  • Pulling a vacuum is a common part of air conditioning repairs. Vacuums are used to evacuate ACs, a process by which they pull out all air and moisture from the refrigerant system prior to testing, repairs, and recharging. Generally, this is best done by an HVAC professional.
    An air conditioning vacuum pump is used to remove unwanted air and water vapor from the air conditioning system when it is under service. When the air conditioner needs to be repaired, the first step taken is usually to recover the refrigerant from the system for reuse later.
    Once the recovery job has been done, you can now proceed to do the necessary troubleshooting and repair work. The next step is to check and make sure that the system is leak-free else steps will have to be taken to rectify this.
    The evacuation process is the next step in which the vacuum pump is used to remove the air and moisture from the refrigerant system. Once this is done, the charging process can be carried out before doing a full test on the system.
    #ECDIAL
    #ECDIAL_AC
    #ECDIAL_VACCUM
    AC SERVICE IN TAMIL:
    • AC SERVICE IN TAMIL | ...
    HOW TO REDUCE THE CURRENT BILL IN AC IN TAMIL:
    • HOW TO REDUCE THE CURR...
    INVERTER AC VS NON-INVERTER AC IN TAMIL:
    • INVERTER AC VS NON INV...
    INVERTER AC VS NON-INVERTER AC MAINTENANCE:
    • INVERTER AC & NON INV...
    CAN WE USE AC & CEILING FAN TOGETHER IN TAMIL:
    • Can we use AC and ceil...
    AC GAS LEAKS:
    • AIR CONDITIONER GAS LE...
    STAR RATING/AC BUYING GUIDE/ INVERTER AC NON- INVERTER AC:
    • Star Rating | AC Buyi...
    HOW TO SAVE ELECTRICITY AT HOME:
    • How to save electricit...
    POWER SAVING TIPS IN HOME APPLIANCES:
    • Power saving tips in h...
    HOW TO MAKE A PROPER WIRE JOINT:
    • How to make a proper w...
    Do Like and share it as much as you can in all your Facebook and WhatsApp groups for other people's help too.
    Instagram Link: / ecdial
    Facebook Link: / ecdial
    Blog: ecdial.blogspot.com
    Whatsapp only: 8428118111 (10AM-5PM)
    Whatsapp Group link: chat.whatsapp....
    Responsibility Disposal
    This video including examples, images, and references are provided for informational and educational purposes only. The names of actual companies and product mentions herein may be the trademarks of their respective owners. Credits shall be given to the images taken from the open source.
    Advice, graphics, images and information contained in this channel is presented for general information and to increase overall safety awareness.
    The above scenarios and illustrations are done by a good handful of technicians People need to do good training and consult a technician before doing this, otherwise they should not do such work.
    Note:
    The power supply must be turned off before all such technical work can begin.

КОМЕНТАРІ • 172

  • @Ecdial
    @Ecdial  3 роки тому +1

    For more information follow us on,
    Instagram Link: instagram.com/ecdial/
    Facebook Link: facebook.com/ecdial

    • @suresh-vc7yq
      @suresh-vc7yq Рік тому

      12/01/2023 than new non inverter acvacuum poda assamble pannanga sir, nanga one hour use pannom sir ,ippo vacuum poda mudiyuma ,appadi illana ethavathu problem varuma sir ac la,

    • @Ecdial
      @Ecdial  Рік тому

      Sir I can't understand

    • @krishnaG-kg9dt
      @krishnaG-kg9dt Рік тому

      In inverter AC the outdoor unit is mild current shock, if i keep tester on outdoor unit light in glowing in tester is normal?
      Ground connection are good it shows around 5 volt while testing ground and netural in multimeter

  • @vellingirisamya1154
    @vellingirisamya1154 3 місяці тому +2

    Very useful video. Keep it up. Wish you all the best.

  • @haribabuparasuraman8789
    @haribabuparasuraman8789 3 роки тому +3

    உண்மை சொல்லும் உங்களுக்கு மனமார்ந்த நன்றி மற்றும் வாழ்த்துக்கள் ....

  • @kandhasamyp5613
    @kandhasamyp5613 2 місяці тому

    Sir i salutes to ur valuble suggestion. 🙏🙏🙏

  • @azadazad1121
    @azadazad1121 4 роки тому +1

    Super bro நல்ல தகவல். தெள்ள தெளிவாக technicianghalukkum, matravargalukkum puriya vaithatarkku nandri.

  • @kanniyappanbilla85
    @kanniyappanbilla85 4 роки тому +2

    👏👏👏👏👏👏👌 அருமையான விளக்கம் சகோதரரே வாழ்த்துக்கள்🙏

  • @Raghavendran_Nadar
    @Raghavendran_Nadar 3 місяці тому +1

    Thanks brother, very useful information god bless you ❤

  • @air-condigitals2409
    @air-condigitals2409 4 роки тому +6

    Thank you very much for giving us this valuable content

    • @zenoraj461
      @zenoraj461 4 роки тому +1

      very useful alert message thank you sir

  • @saravanakumar301
    @saravanakumar301 4 роки тому +10

    அப்படியே கட்டாயபடுத்தி வேக்கம் போட சொன்னாலும் proper vacum panna matakiranga fridge compressor vachi poduranga athuku vacum panrathum onuthan podam parathum onuthan

  • @rajmugam1
    @rajmugam1 3 роки тому +2

    மிக அருமையான பதிவு.

  • @KAVItheKING
    @KAVItheKING 4 роки тому +3

    Yes bro you are true, vaccum pump vanganum, apram 30min wait pananaum, andha time la next customer attend pana polam nu niriya per vaccum poda matenguranga. But sila per name ketupoidum apram work clearah irukanum nu regular ah kupduvanganu nu seyrunga.

  • @aravindasamym2762
    @aravindasamym2762 4 роки тому +3

    I'm support Ec Dial

  • @SANTAMILGammy
    @SANTAMILGammy 2 роки тому +5

    Yesterday தான் bro ac vaangunan, showroom la ye 1 ku 2 thadava sollitan... Instalation panna varavenga ta vaccum panna sollunga nu, nallavela... Today vaccum panni install pannitanga.

    • @Ecdial
      @Ecdial  2 роки тому +2

      Super bro

  • @baranirajan7293
    @baranirajan7293 Рік тому +2

    R-32 gas உள்ள 2023 மாடல் non inverter 1 டண் Daikin A/C க்கு புதுசா installation அன்று vacuum போடனுமா Bro.
    Please reply.

  • @sureshr3732
    @sureshr3732 5 місяців тому +2

    எங்க வீட்ல daikin ac இப்போ ரீசண்டா gas 140 க்கு 50 இருக்கு gas Fill top up பண்ணாரு வேக்கம் போடல ஆனா இப்ப யூஸ் பண்ணும் போது முன்னாடி இருந்ததை விட கூலிங் ரொம்ப கம்மியா வருது அந்த கம்ப்ரசர் ஃபேன்ல வந்து ஹீட்டா வரும் காத்து ஆனா இப்ப அந்த காத்து ஹீட்டா வரல அது பற்றி அந்த மெக்கானிக் கிட்ட கேட்டதுக்கு அப்படித்தான் இருக்கு எல்லாம் கரெக்ட் தான் இருக்குன்னு சொல்றாரு இதை சரி பண்ண நான் என்ன பண்ணனும் கொஞ்சம் ஆலோசனை சொல்லுங்க சார்

  • @anandhans5846
    @anandhans5846 4 роки тому +8

    போன மாதம்தான் AC வாங்கினோம்.
    Vacum நமது ACல் இருக்கிறதா இல்லையா என்பதை எப்படி தெரிந்து கொள்வது?

    • @JohnJohn-wj4fc
      @JohnJohn-wj4fc 2 роки тому

      Install pannuna technician kitta kelunga

  • @ommuruga786
    @ommuruga786 4 роки тому

    மிகவும் அழகான பதிவு நன்றி 🙏

  • @ThinkBigVfx
    @ThinkBigVfx 4 роки тому +1

    Hi sir I installed inverter AC two year back and 10 months before i shifted my house i also installed it for the second time and no one used vacuum. now, what can I do?

  • @gokuls7999
    @gokuls7999 Рік тому +1

    Hi sir
    R22 gas A/C- now available in market

  • @irsathahamed.b8753
    @irsathahamed.b8753 4 роки тому +1

    Gd speach gd information thanks bro😊

  • @gshankargurusamy7612
    @gshankargurusamy7612 4 роки тому

    Hi bro semma itha thaan naan ethir paarthen

  • @PraveenKumar-cj4mu
    @PraveenKumar-cj4mu 4 роки тому +2

    God bless you 🙏❣️

  • @kalaiselvam3023
    @kalaiselvam3023 4 роки тому +2

    Okay bro, ac technician vacom poturanu sollikiru summa mattivachikitu irunthal nama yeppadi kandu pitikiratu bro

    • @Ecdial
      @Ecdial  4 роки тому

      Check the meter reading bro.

  • @jayaprakashbabu8420
    @jayaprakashbabu8420 4 роки тому +1

    Bro, in my split AC 1.5ton,very often the discharge as an ice formation.i checked with 3 mechanic, in that the first one said the indoor unit u tube as got leak and he says d he as welded. And at the time of installing he suddenly said the compr essor is not working. So I called the 2 mechanic he made the compressor run with is technique of work, but he didn't close the net in the discharge properly so again ice formation.And he said the indoor unit as to be changed. Finally I called the another mechanic and this guy checked with pressure compressor and said everything is fine, and he found out there was a leak at the discharge tube small copper line net. So he again filled the gas and the ac was running good for 20 days, and again there is ice formation in the discharge line. I am really fedup of the same issue again and again. Bro can you solve my issue .

  • @vigneshkumar2566
    @vigneshkumar2566 2 роки тому +1

    Bro shortage gasku vacuum podanuma

  • @rharinath77
    @rharinath77 3 місяці тому

    Boss ..why are you not doing service work in chennai location

  • @baarathcoolers6243
    @baarathcoolers6243 4 роки тому +2

    Sir romba nalla pesarenga neenga vacuum panni ac install panna enna charge panarenga and 1ton 1.5 ton 2ton ac ikku r32 and r410 gas vacuum pottu full charging panna enna charges pannarenganu solla mudiumaa yeana oru oru mechanickum oru oru charges solaranga neenga unga rateta sollunga athu ella costumers ikkum usefullaa irukum mechanicikkum usefulla irukum

  • @karkuzhali9046
    @karkuzhali9046 4 роки тому

    அருமை

  • @yuvanesh43
    @yuvanesh43 4 роки тому +2

    Super bro
    Iam using haier dc inverter ac
    R-32 GAS VANGI 2 MONTHS AYIRUCHU BUT TECHNICIAN VACUUM PODALA BRO

    • @rahmanali1531
      @rahmanali1531 4 роки тому

      I am also bro i bought loyd1.5 ton ac 1 month before

    • @arungiri8846
      @arungiri8846 4 роки тому +3

      Pls put a mail to the company mail address

    • @gobinathgobinath7564
      @gobinathgobinath7564 4 роки тому +5

      Gas full ah remove pannitu vacuum pottu new gas refill pannuga
      2000 to 3500/- aagum...

    • @yuvanesh43
      @yuvanesh43 4 роки тому

      @@gobinathgobinath7564 best ac gas edhu bro iam using R-32 vacuum podala but vagi 2 month aguthu

  • @bharudayscooking
    @bharudayscooking 3 роки тому

    Super sir thanks 👍

  • @sebastinidhayaraja3871
    @sebastinidhayaraja3871 4 роки тому

    Thanks brother.

  • @thorveymohan
    @thorveymohan 2 роки тому

    THANKS .

  • @nathankodai6802
    @nathankodai6802 4 роки тому +2

    Bro, ஏசியில் என்ன வகை Gas உள்ளது என எப்படி கண்டுபிடிப்பது என விளக்கம் தேவை

  • @goodgkrl6204
    @goodgkrl6204 2 роки тому +1

    Self vacame how to yous

  • @jayakumarmahadevan6898
    @jayakumarmahadevan6898 3 роки тому

    Hi bro,
    Kindly share which airconditioner is best (inverter or non invertor)

  • @sureshv55
    @sureshv55 4 роки тому

    Very informative to be Alert

  • @arjunshivakathiravan2689
    @arjunshivakathiravan2689 4 роки тому

    Thanks bro

  • @jayaseenu105
    @jayaseenu105 4 роки тому

    Thank you sir

  • @jstudio1126
    @jstudio1126 4 роки тому +1

    Gas check pannalum podnuma bro

  • @plusorminus6517
    @plusorminus6517 3 місяці тому

    En vacuum process ku 30 mins aaguthu ?

  • @ummarnadubail
    @ummarnadubail 4 роки тому

    thanks sir..

  • @venkatvenkatesh5442
    @venkatvenkatesh5442 4 роки тому

    Thanks anna 🙏🙏🙏🙏🙏

  • @satheeshkumar.d3381
    @satheeshkumar.d3381 4 роки тому

    நல்ல விளக்கம் நன்றி

  • @johnrajuk1769
    @johnrajuk1769 4 роки тому

    Super 👌👌👍

  • @Rocky-jc8sp
    @Rocky-jc8sp Рік тому

    Nan Ac vangalam nu iruken unga kita Elam model um irukka epdi buy panrathu then EMI option irukka sollunga Sunday vangalam nu eruken

  • @sm7096
    @sm7096 3 роки тому

    Good heart u r

  • @sathishr6052
    @sathishr6052 3 роки тому +1

    lg new ac bro instal panni 2 days tha aaguthu 10*15 room size cooling a agala bro eno thano nu fit pannitu pooitaga

    • @Ecdial
      @Ecdial  3 роки тому

      Where you bought it bro?

    • @sathishr6052
      @sathishr6052 3 роки тому

      @@Ecdial vasanth and co bro

    • @Gokul_Rithik
      @Gokul_Rithik 3 роки тому

      @@sathishr6052 epo cooling agudha bro?

  • @sathyaramachandran833
    @sathyaramachandran833 4 роки тому

    Malaysia laya erukengaa ??

  • @ananthiananthi3344
    @ananthiananthi3344 4 роки тому +1

    BRO NEENGA INSTALLATION SERVICE WITH VACCUM PANNUVEENGALA .

    • @Ecdial
      @Ecdial  4 роки тому

      Compulsory mam

  • @smartboy1806
    @smartboy1806 4 роки тому +1

    Perfect review bro 😘👍👏👏👏👏👏👏👏👏👏👏.Next live Eppo solluga 🙏

    • @Ecdial
      @Ecdial  4 роки тому +1

      This time your choice nanba 😍

    • @smartboy1806
      @smartboy1806 4 роки тому

      Next week Friday or Saturday 8.00pm to 9.30pm👍🙏

    • @Ecdial
      @Ecdial  4 роки тому +1

      Okay bro

  • @leot3796
    @leot3796 2 роки тому

    New ac out door la gas eirukum ,Gas yetuthutu vacum podanuma?

    • @Ecdial
      @Ecdial  2 роки тому

      Where you studied?

  • @mahekrishna1487
    @mahekrishna1487 2 роки тому

    Bro ac la spark varuthu bro whats the reason plz solunga

  • @jayaprakashbabu8420
    @jayaprakashbabu8420 4 роки тому

    Bro, are you from Chennai? And do you have shop in Chennai.

  • @Voiceandmicoff
    @Voiceandmicoff 4 роки тому

    Bro my name is yogaraj from kangayam unga video daily parkaranga bro Mitsubishi 1.5 ton Gk model vs jp model & Mitsubishi ac vankuna fitting panna extra evello cost varunga bro oru video podunga bro.

    • @Ecdial
      @Ecdial  4 роки тому

      Call Ecdial bro 8428118111(10am to 5pm)

  • @thirumalairewindingerode296
    @thirumalairewindingerode296 4 роки тому

    வாழ்க வளமுடன்...நண்பா

  • @dhinagarandhina5293
    @dhinagarandhina5293 2 роки тому

    SIR IS IT NECESSARY TO INSTALL VACUUM IN MY HAIER AC R32 GAS?.
    CAN I TOPUP GAS (R32), IF GAS IS LESS IN FUTURE?

    • @Ecdial
      @Ecdial  2 роки тому

      you can able to top-up R32A bro

  • @karthikarthickraj285
    @karthikarthickraj285 3 роки тому

    கேஸ் பாதி இருக்கும் போது vacuum போட முடியுமா இல்ல எல்லாம் திறந்து விட்டதுக்கப்புறம் தான் போடணுமா

  • @venky01031991
    @venky01031991 4 роки тому +1

    Ac compressor oil refill panna mudiyauma . I asked one ac technician he said in rotary compressor oil refill panna mudiyathu . Suppose oil kammiya irutha enna symptoms irukum ac la .

    • @sasitharan6038
      @sasitharan6038 4 роки тому

      First noise change aagum then..then knjm days la compressor dead aairum

    • @venky01031991
      @venky01031991 4 роки тому

      @@sasitharan6038 bro oil refill panna mudiyuma ?

    • @Ecdial
      @Ecdial  4 роки тому

      Pannalam bro

    • @venky01031991
      @venky01031991 4 роки тому

      @@Ecdial are you sure bro in rotary compressor oil refill pannalama ? Because all ac technician said panna mudiyathu replace dhan pannanum . Piston compressor la dhan oil top up pannalam sonnanga

    • @Ecdial
      @Ecdial  4 роки тому

      Pannalam bro 👍

  • @tamilpandianvlogs7228
    @tamilpandianvlogs7228 Рік тому

    கியாஸின் அளவு காட்டும் டிஸ்பிளே உள்ள A /C இருக்கிறதா ? இல்லையென்றால் ஏன் இல்லை ? அப்படிப்பட்ட A/c ஏன் உற்பத்தி செய்வதில்லை. A /C கிளீன் பண்ண 3 மாதத்திற்க்கு ஒருமுறை வருபவர் வரும்போதெல்லாம் கியாஸ் தீர்ந்து விட்டதாக கூறி 2500 ரூபாய் கியாசுக்கு தனியாக பெற்று செல்கிறார். தடுப்பது எப்படி ?

  • @learntech7932
    @learntech7932 4 роки тому +1

    22 gas க்கு vacuum அவசிமா?

  • @sivasanthanam7598
    @sivasanthanam7598 Рік тому

    👍👍

  • @divanali4207
    @divanali4207 4 роки тому

    How to do the mail

  • @arunachalamchairman8305
    @arunachalamchairman8305 4 роки тому

    Bro which was blast more percentage r32 or r41a gas?🤔🤔

  • @sridharan9737
    @sridharan9737 4 роки тому

    Semma information bro

  • @Mr_F_e_l_i_x_
    @Mr_F_e_l_i_x_ 4 роки тому

    bro ac vangi 1mnth agudhu. ipo on pana...10min la power cut off agudhu.. stabalizer la OHi nu katdhu. bt IP 210 dhn varudhu.. ac prblm ah..ela stabalizer prblm ah bro...solunga..

    • @Ecdial
      @Ecdial  4 роки тому

      Call book pannuga

    • @Mr_F_e_l_i_x_
      @Mr_F_e_l_i_x_ 4 роки тому

      @@Ecdialcal book...apdina ena bro

  • @punithajessicafiyal570
    @punithajessicafiyal570 4 роки тому

    Hi brother,
    என்னை உங்களுக்கு நியாபகம் இருக்கும்னு நினைக்கிறேன். என்னோட Hitachi AC ய vaccum போடாம install பன்னிட்டாங்க. அப்புறம் நான் ரொம்ப கஷ்டப்பட்டு AC வாங்கின கடைக்கு போன் பண்ணி நீங்க சொன்ன மாதிரி பேசுனேன்.. அவங்க first service க்கு வரும் போது செஞ்சு தர்றோம்-னு சொல்லிருக்காங்க..
    1... AC - ய use பண்ண ஆரம்பிச்சிட்டோம். இப்ப vaccum போடலாம்ல?
    2...அப்டி அவங்க service பண்ண வரும் போது vaccum போட்டா charge பண்ணுவாங்களா? எவ்வளவு ஆகும்?

  • @mrchantrumrccoolpoint5481
    @mrchantrumrccoolpoint5481 3 роки тому

    R22 R410a R32 work paniyachu

  • @karthikmsc05
    @karthikmsc05 4 роки тому

    Hi bro..as you suggested checked with technician for compressor replacement he said 13k for hitachi compressor and the leg will be altered for seating and no warranty will be pro died for that reason..
    So finally I brought a new carrier 1.5 ton non inverter model the installation people accepted to put vaccum as you have suggested 🙂

    • @karthikmsc05
      @karthikmsc05 4 роки тому

      How will carrier be bro is it good on cooling?...the outdoor unit looks very big like 2 ton model

    • @Ecdial
      @Ecdial  4 роки тому +1

      Nallaa irukkum bro

  • @devakumar4317
    @devakumar4317 4 роки тому

    Water heater review po2ga bro

  • @muthamizhan2772
    @muthamizhan2772 Рік тому

    Hi bro👌🏻

  • @SathishLKumar
    @SathishLKumar 4 роки тому

    First vacuum yendral yayna

    • @Ecdial
      @Ecdial  4 роки тому

      Check our vacuum videos bro

  • @SelvaRaj-gt3ue
    @SelvaRaj-gt3ue 2 роки тому

    வேக்கம் போடலனா ஏசி ஃபர்ஸ்ட் ஸ்டார்டிங் அப்பவே வெடிக்குமா அல்லது ஒரு வருஷம் கழிச்சு வெடிக்குமா தெளிவா விளக்கம் கூறுங்கள்

  • @bk3077
    @bk3077 4 роки тому

    Daikin 1.5 Ton 5 Star Inverter Split AC (Copper FTKF50TV White) - Bro as per my understanding & friends suggestions I bought this model, Is this a good model & how is the Build Quality & the life of the product & any suggestions for maintenance. ???

    • @supersingerrasigan5590
      @supersingerrasigan5590 2 роки тому

      As u have already bought why this question now? Will there be any use. If he tells its not great, u will only lose ur sleep😂

  • @sivashanmugam1603
    @sivashanmugam1603 Рік тому

    Super super super super super super super super super super super super super

  • @kingofusilampatti9290
    @kingofusilampatti9290 4 роки тому

    Bro 10×10 room 25000 thousand la best ac irrukka bro

    • @Ecdial
      @Ecdial  4 роки тому

      Available bro

  • @StephenA-mm1pp
    @StephenA-mm1pp 4 роки тому

    New AC la gas fulla irukum pothu epdi vacum podrathu

    • @Ecdial
      @Ecdial  4 роки тому +2

      Vacuum for indoor and indoor piping not outdoor

  • @kannadasan2539
    @kannadasan2539 2 роки тому

    👏👏👌🥰

  • @shivakumar7310
    @shivakumar7310 4 роки тому

    Sir R-32 Panasonic Invertor model 2020 ku vacuum podanuma?

    • @Ecdial
      @Ecdial  4 роки тому

      Compulsory need bro

    • @shivakumar7310
      @shivakumar7310 4 роки тому

      @@Ecdial sir...Na ac vangee 4 months aguthu...I purchased Panasonic inverter model. But when I purchase in asked about gas and vacuum..But they told ellam default ah irukum nu sonanga...But I'm having dought ellam correct ah irukumanu...How to get check with this sir? Pls help

  • @venky01031991
    @venky01031991 4 роки тому +1

    R22 Ac blast aguma bro vacuum podalana.

  • @kadershareef8999
    @kadershareef8999 Рік тому

    Wacum na ennanga

    • @Ecdial
      @Ecdial  Рік тому

      See vacuum playlist video

  • @m.venkatamirthanm.venkatam2981
    @m.venkatamirthanm.venkatam2981 2 роки тому

    Aiya samy first general service panna solluinga a/c users

  • @Endrum-Ak
    @Endrum-Ak 2 роки тому +1

    நீங்க டைடில் தகுந்த மாதிரி ,,பதில் சொல்லவே மாட்டிங்கிறிங்க

  • @MaiappanMK
    @MaiappanMK 4 місяці тому

    கம்பெனி காரங்கள் இன்ஸ்டால் செய்யும் போது வேக்குவம் போடுவது இல்லை

    • @Ecdial
      @Ecdial  4 місяці тому

      Yes 😢😢

  • @vivekvicky3497
    @vivekvicky3497 4 роки тому +2

    Vuccum poda thevalanu solranga sir company technician

  • @palanisami5474
    @palanisami5474 4 роки тому

    Vacuum அப்படி என்றால் என்ன அது எப்படி இருக்கும் தெளிவாக சொல்லூங்க

    • @Ecdial
      @Ecdial  4 роки тому

      See our vacuum videos bro

  • @ramachandran.p3958
    @ramachandran.p3958 4 роки тому

    இப்படி நீங்க சொல்றது சரிதான்.... இந்த மாதிரி ஏசி இன்ஸ்டாலேஷன் செய்தாள் ஒரு ஏசி பிட் செய்ய ஒரு

  • @arumugammugam4776
    @arumugammugam4776 2 роки тому

    Vaccum na yena

    • @Ecdial
      @Ecdial  2 роки тому

      bro pls see our vaccum play list videos

  • @n.s.swaminathan2143
    @n.s.swaminathan2143 2 роки тому

    இவன் உச்சரிப்பு சரியில்லை என்ன சொல்ல வரான்

  • @jagadeeshm9255
    @jagadeeshm9255 2 роки тому

    🤣🤣🤣

  • @ImamRasool
    @ImamRasool Місяць тому

    ப்ரோ சீசன் டைம் எல்லாம் ஒவ்வொரு ஏசி வேக்கம் போட்டு ஏத்த முடியுமா, இல்ல நீங்க டெக்னிசியன் ந இருக்கும்போது எல்லாம் ஏசி வேக்கம் போட்டுதான் ஏத்துனிங்க ல

  • @crispyking43
    @crispyking43 3 роки тому

    Vaccum na ena bro...atha soluga 🙄

    • @Ecdial
      @Ecdial  3 роки тому

      Check our vacuum playlist

    • @crispyking43
      @crispyking43 3 роки тому

      @@Ecdial done.
      . checked bro and enoda new 5 star Daikin AC ku vaccum panita 👍🏻

  • @jaghadeeps.n.7654
    @jaghadeeps.n.7654 4 роки тому

    Thanks bro