Lap Length Rules for Reinforcement Bars
Вставка
- Опубліковано 24 кві 2018
- What is lap length in Reinforcements Bars
Lap Length formula
Lap Length Calculation
What is Lap Length
What is Lap Splices
Lap Length Formula for Columns
Lap Length Formula for Beams
Overlap Length Calculation in Steel Bars
Lap Length Calculation for Bar Bending Schedule
Development Length and Lap Length
Whats is difference in between lap lengtj and development length
Overlap, Lap Splices, In this video i have explained just a basic things about the bar lap length / lap splices & there technical details according to IS 456, precautions during execution of reinforcement steel works, i think this topic should be clear to all site engineers also having the details of interview questions.
#Factualcivilengineering
#laplength
#laplengthFormula
Awesome video... Best knowledge centre on UA-cam thanks sir for helping people out
Good detail for interview, thanks sir
Good detail, thanks sir, it will help for interview questions
Helpful video for site engineers.
Very good & complete information , I like your channel keep upload more sir. ,,☺☺
Excellent video sir. thnx a lot.
Apki sari video jabardast h,
Good detail sir
Very good sir thank you
Good detail for interview. Thanks please make a video on lap zone in beams & columns
Narayan Bless You 🙏
thanks sir
Plz make a video on cover depending on exposure conditions
If lapping higher dia lap in lower dia in column then which dia is cosiderable
Awesome knowledge u have sir...Please make some videos also related how to read slab reinforcement
hi jawahar chauhan, there are lot of structural agencies & they have diff.concept of drawings pertain to their design. i will make a video on basic points, of slab reinforcement steel. Thanks for your support
Thanks sir .....Only two channel video I like ...First is u and other is l&t.....I have a slab reinforcement drawing how can I send this drawing pick ...If u will be explain this drawing I will thankful to u sir
fwd @ amit.ggn277@gmail.com
Thanks sir
Sir have u got slab reinforcement drawings
If the floor height is 3.6m and bar is 32mm and beam depth is 900mm then... Will 1.3 times of 50D is effective, Because lap will cross the bottom bar of beam....?
In lapping of bars in column which bar should be tilt, top bar or bottom bar...which one is correct???
Top
सर हमारे घर के contractor ने सभी columns में 12mm का सरिया use किया है बस 2 column ऐसे है जिनमे 4 T10 mm का सरिया लगा है, इन दो columns के बीच में दुरी 5ft की है, अभी सारे columns का construction plinth level तक ही हुआ है, कृपया मुझे बताये क्या में foundation से आती हुयी इन दो columns की 10mm की सरिया को T12mm की सरिया से overlap कर सकता हूँ क्या?? 🙏
Tell me where I will find the lap lenght for different size of bars and concrete in IS456?
By formula (D x 54)
Good morning sir,
Sir, I want to become professional engineer like you . I am doing job in Noida but my senior don't tell me technical point. They all are doing only labour management, I am also that's why I am leaving my job. I think so this is not a engineering. This is called supervising.
Brother mujhe v job dilwa do..in delhi ncr
Untill you got new better job, you don't leave job.
Keep searching.........
Sir plz make one video on cover topic as per Is code
Sure i will upload soon,
@@FactualCivilEngineering today got the answer that why we take lesser dia of bar in lap length,,may nay bohat search kiya ta ye reason mgr kahi b nahi mila ta,,so as laod is transfer from lesser dia of bar to higher dia of bar thats why we take lap length of lesser dia of bar
@@FactualCivilEngineering why this 6d bend is provided?technical reason hy iska koi dear sir
Sir 36 mm is also consider in build or above 36
Above
Gulf mein kaunse standards follow karne padenge....can u plz share
Mohammed ziauddin ahmed , first things is in gulf countiries all projects has world class facicilties & high end technology, so they mostely follow ASTM / British Standrads also the contracts agreements are based on FIDIC Rules due to out source companies & deployements.
Sir 300 ,by 300 ka column hai to iska steel ka 6 percent area hoga kya
5400 mm²..(6×300×300/100)
Joggle dena jruri hota h kya sir
Yes,because it helps in transfer the load from top steel to bottom uniformaly
Plz reply...
Lap Length till system 6d IS code photo chahia
Wrong details code has changed
Eglish pls
Sure,