Refrigeration.Is Frosting on suction pipe normal?? ?|RMETC| Ramesh

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 47

  • @imunoteshelp255
    @imunoteshelp255 23 дні тому

    Thankyou sir🎉 for sharing simple and easy to understand videos

  • @srinivasanthayyil4836
    @srinivasanthayyil4836 4 роки тому +4

    Very complex situation explained nicely. Should have included how to achieve desirable superheat, and which one controls the superheat. Hope have more videos like this.

    • @rmetcvideos
      @rmetcvideos  4 роки тому +5

      Thanks sir..will do...just trying to keep videos short...This is the age of TIKTOK..😀😀

  • @anandsagar9132
    @anandsagar9132 2 роки тому +1

    Excellent explanation sir... Thankyou Very much Sir.

  • @mdaburaihan4650
    @mdaburaihan4650 Рік тому

    Sir I like your videos so much. I have learnt lot from you. Please upload more videos so that we can learn more

  • @shashanktantri
    @shashanktantri 4 роки тому

    Well explained sir !! Waiting for ur next vdo ,with explanation of wat really is happening here.

  • @shankaranand1139
    @shankaranand1139 3 роки тому

    Sir your videos are exceptional.....❤❤❤❤...sir please make more videos..

  • @wildernessbliss7021
    @wildernessbliss7021 3 роки тому +1

    sir the is video is total knowledge oriented and one more things the animation you made is also very innovative specially the guy who opens the door and peep and suddenly shut it seeing the ceo he must be a Junior Engineer.

  • @SanjayYadav-qu1mf
    @SanjayYadav-qu1mf 3 роки тому

    very good video sir.. hope for some more videos from this topic

  • @maaransezhiyan
    @maaransezhiyan 11 місяців тому

    Thank u so much Sir for ur effort in making us understand 😇

  • @subramoniam100
    @subramoniam100 4 роки тому

    Very good explanation... waiting for ur videos on Main Engine troubleshootings

  • @anishmandhare
    @anishmandhare 3 роки тому

    Best explanation sir, thank you.

  • @nabilhasan1689
    @nabilhasan1689 4 місяці тому

    Dear sir, i am a big fan and kind of regular viewer of your tutorial vidoes... i would say , you method of teaching and projection is tremendous and extemely helpful for us.
    kindly requesting you to make a explanation video on FRAMO cricuit diagram. i am struggling for it ...
    .
    thank you

    • @rmetcvideos
      @rmetcvideos  4 місяці тому

      understand your difficulty.To get control of Framo fundamentals there is a lot of ground to be covered in Basic Hydarulics. Try attending one of the hydraulics workshops I have started for Open market. Details at www.rmetc.co.in

  • @neyanmahizh4293
    @neyanmahizh4293 27 днів тому

    🎉 sir in reefer charging we have heat exchanger in suction of reefer compressor and evaporate outlet so how we can use the suction gauge for the refrigerant level using that suction pressure and temp

  • @shubhamtarlogta659
    @shubhamtarlogta659 2 роки тому

    Thanks for the information sir.🙏

  • @antonyzairaz7627
    @antonyzairaz7627 Рік тому

    Thank you sir.

  • @YeroleP
    @YeroleP 4 роки тому

    Very useful .. thank you sir..

  • @amaranand2871
    @amaranand2871 2 роки тому

    Nice one

  • @manishkumarprasad9588
    @manishkumarprasad9588 2 роки тому +1

    Hello sir ..pls if possible try to make videos on troubleshooting of referigerance and HVAC system, will be very helpful..

    • @rmetcvideos
      @rmetcvideos  Рік тому

      Most are already covered in the 3-4 vidoes i Made on this subject

  • @vardhaniattili4724
    @vardhaniattili4724 Рік тому

    TQ sir....

  • @ashutosh5322
    @ashutosh5322 2 роки тому

    Can't thank you enough:) sir, can you please give us knowledge about charging ref gas in the system. Please sir.

  • @adarshwarrier6281
    @adarshwarrier6281 4 роки тому +1

    Great video sir! This actually arises another doubt for me. Onboard the ship, do we have any nitrile rubber insulations surrounding the pipes? If it were present would this problem actually occur?

    • @rmetcvideos
      @rmetcvideos  4 роки тому +2

      Thanks..actually onboarding we used to have the thick glass wool type...maybe now we have other types due to health hazard.
      But as long as we have proper insulation..we cannot see this.but invariably the suction valve insulation is torn off or damaged and then you can see.again ot depends.If the surface temp is +1 we have condensation and if it is -1..we have frosting
      That is not the point.what we are discussing here is that ..if you are frosting. It is not necessary that liq is returning.My reasoning.also written on many articles

    • @adarshwarrier6281
      @adarshwarrier6281 4 роки тому +1

      @@rmetcvideos yes sir i understood the point you are trying to say here, it was just something which came up in my mind!Thank you for videos sir! The animations and explanations have been great to understand! Looking forward to more of your videos! 😊

  • @sanjayjaiswal9158
    @sanjayjaiswal9158 5 місяців тому

    Sir please explain hydraulic drawing of deck crane hydraulic system.

    • @rmetcvideos
      @rmetcvideos  5 місяців тому

      Deck cranes are quite complicated and there are many many types of cranes. None of themn are similar from hydraulic point of view.Even the working principle and concepts vary.Having said that I had some course content on Deck Cranes for Merchant Navy Decoded
      courses.merchantnavydecoded.com/learn/Introduction-to-Ships-Cranes . You can check it out here if youn may like. Quite a lot of info over there dealing with the topic in a generic manner

  • @naylinhan5795
    @naylinhan5795 2 роки тому

    Thank a lot SIR, my conclusion is , it is OK' icing on the suction line of refer system ( if good insulation and compressor is running there may be no ice)
    But it is NOT OK icing on the suction line or on the evaporator of Air con system because temperature of refrigerant in the suction line is above the freezing point of water in the air. is it correct ? SIR.... thank you

  • @vinu00012
    @vinu00012 3 роки тому

    🙏🙏🙏🙏thanks a lot sir.

  • @cihat0638
    @cihat0638 2 роки тому

    Thanks Sir. İt was excellent and very kind from you. But maybe I missed, i need a solution now, have can I prevent the condensing (freeze) on suction pipe? Please let me know .thank you

    • @andoapata2216
      @andoapata2216 Рік тому

      if you have freezing in suction line, thermostatic valve is malfunctioning or badly set up , because it should close when the bulb senses low temp

  • @shubhendravikramsingh9986
    @shubhendravikramsingh9986 3 роки тому +1

    great video sir , but now i am confused . according this there could be ice on suction line , even if the liquid is not returning because gas which is returning is also at -20 degree.. but on my ship icing never happened so is that mean that returning gas was having positive temperature. so suction pressure be above 4.5 bar accoring to chart which is also not true as per the gauge i had.. sir this may be a silly doubt but please help me..

    • @rmetcvideos
      @rmetcvideos  3 роки тому +3

      Icing is not a must.. It is very complicated.The gas still will be in minus if there is no problem, But ICING will depend upon the activites near the vicinity, like hot equipments like Compressore cut in ..ER Blowers etc which may NOT allow icing to happen.So the Best conclusion is, that if ICING happens it is not NECESSARY that liq is returning.

  • @mikhailcho4287
    @mikhailcho4287 3 роки тому +1

    Water should not be presented in the refrigeration system, so that the compressor will not break. Am I on the right track?

    • @rmetcvideos
      @rmetcvideos  3 роки тому +5

      If you have water it will freeze in the Expansion valve and the compressor will trip on LP...Water shuld not be entering into suction side of compressor unless the Expansion valve is complete broken or something

  • @geenumaxy9370
    @geenumaxy9370 3 роки тому

    geat

  • @akshaybehera8196
    @akshaybehera8196 4 роки тому +1

    This pyare joke is very nice

  • @mohammadaslam9100
    @mohammadaslam9100 3 роки тому

    🙏🙏🙏

  • @giridharannedumaran6389
    @giridharannedumaran6389 4 роки тому +1

    Sir, can u please explain about charging freon in refer compressor

    • @rmetcvideos
      @rmetcvideos  4 роки тому +7

      Charging can be done in two ways. Gas or liquid. Gas is charged at Suction inlet and Liquid id charged at Condenser or receive outlet before the Dryer.

  • @prajjwalbhandari157
    @prajjwalbhandari157 11 місяців тому

    confused

  • @AmitKumar-ic6dd
    @AmitKumar-ic6dd Рік тому

    Sab bta Diya par answer nahi btaya 😂

    • @rmetcvideos
      @rmetcvideos  Рік тому

      Arre bhai....answer bataya na...answer is....IT IS NOT ABNORMAL🤣🤣

    • @masterchiefcode117
      @masterchiefcode117 Місяць тому

      if you would have understood it, then you wouldn't be asking for an aswer.