Lap Length Rules for Reinforcement Bars

Поділитися
Вставка
  • Опубліковано 24 кві 2018
  • What is lap length in Reinforcements Bars
    Lap Length formula
    Lap Length Calculation
    What is Lap Length
    What is Lap Splices
    Lap Length Formula for Columns
    Lap Length Formula for Beams
    Overlap Length Calculation in Steel Bars
    Lap Length Calculation for Bar Bending Schedule
    Development Length and Lap Length
    Whats is difference in between lap lengtj and development length
    Overlap, Lap Splices, In this video i have explained just a basic things about the bar lap length / lap splices & there technical details according to IS 456, precautions during execution of reinforcement steel works, i think this topic should be clear to all site engineers also having the details of interview questions.
    #Factualcivilengineering
    #laplength
    #laplengthFormula

КОМЕНТАРІ • 48

  • @AkhilShandilyaji
    @AkhilShandilyaji 6 років тому

    Awesome video... Best knowledge centre on UA-cam thanks sir for helping people out

  • @praveensingh6279
    @praveensingh6279 6 років тому

    Good detail for interview, thanks sir

  • @shreeniwaspandey2099
    @shreeniwaspandey2099 6 років тому

    Good detail, thanks sir, it will help for interview questions

  • @srisidhu5329
    @srisidhu5329 5 років тому

    Helpful video for site engineers.

  • @lovefirstvoice8768
    @lovefirstvoice8768 5 років тому

    Very good & complete information , I like your channel keep upload more sir. ,,☺☺

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 5 років тому

    Excellent video sir. thnx a lot.

  • @SorabhporbalPorwal
    @SorabhporbalPorwal 5 років тому

    Apki sari video jabardast h,

  • @VinayKumar-jq5yd
    @VinayKumar-jq5yd 5 років тому

    Good detail sir

  • @vinodr.prasad9069
    @vinodr.prasad9069 5 років тому

    Very good sir thank you

  • @parveenkumarsharma9233
    @parveenkumarsharma9233 5 років тому

    Good detail for interview. Thanks please make a video on lap zone in beams & columns

  • @miteshparmar2015
    @miteshparmar2015 2 роки тому

    Narayan Bless You 🙏

  • @deepakghole2017
    @deepakghole2017 5 років тому

    thanks sir

  • @ashutoshkumar7969
    @ashutoshkumar7969 3 роки тому

    Plz make a video on cover depending on exposure conditions

  • @vinaymishra8880
    @vinaymishra8880 Рік тому

    If lapping higher dia lap in lower dia in column then which dia is cosiderable

  • @jawaharchauhan2551
    @jawaharchauhan2551 6 років тому +3

    Awesome knowledge u have sir...Please make some videos also related how to read slab reinforcement

    • @FactualCivilEngineering
      @FactualCivilEngineering  6 років тому +1

      hi jawahar chauhan, there are lot of structural agencies & they have diff.concept of drawings pertain to their design. i will make a video on basic points, of slab reinforcement steel. Thanks for your support

    • @jawaharchauhan2551
      @jawaharchauhan2551 6 років тому

      Thanks sir .....Only two channel video I like ...First is u and other is l&t.....I have a slab reinforcement drawing how can I send this drawing pick ...If u will be explain this drawing I will thankful to u sir

    • @FactualCivilEngineering
      @FactualCivilEngineering  6 років тому

      fwd @ amit.ggn277@gmail.com

    • @jawaharchauhan2551
      @jawaharchauhan2551 6 років тому

      Thanks sir

    • @jawaharchauhan2551
      @jawaharchauhan2551 6 років тому

      Sir have u got slab reinforcement drawings

  • @imranwali5973
    @imranwali5973 4 роки тому

    If the floor height is 3.6m and bar is 32mm and beam depth is 900mm then... Will 1.3 times of 50D is effective, Because lap will cross the bottom bar of beam....?

  • @CivilAddaa
    @CivilAddaa 4 роки тому

    In lapping of bars in column which bar should be tilt, top bar or bottom bar...which one is correct???

  • @AdityaSingh.....
    @AdityaSingh..... 2 роки тому

    सर हमारे घर के contractor ने सभी columns में 12mm का सरिया use किया है बस 2 column ऐसे है जिनमे 4 T10 mm का सरिया लगा है, इन दो columns के बीच में दुरी 5ft की है, अभी सारे columns का construction plinth level तक ही हुआ है, कृपया मुझे बताये क्या में foundation से आती हुयी इन दो columns की 10mm की सरिया को T12mm की सरिया से overlap कर सकता हूँ क्या?? 🙏

  • @subhranil5
    @subhranil5 4 роки тому

    Tell me where I will find the lap lenght for different size of bars and concrete in IS456?

  • @structuredesign5669
    @structuredesign5669 4 роки тому +2

    Good morning sir,
    Sir, I want to become professional engineer like you . I am doing job in Noida but my senior don't tell me technical point. They all are doing only labour management, I am also that's why I am leaving my job. I think so this is not a engineering. This is called supervising.

    • @naturelove583
      @naturelove583 3 роки тому

      Brother mujhe v job dilwa do..in delhi ncr

    • @speedyfalcon945
      @speedyfalcon945 3 роки тому

      Untill you got new better job, you don't leave job.
      Keep searching.........

  • @sanuscorner8258
    @sanuscorner8258 5 років тому +1

    Sir plz make one video on cover topic as per Is code

    • @FactualCivilEngineering
      @FactualCivilEngineering  5 років тому

      Sure i will upload soon,

    • @anwaraziz5585
      @anwaraziz5585 3 роки тому

      @@FactualCivilEngineering today got the answer that why we take lesser dia of bar in lap length,,may nay bohat search kiya ta ye reason mgr kahi b nahi mila ta,,so as laod is transfer from lesser dia of bar to higher dia of bar thats why we take lap length of lesser dia of bar

    • @anwaraziz5585
      @anwaraziz5585 3 роки тому

      @@FactualCivilEngineering why this 6d bend is provided?technical reason hy iska koi dear sir

  • @yadavharsh2578
    @yadavharsh2578 5 років тому

    Sir 36 mm is also consider in build or above 36

  • @Godis1andimageless
    @Godis1andimageless 6 років тому

    Gulf mein kaunse standards follow karne padenge....can u plz share

    • @FactualCivilEngineering
      @FactualCivilEngineering  6 років тому

      Mohammed ziauddin ahmed , first things is in gulf countiries all projects has world class facicilties & high end technology, so they mostely follow ASTM / British Standrads also the contracts agreements are based on FIDIC Rules due to out source companies & deployements.

  • @mohdnaghman3742
    @mohdnaghman3742 4 роки тому

    Sir 300 ,by 300 ka column hai to iska steel ka 6 percent area hoga kya

  • @oms6335
    @oms6335 3 роки тому

    Joggle dena jruri hota h kya sir

    • @naturelove583
      @naturelove583 3 роки тому

      Yes,because it helps in transfer the load from top steel to bottom uniformaly

  • @imranwali5973
    @imranwali5973 4 роки тому

    Plz reply...

  • @vikrantkumarsah
    @vikrantkumarsah 4 роки тому

    Lap Length till system 6d IS code photo chahia

  • @cabp9
    @cabp9 3 роки тому

    Wrong details code has changed

  • @lynricafort3071
    @lynricafort3071 5 років тому

    Eglish pls