    @SnoopytheAce Рік тому +9

    THIS IS FOR A CANADIAN AUDIENCE: the outlet shown for a range in the US needs to be on 50 amp circuit, and as such needs to be wired with 6 gauge wire and not 8 gauge. There are subtle differences, make sure you are referencing the NEC appropriate for your area.

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому +2

      Oh that is interesting. Yes, Canada was always 40A and #8 AWG Copper, and the plug had all slots vertical. Dry is 30A breaker, #10 AWG Copper, and one of the plugs has an L (for laundry 😎)

    • @Zippylandenk
      @Zippylandenk 2 місяці тому

      Thank you for informing me

  • @SauloRM
    @SauloRM 8 місяців тому +1

    Your videos are amazing!!!!

    • @BecomingAnElectrician
      @BecomingAnElectrician  8 місяців тому

      Thank-you. I'm glad you found it useful. If you want to learn more about becoming an electrician, I also run the website, too: becoming-an-electrician.com/free/

  • @seonah1994
    @seonah1994 Місяць тому

    Hi! Viewer from Europe here! How do we choose the right boxes for concrete walls? I mistakenly bought a dry lining box and came to understand its the wrong one. Thanks!

    • @BecomingAnElectrician
      @BecomingAnElectrician  Місяць тому

      Hey! If you are an electrician, your code book should have a section in the back tables sharing that kind of boxes are allowed. If it doesn't show there, then if you go onto the electrical box company's website, they will have a section for different types of boxes. If you are unsure, look at the SPECIFICATION SHEET, which will tell you what the equipment is usable for.
      If you're just a do-it-yourself, then ask your local hardware store about the task you're trying to accomplish.. they should guide you through what hardware & equipment you'll need!
      becoming-an-electrician.com/

  • @nathanield.4527
    @nathanield.4527 Рік тому +1

    What do you recommend for a junction box in the attic? Is it best to mount the box above the insulation like on a rafter or is ur ok to cover it with insulation? Is there such a thing as an IC rated junction box?

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому +1

      Hey, good questions. I cannot give advice here, I'd talk to your local electrical inspector.
      Personally, I'd mount the junction box above like on a rafter because you can easily see it (not buried), and it won't be in the insulation. A metal 4x4 with a cover I'd use. (Again, talk to your local electrical inspector for the proper installation in your area).

  • @SirensOfOregon
    @SirensOfOregon Місяць тому

    Hey there, which box would be the best for fire alarms, specifically the simplex 4903, I bought one, but the speaker does not fit in. Thanks -siren and fire alarm enthusiast here

    • @BecomingAnElectrician
      @BecomingAnElectrician  Місяць тому

      I'm just guessing from the pictures I saw online.. It looks like a single gang box would do? I couldn't find direct information, and didn't look too deep into it, sorry.. I also saw one picture that included it's own box you'd install in rough-in? What kind of electrical box did you purchase already? And what kind of situation are you in?
      becoming-an-electrician.com/

  • @chris23384
    @chris23384 8 місяців тому

    Thanks for the video! On the easy box example @16 Minutes, the wires go into the top of the box and clamp down. Question: which grommet and size would you use to protect the wire. thank you

    • @BecomingAnElectrician
      @BecomingAnElectrician  8 місяців тому +1

      For the EZ Box, it should already have a clamp built-in. Remove the wire jacket, pop the EZ Box tab, insert the wire, and tighten down the wire clamp!
      becoming-an-electrician.com/

    • @chris23384
      @chris23384 8 місяців тому

      @@BecomingAnElectrician Thanks for responding. The knockout on the top must be removed to insert the wire. this leaves a sharp edge. Do you use a rubber grommet or other option to protect the wire. or do you just insert the wire and tighten down the clamp. thank you

    • @BecomingAnElectrician
      @BecomingAnElectrician  8 місяців тому +1

      ​@@chris23384 First, the cable has different components to it. It has the outer sheath, which is what you are stripping off. Then inside are the conductors, that have their own insulation to identify what wire is which and prevent short circuit. Simply strip the outer sheath (JACKET), then insert the cable into the EZ Box so that the JACKET goes under the clamp. If it's super sharp, you can try to file the EZ box hole if you're really sketched out before putting the wire in and tightening down. But generally, you just strip the wire jacket, pop the EZ box knockout, put the wire in, and tighten it down on the jacket (not the individual conductors, if that makes sense).

  • @Markdoubts
    @Markdoubts Рік тому

    I am installing 15 amp receptacles in my barn. All exterior mounted to 3/4 plywood in conduit. I am running 10/2 because it is over 100ft. My questions - can I fit a gfci, receptacle and feed out to the side of the barn in an extra deep 4x4 box? Thank you very much,!

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Hey! Contact your local electrical inspector, as rules are different where you live!

  • @farmerrick9660
    @farmerrick9660 2 місяці тому

    Great videos, i was looking for help, im doing electrical in an old trailer that has 2x2 wood framing, ive got dimmers and usb outlets to install and theres not much room for them , any ideas or tricks?, the boxes i have are shallow 1 1/2 and the walls well be covered with 1/2 cedar , so 2 inches max, the electrical outlets with the usbs are about 2" and same for my dimmer switch

    • @BecomingAnElectrician
      @BecomingAnElectrician  2 місяці тому +1

      I'm not sure of an answer... my guess is you will have to try and find slim switches, or built out the wall 👎

  • @fernandopureza5058
    @fernandopureza5058 Рік тому

    What device box do you use for interior masonry wall? Does Iberville make a 1-1/2 deep masonry box for flush mount?

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Hey reach out to your local inspector, they'll tell you how to do it properly!

  • @rul1175
    @rul1175 Рік тому

    What is the brabd and code for the residencial plastic single cover with the screw o the back?. I cant find them.Thank you!

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Code rules are different for different continents.. reach out to a local electrical inspector!

  • @mikecorkey5511
    @mikecorkey5511 Рік тому

    What do you mean about bonding in the plastic box

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Could you clarify your question further, and what you're confused about? - We always need to bond a box. Bonding is a word that gets confused with "grounding". Grounding only happens at one point of a home's electrical system. Bonding then ensures no equipment body can be energized.. if it happens, it will trip the breaker!

  • @surferdude642
    @surferdude642 5 місяців тому

    I like the Canadian plastic boxes, the look a lot better than the cheap crappy ones in the US.

    • @BecomingAnElectrician
      @BecomingAnElectrician  5 місяців тому

      Yeah they are called NuTek boxes. They were nice to work in when splicing wires, too!
      becoming-an-electrician.com/

  • @vince6829
    @vince6829 Рік тому

    Thank you for sharing your knowledge.
    I do have a question regarding pancake boxes. Can they be used outdoors (e.g. for a porch light) so long as they are recessed into the wall and not surface mounted? I know that they are not weatherproof.

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому +2

      Yes I think you can.. they are most often used if you need to get a light perfectly center, but the stud/joist is in the way. You can mount the pancake box center, and still allow a wire to get into the pancake box. Remember, only one wire is allowed in a pancake box! (Always double check with electrical inspector if you're allowed using outdoors.. rules change way too often in the electrical industry.. hard to keep up).

    • @vince6829
      @vince6829 Рік тому

      Thank you for the prompt reply. It’s greatly appreciated.

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому +1

      @@vince6829 You are very welcome! Thanks for the comment, and I hope the videos continue to help you.

  • @talalalrahbi9430
    @talalalrahbi9430 6 місяців тому

    Hi sir,your explanation is amazing and clear ,could you send me book??

    • @BecomingAnElectrician
      @BecomingAnElectrician  6 місяців тому

      Thanks - You can download it here with email sign-up:
      becoming-an-electrician.com/optin/5-tips-apprentice-electrician-book/

  • @HamiltonMechanical
    @HamiltonMechanical Рік тому

    what the heck area are you in? I've never seen some of those plastic boxes you have! pretty neat :) Usually get the blue carlon ones here but 2021-2022 we were having a time getting boxes in my area, local suppliers started getting in these generic black boxes that I had not seen before, and when we were really desperate, we'd grab fiberglass. But never seen some of these gray plastic boxes like you have there here in east tennessee :) pretty cool!

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      I'm from Canada, these boxes shown are the ones most commonly used where I'd work! Thanks for checking out the video!

    • @rul1175
      @rul1175 Рік тому

      What is the brand, do u guys do 120v??

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      @@rul1175 These are Iberville I think. 120V for basic plugs, 240V for ovens / dryers (it's 208V in 3-phase systems here).

  • @kishankhavas1993
    @kishankhavas1993 Рік тому

    Thank you 😊🙏

  • @rajasekaran8420
    @rajasekaran8420 4 місяці тому

    Great video🎥🎥🎥 sir

    • @BecomingAnElectrician
      @BecomingAnElectrician  4 місяці тому

      Thank-you! - Many more electrician videos on the website: becoming-an-electrician.com/

  • @JackElectrician
    @JackElectrician 2 роки тому

    Awesome Video

  • @SnoopytheAce
    @SnoopytheAce Рік тому

    Good content!

  • @DitNg516
    @DitNg516 Рік тому

    Good video

  • @skymhook
    @skymhook 2 роки тому

    What is the difference between a "3/0" box, a "4/0" box, and a "3/0 - 4/0" box?

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Hey, I've never heard of this term before in all my years.. however, I'm located in Canada.
      After a quick search, it seems like they are Octagon boxes.
      As electricians, we'd just call them Shallow Octagons or Deep Octagons.
      Shallows allow less wires, Deeps allow more wires, as well as need more room to install!

  • @wasteelectricalwork886
    @wasteelectricalwork886 2 роки тому

    Very good 👍

    • @BecomingAnElectrician
      @BecomingAnElectrician  2 роки тому

      Hey thanks! Appreciate your comment.. more videos coming up soon 🙂

    • @rickyperkins232
      @rickyperkins232 2 роки тому

      @@BecomingAnElectrician it seems like commercial Buildings never are spec for plastic boxes?

    • @BecomingAnElectrician
      @BecomingAnElectrician  2 роки тому +1

      @@rickyperkins232 I've never really seen a jobsite spec specific boxes, but types of wires.. which will then decide the types of boxes you use. Also, using metal boxes on metal studs allows you to keep bonding continuity, plus you can use EMT pipe, BX (Armored Cable), and they are usually just more flexible in terms of what you can connect into them..
      I really prefer the metal 4x4 boxes that have the metal strap on them (compared to 4x4 metal boxes without stud wrap!)
      I really do like working in plastic boxes in residential.. easier on the hands.. don't get cut fingers as easily 😁

    • @rickyperkins232
      @rickyperkins232 2 роки тому +1

      @@BecomingAnElectrician understood

  • @tecnisdaimondm.g9321
    @tecnisdaimondm.g9321 Рік тому

    Excelente

    • @BecomingAnElectrician
      @BecomingAnElectrician  Рік тому

      Hey, thanks! Hope you found the information you were looking for about different types of electrical boxes!
      becoming-an-electrician.com/different-types-of-residential-electrical-boxes/

  • @robertkat
    @robertkat 9 місяців тому

    You better go to college for 2 years , it takes that long to graduate as an electrician.

    • @BecomingAnElectrician
      @BecomingAnElectrician  9 місяців тому

      Hey, here's a guide for how to become an electrician in Canada:
      becoming-an-electrician.com/how-to-become-an-apprentice-electrician/
      It takes 4 different levels of schooling, each are 3 months of training. You also need your hours. So it takes about 4 years on average to become a certified Journeyman with ticket (in Canada).

  • @jamaljamal4900
    @jamaljamal4900 2 роки тому

    🌹🌹

    • @BecomingAnElectrician
      @BecomingAnElectrician  2 роки тому +1

      Thanks again, I hope you enjoy my FREE Electrical Book from my website there!:
      becoming-an-electrician.com/
      Reach out any time!

  • @ChristopherJames4
    @ChristopherJames4 2 місяці тому

    Please learn All the proper names and terms for all of these products before you try to teach others what they are. Lol.