System Cannot Work Like This. An Uncommon Find!

Поділитися
Вставка
  • Опубліковано 10 кві 2023
  • In this video I go to one of a few calls for a new customer. I hope I have proved myself better than the last company. #hvacguy #hvaclife #hvac #airconditioner #heatpump #hvactechnician #acrepair #furnace #hvacinstall #hvactech #hvactrainingvideos #hvactroubleshooting #mobilehome ‪@ruud‬
    Merch Store: hvac-guy-2.cre...
    HVAC LIFE FB Group: / 521086622906115
    Here are links to the tools I use, And it costs you nothing extra to buy from this list:
    Yellow Jacket Tubing Expander: amzn.to/3EvEQnF
    Yellow Jacket 60278 Flaring Tool: amzn.to/3FPjlyY
    Veto Pro Pac Tech MCT Blackout: Amzn.to/3iCieJK
    DeWalt work table: amzn.to/3fKChoB
    Inficon D-tek Stratus: amzn.to/3zNg7IO
    3 Amp Lil’ Popper: amzn.to/3D5lt3e
    Inficon D-Tek Stratus: amzn.to/3RvnXOl
    Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
    Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
    Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
    Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
    Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
    Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
    Fieldpiece Blutooth Scale: amzn.to/3Gzveab
    Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
    Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
    Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
    Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
    Milwaukee M12 Impact Driver: amzn.to/37xXkqk
    Makita XDT16: amzn.to/3riXuaJ
    Makita 18V Light: amzn.to/3Fw4GW4
    Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
    Makita 18V Battery Mounts in Van : amzn.to/3GxpVID
    Makita Jobsite Radio: amzn.to/3HuVp2u
    DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
    Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
    Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
    Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
    Klein Knee Pad: amzn.to/3cy6FB0
    Klein 7in1 Flip Socket: amzn.to/3bpabwG
    Klein Journeyman Pliers: amzn.to/3tvB60w
    Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
    Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
    Milwaukee Tool Box: amzn.to/322iyK9
    Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
    Milwaukee Hook Blade Knife: amzn.to/33F3m5T
    Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
    Western Nitrogen Regulator: amzn.to/3rmdKrx
    Klein Canvas Bucket: amzn.to/3FyzKVf
    Flag Velcro Patch Kit: amzn.to/3K8Eswx
    Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
    Milwaukee Magnetic Light: amzn.to/3FulCfF
    Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
    SS2 Float Switch: amzn.to/3K7LJMW
    3-Amp Breaker: amzn.to/3nxaSXJ
    Appion Valve Core Removal Tool: amzn.to/33CFArw
    Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
    Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
    Similar Small Tubing Bender: amzn.to/3fJsziJ
    Fluke Twist Guard Test Leads: amzn.to/3216R6j
    Fluke 975 Air Meter: amzn.to/3GwD9oM
    Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
    Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
    SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
    Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
    Quick Check Acid Test: amzn.to/3GA2XAy
    Wiha Torqe Screwdriver : amzn.to/3u1swH6
    Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
    Compressor Tote: amzn.to/3H8xHst
    Inspection Mirror: amzn.to/3r9PERV
    Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
    1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

КОМЕНТАРІ • 109

  • @TofuInc
    @TofuInc Рік тому +7

    It's just a 1/2 ton undersized... Put in a TXV and bump up the fan speed.

  • @kens.3729
    @kens.3729 Рік тому +19

    There are Plenty of Contractors in ALL Different Fields that have NO Idea what they’re doing and have NO Business being in the Business of Repairing Anything. 🤪

    • @wayneschneyer8699
      @wayneschneyer8699 Рік тому +3

      Amen! As a former major brand regional service manager, I’ve seen it all.
      Curtis and many others are true professionals with ethics.
      Some of theses clowns should do some jail time for what I’ve seen them do to innocent customers.

    • @Unacceptable462
      @Unacceptable462 6 днів тому

      THAT is why they are called....CONtractors!!!!!!!!!!!!!!!!!!! :)

  • @kens.3729
    @kens.3729 Рік тому +14

    If you’re a One-Man Band, I’m really amazed that you’re able to keep up with your Business because I know you get a Lot of Repeat Business and Referrals. 👍

  • @sergiohernandez4163
    @sergiohernandez4163 Рік тому +10

    To my understanding some of the coils would work on 3 up to 4 ton but I might be wrong.

    • @Mitch2294
      @Mitch2294 Рік тому +2

      Proper metering device is key. If the coil is starved Upsize the piston not the greatest for efficiency but you could probably make that coil work.

  • @Chris-ru3ri
    @Chris-ru3ri 10 місяців тому +2

    I miss those old Rheem units

  • @549BR
    @549BR Рік тому +20

    In reference to mobile or manufactured homes, my experience was good with the tenants or owners, and generally not good with the property owners or landlords. They were usually very cheap, and didn't appreciate a high caliber contractor. That unmowed lawn would be the first tip off about the presence of cheap. Hopefully, you will give us a follow up on that call. Good video as usual. 😎

    • @HVACGUY
      @HVACGUY  Рік тому +11

      They didn’t balk on my prices

    • @cardsfan-ym1bj
      @cardsfan-ym1bj Рік тому +8

      I usually don't mind the mobile or manufactured homes,most of them in my area are privately owned no management company they just own the lot,but a lot of the big companies won't mess with em so I carved a nice lil niche out for myself.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Рік тому +3

      I keep telling him that. He must like being abused. I learned that in year one. Now on year 22 I still don’t work for landlords, apartment complexes, commercial businesses, builders or insurance companies. I make a good living, don’t have to wait on my money for weeks or months, rarely have a warranty call after I stopped selling junkitrol aka Goodman, rarely work weekends or after 5 pm. Why, do good work, take care of loyal customers, I’m picky, not anyone’s buddy and I charge above average prices for my area. If you are a low baller, I hope you like working a lot and spending time away from your family.

  • @user-ip4ke7ki2u
    @user-ip4ke7ki2u Рік тому +7

    Wow I don't understand how and why most techs did even try to check data plate on both air handler and condenser unit. HVAC GUY your best please keep making videos. When I went to HVAC SCHOOL I learn a lot from you. I have since graduated and I am working on the field as HVAC tech doing service and maintenance on the field. By the way my favorite video is OMG possible lighting strike!!! keep the good work. Hopefully one I would like to work with you a service call Thank you!!!

    • @HVACGUY
      @HVACGUY  Рік тому +1

      That’s Great. Thanks for Watching

    • @davidaustin9009
      @davidaustin9009 10 місяців тому +1

      As a student in 2018/19. I watch videos everyday..I learn something new.. constantly..this guy Curtis is Golden..keep learning guys.ans thank you tons Curtis..doing a fantastic job Mate..two thumbs up 😎

  • @dfwhvac
    @dfwhvac Рік тому +10

    Id verify that the evap coil isn’t undersized instead of the condensing unit being oversized. Maybe the duct work and cfm is made for 3 tons. It’s more likely that the evap coil is undersized, but still I’d wanna make sure just in case

    • @mikeanonymous669
      @mikeanonymous669 Рік тому +2

      Coil was likely replaced and thats why it looks new and had to have the lineset reducer brazed in. The outside unit is the original unit/size that should be mated with a proper size evap coil.

  • @donnyjackson1908
    @donnyjackson1908 Рік тому +14

    A nice 4 Ton coil and adding a TXV will likely tune that right in. I believe those Coleman MH Electric furnaces come with a 4T blower drive so should handle 3.5T on high speed.

    • @Balticblue93
      @Balticblue93 Рік тому +9

      That is literally exactly what I said. Throw a 4-ton coil and TEV in and possibly upgrade the blower motor, but a half ton coil is not going to magically fix the system. That is barely worth the work.

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Рік тому +1

      Yeah, the cheap ductwork can’t handle 3.5 ton though. That’s why you put a tall 4 ton coil in there.

    • @timesfly1081
      @timesfly1081 9 місяців тому +1

      I came here for this comment 😂
      At least he got a sale out of it
      Silver lining?

  • @robalexander7348
    @robalexander7348 Рік тому +4

    That was a good find Curtis, it takes a good service man like you to find that unusual problem 👍

  • @chrissipple1018
    @chrissipple1018 Рік тому +5

    A different evaporator wil help, but unless that mobile home was built for cooling the duct work is sized for heating too small.

    • @adampajcz8719
      @adampajcz8719 Рік тому +2

      No mobile home is designed for cooling. Landlord probably had a 3.5 Ton condenser sitting around and had someone install it when theirs broke down.

  • @Hvac101
    @Hvac101 Рік тому +11

    I wonder if the ducting or blower can handle 3.5 tons. Good content as alway Curtis. 👍🏻

    • @staind288
      @staind288 Рік тому +2

      I have a 3 1/2 ton in my double wide. Just put in a little over a year ago. Seems to work fine until Temps get in the 90's. That's just due to poor insulation

    • @USA-GreedyMenOfNoIntegrity
      @USA-GreedyMenOfNoIntegrity Рік тому

      3 1/2 ton is max on AC only, 3 ton for heat pumps. Always upsize my indoor coil 1/2-1 ton bigger than the outdoor unit.

    • @clintgray1623
      @clintgray1623 10 місяців тому

      On double wides need to upgrade the blower motor to 3/4 Hp
      Complete motor and squirrel cage assembly,

  • @williamtorres3394
    @williamtorres3394 Рік тому +4

    Nice work 👍🏿

  • @user-vy2tx8uc1u
    @user-vy2tx8uc1u 10 місяців тому +1

    i think you are on it curtis. Thanks For the video. Im "assuming" this problem is a new one and not been a problem since installation. Makes me think ductwork and blower aspects are Fine. New coil with correct piston should get this one rolling. btw, im assuming we know the previous company replaced the evap with a smaller one. maybe they Found a leak and replaced coil, kinda like they Fixed an issue and caused another one. Thats where my mind is at on this call.

  • @zekenzy6486
    @zekenzy6486 Рік тому +2

    Great Video . Thank you for sharing

  • @mwdub02
    @mwdub02 Рік тому +9

    Usually we go a half ton higher on the Evap. You might want to get a 4T coil if your drive can handle it. Good catch man

    • @Balticblue93
      @Balticblue93 Рік тому +5

      100% agree and exactly what I said. We size up a half-ton on all our systems here in Denver.

    • @joshuaseaton4526
      @joshuaseaton4526 Рік тому +2

      No way, why upsize on a small trailer when the ductwork is high static as it is?? I would do an entire heat loss/gain calc and then replace both based off my numbers. I would gather that place needs probably a 2 or 2.5 ton unit.

    • @woodworkking1099
      @woodworkking1099 Рік тому +1

      @@joshuaseaton4526 Exactly correct Josh, mwdub is drunk. What he is suggesting was 20 years ago solutions....lol

    • @mwdub02
      @mwdub02 Рік тому +2

      @@woodworkking1099 I don’t know about you dude but we do VRF systems and that’s top of the line that very few techs can touch. They still oversize their Evap coils. Probably LG and Daikin is drunk too. It really application dependent and I’m not being specific here kid.

    • @davidhazas7162
      @davidhazas7162 Рік тому +1

      Yea that oversizing evaporator coils hardly turns out good for the compressor. I dont get why manufactures go for that.

  • @JohnSmith-ug5ci
    @JohnSmith-ug5ci Рік тому +6

    Good catch. Hopefully this will be a new client for you.

  • @PlumberD
    @PlumberD Рік тому +6

    Awesome catch …and did you sell them a dang battery for their smoke detector??!!!

  • @DevinHVACInc
    @DevinHVACInc Рік тому +3

    Good find.

  • @EverythingHVACR
    @EverythingHVACR Рік тому +2

    Good catch Curtis!

  • @johncspine2787
    @johncspine2787 Рік тому +4

    Amazing..ppl look, but don’t see! In Utah we are having a freak 80+ day right after over a foot of snow literally just melted off..I switched my Mitsubishi mini split (a four head of five available) to cooling, and first was trying to run it like I’m used to down south, with high manual fan settings, and it just..never shuts off even when you reach temperature..so, I do my research, and just put the four heads on auto, with certain rooms at certain temperatures, and..it’s shockingly, shockingly quiet! Both the indoor cassettes, and probably even more shocking is how quiet the outdoor unit is..I’m used to hearing….”BBBLLLAAAAAAAAAAAAAAAHHHH!!!”.. from every outdoor AC I’ve ever heard, and this thing just sort of gently makes a draft of the warmth off the coils..then as I’m standing there, it ramps it down even slower..I’m just amazed by this technology..I’m only using four of the available five heads because I only have four main rooms upstairs, and didn’t see a need to install the fifth one downstairs as I’m by myself, the downstairs seems cool all summer as I’m set into a hill, you walk in my ground front door, then go downstairs and walk out the back of the house, so it stays pretty cool in summer. I think the cassettes are a 12 in the kitchen, 9 in living room, and two 6000 in the bedrooms..the kitchen is west facing so they bumped up the capacity. I’m just beyond thrilled, but, I’ll have to see how it handles the 107 degrees when it comes!

  • @JoseJB0
    @JoseJB0 Рік тому +2

    One of the 1st things that should be checked 👍 🍻

  • @RadioReprised
    @RadioReprised Рік тому +3

    At 10:50...isn't half of the upflow just porting around the coil ?! Foil ain't sealing a thing!

  • @skinguru8531
    @skinguru8531 Рік тому +2

    I hope you get some new business👍👍👍

  • @jameybaker9643
    @jameybaker9643 Рік тому +5

    A 4 ton Evap coil would do a great job!

    • @bills6946
      @bills6946 23 дні тому

      Better dehumidification, for sure

  • @kbmblizz1940
    @kbmblizz1940 11 місяців тому +1

    To help non-trades, superheat too low, suction (return) line ice cold but not enough cooling (air temp drop thru heat exchange) could mean not enough airflow, wrong piston or undersized evaporator. He thinks it is the latter.

  • @georgewelker853
    @georgewelker853 Рік тому +2

    I would suggest to double clean that indoor coil. Most of the 3.5 ton condensers will do reasonably well with a .5 ton smaller indoor coil

    • @gor312
      @gor312 Рік тому +1

      I'd say the more likely problem is that they have the totally wrong orifice in the system. A 3 ton orifice with a 3.5 ton condenser would give you a very low evaporator pressure and low efficiency. A slightly smaller coil would just mean somewhat lower efficiency, but this wouldn't prevent the system from working.

  • @woodystokes1543
    @woodystokes1543 Рік тому +2

    Boom 💥 nice job 👍🏼

  • @YukonHawk1
    @YukonHawk1 Рік тому +2

    That was a mess. I hope they change the battery in the chirping smoke detector.

    • @analogmoz
      @analogmoz Рік тому

      It's not a proper video from Curtis unless there's a barking dog and a failing battery on the smoke detector.

  • @jaysonescoe5799
    @jaysonescoe5799 Рік тому +1

    Haha I didn’t think you pulled that yard hydrant’s handle up enough to start with.

  • @stanleyroberts2461
    @stanleyroberts2461 Рік тому +6

    Is the blower big enough to handle a 3.5 ton unit? Always good to pick up new customers. Keep up the good work

    • @timesfly1081
      @timesfly1081 9 місяців тому +1

      Honestly I’d try bumping the blower to high speed first before replacing it

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Рік тому +4

    Did you a delta split across the evaporator. Hopefully your ductwork can handle 3 1/2 ton Might ask owner to resize to matching 3 to ton

  • @harrydickson4575
    @harrydickson4575 Рік тому +3

    Awesome 👍👍👍

  • @realSamAndrew
    @realSamAndrew Рік тому +3

    What does that steaming coffee cup ☕ mean on the leak detector display? 7:54

  • @Gutter-Snipe
    @Gutter-Snipe 10 місяців тому +1

    first off if your AH can move 3.5 ton of air Coil is not your problem. it does in fact derate the system as a hole some and i am not familiar with what a double wide needs in your area. that aluminum foil trying to block the Air gap in the front of the coil is a potential major problem, add that to the open air intake at the top of the air handler might be the hole ball of wax. some air flow testing might have been a good idea, could also be a TXV with air going around the coil. just my 2 cents performance data of the coil outdoor match up might be just find for sensible and laten.

  • @fernandobazan829
    @fernandobazan829 9 місяців тому +1

    what is it with those smoke alarms it would drive me crazy lol

  • @jamesfitzsimmons381
    @jamesfitzsimmons381 Рік тому +3

    Still think you should measure the ductwork and size a new system if it comes out to only 3 ton of air

  • @cardsfan-ym1bj
    @cardsfan-ym1bj Рік тому +3

    Weird seeing a upfkow in a mobile/manufactured home, I think that's a first for me

    • @clarkbreen4634
      @clarkbreen4634 Рік тому

      My neighbor has one too

    • @cardsfan-ym1bj
      @cardsfan-ym1bj Рік тому

      @@clarkbreen4634 interesting might be more common then I thought,but I can't remember seeing one in my area and I've worked on a ton of manufactured homes.

    • @clarkbreen4634
      @clarkbreen4634 Рік тому

      @@cardsfan-ym1bj I’ve seen a few but mostly downflow. Single wides have always been downflow

  • @daleborg9070
    @daleborg9070 Рік тому +1

    Curtis, I never heard you say what the complaint was as to why you were called.

  • @Mitch2294
    @Mitch2294 Рік тому +1

    Proper metering device is first pump it down and check the piston size you could Upsize the piston to feed that coil it’s definitely not going to be maximum efficiency because of the lack of surface area (smaller coil) but it should work most new units have lower btu per ton anyway that unit probably has a 36-38,000 btu compressor even though it’s a 3.5 ton. A quick google research would give you a definitive.while not recommended I think it could be made to work.

  • @yellowdeer7163
    @yellowdeer7163 Рік тому

    I once found a 3 ton outside an apartment with a 2 ton evap coil. The manager had a company put in the outside unit??.The line set outside went from 5/8s to 3/4! The resident kept complaining.The apartment had a vaulted ceiling and no insulation whatsoever. This was on a third floor here in Dallas. It was a losing battle with the manager. Talk about kicking a dead horse.

  • @latitude67
    @latitude67 Рік тому +1

    what about the stratus leak finder, i have tested a couple of different leak finders, and nothing beats the stratus in finding leaks, especially when searching for co2 leaks.

  • @jeffreyhalet9632
    @jeffreyhalet9632 Рік тому

    So the smaller A coil can’t handle the volume coming from the 3 1/2 ton outside unit.
    Which means the low insulation mobile home needs a higher volume of exchange ?
    Not an HVAC guy but love watching and learning from you.

  • @realestateservicessaleshea99

    Nice catch!!!🥃🥃🍺🍺🍺🇺🇲

  • @kens.3729
    @kens.3729 Рік тому +5

    What Decade do you think 🤔 that Coil was Last Washed Off ? 1990’s ? Totally Disgusting. 🤪

  • @gainestruk1
    @gainestruk1 Рік тому +2

    Wow that was a bad mistake from other company !

  • @majorintherepublick5862
    @majorintherepublick5862 Місяць тому

    Dirty as all out clean it! To get good pressure readings

  • @awshortclips
    @awshortclips Рік тому +4

    I'm no HVAC tech but isn't that unit way too big for that mobile home anyway? I heard when units are oversized they switch on and off (in AC mode) really fast and can make the place humid.

    • @mikeanonymous669
      @mikeanonymous669 Рік тому +1

      Most mobile homes arent very thermally efficient like a house. They are horrible to cool and just as bad to heat in the bitter cold. Didnt notice if it was a double wide or not.

    • @timesfly1081
      @timesfly1081 9 місяців тому

      Here in Florida, oversized units = MILDEW EVERYWHERE

  • @97Napkins
    @97Napkins Рік тому

    just my guess right after the evap was clean... Its got to be an undersized coil or wrong piston. could also be wrong blower drive.

  • @craigmarshall40
    @craigmarshall40 Рік тому +2

    1/2 smaller is that a big problem or 1/2 to big

    • @HVACGUY
      @HVACGUY  Рік тому +1

      You can increase by a half, but not decrease

  • @dwntwn3479
    @dwntwn3479 Рік тому +1

    Poor coil!! needs a good cleaning

  • @michaelburgess7703
    @michaelburgess7703 Рік тому +5

    Yes Curtis you oughta work on mobile homes that are 5 years and under. The old trailers the ductwork is probably falling on the ground cuz they got leaks from the sewer lines and everything. Curtis you're just wasting your time on those things you'll be better off doing new ones. I don't care if he has 100 of them mobile homes you be there all year. 😪😳🤨😵👍🤟

  • @joshuaseaton4526
    @joshuaseaton4526 Рік тому

    Hey Curtis, even if that unit reduced to 3/4 suction you would be ok. Rheem lineset charts are very forgiving. Very little efficiency drop between the common lineset sizes.

  • @joelmelendez5916
    @joelmelendez5916 Рік тому

    Tio ..what happen if u change only piston . ??? For a 3 1/2 piston .... ???

  • @greghughes9736
    @greghughes9736 Місяць тому

    There's Bubbles shed.

  • @clarkbreen4634
    @clarkbreen4634 Рік тому

    I actually thought being within a half ton was OK guess I was wrong

  • @karellodewijks4971
    @karellodewijks4971 Рік тому +2

    👍👍😊😊

  • @neutrodyne
    @neutrodyne Рік тому +1

    I am wondering if you could change the size of the orifice in the A coil to make it work? Would anyone with experience care to comment on this question?

  • @97Napkins
    @97Napkins Рік тому

    better not install a 3 and half ton coil unless its a 4 ton drive or same problem. I bet its 3 tons .. count the vents and the return size. better yet call the manufacture.

  • @elcheleland7372
    @elcheleland7372 Рік тому +2

    cheap and hacks companies giving you more job

  • @garyfishburn403
    @garyfishburn403 Рік тому

    Lost me on that one,didn't say what was wrong with the system .I guess you were saying the components were missed matched.Hard follow you if your not in the trade.

  • @USA-GreedyMenOfNoIntegrity
    @USA-GreedyMenOfNoIntegrity Рік тому

    There’s a reason why landlords like that have four or five different jacklegs working on their junk. They are cheap, slow to pay and rarely approve what needs to be done. I don’t work for landlords.

  • @Hvac-dude
    @Hvac-dude Рік тому +1

    That was a mistake

  • @PhillipCooperNCState
    @PhillipCooperNCState Рік тому +3

    I think you should install a 4 ton coil.

    • @Balticblue93
      @Balticblue93 Рік тому

      100%! Ditto on this answer. 4-ton all day and check the blower speeds.

    • @HVACGUY
      @HVACGUY  Рік тому +1

      I ordered a 3.5 - 4 ton

    • @PhillipCooperNCState
      @PhillipCooperNCState Рік тому

      Also I am in North Carolina, thus I will attempt to get an indoor coil that would generate an AHRI number. And if one was not available, I would NOTE on my invoice my unsuccessful attempts to locate one.

  • @Bryan-Hensley
    @Bryan-Hensley Рік тому

    The problem was right in front of you. You just stuffed it back in..the air is flowing around the coil where that half a** attempt to seal it with tape..

  • @timrob0420
    @timrob0420 Рік тому

    Hacks make me stacks

  • @ivancook1247
    @ivancook1247 Рік тому

    Nothing worse than working on mobile home crap, there junk from day one