AR45 Gas Roof Pump Proportioner Build

Поділитися
Вставка
  • Опубліковано 1 січ 2025

КОМЕНТАРІ • 116

  • @northjerseykevin409
    @northjerseykevin409 6 місяців тому +1

    You said ” don’t over think it”. It’s such a valid point. This might sound crazy but I’ve been stuck in my tracks at times from over thinking some things. Something is better than nothing.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  6 місяців тому

      I have over thought a lot of decision when building my equipment. After it was all done, most of it did not matter LOL. A little common sense & the plan will come together. Thanks

  • @TheFreshRinse
    @TheFreshRinse Рік тому +1

    Great bideo. Thank you

  • @tonyvalentine5177
    @tonyvalentine5177 3 роки тому +1

    Looking good! Nice job.

  • @nifproptyltd7418
    @nifproptyltd7418 Рік тому +1

    Thanks for sharing. How do you do about rinsing the chemical value when it's below your check value? Maybe I'm missing something with the remote rinse? The soap value you have above the check value so can see that water could be rinsed into the soap value and stops at the check value.

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Рік тому

      When I switch it to H2O, it rinses the SH metering valve. I have since put a manual 3-way to be able to rinse the electric valve as well. Thanks

  • @bluerainpressurewashing6190
    @bluerainpressurewashing6190 2 роки тому

    Get the cheese baby. I’m serious about coming over your way McGuyver.. thanks for all you do bro. My downstream remote still going strong after a year.

  • @adam_sings
    @adam_sings 3 роки тому +1

    Looks great. Very solid!

  • @alhydrowash9989
    @alhydrowash9989 3 роки тому +1

    Love your videos

  • @palmtree8604
    @palmtree8604 3 роки тому

    Welcome to the big leagues 👍. Marvelous simply marvelous. 🧀🧀

  • @garygodby9995
    @garygodby9995 3 роки тому

    Looks really good 👍

  • @drowization
    @drowization 8 місяців тому +1

    Where did you get the remote diverter at please ???? thank you....

  • @blakeengland7784
    @blakeengland7784 Рік тому +1

    Can you tell me why you built it this way? I need to build a system fairly quickly and looks like I need some help

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Рік тому

      There is no particular reason. I just built it to work for us. Thanks

    • @blakeengland7784
      @blakeengland7784 Рік тому

      ​@@allproexteriorservicesllc5338sorry I guess what I'm asking is, how many GPM does that run? did you get a AR45 and I'm only wondering if you can get me in contact with whoever you got your system and manifold from or I could learn some simple stuff from you

  • @Doinitmyway
    @Doinitmyway 3 роки тому

    Very Nice Job. Easy Cheese with that setup for sure.

  • @topshopmn
    @topshopmn 3 роки тому +1

    Thanks great info, where do i get remote and SH electric valve

  • @crystalclearwindowsllc
    @crystalclearwindowsllc Рік тому

    have you ever come across your bypass knob getting stuck I did I had to take it apart to release it

  • @andresolivieri3145
    @andresolivieri3145 3 роки тому +2

    Happy New year, borther! Thank you for sharing. Can I ask you where to get the part attached to the 3 way? Thanks in advance. I am tryinf to build my own. Selenoid, I already have it

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      Happy New Year!! I am not sure what part you are referring to. I have another video with the links for this build. Thanks

  • @premierpowerwashing6634
    @premierpowerwashing6634 2 роки тому +1

    Still running the 1/2" check valve instead of a 1" check valve?
    Building my AR currently. Needed to get these parts for the proportioner next.
    Thanks for the previous video outlining the parts.

  • @seattleprowash5464
    @seattleprowash5464 Рік тому

    what hose do you use to go from the machine to the reel?

  • @sundown798
    @sundown798 3 роки тому +4

    Well done man! Do you also use a high pressure bypass electric valve like a Flow Pro for down streaming?

  • @jasontenney2786
    @jasontenney2786 Рік тому

    Great video want to duplicate this u have parts list

  • @fredfano3738
    @fredfano3738 2 роки тому

    Where did you find the manifold and remote controller

  • @dcsc4895
    @dcsc4895 2 роки тому +1

    I see youre using the same brand of remote on your downstream injector setup , does the remote from one system interfere with the other system? Like if I hit on , on one remote, does it turn on both units? kinda confused how that works , thanks g

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      DC, I have never has an issue with interference. But my remote box for down streaming has a power switch and stay in the off position until I need it. Thanks

  • @mikem6197
    @mikem6197 2 роки тому +1

    You think it’s fine to go with the regular 1” ball valve for this instead of matching the 1” metering valve. I know on 12v manifolds some people say to use the metering valve on the water so it’s consistent. You think that’s the same with gas roof pump or has it been a non-issue for you? Thanks for all your help

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      I think a 1" metering valve on the water would allow you to dial it in more accurately because you know it is equal. I am think ing about changing mine for testing purposes. Thanks

  • @reidfamily67
    @reidfamily67 2 роки тому +1

    If you dont mind me asking where did you get the 4 way manifold and 3 way valve

  • @2bParagon
    @2bParagon 3 роки тому +1

    New to gas roof pumps, why does the bypass go to the manifold instead of back to the water tank?

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      The bypass keeps circulating to not put chemicals back in my tanks. If I was batch mixing, then I would run the bypass hose back to the tank. Thanks

    • @2bParagon
      @2bParagon 3 роки тому +1

      @@allproexteriorservicesllc5338 well duh, don't I feel stupid, I'm living in the high pressure world, So that didn't cross my mind

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      @@2bParagon All good brother!! I had to figure it out as well. Thanks

  • @jaxxo5
    @jaxxo5 2 роки тому +1

    How do wire up the 3 way valve?

  • @TheMhowi007
    @TheMhowi007 3 роки тому +2

    What's up bud you got the link for the 1/4 solenoid

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      Here you go. Thanks ussolid.com/account.php?action=view_order&order_id=170023275

    • @TheMhowi007
      @TheMhowi007 3 роки тому +1

      @@allproexteriorservicesllc5338 you the man I basically copy all your builds appreciate all the help haply holidays to you and yours

    • @ktpowerwashing
      @ktpowerwashing 3 роки тому

      Link not working

    • @TheMhowi007
      @TheMhowi007 3 роки тому

      @@ktpowerwashing hey Kev I noticed that earlier but just click on the solenoid 1/4" valves there's a lot to choose from hope that helps

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      @@TheMhowi007 Happy Holidays to you & yours as well!!

  • @Unsilentmajority-1
    @Unsilentmajority-1 3 роки тому +1

    You just use black paint for the piece of wood or flex spray?

  • @dontetolbert2825
    @dontetolbert2825 Рік тому

    How much you charge to build a 1 inch proportioner for ar60 gas roof pump

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  Рік тому

      I have not had time to do any building and parts are still tough to find. I think Leon Johns & a few other people are still building them. Thanks

  • @tonysmith4908
    @tonysmith4908 10 місяців тому +1

    Dumb question man can you tell me the names of the pieces and were you bought them from

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  10 місяців тому

      The main parts is the manifold & metering valves. The barb fittings & hose are simple to get. There are a few companies online that build the manifolds. Hope this helps. thanks

  • @littlespressurewashing
    @littlespressurewashing 3 роки тому +2

    Sweet 🔥

  • @Daniel_Morrobel
    @Daniel_Morrobel 2 роки тому +1

    Nice video and setup, how long do you have to make the bypass hose and how is the ar 45 pump holding up?

  • @jessieramirez7782
    @jessieramirez7782 2 роки тому +1

    Awesome video!!!
    Question: are all the ports on the manifold 1”? Or is the Bypass one size, Water/Chem ports different size, Soap 1&2 ports different size and the pump port different as well? Thanks for the clarification

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому +2

      All ports are 1" except the soap ports which are 1/2". I use a 1" to 3/4" barb for the bypass. Thanks

  • @joseluis8573
    @joseluis8573 3 роки тому +1

    Very very nice man
    For what do u use the selenoide?

  • @michaelkendrick7738
    @michaelkendrick7738 2 роки тому +1

    Where did you buy the horizontal block at the top of the valves?

  • @joseluis8573
    @joseluis8573 2 роки тому +1

    Hi Sir,what size of battery wire do you use for ar45 proportioner?
    Thanks bro,i appreciate 👍🏻

  • @keithbarnett5245
    @keithbarnett5245 3 роки тому +1

    I just got an AR45. I heard that they aren’t designed to run off a proportion with a looping bypass. They are saying that the pressure builds up in that bypass line and it’s got nowhere to go amd heats up the manifold.
    What is your experience?

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому +1

      So far no problems. I believe that is why they recommend 25" bypass hose to help cool it down. Thanks

    • @keithbarnett5245
      @keithbarnett5245 3 роки тому

      @@allproexteriorservicesllc5338 I suppose if you treat it like a pressure washer and don’t leave the gun closed for too long should be ok.
      When you crank it up just blow and go and don’t stop!!!

  • @edsweet2908
    @edsweet2908 3 роки тому +1

    did you make your own proportioner block

    • @sundown798
      @sundown798 3 роки тому +2

      Midwest makes simmilar blocks like this. Nice quality indeed.

    • @JUAN120484
      @JUAN120484 3 роки тому +1

      What size the small black box if you got info a will appreciate

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому +1

      @@JUAN120484 This is the box I used. www.amazon.com/gp/product/B07WS4X1ZQ/ref=ppx_yo_dt_b_asin_title_o07_s00?ie=UTF8&psc=1

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  3 роки тому

      No, I got it from Jason Tippett. You can look him up on the FB groups. It is very nice quality. Thanks

    • @JUAN120484
      @JUAN120484 3 роки тому +1

      You can get the block in nylon on Amazon them take to laser machine make it the holes

  • @dcsc4895
    @dcsc4895 2 роки тому

    My new fav channel.. Would this handle the 11gpm/300psi comet p40? Also, do you really need the expensive metering valve on the soap line? or

  • @raymondwright3876
    @raymondwright3876 6 місяців тому +1

    What happened to your boss? I don’t see on UA-cam. No more damn I missed it.

  • @GoldenState408
    @GoldenState408 2 роки тому +1

    what size are your connections Bro?

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому +2

      1" on h20 & sh. Then 1/2" on soap. Thanks

    • @GoldenState408
      @GoldenState408 2 роки тому

      @@allproexteriorservicesllc5338 how about the softwash hose? what size do you use? THANKS BROTHAAAA appreciate the response love your vids btw and manifold build legit

    • @allproexteriorservicesllc5338
      @allproexteriorservicesllc5338  2 роки тому

      @@GoldenState408 thanks again!! I am running 1/2" hose on my reel.

  • @tylers8195
    @tylers8195 2 роки тому +1

    What valves are you using?

  • @edsweet2908
    @edsweet2908 3 роки тому +3

    do you have the name of the person on facebook that makes your proportioner block i like to have one made

  • @wlcpowerwashing4127
    @wlcpowerwashing4127 2 роки тому +1

    How much....I need one

  • @chasebuerger3430
    @chasebuerger3430 3 роки тому +1

    Just put a 1in banjo Y filter before the three way valve, easier to clean and check.

  • @prestigepropertywashing
    @prestigepropertywashing Рік тому

    yessir

  • @crystalclearwindowsllc
    @crystalclearwindowsllc Рік тому

    Parts list

  • @Unsilentmajority-1
    @Unsilentmajority-1 3 роки тому

    First!!!