MS02. [Siemens Motion Control] 9 Questions About Siemens Motion Control [2/10]

Поділитися
Вставка
  • Опубліковано 28 сер 2024

КОМЕНТАРІ • 42

  • @siphongxongo8589
    @siphongxongo8589 3 роки тому

    My King in Motion Control Salute....!!!!!

  • @gr.imadeddine324
    @gr.imadeddine324 3 роки тому +2

    Intresting topic, great video, thanks for sharing !

  • @logitronicengineering3240
    @logitronicengineering3240 5 місяців тому

    Thanks!

  • @alialshammary7188
    @alialshammary7188 6 місяців тому

    thanks for sharing

  • @ahmedatef5563
    @ahmedatef5563 2 роки тому

    Amazing topics

  • @BallAndBeam
    @BallAndBeam 3 роки тому

    Great video. Thanks.

  • @user-rw1pp3nh9e
    @user-rw1pp3nh9e Рік тому +1

    Your videos are very informative and thorough. Well Done!!! Question? I am trying to replace an S5 Rack of IP246 Positioning modules,
    I want to use an S7-1500 -1PN with TM2 Posinput modules and analog output modules (Drive Analog Setpoints) to control positioning axes with an SSI encoder feedback. Would that be the most efficient way to go?

    • @electricalautomation
      @electricalautomation  Рік тому

      If you migrate your system from S5->STEP7->TIA Portal, then you could use the way you wrote. using TM+SSI encoder and analog out can build up a position closed loop control in S7-1500 and basically your migrated program will have a very minimum change. Another way is that using a servo motor and servo drive and using the 2nd encoder channel from the servo drive (e.g. S120 DRIVE-CLiQ module) for measuring your load side position feedback. Is this application come from Iron and Steel RH air O2 gun application?

    • @user-rw1pp3nh9e
      @user-rw1pp3nh9e Рік тому

      @@electricalautomation No We are using it for automatic Size format change in the medical film industry. The IP246 module already has most criteria defined I imagine I can use things like incremental speed, software limits, Forward and Reverse Accel /Decel, etc. I am trying to upgrade incrementally so I am thinking of using FDL(open Comm) to communicate between the S5-135U and S7-1500 to transfer target values and other data.

  • @sotanluy2240
    @sotanluy2240 Рік тому

    thanks your so much, video very interesting :>.

  • @fernandocadena_
    @fernandocadena_ 3 роки тому

    Great video!

  • @tarik.b1400
    @tarik.b1400 3 роки тому

    wonderfull job thank you

    • @electricalautomation
      @electricalautomation  3 роки тому

      Thanks! This is one of the play lists I am proud of. thanks for watching!

  • @abujafor7915
    @abujafor7915 3 роки тому

    Thanks

  • @rahulravi4424
    @rahulravi4424 3 роки тому

    I would suggest you to have another Playlist relating SIMIT....it doen't have good resource except the manuals from siemens

  • @industrialautomationkotttu8841
    @industrialautomationkotttu8841 3 роки тому

    Keep going

    • @electricalautomation
      @electricalautomation  3 роки тому

      Thanks! will do! I am working on some videos about DC Motor positioning control by using S7-1200. They will be launched soon.

  • @tznalcn
    @tznalcn 3 роки тому +1

    Isnt tia portal basic enough for s7 1200 plcs with servo drive? For 1 axis robots for example. Great videos btw

    • @electricalautomation
      @electricalautomation  3 роки тому +1

      Yes, S7-1214 or higher can support 4 axis (single axis) control. You can use stepper motors or Siemens SINAMICS S210 servo motor as drive.

    • @tznalcn
      @tznalcn 3 роки тому

      @@electricalautomation Is it not possible for example with 1211C DC/DC/DC + V90 + Siemens Servo? If not how could we make it happen? Maybe with ET200? Thanks for the answer

    • @electricalautomation
      @electricalautomation  3 роки тому +1

      @@tznalcn Yes, it is possible. V90 is a good choice. some area cannot sale or buy SINAMIC V90. If you can buy V90, it is cost effective servo system, it also support profinet with s7-1200.

    • @tznalcn
      @tznalcn 3 роки тому +2

      @@electricalautomation Hey thanks for the information. By the way as I said before great videos. If you are looking for a topic for videos, TIA Selection Tool examples for motion control would be a great choice! Have a nice day!

  • @housamfraunhofer4473
    @housamfraunhofer4473 2 роки тому

    ich habe Siemens S120 , power module 27A,600vdc, and Double motor Module 600 vdc , 3Ac 400v 3A:
    is it suitable to connect with motor 400vac , 6,7A ?

  • @koffikoudjra2362
    @koffikoudjra2362 2 роки тому

    Hi
    thank you for sharing this with us,
    may you help me with the "sizer, TIA Selection Tool Online/Offline" links, please ?

    • @electricalautomation
      @electricalautomation  2 роки тому

      Please find the link for TIA selection tool new.siemens.com/global/en/products/automation/topic-areas/tia/tia-selection-tool.html

    • @koffikoudjra2362
      @koffikoudjra2362 2 роки тому

      Thank you very much!

  • @braincrackz
    @braincrackz 3 роки тому

    Hello can you share about alarm trigger and handling in siemens s7 300 cpus. If thats okay for you. Thanks

    • @electricalautomation
      @electricalautomation  3 роки тому

      Hello, do you mean using Siemens HMI to show the alarm, and the PLC is S7-300? It would be coming month but not recent. I am working on the motion control and communication series these months. Thanks for watching!

    • @braincrackz
      @braincrackz 3 роки тому

      @@electricalautomation not really in the HMI because i am not that yet but the logic i made in DBs can be use in HMI for future use. I only focus on the logic i made a logic for alarm trigger using bools and the problem is i want to make a reset that is in MOVE because i cannot afford to use so TONS of Reset Bit. Using 300 cpu. The idea is splicing the word command into bit in 300 its not possible.anyhow i love watching your videos its more advance

    • @electricalautomation
      @electricalautomation  3 роки тому +1

      I roughly see what you talked about. From my programming style, using the bits from a word from individual alarm, then compare this "word=0" for alarm summary.

  • @kalegamingtv2200
    @kalegamingtv2200 6 місяців тому

    from this video, i know, i bought wrong device for synchronize position

    • @electricalautomation
      @electricalautomation  6 місяців тому

      Hopefully the video could be helpful. Would you pls let me know which drive and PLC you bought, and which kind of application you want to do