Studio 5000 & RsLogix 5000 Produced and Consumed Tags

Поділитися
Вставка
  • Опубліковано 6 вер 2024
  • In Controllogix and Compactlogix PLCs, produced and consumed tags take place of messaging instructions for relaying information between two Allen Bradley PLCs. Additionally produced and consumed tags are deterministic compared to a MSG message instructions making them a much more reliable means of communications.
    Get the full details of this lesson at controls.tw/yt...
    Items used in this video:
    PLC Trainer controls.tw/yt...
    The above links make these videos possible. Please use them!
    Support these videos while you advance your skills controls.tw/yt...

КОМЕНТАРІ • 45

  • @bayareajacob
    @bayareajacob 3 роки тому +8

    Your timing is always perfect. Just ran into a issue in our new can plant that I needed to figure out why are produce and consumes werent working. This was a great video and now required watching for the new guys and gals in the shop.

  • @nami_isik
    @nami_isik Рік тому +2

    I sincerely thank you for your descriptive explanation and for solving our problems.

  • @khalidzeidan6063
    @khalidzeidan6063 Місяць тому +1

    Great video.

  • @mosalah2265
    @mosalah2265 Рік тому +1

    Many thanks for your time ❤

  • @lucianoteles2109
    @lucianoteles2109 2 місяці тому +1

    muito top os videos.obrigado teacher

  • @worksux82
    @worksux82 Рік тому +2

    This is a great video but I'm looking to find the used bits in a plc. Do you have a video showing how to find the open hard wired bits available to use?

    • @TimWilborne
      @TimWilborne  Рік тому +1

      Right click, cross reference and look at the destructive column to have a Y in it. Also there when you're selecting them, they are dark gray if they have already been used and life gray if not

  • @rangaswamy8604
    @rangaswamy8604 3 роки тому +4

    Good video but video froze at the end part when you were explaining tag types and monitoring.

    • @TimWilborne
      @TimWilborne  3 роки тому +2

      Yes, didn't realize it until after I posted it, I'll get it fixed and re-uploaded

  • @user-se1kt1wl6x
    @user-se1kt1wl6x 9 місяців тому +1

    Quick question about this. As far as traffic over the network, do MSG or produced/consumed tags have a larger bandwidth?

    • @TimWilborne
      @TimWilborne  9 місяців тому +2

      I don't know. I would think it would have more to do with the consumed RPI compared to the sample rate of the MSG than the actual packet size.

  • @learning9503
    @learning9503 Рік тому +1

    tags used by HMI, consumed or produced? how to search them in logix5000?

    • @TimWilborne
      @TimWilborne  Рік тому +2

      They would only show up as base tags in Studio 5000.

  • @malcolmandthebends2914
    @malcolmandthebends2914 3 роки тому +1

    Very Cool thank you Tim!

  • @James-oj6lk
    @James-oj6lk 10 місяців тому +1

    Hey Tim, is there an advantage to using produce/consume tags vs. msg instructions, to send info between plcs? Network wise?

    • @TimWilborne
      @TimWilborne  10 місяців тому +2

      Yes, produced/consumed tags are "deterministic" meaning you will know if it fails. MSG instructions are limited on number and don't take the priority of produced/consumed tags.

    • @James-oj6lk
      @James-oj6lk 10 місяців тому +1

      @@TimWilborne

  • @justinmartin4751
    @justinmartin4751 Рік тому +1

    heh Tim, Thanks very much for this video on Producer/Consumer tags. I'm taking my first RSLogix PLC course this term at school, and for today's lab the Instructor was explaining on how we set up 2 RSLogix PLCs for Master and Slave communication. The lab involved in removing the processor for the Slave PLC and then adding all the I/O modules of the Slave PLC to the Master PLC. The goal was to be able to have the Master PLC operate the I/O assigned to the Slave PLC. I kinda got lost in this lab, so I was wondering do you have a video that describes how to set up this type of operation? Unfortunately our lab manual does not go through and explain the set up process very well. Thanks again for these videos, they have really helped me out. Justin

    • @TimWilborne
      @TimWilborne  Рік тому +1

      Glad our videos have been helpful Justin. What PLC were you using?

    • @justinmartin4751
      @justinmartin4751 Рік тому +1

      @@TimWilborne Heh Tim. I am using the RSLogix5000 (Studio 5000 Logix Designer) with the 1756-A10 chassis and the 1756-L81E ControlLogix Processor.
      I think this is what information you're looking for. Thanks again Justin

    • @TimWilborne
      @TimWilborne  Рік тому +1

      @@justinmartin4751 For just a remote chassis, you wouldn't use the Produced and Consumed tags. Just right click Ethernet under IO Configuration then New Module.

  • @josevitorandrade5233
    @josevitorandrade5233 Рік тому +1

    Is there a way to detect timeout easily using this method?

    • @TimWilborne
      @TimWilborne  Рік тому +2

      Yes, you can use the GSV instruction to see the IO light.

  • @hiwaabdulrazaq7920
    @hiwaabdulrazaq7920 3 роки тому +1

    Thanks

  • @brucecasilio42
    @brucecasilio42 3 роки тому +1

    thank you for all your videos - do you have training sessions and where are you located - thanks

    • @TimWilborne
      @TimWilborne  3 роки тому +1

      We do in person training in Roanoke, VA. See link below.
      twcontrols.com/plc-lab

  • @timcombs7646
    @timcombs7646 3 роки тому +3

    Your video froze up as you were monitoring the tags for troubleshooting.

    • @TimWilborne
      @TimWilborne  3 роки тому +2

      Oh no! Did you happen to catch the time?

    • @timcombs7646
      @timcombs7646 3 роки тому +2

      @@TimWilborne it started earlier, but pretty much everything after about 18:33

    • @TimWilborne
      @TimWilborne  3 роки тому +1

      @@timcombs7646 Not sure what happened, the rough draft has it but sure enough, this one doesn't. Thanks for pointing it out.

  • @horacioarturomosquerapandu9897

    what about float or real tags

  • @johnrece6622
    @johnrece6622 2 роки тому +1

    Do those function the same in rs5000?

  • @brucecasilio42
    @brucecasilio42 3 роки тому +1

    do you sell your trainers - thank you

    • @TimWilborne
      @TimWilborne  3 роки тому +1

      Yes we do Bruce. See link below.
      twcontrols.com/plc-trainers

  • @HR-fw2de
    @HR-fw2de 3 роки тому +1

    👍🏼🌹

  • @joaquimferreira4796
    @joaquimferreira4796 3 роки тому +1

    Thanks