MS03b. [Siemens Motion Control] TIA Portal Technology Object (TO) Configuration [4/10]

Поділитися
Вставка
  • Опубліковано 28 сер 2024

КОМЕНТАРІ • 24

  • @selimalan8145
    @selimalan8145 3 роки тому +2

    Very useful channel. Thank you for being such a channel
    Greetings from Turkey

  • @hamzajmili92
    @hamzajmili92 3 роки тому +1

    Thank you for this effort

  • @maza6357
    @maza6357 3 роки тому

    Thank you for great videos

    • @electricalautomation
      @electricalautomation  3 роки тому

      My pleasure! Thanks! I am working on the encoder/high pulses counter of S71200. Those videos are coming soon!

  • @AnimSparkStudios
    @AnimSparkStudios Рік тому

    Great effort

  • @2tan90
    @2tan90 2 роки тому

    thank you

  • @richardbanda2817
    @richardbanda2817 Рік тому

    Great explanation and that you. Would you perhaps have a video of setting up two synchronous axes?. If so, may you kindly direct me to that please.

    • @electricalautomation
      @electricalautomation  Рік тому

      Hope this video would be helpful ua-cam.com/video/hie46Yd37uI/v-deo.html

  • @elnursucayev6625
    @elnursucayev6625 2 роки тому

    Thank you. very useful lessons. Please show how you can instal all tia portal version on one PC

    • @electricalautomation
      @electricalautomation  2 роки тому +1

      They can be installed together. You'd better install from the lower version V12 to V17 higher version one by one. It is not recommended to install multiple versions of WinCC Professional in one system. Regular Step7 and WinCC advanced should be no issue.

    • @elnursucayev6625
      @elnursucayev6625 2 роки тому

      @@electricalautomation Thank you very much

  • @TheGreen18
    @TheGreen18 3 роки тому

    Great Videos
    Is it possible to Axis that is not from Siemens with the TO?
    For example Beckhoff?

    • @electricalautomation
      @electricalautomation  3 роки тому

      99% the Motion control and the servo drive will be the same brand. The key reason is the communication fieldbus protocol as well as the telegram. If you do have to cross the brand, most common way is to use analog output to control the drive speed and read the encoder use the encoder module.

  • @marcshiftsolve2947
    @marcshiftsolve2947 Рік тому

    Is it possible to use s7-1200 cpu instead of s7-1500 cpu's? and as well as to use stepper motor rather than servo motor?

    • @electricalautomation
      @electricalautomation  Рік тому

      You can view the video, it is using the DC motor, but the idea is the similar MS04a. Setup Positioning Axis via Analog Output, DC Motor, and Encoder
      ua-cam.com/video/Od4cqjMst4Q/v-deo.html
      MS04b. Program DC Motor Positioning Control via S7-1200 and TIA Portal
      ua-cam.com/video/WNVbgi67HfQ/v-deo.html

  • @michalkall9206
    @michalkall9206 Рік тому

    Hello, I cant see in my TIA portal option for Virtual Axis, u know where can be problem?

    • @electricalautomation
      @electricalautomation  Рік тому

      Are you using S7-1500 PLC? Which revision of TIA Portal are you using? I assume you are using S7-1200 PLC or old revision of TIA, they don't support virtual axis.

  • @EngOmar-kz9qv
    @EngOmar-kz9qv 3 роки тому

    Thank you very much for your effort .
    in simotion scout i was using _LineModule_Control function block to enable 36KW SLM infeed but now i am using TIA PORTAL V13 and i don't found this function block .
    Please how can i find and using this function block ? .
    Regards

    • @electricalautomation
      @electricalautomation  3 роки тому +1

      Simotion is different system comparing with T-CPU or S7-1500T. In TIA Portal, power up a Axis need to use "MC_Power"

    • @EngOmar-kz9qv
      @EngOmar-kz9qv 3 роки тому

      @@electricalautomation
      if i want to enable 36KW smart line infeed, also i have to use
      MC_Power ?

    • @electricalautomation
      @electricalautomation  3 роки тому

      @@EngOmar-kz9qv No, sorry, MC_Power is used to power up axis. For the Smart Line Infeed enable, maybe search "xx Infeed xx" FB, the "Linemodule" may be changed to "infeed"