Your video is so good, and I was moved by your professional knowledge. We are a Chinese supplier specializing in the production of frequency converters and soft start for 12 years. I hope we can have some cooperation in the future.
So if I'm understanding this correctly, there is no neutral in the circuit, so the two power leads come from the double pole breaker, red into one pole and the black into the other pole? So I'd be pulling three wires, a ground, and two power leads and no neutral?
In video you connect red and black to L1 and L2 witch are hot. Each wire provides 120v. You connect green wire as ground. Where does the neutral white wire connect ? I'm wiring a TECO E510 VFD. 240 volts single phase input power to power a 240 volt 3 phase motor.
I just added a VFD to an old CNC I have. Its your Mitsubishi. Thanks for showing how to get the main power cover off. Now my problem is this. The 4 lead wire that came off the spindle motor to the FWD rev relay only had the 3 power wires going between motor and controller. The ground lead from the motor went straight to the grounding area of the enclosure. Now my wire is not long enough to get to the VFD in the cabinet. Is it good enough If I just run a grnd from the VFD to the grounding area of the cabinet? Should I just say, start from the beginning and get a dedicated VFD to motor wire? Wire would have to be about 8' long.
My pump is single phase (I guess, as it doesn't say anything else) with a standard plug... It has a pressure tank attached... Hoping just to plug it into a VFD controller to do what a VFD does... Is there a controller that will do that?
in an application with constantly start stop of three phase motor what is the better way so motor doesnt hot to coonect the inverter with triangle or star
Hello Steve thank u for sharing information wht I want to know is the sattings of the frequency to run motor or water pump connections hve been easy thanks again.
Hi can you please help i have a cross cut saw and need to put in a two way switch so that i can have it running continuously or on the hand button stop&start also i need to put in an emergency stop
Hi. This is Alan from MICNO. We are a professional VFD, AC drives, Frequency Converter, Solar Pump Inverter manufacturer in China. We can supply you with very favorable price. If you are interested, you could send me an email at liupengfei@micno.com.cn / Skype: alanbusiness91 / WhatsApp: +86 15112589350. Hope to help you to some extent.
I wasn't sure if a vfd changed the output frequency or the rotation frequency I've since learned a stepping motor controler controls rotation points I can't see a 3 pole stepping motor out there thanks for help much appreciated
Thanks for sharing the video. Nice explanation on single & 3 phase wiring. I have subscribed your channel. Where can I find the video on programming the VFD?
Do you have a tutorial on how to connect a single phase motor to a single phase vfd :)? I've seen people do it and I need to do it but I would like to know how to :).
By grounding via cable to a ground star bar, does having the VFD case grounded to the control panel backer not cause a ground loop by having two grounds come from the drive?
Please i want to buy single phase 2.2 kw vfd, will this run any 3 phase more below 2.2 kw, will some one advice, thanks great video, thanks for loading
Wondarful sar I have one 5hp solar pump in myagriculture field But some problams in burn thisvfd d700 So no many iam poor farmar. Present in not working thisvfd .
You don’t specify for what country? Here in Oz - we have 4 core + Earth wires:- L1 Red L2 White L3 Blue Neutral Black Earth Green with yellow stripe! And it’s 440 volt 3 phase. L1 L2 & L3 are interchangeable to reverse parity on 3 phase motor & get it to spin correct direction.
Could you tell us about the problem of my vfd,we have 3phase vfd and i try to wiring installation but still 000 display in indicator when i start push button, Actually i lost manual for this vfd can you help us,. thanks
Lanclot, a VFD is used to control electric motors, they do not power the motors or transformers for that matter. Feel free to check out our video "what is a VFD"
If you are trying to program Mitsubishi VFDs, check our video library and you will find other videos showing some basic programming. Every brand of VFD has different terminology, so we can't answer what F, H, A means unfortunately. For any programming specific for your machine, you will have to consult your manual for the parameters or find a local electrician who has experience with VFDs.
Hi VFD Team, I'm from Germany and I'm trying to wire my singlephase VFD to a 3phase Motor. Here in Germany we have one Hot wire one neutral and eart. My VFD doesn't say anything about the neutral ... Do you have any Idea how to wire an VFD with only one hotwire ?
The part I am getting tripped up on is how to wire in a switch to the line side going into the vfd so I do not have to leave it on constantly. From what I can gather I will need a DPST switch rated for the correct amperage but I can not seem to find any 2 articles or opinions that say this is the correct way to configure the switch. Some say that a switch will always burn out others say they have had a switch on theirs for ages. My manual does not list any control ports for a power switch and i I understand it correctly it goes as far as saying that a switch should not be used to control the run/stop of the drive. I take that to mean that you should not use a switch to put the unit under a load not just powering the unit on but I am admittedly getting a little cautious. Any guidance would be appreciated.
Shahbaz, this is an AC VFD pairing with AC motors. If you have a DC VFD, you will need a DC motor. The wiring might be different since the VFD is manufactured by a different company. Emerson makes great DC VFDs.
Hi, I am a mechanical engineering student working designing a screw conveyor as my senior project. I have a Baldor 1.5 hp brake motor. I need it to power a conveyor that will have a speed of 20-40rpm. As of now, I have a gear box with a turn-down of 20. Additional to it, I am thinking to use a VFD to control the speed. At this point, I need to start selecting a starter and VFD and need some help with that.
Hi Sofia, A VFD acts as a starter, so you shouldn't need one if you have a VFD. What is your input power voltage and phase? What is the voltage and FLA of your 3 phase 1.5HP motor?
Thank you for this very helpfull video, please help me program a VFD for PID control and explain all the parameter in detail . Hope to see your new videos soon :) :)
hello friend, I am working in a solar panels company my manager asking a question to me.what happening the +ve and -ve terminals are changed into the drive is burning or working.
You'd be most likely able to drive any VFD with arduino - it's controls are like analog input for speed control and digital inputs for rotation direction, emergency stop etc.
I have a delta 3.7kw VFD. I am using 230V BRWG (black, red, white, green) from my panel to L1,2,3,G respectively. I am using the same for T1,2,3 G. I am getting 220V to ground from each line into the magnetic start panel. I have selected the H4 220V terminal of the transformer that links to the magnetic switch (previously it was on 460V H3). When I hit the start switch I get a rapid clicking of the magnetic switch and no motor engagement. I called delta and the tech told me one of the three line legs coming in from the VFD is a "fake leg" and that must be connected to T3 or L3 depending on which end of the wire you wish to view. How do I identify this so called fake leg? I see no info in the manual about this. I am using this VFD to drive a 5hp motor for a delta unisaw (34-806) which I wired from delta to wye. I am not used to needing help for such things, but I am at a loss on this. Has anyone encountered this before?
Rollin, We need more information in order to answer your question. (1) We are not sure what you were referring to when you said "fake leg"? (2) What exactly is the magnetic switch that you mentioned? What does it do? Where is it located in the arrangement of the electrical components? (3) Where is the transformer getting its primary power? (4) Do you have a contactor after the VFD? If you are trying to close the contactor after the VFD is turned on, it will not work. Let us know. Thanks.
230v and 240v is the same thing. single phase power can be either 120v (hot and a neutral) or 2 hots as "nominal" 230-240volt. same thing like, potatoe potatoo .. lol
Your video is so good, and I was moved by your professional knowledge. We are a Chinese supplier specializing in the production of frequency converters and soft start for 12 years. I hope we can have some cooperation in the future.
So if I'm understanding this correctly, there is no neutral in the circuit, so the two power leads come from the double pole breaker, red into one pole and the black into the other pole? So I'd be pulling three wires, a ground, and two power leads and no neutral?
In video you connect red and black to L1 and L2 witch are hot. Each wire provides 120v. You connect green wire as ground. Where does the neutral white wire connect ? I'm wiring a TECO E510 VFD. 240 volts single phase input power to power a 240 volt 3 phase motor.
Do uvw Have a neutral? And if so what color is neutral?
I just added a VFD to an old CNC I have. Its your Mitsubishi. Thanks for showing how to get the main power cover off. Now my problem is this. The 4 lead wire that came off the spindle motor to the FWD rev relay only had the 3 power wires going between motor and controller. The ground lead from the motor went straight to the grounding area of the enclosure. Now my wire is not long enough to get to the VFD in the cabinet. Is it good enough If I just run a grnd from the VFD to the grounding area of the cabinet? Should I just say, start from the beginning and get a dedicated VFD to motor wire? Wire would have to be about 8' long.
My pump is single phase (I guess, as it doesn't say anything else) with a standard plug... It has a pressure tank attached... Hoping just to plug it into a VFD controller to do what a VFD does... Is there a controller that will do that?
in an application with constantly start stop of three phase motor what is the better way so motor doesnt hot to coonect the inverter with triangle or star
is there a certain type of VFD wire that we should get?
Can I use VFD to distribute power in homes ?
Nice video Sir. But you didn't tell us main things that was parameter setting and control wiring? .Thanks
Great basic wiring video. Single phase to 3 phased wiring explained. Thanks.
Can a 3 phase to 3 phase vfd be used as a single phase to 3
Single phase from my circuit breaker box. Do I use a 220v breaker?
Hello Steve thank u for sharing information wht I want to know is the sattings of the frequency to run motor or water pump connections hve been easy thanks again.
Will a disconnect after the vfd but before the motor affect the performance of the vfd .
Hi can you please help i have a cross cut saw and need to put in a two way switch so that i can have it running continuously or on the hand button stop&start also i need to put in an emergency stop
Can Danfoss FC51 drive be powered with SOLAR input to getsingle phase 220v AC current
Good video. So these little VFD's can replace my big and heavy single phase to 3 phase converter while giving me speed control??
Hi. This is Alan from MICNO. We are a professional VFD, AC drives, Frequency Converter, Solar Pump Inverter manufacturer in China. We can supply you with very favorable price. If you are interested, you could send me an email at liupengfei@micno.com.cn / Skype: alanbusiness91 / WhatsApp: +86 15112589350. Hope to help you to some extent.
Question instead of connecting it with 480v how do I connect it using 230 v. what terminal do I use? Or is it not possible?
Its great job you done thanks for that can you use single phase vfd to control or power three phase motor.thanks
Vfd create harmonics in the line. Can you deal with that
How do I program 2.2kw inverter on a 3 phase connections
What about the brake resistor? It has three wires but no label. Both are Galt units.
I wasn't sure if a vfd changed the output frequency or the rotation frequency I've since learned a stepping motor controler controls rotation points I can't see a 3 pole stepping motor out there thanks for help much appreciated
Lanclot, a VFD changes both the Hz and RPM. You should check out that video I told you about.
Thanks .. sir... how to fixe vfd out put indicate lights . Please sir.. tell me
He says you don't have to use wire ferrules, but with multi stranded wires going into a screw terminal you should always use wire ferrules.
Can you wire a single phase to 3 phase vfd to only output 220v?
Please make a video on Servo drive
How i can connect it to mach3 breakout board
Thanks for sharing the video. Nice explanation on single & 3 phase wiring. I have subscribed your channel. Where can I find the video on programming the VFD?
I have one invertor single phase input three phase out put new but no functional help me
HiIs there a vfd for a single phase motor ?
Hello,please also explain inverter control with relay for manual control of vfd driven motor
Sir, please suggest me can a vfd be powered by DC source generated by the solar panel
interesting question i doubt it but would be good to know how to do this .
It would be much more educational if the wires were refered to by their types (such as live or neutral) rather than their colours.
ヽ༼ຈل͜ຈ༽ノ l the red black green of 220V is standard for north America. The UVW doesn't matter as long as it goes to the proper pin
Where do i connect the encoder
I want to ask that on single phase VSD on the same connection is it where u connect wires of electricity and of the solar panels .
How do I do that VFD connection in a air compressor with a pressure switch? Thanks a lot!!!
would a 3ph VFD work on equipment like a widebelt sander or edge bander with multiple motors ?
How about the one with dc in?
Do you have a tutorial on how to connect a single phase motor to a single phase vfd :)? I've seen people do it and I need to do it but I would like to know how to :).
I just saw your post. Did you receive your answer? I have the same question
By grounding via cable to a ground star bar, does having the VFD case grounded to the control panel backer not cause a ground loop by having two grounds come from the drive?
Does vfd need braking resistor ? In my vfd I have braking resistor terminals
Please i want to buy single phase 2.2 kw vfd, will this run any 3 phase more below 2.2 kw, will some one advice, thanks
great video, thanks for loading
Where does the white wire go thst is coming from the 220
Wondarful sar
I have one 5hp solar pump in myagriculture field
But some problams in burn thisvfd d700
So no many iam poor farmar.
Present in not working thisvfd .
You don’t specify for what country?
Here in Oz - we have 4 core + Earth wires:-
L1 Red
L2 White
L3 Blue
Neutral Black
Earth Green with yellow stripe!
And it’s 440 volt 3 phase.
L1 L2 & L3 are interchangeable to reverse parity on 3 phase motor & get it to spin correct direction.
great work . but i have a question I have a single phase motor and i want to make speed control so how i can connect it on the output of vsd
Eslam, you will need a three phase motor. VFD works with three phase AC/DC electric motors.
It is not possible to conect single phase to vfd for variation freq it must be 3 phase to change.
Control cable wiring procedures. ...?
Could you tell us about the problem of my vfd,we have 3phase vfd and i try to wiring installation but still 000 display in indicator when i start push button, Actually i lost manual for this vfd can you help us,. thanks
can a vfd power a primary transformer in a welding machine to fine tune a arc or mig welder yes not wiring on the circuit board side
Lanclot, a VFD is used to control electric motors, they do not power the motors or transformers for that matter. Feel free to check out our video "what is a VFD"
My motor is rated 4.8 a and vfd is 2.3 output , so these two won't work together?
Is it solar connection ?
Where can I find info on how to program a VFD? What do the parameters F, H, A mean on the display and how can I set the freq. to 130 Hz?
If you are trying to program Mitsubishi VFDs, check our video library and you will find other videos showing some basic programming. Every brand of VFD has different terminology, so we can't answer what F, H, A means unfortunately.
For any programming specific for your machine, you will have to consult your manual for the parameters or find a local electrician who has experience with VFDs.
My pto generator output frequency is 38 to 40hz will this help me to convert the frequency from 40hz to 60hz??
Hi VFD Team, I'm from Germany and I'm trying to wire my singlephase VFD to a 3phase Motor.
Here in Germany we have one Hot wire one neutral and eart. My VFD doesn't say anything about the neutral ...
Do you have any Idea how to wire an VFD with only one hotwire ?
Jan Bane my imo number +8801912410502
would you please tell connections of 3 phase motor to vfd and how the speed of 3 phase motor is varied?
How do I power with battery...and can I use it at home to maybe power my TV running on the batteries?!
Sir will u pls explain control wiring
Do you use a screened motor cable?
You should use emc shielded cable between vfd and motor and install vfd into metal cabinet
please show me control wiring I am confused all ways please help me.
No neutral wire connection?
very well explain, thank you.
The part I am getting tripped up on is how to wire in a switch to the line side going into the vfd so I do not have to leave it on constantly. From what I can gather I will need a DPST switch rated for the correct amperage but I can not seem to find any 2 articles or opinions that say this is the correct way to configure the switch.
Some say that a switch will always burn out others say they have had a switch on theirs for ages. My manual does not list any control ports for a power switch and i I understand it correctly it goes as far as saying that a switch should not be used to control the run/stop of the drive. I take that to mean that you should not use a switch to put the unit under a load not just powering the unit on but I am admittedly getting a little cautious.
Any guidance would be appreciated.
how to run 3 motors on one VFD???
Im from Mexico City and I have a hard time understanding the name single Phase if you are using 2 hot wires, isnt single phase 1 phase and 1 neutral?
Ernesto Moctezuma residential 240 is still considered single phase
And ground.
Thanks Steve. I've been suscribed. I'm doing my tesis with VFD controlling a pump and so with PV energy.
is there any VFD available working at 48volt?
Did you mean 48 or 480? 480 yes, 48 no.
I mean 48v
Hi how can get scamatic diagram of Delta c2000 that u can oparat the motor low speed and high speed
It is only power wiring no control wiring you should wire the potentio and the reverse and forward direction.
Haw can install my submasible pump 1.5 with ac drive model SG320~4k0GB~4T
what is the diffeence between 2 wie and 3 wire vfd?
Gravity in My Party 1 phase converted to 3.
hi brother . can you tell me how can i adjust external veriable of this invertr E700
Do you sell 1 phase in and 1 phase out?
sir can you till me how to wire up two inverte master and slave control wiring with potentiometer
Can i input dc 400 v to vfd instead of three phas terminals R. S. T for run the motor i have yaskawa 616G5 vfd model CIMR H5A4037
Shahbaz, this is an AC VFD pairing with AC motors. If you have a DC VFD, you will need a DC motor. The wiring might be different since the VFD is manufactured by a different company. Emerson makes great DC VFDs.
How to decide source or sink ?
Hi, I am a mechanical engineering student working designing a screw conveyor as my senior project. I have a Baldor 1.5 hp brake motor. I need it to power a conveyor that will have a speed of 20-40rpm. As of now, I have a gear box with a turn-down of 20. Additional to it, I am thinking to use a VFD to control the speed. At this point, I need to start selecting a starter and VFD and need some help with that.
Hi Sofia,
A VFD acts as a starter, so you shouldn't need one if you have a VFD. What is your input power voltage and phase? What is the voltage and FLA of your 3 phase 1.5HP motor?
DC voltage not out put
Could I connect a VFD to an Arduino?
yes
Sir plz lell me how to make the connection from starting to end also what is the use of vfd in motor two 3 types vfd
Greatest video on VFD.
Thank you for this very helpfull video, please help me program a VFD for PID control and explain all the parameter in detail . Hope to see your new videos soon :) :)
hello friend,
I am working in a solar panels company my manager asking a question to me.what happening the +ve and -ve terminals are changed into the drive is burning or working.
Thiru, I am sorry but I don't understand what you are asking.
my question is what happen in +ve and -ve polarity changed in the inverter circuit.
Does this have to do with the VFD wiring? We still do not understand what you are trying to ask.
You're explaining how to connect a single-phase VFD (L-N), but you ended up wiring it as a 2-phase (R-S) one! Why is that?
is it possible to use arduino as a party command of this VFD, and thanks in advance
You'd be most likely able to drive any VFD with arduino - it's controls are like analog input for speed control and digital inputs for rotation direction, emergency stop etc.
Hello can I use 1 vfd into multiple motors?
Yeah, as long as the motors dont exceed the rated Amperage of the VFD
I have a delta 3.7kw VFD. I am using 230V BRWG (black, red, white, green) from my panel to L1,2,3,G respectively. I am using the same for T1,2,3 G. I am getting 220V to ground from each line into the magnetic start panel. I have selected the H4 220V terminal of the transformer that links to the magnetic switch (previously it was on 460V H3). When I hit the start switch I get a rapid clicking of the magnetic switch and no motor engagement.
I called delta and the tech told me one of the three line legs coming in from the VFD is a "fake leg" and that must be connected to T3 or L3 depending on which end of the wire you wish to view. How do I identify this so called fake leg? I see no info in the manual about this. I am using this VFD to drive a 5hp motor for a delta unisaw (34-806) which I wired from delta to wye.
I am not used to needing help for such things, but I am at a loss on this. Has anyone encountered this before?
Rollin,
We need more information in order to answer your question. (1) We are not sure what you were referring to when you said "fake leg"? (2) What exactly is the magnetic switch that you mentioned? What does it do? Where is it located in the arrangement of the electrical components? (3) Where is the transformer getting its primary power? (4) Do you have a contactor after the VFD? If you are trying to close the contactor after the VFD is turned on, it will not work.
Let us know. Thanks.
how match price
Sir can u invite your work place
VFD Danfoss 45kw motor drive earth fault delay fault plzz definition bro
F700 mtsubıhı inverter eov3 hatası neden olabilir program salımı yoksa elektronik hatası mı
which terminal connect to the potentiometer.?
Totally Drive-Dependant. Each Manufacturer is different.
Hi. Confused a little, you say single phase which is one wire and a neutral to return. You have said two hot wires so is this 240v instead of 230v?
230v and 240v is the same thing. single phase power can be either 120v (hot and a neutral) or 2 hots as "nominal" 230-240volt. same thing like, potatoe potatoo .. lol
i was thinking about same thing
Emma Burns of course. 3 phase has 2 hot and 1 neutral.
stop guiding people with wrong direction. there is no neutral on 3 phase.
Robert is right. It’s 3 hot phases for - 3 phase. Sometimes there’s a neutral in addition, if 120 is being taken off one phase.
Sir vfb me e.thm signal aa raha Hai kya problem Hai please batao
Very Nice Video, Did A Mistake At 3:57 "Single Phase In Single Phase Out"
Thanks For Uploading Anyways...
+XspydareX Xarrior Thank you! He meant to say, "single phase in, three phase out".
+VFDs.com yes dear i understand
i jus said it was unconsious mistake
hello , why did he say single phase and hes using two hot wires
@@ErnestoMoctezumaoro live is always live, neutral becomes live when all switches are closed so both can be called "hot"...
@@ErnestoMoctezumaoro He forgot to mention it was single phase 220 volts in and 3 phase out.
I would like you to help me with a wiring circuit for two level sensors on a MOTOLINE frequency drive
That eye is amazing!
3 phase dc or ac output?
This is an AC drive, so it is AC output. It goes to an AC motor. There are DC motors and DC VFD out there but this one is AC.
In 3 phase vfd... If we connect neutral to earth what happens
VFDs from Mitsubishi have very good manuals and explain wiring differences when using single or 3 phase.
Please I want control diagram
Nice video
Very thankful vedio but sir controling wiring via vfd connection make vedio