Sizing Pull and Junction Boxes made Easy

Поділитися
Вставка
  • Опубліковано 9 лют 2025

КОМЕНТАРІ • 43

  • @nikospido3000
    @nikospido3000 Рік тому +6

    I really appreciate this video, I was having trouble understanding it by reading it from my text book since I'm in trade school, but this video spelled it out for me. Tank you so so much

  • @christianeacker1111
    @christianeacker1111 5 місяців тому +2

    What a dime of an educational video

  • @AN-vs5pb
    @AN-vs5pb Рік тому

    Thank you, this is so helpful. It's a lot essier to understand when seeing it.

  • @agustinfranco5139
    @agustinfranco5139 2 місяці тому +1

    Excellent video sir

  • @Jesus-f2f1p
    @Jesus-f2f1p Місяць тому

    Like your videos, hope you do more thanks

  • @michaeldonnelly2977
    @michaeldonnelly2977 Рік тому +1

    Very informative. Thank you!

  • @koarivera9151
    @koarivera9151 2 роки тому

    Great explanation and pics

  • @jakegodfrey9490
    @jakegodfrey9490 2 роки тому +1

    Great video! Extremely helpful!

  • @garyschlosser9714
    @garyschlosser9714 2 роки тому

    Great explanation of the code very helpful

  • @richrosario5741
    @richrosario5741 2 роки тому +1

    Great explanation.

  • @JesusCruz-wt2zp
    @JesusCruz-wt2zp 3 роки тому +1

    Nice video... keep doing more

  • @nam.321
    @nam.321 4 роки тому

    Great video. Very Straight forward.

  • @gilbertopatino2616
    @gilbertopatino2616 5 років тому +2

    Thank you very much for great video 👍

  • @ricardofuentes2153
    @ricardofuentes2153 6 днів тому

    una pregunta, en Angle pulll, cuando dices que seria 12" minimum between raceways, si tomamos desde una esquina de la caja hacia bajo 6" y la otra de arriba esquina 6", ahi se completa las 12", o sea que una caja de 14" va quedar bien?

  • @jesuspaz7446
    @jesuspaz7446 11 місяців тому +1

    AWSOME VIDEO

    • @AccessToPower
      @AccessToPower  10 місяців тому

      Thank you for the comment! I appreciate your feedback.

  • @vics9830
    @vics9830 3 роки тому +2

    Cool video what a great explanation thanks would of been great if you mentioned the calculations for over 1000V sheathed and unsheathed conductors in this video as well not just 1000volts or less calculations thanks buddy.

  • @rockbottomi
    @rockbottomi 9 місяців тому

    so in the angle pull we still had to size up the box to get 12 inches between raceway?

  • @paulramirez1774
    @paulramirez1774 9 місяців тому

    More videos please!

  • @looneygoon1543
    @looneygoon1543 5 місяців тому

    Are these good measurements for 1/0 wire?

  • @christophern.9234
    @christophern.9234 4 місяці тому

    Isn't this for conduit and boxes containing 4awg wire and larger only?

  • @anthonypicozzi4414
    @anthonypicozzi4414 Рік тому

    How much support do you need for a pullbox like that? Do you need four corners or is it by the weight?

  • @mazmaz5136
    @mazmaz5136 10 місяців тому

    SAME AS CEC CANAD CODE BOOK NICE

  • @euginereynanmorastil1518
    @euginereynanmorastil1518 Місяць тому

    Where is the 1+1+1" came from?

  • @kalusugan6239
    @kalusugan6239 4 роки тому +3

    How to determine the width and height of pullbox?

  • @davcot3675
    @davcot3675 5 років тому +1

    Good explanation

  • @rafaeljonesjr9029
    @rafaeljonesjr9029 3 роки тому

    What about a straight pull with 2 conduit in an out of either side. How you figure width of the box? An depth? I get the length

  • @Fc9ers
    @Fc9ers 4 роки тому

    Mike Holt figure 314-50 says spliced conductors do have to have no less than six times the trades size of the largest raceway, plus the sum of the trade sizes of the remaining raceways on the same wall or row,

    • @Ed-uu9eo
      @Ed-uu9eo 4 роки тому

      Yes. That's sizing the distance to the opposite wall.

  • @2424jhg
    @2424jhg 4 роки тому

    Do you have a video for branch

  • @enerji4330
    @enerji4330 3 роки тому

    Any infor on depth?

  • @giannimartinez5015
    @giannimartinez5015 4 роки тому

    what about the depth of the box? we got length and width, what about depth?

  • @Shingho2
    @Shingho2 4 роки тому

    What if I'm not pulling 4AWG or larger then non of this is required? Read 314.28A

    • @AccessToPower
      @AccessToPower  4 роки тому

      Yes you are correct. This is for wire that is #4 or Larger. Thanks for the comment.

  • @kevinkuang9429
    @kevinkuang9429 5 років тому

    What is the depth of the box?

  • @jeredj9080
    @jeredj9080 5 років тому +1

    what's the rule if they were spliced?

    • @AccessToPower
      @AccessToPower  5 років тому +1

      Hey Jered. The rule, if the wires are spliced, is found in 314.28(A)(2) and requires 6 times the largest conduit size in a row, plus the diameter of all the other conduits in that same row on one side of the box. each row is calculated separately and the row with the largest dimension is required for calculating the size of the box.

  • @Muddypaws589
    @Muddypaws589 Рік тому +1

    It's largest Conduit. Not largest conductor.

  • @TexasState-s8k
    @TexasState-s8k Рік тому

    Second step size and get me the personal utility belt licenses list of items i need to do computer it social study and legally open street poles and the god damn JUNCTION BOX WITH THE WORDS DANGER HIGH VOLTAGE

  • @TheDonkeysVoice
    @TheDonkeysVoice 2 роки тому +2

    6 X The Largest Conductor ? Or 6 X The Largest Pipe ? In think you made a mistake because you did not calculate Conductor sizes . So you misspoke. I’m just point it out because I’m a new studying apprentice and it didn’t make sense , so I had to look into it again . I listened again and realized , I doesn’t make sense because you just misspoke a word .

  • @ivglife9831
    @ivglife9831 3 роки тому

    Bro you, you are incorrect