  • @keithjurena9319
    @keithjurena9319 Рік тому +2

    Lucas, prince of darkness ;) I would assume that is a points type regulator. Sensitive to corrosion and wear.

    • @stephens7107
      @stephens7107 Рік тому

      That’s what vintage British car owners call Lucas. Ask me how I know😊

  • @ralphnorris-vk8ff
    @ralphnorris-vk8ff 10 місяців тому

    Go to alstate agg parts and you came get an alternater conversion cheaper than you can repair the generator!

  • @12334ttqtqt
    @12334ttqtqt 6 місяців тому

    My negative cable keeps burning on the battery. What can i do. ?

    • @stevewatr
      @stevewatr  6 місяців тому

      There are a few causes that come to mind. First is too light a wire gage. The diesel tractor starters need more current. Size should be 2/0, and not then some as 2 AWG wire. A gas For tractor might even have 4 AWG, adding to the confusion. Wire thickness goes up a the gage number decreases until you get to 1AWG, then the numbers go up from 1/0 2/0 etc. If your wires are old and have corrosion, they will add resistance to the circuit causing issues. Lastly, if the wires are large enough and in good condition, it could be a bad starter. Just because it still turns does not mean its good. Sometimes the starter will start to turn slower and draw excessive current when near the ends of its life. By the way, the oem Ford starters are worth rebuilding ( in may opinion).

  • @Rillust
    @Rillust 10 місяців тому

    Doesn't the idle have to be a certain rpm to produce Genny output? I know for a fact the genny wont output at idle. At least I'm pretty sure. Nevermind. Your other video cleard that up for me. Thanks.

  • @WilliamTMusil
    @WilliamTMusil Рік тому +1

    Hiya Steve

  • @gbowne1
    @gbowne1 Рік тому

    2:16 that's made by Lucas.. I've fixed a bunch of those.

  • @joshbutterfass5251
    @joshbutterfass5251 Рік тому

    That generator looks original to the tractor for as rusty as it looks

  • @trekzilladmc
    @trekzilladmc Рік тому

    I had so many problems with my Ford 4400 generator that I installed an alternator conversion kit. Best thing I ever did for it.

    • @stevewatr
      @stevewatr  Рік тому

      Yup. If it wasn't for that teach drive its would be a cheap conversion. But the alternator with mechanical teach drive kit is about 300 and you cannot use an electronic teach on the diesel engines.

  • @Flowing23
    @Flowing23 Рік тому

    Hi Steve, could you just have replaced the generator with a new 12 Volt off the shelf alternator. How would that interact with the “current voltage regulator” box? Thank you.

    • @stevewatr
      @stevewatr  Рік тому +1

      Replacing a generator with any alternator is a common conversion done on old tractors. Since an alternator has regulation built into it, when converting, the regulator is not needed. Alternators are more efficient, and able to deliver more current on demand so great for running more lights etc. The issue with this tractor and several others is the tachometer drive on the back of that generator. They do make a special alternator with the drive on it but its around $300.

    • @Flowing23
      @Flowing23 Рік тому

      @@stevewatr thank you very much Steve👍

  • @Roubian1
    @Roubian1 Рік тому

    What was the outcome? Was the voltage regulator the problem?

    • @stevewatr
      @stevewatr  Рік тому

      After I get the generator working I worked on the regulator. There is a playlist for the ford 5000. Also there is a video just on the lucas regulator repair.

  • @joecritch143
    @joecritch143 Рік тому

    So was it the voltage regulator?

    • @stevewatr
      @stevewatr  Рік тому

      First I repaired the generator and then the regulator.

  • @Flowing23
    @Flowing23 Рік тому

    👍👍