fire plug technology.

    • @nicholasbachelder6532
      @nicholasbachelder6532 4 роки тому +6

      The fun of having wet barrel hydrants instead of dry barrel

    • @mackflickerson6722
      @mackflickerson6722 4 роки тому

      @@timothyhnida8965 most of SoCal uses wet-barrel hydrants.

    • @dennisandry1632
      @dennisandry1632 4 роки тому +1

      Can any of that be captured to use for any reason, seems like a collection system can be invented to do that ? Even a transfer pump to another vehicle of some sort. Think of all these wild fires nowadays and how Helicopters r used sometimes u take water from nearby swimming pools.

  • @garykcs5532
    @garykcs5532 3 роки тому +2

    Working for L A County fd, I knew when they went to the first valve it was way to far away. Come on man

  • @BigDuke-md8ec
    @BigDuke-md8ec 4 місяці тому

    There is a similar video of the exact same thing occurring in NYC. This video is the perfect example of the drama that comes with working in LA . NYC used one engine company, essentially one guy most of the time working the valve , finished closing valve with a second FF . LA has multiple FF’s , a hand-line stretched and what sounds like news helicopters hovering overhead and to top it off the videographer who was on scene before FD’s arrival ….. doesn’t have footage of the valve finally be shut ! 🤦🏻‍♂️

  • @evanurso7739
    @evanurso7739 4 роки тому +1

    This is a pumpers paradise

  • @TheJimmy144
    @TheJimmy144 4 роки тому +1

    Serious question: why do they even bother installing wet barrel hydrants? There's no harm in just putting in dry barrel hydrants, which would prevent this from ever being an issue. Anyone know why they don't?

    • @BLACKMONGOOSE13
      @BLACKMONGOOSE13 4 роки тому +1

      Probably cost. Wet hydrants are much less per hydrant. That's what they tell us in my city.

  • @ЗауреСуюнова-е2ь
    @ЗауреСуюнова-е2ь 2 роки тому

    Хорошо что не горячая вода...обашлось.Красивый был фонтанчик..

  • @andyschmiemann7794
    @andyschmiemann7794 3 роки тому

    Super Video 👨🏻‍🚒

  • @ok-iu3vf
    @ok-iu3vf 3 роки тому +1

    Exelente video

  • @rayarsenault4774
    @rayarsenault4774 4 роки тому +13

    6:24 oops, wrong valve.
    This is the benefit of dry-barrel hydrants, even in no-freeze areas....

    • @jackgibsxxx0750
      @jackgibsxxx0750 4 роки тому

      Yes. And I would think you could still have a valve for each cap even on a dry- barrel. Every time you replace one upgrade it.

    • @IDieForPie
      @IDieForPie 4 роки тому

      Probably trying to close one side of the loop to have a little less pressure

  • @kp5106
    @kp5106 3 роки тому

    Good job fellas

  • @OwneyMadden430
    @OwneyMadden430 4 роки тому

    No public works / Water department type of agency available out in LA ? I know the FD i work we wouldn’t attempt that we would block off the street & wait for Water commission guys to come lol , our problem in the ghetto where we work in the summer the kids open the hydrants to play in the water on super hot days , so we go all around the city shutting them off all day long , then 20 min later were back & there open again 😂.. LAFD I give you guys big time respect , that’s dedication boys 🤙🏽

    • @mackflickerson6722
      @mackflickerson6722 4 роки тому

      In Los Angeles, the fire department responds emergently to shut off sheared hydrants because the water supply is so fragile. Understand that the LA Basin is basically a desert for many months out of the year. Domestic water is brought in to the city's reservoirs by aquaducts, often from hundreds of miles away, and that supply is ultimately very limited. A 2,000gpm "leak" in the system can be extremely detrimental not only to available water for fire fighting, but also for potable water supply. The less time such a leak is allowed to go, the better for everyone.

    • @DrLumpyDMus
      @DrLumpyDMus 4 роки тому

      All that was very well described in the very first pinned post. LA is not your city. They do things a little differently.

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому

      Mack Flickerson I understand that about the water shortages and the desert climate . More than ever now the entire state has been taking a beating with wildfires from the multi year Drought that they are in the middle of ... The difference is in NYC area where I’m a FF & any other area that is prone to prolonged freezing conditions we use Dry Barrel hydrants that when sheered off do not create a Geyser of water . In fact not a drop comes out if a car knocks a dry barrel over . Maybe LA & other city’s in Southern Cali should look into installing them to avoid this kind of situation .

    • @OwneyMadden430
      @OwneyMadden430 4 роки тому

      Craig Lumpy Lemke ok Lemmy we are splitting hairs at this point !! I was responding to other people beside you at some points , can we please stop talking about this 🥴🤯

    • @DrLumpyDMus
      @DrLumpyDMus 4 роки тому

      @@OwneyMadden430 Mr Madden, you're welcome to respond or not, to "stop talking" or not. I will do the same. Kind of like fire hydrants. One area pays for it one way, another area pays for it another way. I'm pretty sure it's ok with most LA firemen if NY does their hydrants the way NY wants to do their hydrants.

  • @rogerbrewer7770
    @rogerbrewer7770 4 роки тому

    If the would have spec and purchased mid central northern hydrants this would never lose a drop because when the top portion of the hydrant gets sheared off for what ever reason the valve would shut under pressure and relatively no loss of water. Poor choice in style of hydrants.

  • @nigelwilliams4800
    @nigelwilliams4800 3 роки тому

    Wow must be a better safer system sure? Or well good job guys give the place a good clean free shower 🚿

  • @tejtrambharatt5182
    @tejtrambharatt5182 3 роки тому +3

    Unbelievable. They couldn’t have done a better job for an easier access to shut off the water that was just torture for the fire fighters.

  • @saravanansriram2882
    @saravanansriram2882 2 роки тому

    Nice to see this.

  • @cursdesmondes2789
    @cursdesmondes2789 8 місяців тому

    En France il y a 12 bar de pression pour l’incendie et le diamètre sous terre est de 80/90 cm

  • @mehrindipa3573
    @mehrindipa3573 3 роки тому

    Wow fantastic....v nyc..

  • @alistairyoung9831
    @alistairyoung9831 4 роки тому

    Hello my name is Alistair Young and I am a teacher from Bradford in England. I am creating an educational video for our young people to teach them about the importance of respecting and recognising the amazing sacrifices of our emergency services across the world. Please can I use some of this footage in my video with appropriate crediting? Thanks so much.

    • @FB1ResponseVideos
      @FB1ResponseVideos  4 роки тому +1

      hey there, feel free to use the footage. thanks for asking! (this goes for the comments on the other vids as well 👍🏾)

    • @alistairyoung9831
      @alistairyoung9831 4 роки тому

      @@FB1ResponseVideos thanks so much. I will credit fully your channel for the footage.

    • @alistairyoung9831
      @alistairyoung9831 4 роки тому

      @@FB1ResponseVideos thanks so much. I will credit fully your channel for the footage.

  • @stevebrewer1720
    @stevebrewer1720 3 роки тому +1

    Good job firemen!