Sorry you can not do like this. Because how the inverter is designed by default it's going to work like the way I have explained in the video. What you can do is build a system that is producing more power than you consume,so that it will serve your purpose. But the system needs to be installed by license electrician and it's need to be approved by the electricity board. Before doing anything you need to get an approval that you are going to do something like this.
Mata terena widihata Obage gataluwa tiyenne, solar panel dekama ekama charge controller ekata connect karala tiyana nisa. 310 w panel eke production eka 250w panel eke output ekata adu wenawa.mekata solution eka thamai solar panel deka wena wenama charge controllers dekakata laba dima. Meta amatharawa obage router deka direct 12v battery bank ekata laba denna. Oba Dan use karana widihata DC current eka AC walata convert karala router eke power adapter eken aye DC walata convert karanawa.me conversion eka nisa efficiency loss eka wadiy. Ihatha ki changes karala balanna Obage gataluwata wisadum labei. Samawenna reply karanna parakku unata.
Bohoma stuthi obage adahasata. Me sandaha obata awama washayen 3kw (3000w) inverter ekak awashyai. Ita amatharawa 4kw sola panels awashya wenawa Saha oba inna palathata direct sunlight labena eka matha solar panels adu karaganna puluwan.
Can we prevent reverse meter reading on older meters when we use a 500-watt grid connection inverter and 500-watt panels, causing our house consumption to mistakenly drop to 200 watts?
Sorry you can not do that.the inverter should have a limiter .to limit the export units.That is the only option to prevent the meter going backwards.This inverter is called "Grid tie inverter with the limiter"
Inverter eke output eka AC current eka hinda ganna tiyana siyaluma precautions ganna eka thamai sudusu. Main breaker ekata amatharawa trip switch ekak Saha breaker ekak ho RCBO ekak (meka trip switch eka Saha breaker eka combine karapu unit ekak) use karana eka thamai sudusu. Mama ilangata karanna yanne me sambanda video ekak.
Me inverter eka mama Dan avuruddakata aasanna kalayak use karanawa. Ada wenakan kisima gataluwak wela naha. godak salakilimath wenna ona inverter ekata podi insects lata yanna nodi.
Bohoma stuthi obage comments walata. Brands gana nam mama echcharama wiswasa karanne naha.miladi ganna welawe wada karanawanam Saha warranty ekak tiyanawada Saha online reviews Yana karunu thamai salakillata ganne.
Ehema use karanna baha. Ita hethuwa thamai Grid tie inverter ekata main current tiyenne ona eke current eka output wenna. Mema video eke islanding feature eka hindai oba kiyana widihata use karanna Bari. Mekata visaduma wanne off grid inverter ekak use karana eka. Me sandaha option dekak tiyanawa. 1.off grid solar system ekak hadanna puluwan 2.Charge controller ekai inverter ekai dekama ekata tiyana inverter ekak use karana eka.
Grid tie inverters walata witharai main current input ekak denna puluwan (CEB power). Off Grid inverters okkotama ehema hakiyawak naha (pure sign wave ,modify sign wave dekatama)
Inverter ekak miladi gannakota eke input voltage eka balanna. Input voltage ekata match wenna thamai solar panels ganna ona. Eth ekkama inverter eke capacity eka Thora gannakota ,mage inverter eka nam 500w eken 80% maximum mama use karanawa kiyala hitha gena thamai mama ganan haduwe. Ita passe thamai mama 250w average output ena widihata inverter ekata panels set kale. Ethakotat mata thawa buffer ekak tiyanawa inverter eke maximum capacity eka exceed novenna. Ehema karanne inverter eke durability eka wadi karagannai
api normal consumption eka 100w kiyala hithala oka fix karanawa. but grid tie inverter eka on eke thibiddi api fridge eka off kaloth below 100w wenawa. ex 50w. ethakota mokada wenne ?
Ehema karanna baha.deken ekak thamai eka welawakata use karanna puluwan eka panel set ekakin. Obata e widihata karanna ona nam, hybrid inverter ekak ganna.panel tika ekata connect karanna.battery bank ekath ekatama set karanna.e hera Mama Danna widihata wena option ekak naha. Bohoma stuthi obage comments walata
Bohoma stuthi obage comments walata Grid tie inverter eka order kale online market place ekakin Cash on delivery website ekak. UA-cam marketing affiliate nisa site eke nama mention karanna apahasui. Grid tie inverter kiyala search kalama online hoyaganna puluwan wewi
1. If your solar panels make more than 250W , what will happen to your system because your daily consumption is 250W ? 2. Your solar panel full output power is 620W. is it safe ..?(Parallel or serial - 620W)
1.if you produce more than your consumption you will be exporting power to the Grid. In order to export power to the Grid,your equipment should be certified by the electricity board and this system should be installed by a license electrician. The equipment that I used are not certified by the CEB and I'm not a license electrician, that's why I have design my system to compensate my usage. 2. I have connected these panels pararell.simply because if I connect them series the voltage will exceed the inverter maximum voltage. Due to this I have no other option than to connect them in parallel.The next thing that I could do is separate the panels and connect them to separate inverters.But then it's going to exceed my 250W limit. As I explained you in point 1 ,I cannot export power to the Grid.
Ow Grid tie inverter kiyala thamai nama. Inverter eke watt gananin search karanna. Inverter eke input voltage eka gana salakilimath wanna E anuwa thamai oba solar panels Thora Gatha yuththe
Online cash on delivery market place ekakin gaththe. Palaweni eka gaththe Rs 1800 kata wage.deveni eka gaththe Rs 4200 kata wage.eth avuruddakata kalin .dan nam prices wadi wela athi.hariyatama idea ekak Naha prices gana.
Bohoma stuthi obage comments walata. Mama obata pahadili Kala ,CEB ekata viduliya export karanne nathi thakkal , legally gataluwak wenne nathi bawa. Obata ehema gataluwak gana danenawanam hondama de Grid tie inverter with the limiter ekak use karanna.ethakota zero export to the Grid. Oba manually karana de inverter eken automatically karanawa.eka nisa eke prices Tikak ganan wadiy.namut obage gataluwa nirakaranaya wenawa.
@@DIYwithAsanka ane ayye godak sthuthiy, mata dana ganna on ape rotate wena CEB eke kWh meters , back spin wenne nadda kiyala , illeagal nisa comment karana eka weradi kiyala hithuna mata
Meter eka back spin wena eka illegal.eka legally karanawanam net meter ekak set karaganna ona.mekedi karala tiyenne gedara hamawelema use wena vottage eka balala ( base line eka ) ekata match wenna solar system eke output eka hadala tiyana ekai.mekedi meter eka backspin wenne naha.namut dawal kaledi avuvva tiyanawanam meter eka issarahata kerakenneth naha.
Me inverter eka Mama gaththe danata avuruddakata kalin Rs 18,000/= Me dawaswala prices gana idea ekak naha.aluthin ekak gannawanam micro grid tie inverter kiyala search karanna.meeta wada honda features eke tiyanawa.
ඉතාම වැදගත් තොරතුරු ඉදිරිපත් කිරිමත් .තෙරුවන් සරණයි නිදුක් නිරෝගී සුව ඔබට ❤️💐
Bohoma stuthi obage comments walata
පට්ට වටිනවා ඒකනම් කැල්කියුලේශන් ටික පොඩ්ඩක් අපහැදිලි උනා ඒකත් තව පාරක් බලලා ඉගෙන ගන්න ඕනී...
Thank you obage comments walata.
Saralawa kiwwot gedara Hama welema use karana wattage ekata wada aduwen thamai oyage grid tie inverter eke output eka wenna ona
Ehema nathnum karanna tiyenne grid tie inverter with the limiter option ekata Yana ekai.
Ekedi wenne obage load eka kochchara watt ganana unath ita wada wadi output ekak tiyana solar system ekak pawichchi karanna puluwan.
Ekedi inverter eke output eka ewelawe pawichchi karana load ekata match karagannawa.
වැඩේ හොඳයි. නොදන්නා අයට සාධාරන මුදලක් ගෙන හදලාදෙන්න.
Bohoma stuthi obage comments walata
250W 310W panal 2k tyanne .. 3000w inverter tyanne .. 150ah Deep cycle battery 2k tyanne.. dawalta karant eka use wenne router 2k withari.. pwm controller ekak tyanne ekada aula..
Thank you obage comments walata.mama obage kalin comment ekata reply Kala.
Obata apahadili deyak tiyenawanam comments wala Danna Mama Danna deyak nam anivaryenma reply karanawa.
hi, can i use a grid tie inverter and program it to only supply electricity to grid and not the house? (to take ceb supply at all times to the house)
Sorry you can not do like this.
Because how the inverter is designed by default it's going to work like the way I have explained in the video.
What you can do is build a system that is producing more power than you consume,so that it will serve your purpose.
But the system needs to be installed by license electrician and it's need to be approved by the electricity board.
Before doing anything you need to get an approval that you are going to do something like this.
310w 250w සොලා පැනල් එක එක තියනවා. 3000w inverter තියනවා .. 150ah ×2 battery දෙකක් තියනවා .. එත් inverter පවිච්ච් කරන්නෙ නැති දවසට බැටරිය chage වෙනවා. පවිච්ච් කරන දවස බැටරිය පොඩ්ඩයි චජ් වෙන්නෙ. 24w වගේ use වෙන්නෙ. රවුටර් දෙකක් විතරයි .. controller එක pwm controller එක මරැ කොරොත් හරි යයිද.
Mata terena widihata Obage gataluwa tiyenne, solar panel dekama ekama charge controller ekata connect karala tiyana nisa.
310 w panel eke production eka 250w panel eke output ekata adu wenawa.mekata solution eka thamai solar panel deka wena wenama charge controllers dekakata laba dima.
Meta amatharawa obage router deka direct 12v battery bank ekata laba denna.
Oba Dan use karana widihata DC current eka AC walata convert karala router eke power adapter eken aye DC walata convert karanawa.me conversion eka nisa efficiency loss eka wadiy.
Ihatha ki changes karala balanna Obage gataluwata wisadum labei.
Samawenna reply karanna parakku unata.
Watura motarayak duwawanna wat kiyaka Penal akak oneda . . datari netiwa inwaitar haraha denna puluwanda video akak danna
Bohoma stuthi obage adahasata.
Me sandaha obata awama washayen 3kw (3000w) inverter ekak awashyai.
Ita amatharawa 4kw sola panels awashya wenawa Saha oba inna palathata direct sunlight labena eka matha solar panels adu karaganna puluwan.
Can we prevent reverse meter reading on older meters when we use a 500-watt grid connection inverter and 500-watt panels, causing our house consumption to mistakenly drop to 200 watts?
Sorry you can not do that.the inverter should have a limiter .to limit the export units.That is the only option to prevent the meter going backwards.This inverter is called "Grid tie inverter with the limiter"
සුරිය පැනල සක්ක සෙල්ටික කලු වෙන්න පට වෙලා මට දැනගන්න තියෙන්නෙ අයියා මට තනියම හදාගන්න පුළුවන් ද කියලා වීඩියෝ එකක් කරන්න. අයියාට බුදුසරණයි
Mulinma balanna solar panel eke diode tiyanawanam, multimeter ekakin check karala balanna,diodes hondaida kiyala
(Solar panel eka pitipasse plastic box ekak tiyanawa,eka athule solar panel eken ena connection ekata passe eliyata ena wire dekata kalin me deka athara diodes 2 ho 4 balaganime hakiyawak tiyanawa).namut samahara panelwala diodes naha.
Visually balanna iyam pati tika hondin tiyanawada kiyala.than 1 Ka 2ka nam connection eka pichchila tiyenne,panel eke pitipassen widala aluthin wire ekak dala hadaganna puluwan.
Than 2 kata wada tiyanawanam me prashne ,e kramaya saarthaka naha.
Boho seemitha damages tikak witharai solar panels wala apita thaniyama hadaganna puluwanka tiyenne.eka nisa UA-cam eke videos balanna,samahara kattiya me damages temporary hadagaththa ewa tiyanawa.namut solar panel manufacturers la hadana quality eka apita repair karaganna Bari hinda awuvve rasnayath ekka ,karapu repairs tika kalayakin galawenawa.
E nisa experiment ekak widihata Hari deyak igenaganna mewage deyak Kala harenna long term use walata mewage repair Mama recommend karanne naha.
Thanks,,, mamath request kara grid tie aka gana karanna kiyala... Good job...
Thank you obage comments walata.
Mama hithanawa obage request eka fulfill una kiyala
gaththa thena wisthara matath denawa da
Bohoma stuthi obage comments walata.
Grid tie inverter eka order kale online market place ekakin
Cash on delivery website ekak.
1. 200w grid tie inverter 1k use karanawanam gedara usage 1 samahara welawata 3000w wage wena awastha tiyenawa. Evita inverter 1ta haniyak na neda. 2800w grid 1n gannawa api 200w denawa ehema neda.
2. Gedara usage 1 very wena 1 auto adjust karan pump karanna hadanna puluwanda. Ex:- 300w panal 1k dala system 1 hadanawa namuth gedara continuse usage eka 100w but over yanawa 250w,300w wage
1.inverter eke output ekata wada usage eka wadi Una kiyala grid tie inverters walata gataluwak naha.
Mulinma grid tie inverter eke output eka use karala extra tika thamai CEB eken ganne.
2.me sandaha obata hondama de thamai grid tie inverter with the limiter ekak miladi ganna eka.
Ethakota usage eka anuwa inverter eke output eka eya adu wadi karagannawa.
Namut koima welawakawath over produce karala ewa grid ekata nikuth wenne naha.
Ups ekakta solr charger control eken 12v dila tv ekakta 230 ganda puluwn weida, inwetar ekak nethuwa
Ow karanna puluwan.charge controller eke output eka direct ups battery ekata thamai laba denna awashya wenne.
Ups eke battery capacity eka adu hinda half an hour wage thamai use karanna puluwan wenne.
Loku capacity ekaka battery ekak dala meta wada wadi welawak use karanna puluwan.
Ups eke buzzer ekat remove karanna awashya wenawa.
අයියේ 14. V / 15v වගේ පැනල් එකකින් ඇම්පියර් 65 12 v battery එකක් චාජ් කරගන්න පුලුවන් ද ඉන්වයිටර් එකේ out එකට දාන්න ඕනමද MCB එකක් අනිවාර්යයෙන් ..
Inverter eke output eka AC current eka hinda ganna tiyana siyaluma precautions ganna eka thamai sudusu.
Main breaker ekata amatharawa trip switch ekak Saha breaker ekak ho RCBO ekak (meka trip switch eka Saha breaker eka combine karapu unit ekak) use karana eka thamai sudusu.
Mama ilangata karanna yanne me sambanda video ekak.
මං Inverter එකක් ගත්තා 2000W. Continues power එක 1000 තියෙන. ඒක 35Ah Threewheel Battery එකකට connect කරාට පස්සෙ Inverter එකේ Fault කියල වැටෙනවනෙ. ඇයි ඒම වෙන්නෙ ? 😓😓
Me sandaha hethu kihipayak tiyenne puluwan.
Issellama wena battery ekakata connect karala balanna inverter eka wada karanawada kiyala.
Ehema wada karanawanam battery eke voltage eka pennuwata load ekak ganna yanakota battery eke voltage eka drop wenawa.
E kiyanne , battery eka honda naha.maaru karanna awashyai kiyana eka.
Kalin pahadili kala wage mulinma inverter eka check karala Inna .
Inverter Eka use kranna aran kochchara kalayak wenawada?
Godak kal use kranna puluwn model ekakda Eka?
Me inverter eka mama Dan avuruddakata aasanna kalayak use karanawa.
Ada wenakan kisima gataluwak wela naha.
godak salakilimath wenna ona inverter ekata podi insects lata yanna nodi.
@@DIYwithAsanka Thanks for the information 👍🏻
You are most welcome
Honda inverter brand 1k recomond karanna puluwanda
Bohoma stuthi obage comments walata.
Brands gana nam mama echcharama wiswasa karanne naha.miladi ganna welawe wada karanawanam Saha warranty ekak tiyanawada Saha online reviews Yana karunu thamai salakillata ganne.
Inverter එකේ Output එකට Extension Cord එකක් සම්බන්ධ කරල උපකරණ කිහිපයක් ඒක හරහා පාවිච්චි කරන්න පුලුවන්ද ? (සම්පූර්ණ ගෙදරටම ගන් නැතුව)
Ehema use karanna baha.
Ita hethuwa thamai Grid tie inverter ekata main current tiyenne ona eke current eka output wenna.
Mema video eke islanding feature eka hindai oba kiyana widihata use karanna Bari.
Mekata visaduma wanne off grid inverter ekak use karana eka.
Me sandaha option dekak tiyanawa.
1.off grid solar system ekak hadanna puluwan
2.Charge controller ekai inverter ekai dekama ekata tiyana inverter ekak use karana eka.
@@DIYwithAsanka Pure Sinewave Inverter එකක් අරගත්තොත් Output එකට Connect කරන්න පුලුවන්ද
Grid tie inverters walata witharai main current input ekak denna puluwan (CEB power).
Off Grid inverters okkotama ehema hakiyawak naha (pure sign wave ,modify sign wave dekatama)
Niyama
Thank you for your comments
Grid tie inverter with the limiter option
මේ සම්බන්දව කියලා දෙන්න පුලුවන්ද ?
අපි කොහොමද මේක මිලදී ගන්නෙ වගේ දේවල් එහෙම.
Inverter ekak miladi gannakota eke input voltage eka balanna.
Input voltage ekata match wenna thamai solar panels ganna ona.
Eth ekkama inverter eke capacity eka Thora gannakota ,mage inverter eka nam 500w eken 80% maximum mama use karanawa kiyala hitha gena thamai mama ganan haduwe.
Ita passe thamai mama 250w average output ena widihata inverter ekata panels set kale.
Ethakotat mata thawa buffer ekak tiyanawa inverter eke maximum capacity eka exceed novenna.
Ehema karanne inverter eke durability eka wadi karagannai
Obawa sambanda kara ganna puluwan durakathana ankayak laba denna puluwanda
Mawa sambanda karaganna puluwan lesima kramaya thamai UA-cam channel eke playlist eke tiyana Onama video ekakata obage gataluwa idiripath kirima.
Mama Danna deyak nam anivaryenma reply karanawa
api normal consumption eka 100w kiyala hithala oka fix karanawa. but grid tie inverter eka on eke thibiddi api fridge eka off kaloth below 100w wenawa. ex 50w. ethakota mokada wenne ?
Ethakota oba gawa tiyana electricity meter eka Parana ekak nam,(disk eka tiyana ekak nam) meter eka reverse ekata yanawa.
Namut oba gawa tiyana meter eka aluth ekak nam ,oba grid ekata wadipura pump karana watt gananatat obata charge wenawa.
Namut oba gawa tiyana meter eka digital ekak nam (smart meter) ekata hakiyawak tiyanawa oba Grid ekata pump kalada kiyala balanna puluwan.
Emagin CEB eken obata gataluwak Athi wenna puluwan
@@DIYwithAsanka bohoma sthuthi. ee gana mama danan hitiye na. :-)
Bohoma stuthi obage comments walata.danumata yamak ekathu karanna labima gana sathutui.
Micro inverter එකක් වැඩ කරනවද කියලා කොහොමද හොයා ගන්නේ.පැනල් එකකට සම්බන්ධ කරලා Check කරන්නේ කොහොමද?
Meka check karanna puluwan watt meter ekakin witharai.panel eka connect karala inverter eke warning lights indicate wenawada kiyala balanna.inverter eke indicater lights natnum inverter eke AC output ekata watt meter ekak connect karala balanna .watt meter eke agayak pennanawa kiyanne inverter eka wada karanawa kiyana ekai.
Watt meter eke agayak pennan natnum solar panel eke rated DC output eka enawada kiyala balanna.ita passe inverter eke fuses check karanna.oya okkoma hondata tiyanawanam inverter eka wada karanne naha.pichchila .boho welawata repair karaganna puluwan.
ස්තූතියි සොයුර. නිදුක් නිරෝගී සුව. මට 300w පැනල් 2ක්, grid tie inverter එකට සෙට් කරලා තියෙන අතර 60A charge controller එකක් හරහා off-grid inverter එකට 120A battery 2ක charge කරන්න පුළුවන් විදිහ මොකක්ද.
Ehema karanna baha.deken ekak thamai eka welawakata use karanna puluwan eka panel set ekakin.
Obata e widihata karanna ona nam, hybrid inverter ekak ganna.panel tika ekata connect karanna.battery bank ekath ekatama set karanna.e hera Mama Danna widihata wena option ekak naha.
Bohoma stuthi obage comments walata
ස්තූතියි ඔබට. ජය ❤️💐
Bohoma stuthi obata.
Meeka ganna puluwan thanaka wistharayak dennako.
Bohoma stuthi obage comments walata
Grid tie inverter eka order kale online market place ekakin
Cash on delivery website ekak.
UA-cam marketing affiliate nisa site eke nama mention karanna apahasui.
Grid tie inverter kiyala search kalama online hoyaganna puluwan wewi
1. If your solar panels make more than 250W , what will happen to your system because your daily consumption is 250W ?
2. Your solar panel full output power is 620W. is it safe ..?(Parallel or serial - 620W)
1.if you produce more than your consumption you will be exporting power to the Grid.
In order to export power to the Grid,your equipment should be certified by the electricity board and this system should be installed by a license electrician.
The equipment that I used are not certified by the CEB and I'm not a license electrician, that's why I have design my system to compensate my usage.
2. I have connected these panels pararell.simply because if I connect them series the voltage will exceed the inverter maximum voltage. Due to this I have no other option than to connect them in parallel.The next thing that I could do is separate the panels and connect them to separate inverters.But then it's going to exceed my 250W limit.
As I explained you in point 1 ,I cannot export power to the Grid.
@@DIYwithAsanka thanks for the information.
You are welcome
Api kohomada Grid tie inverter ekak ganne
Online cash on delivery website ekakin thamai mama miladi gaththe.
UA-cam eke Affiliate marketing rules nisa site eke nama mention karanna apahasui
A inverter ekata kiyana nama mokakda..
Grid tie inverter kiyalada kiyanne
Ow Grid tie inverter kiyala thamai nama.
Inverter eke watt gananin search karanna.
Inverter eke input voltage eka gana salakilimath wanna
E anuwa thamai oba solar panels Thora Gatha yuththe
@@DIYwithAsanka nama sinhalen kotanna
Wat මිටරය ගත්තේ කොහෙද ? කියද?
Online cash on delivery market place ekakin gaththe.
Palaweni eka gaththe Rs 1800 kata wage.deveni eka gaththe Rs 4200 kata wage.eth avuruddakata kalin
.dan nam prices wadi wela athi.hariyatama idea ekak Naha prices gana.
හොයපු විඩියෝ එකක්.
Thank you very much obage comments walata
අලුත් වැඩියාවකට විදුලිය විසන්දි කලහම ඉන්වර්ටර් එකෙන් out එකක් වෙන් නෑ නේද?ඔයා ප්ලග් එකෙන් ගලවලා අල්ලනකොට වෙන දේන නේද වෙන්නෙ.
Ow oba Hari.
Godak online order karana inverters wala me safety features okkoma wage tiyanawa.ekama wenasa me inverters CEB approved ewa newe tiyenne.
ඕක illegal නේද?
Video pahadili karana widihata Grid ekat viduliya export karanne nathi thakkal me sambandayen legally gataluwak wenne naha .
@@DIYwithAsanka CEB එකෙන් දැන ගත්තොත් අවුරුදු 10ක් යනකන් ලයින් එක disconnect කරනවා .
Bohoma stuthi obage comments walata.
Mama obata pahadili Kala ,CEB ekata viduliya export karanne nathi thakkal , legally gataluwak wenne nathi bawa.
Obata ehema gataluwak gana danenawanam hondama de Grid tie inverter with the limiter ekak use karanna.ethakota zero export to the Grid.
Oba manually karana de inverter eken automatically karanawa.eka nisa eke prices Tikak ganan wadiy.namut obage gataluwa nirakaranaya wenawa.
ayye contact no eka denna baida?
Mawa sambanda karaganna tiyana lesima kramaya thamai onama video ekakata comment karanam eka .hethuwa mama tika kalekata raten pita inne.time difference eka hinda phones walin connect karaganna amarui.Tikak parakku unath anivaryen comments walata reply karanawa Danna deyak nam
Thank you obage comments walata
@@DIYwithAsanka ane ayye godak sthuthiy, mata dana ganna on ape rotate wena CEB eke kWh meters , back spin wenne nadda kiyala , illeagal nisa comment karana eka weradi kiyala hithuna mata
Meter eka back spin wena eka illegal.eka legally karanawanam net meter ekak set karaganna ona.mekedi karala tiyenne gedara hamawelema use wena vottage eka balala ( base line eka ) ekata match wenna solar system eke output eka hadala tiyana ekai.mekedi meter eka backspin wenne naha.namut dawal kaledi avuvva tiyanawanam meter eka issarahata kerakenneth naha.
L I K E👍👍👍👍👍👍 🤩🤩🤩🤩🤩😎
Thank you very much for your comments
ඔය ජාතියේ උන්වටරයක් කිය්ක් වෙයිද දාල අදහස්ක් කියන්න
Me inverter eka Mama gaththe danata avuruddakata kalin Rs 18,000/=
Me dawaswala prices gana idea ekak naha.aluthin ekak gannawanam micro grid tie inverter kiyala search karanna.meeta wada honda features eke tiyanawa.