2 SERVICE CALLS. LIQUID LINE RESTRICTION AND PRESSURE SWITCH ISSUE

Поділитися
Вставка
  • Опубліковано 29 сер 2024
  • Come ride along for two service calls.
    First service call is dealing with a liquid line restriction. The system has an outdoor piston,
    Indoor txv and bi flow filter drier on heat pump for cooling season. ICP system.
    Second call is a Carrier that will not start. The air handler is sending the voltage to the condenser however other pressure switch issue.
    Please like and describe. ‪@hvacotj‬
    Check out hvacotj on Instagram if you’d like.
    #airconditioning #hvac #carrier #honeywell #nest #carrierhvac #electrical

КОМЕНТАРІ • 5

  • @In4mnt
    @In4mnt Місяць тому +1

    Keep the videos coming Paul. Love the content!

    • @hvacotj
      @hvacotj  Місяць тому

      I appreciate your words. Thank you very much

  • @realSamAndrew
    @realSamAndrew Місяць тому +1

    🎵🎵🎶 There is only one river, there is only one sea...

  • @Richard-zz2cb
    @Richard-zz2cb Місяць тому +1

    What’s funny is I had a call like the 1st call in this video today, same model. 80 psi on the suction line and 345 on the head side. Subcooling normal 8 but my superheat was 76. Put unit in heating and pressures looked normal a bit high but normal and it was heating properly. Put unit back in cooling and opened the air handler and put my hand over the bulb, pressures didn’t budge, superheat and sub cool the same. Txv was freezing that mf was almost all the way closed. No temperature difference on filter drier, quoted new txv

    • @hvacotj
      @hvacotj  Місяць тому

      Yes it’s a tough call on those. I really show much about that call because they can be tricky. I still quoted the flat rate txv the piston outside and filter drier because we will have line set open anyway. Thanks broski.