How to Use Your Pool Heater, Put it into Spa Mode & Helpful Tips (Jandy JXi shown)

Поділитися
Вставка
  • Опубліковано 18 жов 2017
  • If your heater is not connected to an automated system, turning it on and heating up your pool and spa can be confusing. Almost all heaters have a simple to use control panel that you can use to turn on the heater and set the desired temperature. In this video I am using the Jandy JXi Pool & Spa Heater but your heater is probably very similar to it.
    On the heater itself is the control panel and from there you can turn the heater on and set it for pool or spa mode. Once the pool pump is on you can then set the heater to the desired temperature and turn it on. If you are going to heat an attached spa, you will have to turn the valves to spa mode. I go over that in detail in the video.
    Let me go over some common mistakes and user errors when it comes to manually setting your heater.
    I see these mistakes out on my pool route and once you know about them you will be much wiser when using your heater.
    Heater has no power?
    The buttons on the heater will not function unless the pool pump is turned on. If you are trying to turn on the heater outside of the pool's daily timed run cycle you will need to turn the pump on at the timer box. Once the pump is on and running you should see the control panel on the heater activate. Now you can set the heater to the desired temperature and mode - either pool or spa mode.
    Can I heat the Pool with the Spa Settings?
    You can heat the pool from either “Pool” or “Spa” mode but the heater has a dedicated mode for a reason. In each mode you can set a desired temperature and the heater will save that set temperature for you. So if you turn on your heater to heat your pool and you press the “Spa Heat” button the pool will then heat up to whatever temperature is set for the spa. Usually it is set at 98-100 degrees. So the pool will heat up to 98-100 as if it were the spa. So it is best to use the “Pool” button and set that temperature to your desired level, usually 80-85 degrees. So both buttons will turn on the heater but each button has a set temperature for either the pool or spa.
    How do I put my Heater in Spa Mode?
    This is a very common problem and I think the pool valves can be a little hard to figure out. The majority of pools use Jandy valves, notice that the small handle part is the “on” position and the large flared part marked “off” is the off position. The suction line valve is located right in front of the pool pump. Turn this valve handle completely to the opposite direction. Then find the return line valve handle and turn that one completely to the opposite position. The return valve is the one coming out of the heater. Once you have both of these valves turned you should be in “Spa Mode.” After doing this several times you will get the hang of it. When done make sure you turn the valves back again so that it will be in “Pool Mode” when the timer starts up later that day or the next day. Otherwise the pool will remain off all week and it will be circulating only the spa.
    Why is my Heater running the next day still?
    One thing that you must do when you finish using the heater, besides turning the valves back to pool mode from spa mode is to turn off the heater. Most heaters have a pretty obvious “off” button. The heater may turn off during use once it reaches the set temperature but to actually turn it off after use you will need to hit the “off” button on the heater itself when you are done using it. Note also that if you turn the pump off before turning off the heater and you push the “off” button on the heater, it will not turn off. Remember, for the buttons to be active the pump must be running. So before turning off the pool pump, hit the “off” button on the heater. If you fail to do this the heater will be running every time the pool turns on for it's timed programmed cycle. So the pool can potentially be heated all week and in most cases if you were using the spa and turned the valves back to pool mode the pool will heat up to the spa temperature (98-100 degrees) giving you quite hefty gas bill.
    My Spa is draining down after I used it last night?
    Unless it is a bad check valve chances are you didn't turn the valve completely back to pool suction and it is still partially open to the spa suction. Since most spas have a small bypass returning water to it, even a small amount of suction from the spa drain will cause it to drain down. Just make sure that you turn the valves completely back to pool mode when done.
    So these are some common user errors and mistakes that are made when using the pool heater. One way to ensure that the heater will not turn on after using it is to shut off the gas line after each use. Many heaters are installed with a simple shut off handle and this is a great way to insure you won't get hit with a giant gas bill.
    Related videos:
    Jandy JXi Pool & Spa Heater Overview Video: • Jandy JXi Pool & Spa H...
    eBook: www.swimmingpoollearning.com/...

КОМЕНТАРІ • 80

  • @philiphuestis4252
    @philiphuestis4252 3 місяці тому

    Amazing content. Thank you!!

  • @JorgeRodriguez-pv4vr
    @JorgeRodriguez-pv4vr 2 роки тому

    Thank you mr, your informatión was very importan for me. ✌

  • @radareddy123
    @radareddy123 5 років тому +3

    Any ideas how to fix or what the problem could be?

  • @loumach777
    @loumach777 2 роки тому +3

    Great video, thank you. Everything was perfectly explained. When setting up the Aqualink, how do I know if I have a TSTAT 2-wire or a Hi-Lo-Com 3-wire connection? I'm not ever sure what that means. The pool servicer was too busy to help me set it up, so I'm waiting for another to come help me set up my new pool.

    • @SPL
      @SPL  2 роки тому

      It depends on the automated system. You can call Jandy to see which one you should use.

  • @amirdjschannel3503
    @amirdjschannel3503 2 роки тому

    Hi, What gauge wire do I use for connecting thie JXI heater to the PSL4 (heater is within 6 feet of controller) for remote operation? Can I use Spa and Com or do I have to use Pool and Com on JXI Logic board. Thanks

  • @VSJ2012
    @VSJ2012 2 роки тому

    Thank you for posting this video, very helpful.

  • @jennaquinn4831
    @jennaquinn4831 2 роки тому

    My pool/spa was left in spa mode for a couple hours, now my Jandy heater is telling me to "check flow" , and I'm new at this. What do I do to fix it?

  • @Sports_Card_Fanatic
    @Sports_Card_Fanatic 29 днів тому

    Thx

  • @wellseenow3711
    @wellseenow3711 2 роки тому

    Thank you fo the video. Could you tell me how to disable the remote setting back to OFF so I can turn on the heater manually.

    • @SPL
      @SPL  2 роки тому

      I would give Jandy Tech support a call and they can help you with that:
      800-822-7933

  • @242tarot8
    @242tarot8 6 років тому +4

    I have a question concerning the heater once it's on it sounds like there is a pair of tennis shoes in the dryer banging around so I contacted a pool specialist and he told me that the piece that I need is a heater coil that has possible corrosion around it it......he said the part is the most expensive, coning in at around 1200

    • @SPL
      @SPL  6 років тому

      That is a great way to describe that sound - which I have heard before in heaters out in the field. I like describing it as small woodland critters running around on the inside of the heater, but I like your description better. Usually that is caused by the air/water mixture. If you have a variable speed pump make sure it is on the maximum RPM when heater is running. If it is set to high or if you have just a standard pump, calling a technician out to adjust the air/water mixture is needed. It is a pretty specific adjustment and only the manufacturers recommended warranty tech can do it. Look online at your heater manufacturer's site and find a local warranty company who can service it (note that even if your heater is out of warranty, the best companies to call are actually those who do the warranty work for the manufacturer - if that makes sense).

  • @rayhaglerpiano
    @rayhaglerpiano Рік тому

    How do you take off the remote tstat

  • @brandonc9438
    @brandonc9438 Рік тому

    Thanks for the great video! My spa is at 62 degrees and I put it at 99 like you, how long will it take to heat up? Also, how much damage do you do to your energy bill? :)

    • @SPL
      @SPL  Рік тому

      About 25-30 minutes. Figure about $10.00 for 2 hours of use.

  • @shanefernandez17ca
    @shanefernandez17ca 6 років тому

    Hi I want to install the Hayward 140 BTU heat pump but the manual states I need 24 inches of clearance on all sides. I do not have that luxury I would need to install it on one side about 6 inches away from the house only on one side. Will this be a problem or can I still go ahead and purchase and install? Thank you

    • @SPL
      @SPL  6 років тому

      I suggest calling Hayward Tech Support directly - you don't want to do anything if it will be a hazard of any kind. Hayward:866-429-7665

  • @MightAsWellK5
    @MightAsWellK5 4 роки тому

    Great Video! I've got a Jandy 400LXi but can't seem to put it into the Setup Mode you demonstrate (press all 3 buttons simultaneously for 7-10 seconds)... Does that indicate a bad keypad, or perhaps some larger issue? The unit is currently in "** Remote T-Stat Enabled ** mode, but doesn't appear to be calling for heat properly. I was going to just put the unit in Manual mode to see if that would work to isolate my problem further.... Any tips? Thanks!

    • @SPL
      @SPL  4 роки тому

      I would call Jandy/Fluidra tech support. Maybe it is a warranty issue.

    • @MightAsWellK5
      @MightAsWellK5 4 роки тому +1

      @@SPL Thanks! I just tried again, and was able to at least able to disable the "Remote T-Stat Enabled" mode... the heater fired up and is now warming the pool manually.... Doesn't seem to be a physical issue (like a bad button or controller).. something about the remote sensing doesn't seem to realize that it should be calling for heat or doesn't recognize the threshold temperature properly. I'll give Jandy a call tomorrow. Appreciate the help / response! Have a great day.

  • @benjamincamacho9103
    @benjamincamacho9103 3 роки тому +1

    Hi, we have Jandy JXI pool heater yesterday we had a power outage and the heater now reads "Fault check versaflo". would you know how to reset the heater. thank you.

    • @SPL
      @SPL  3 роки тому

      You may have to call Jandy on that one on monday. 800) 822-7933

  • @amirdjschannel3503
    @amirdjschannel3503 2 роки тому

    I just got a Jandy JXI400NK natural gas heater with the built in Versaflo. I want to connect it to my Pentair PSL4 controller. Can I use the RS-485 com port with the Pentair Com port to control the pool heater with automation? I’d like to use the full functionality of the pool heater if possible. Thanks.

    • @SPL
      @SPL  2 роки тому

      You would have to call Jandy Tech support on that one.

  • @TrapMobMesquite
    @TrapMobMesquite 5 років тому +2

    Should I hear the igniter kick on? I have done everything you said and there is no hot air coming out and the water remains cold after an hour. I have plenty of propane in my tanks. Also there is no indicator lights saying that there is a problem

    • @SPL
      @SPL  5 років тому +1

      Yes, the igniter should kick on. The valve to the propane is open? I have to ask.

    • @Emie8230
      @Emie8230 3 роки тому +1

      @@SPL I'm having the same issue today, everything is clear and I have propane, I'm not hearing an igniter switch or heater turn on even though remote said it's on,, please help! And my pool is new and this is the first time I've had this issue

    • @georgeisom8326
      @georgeisom8326 3 роки тому

      Something say aux is not on

  • @tyvaughn2225
    @tyvaughn2225 2 роки тому

    Hey man sorry to bug you on a Sunday. I’m getting a check flow set on my zodiac propane heater. Last week I just took off the out flow cover (water flow was air locked) turned it on and quickly replaced the cover. It water flow was fine and heater came on. Today it just won’t come on and check flow set won’t go away.
    Help me Doc!

    • @thomassaylor6987
      @thomassaylor6987 Рік тому

      same issue with mine,check flow set shows up on the screen

  • @thealldaybreakfast
    @thealldaybreakfast 2 роки тому

    Receiving the error message "Check Flow Set". Any suggestions on a fix? Assuming the volume of water is not meeting the minimum threshold.

    • @SPL
      @SPL  2 роки тому

      Try running the pump at full speed - if it is a VS pump.

  • @thewiledforestfire7882
    @thewiledforestfire7882 5 років тому +1

    How do you fix the check flow

  • @reneepryor6604
    @reneepryor6604 3 роки тому

    I'm having issues connecting the aqua link pdaremote to the jandi jxi heater. The heater shows the remote is enabled but the remote shows heater is off line. How do I turn the heater back on line?

    • @SPL
      @SPL  3 роки тому

      Give Jandy tech support a call. That is an odd issue.

  • @eridiaz6981
    @eridiaz6981 4 роки тому +1

    Hello, I set my jandy to 104 on the spa but it doesn't feel like its 104. But on the screen it says it is at 104. I clean the filters and it still feels the same. Any idea what could be the issue?

    • @SPL
      @SPL  4 роки тому

      Is it connected to an automated system?

    • @eridiaz6981
      @eridiaz6981 4 роки тому

      @@SPL do you mean like a timer on the heater that it should turn off after a certain time?

    • @SPL
      @SPL  4 роки тому

      @@eridiaz6981 No, just wanted to know if there is a separate temp sensor set up with your equipment. If you have an Aqualink panel there is a temp sensor for the automation.

    • @eridiaz6981
      @eridiaz6981 4 роки тому

      @@SPL it is connected to the iaqua link.

  • @3arc_Paulo88
    @3arc_Paulo88 2 роки тому

    I'm running into an issue where the screen on my heater is showing the pool as 87 but when I look at the heat in the iaqualink app its showing the pool at 70. Do you know what could be happening here ?

    • @SPL
      @SPL  2 роки тому

      It might be a bad temp sensor on the automation.

  • @radareddy123
    @radareddy123 5 років тому +2

    I have a Hayward R400 and when I fire it up to heat the hot tub, it sounds like it’s popping corn on the inside. It eventually stops but I am concerned it could be dangerous

    • @SPL
      @SPL  5 років тому

      It sounds like the air/gas ratio is off. If you are using a VS Pump make sure it is running at the full 3450 RPM. If your pump is running at full speed and you heater still makes the loud rattling noise a technician needs to come out from Hayward and adjust this. It can only be adjusted by a trained technician. If you go to Hayward's Website you can find a local service tech in your area who can adjust this for you.

  • @JenniferDeAlba-gu5ht
    @JenniferDeAlba-gu5ht 28 днів тому

    Is this gas specific or can you use propane as well?

    • @SPL
      @SPL  28 днів тому

      Natural Gas specific.

  • @sirmatt6143
    @sirmatt6143 10 місяців тому

    Mine worked great for 2 weeks
    ..I set it on 88 degrees and water showed to be that or higher during the day….
    Then one day I noticed lots of water at bottom… also had it set at 88 degrees but the next morning water was at 84…. Fan is spinning but not heating up like it did the first couple weeks

    • @SPL
      @SPL  10 місяців тому

      It could be something simple like the winterizing plug is leaking. But any leak from the heater is not normal.

    • @sirmatt6143
      @sirmatt6143 10 місяців тому

      I’m more concerned with it not heating up… it held the set temp for about 3 weeeks straight and then all of a sudden it stopped heating

  • @douglasolsson7768
    @douglasolsson7768 2 роки тому

    What speed do you set the pump for good jets in the spa?

    • @SPL
      @SPL  2 роки тому

      3100 RPM or higher works.

    • @douglasolsson7768
      @douglasolsson7768 2 роки тому

      @@SPL Doesn't have the power of a stand alone fiberglass jacuzzi. But thanks for the info.

  • @misunderstood1233
    @misunderstood1233 Рік тому

    I don’t have a hot tub or spa feature. When I turn on the heat from the remote the spa light on the handy heater turns on. Is this ok. Or should the pool light turn on?

    • @SPL
      @SPL  Рік тому

      It doesn't matter which one you use if you don't have a spa.

    • @misunderstood1233
      @misunderstood1233 Рік тому

      @@SPL thank you so much. I appreciate the info.

  • @haydenbishop9788
    @haydenbishop9788 3 роки тому

    On my heater it says “check flow” what does that mean? What do I need to do?

    • @SPL
      @SPL  3 роки тому +1

      Not enough water is going through it.

  • @rodolfolara3079
    @rodolfolara3079 4 роки тому

    En españis

  • @josephpeck4315
    @josephpeck4315 Рік тому

    Does that spa have a bubbler?

    • @SPL
      @SPL  Рік тому

      No. Just the jets on full blast

  • @krisbrown3190
    @krisbrown3190 3 роки тому

    Can u help mine says turned on and went and said check flow settings???

    • @krisbrown3190
      @krisbrown3190 3 роки тому

      I'm sorry, it turned on and was starting to heat up then it stopped and said check flow settings????

    • @SPL
      @SPL  3 роки тому

      Maybe pump speed is set to low or filter is dirty

  • @brucewilkerson6452
    @brucewilkerson6452 3 роки тому

    My heater is not coming on how can I turn it on there is nothing coming up in the screen

    • @SPL
      @SPL  3 роки тому

      Could be the breaker or if it is connected to an automated system that will supersede the controller on the heater.

  • @longbra
    @longbra 2 роки тому

    All well and good when you can see the display. I just purchase a house and the heater doesn't seem to have any power going to it or the display is out.

    • @SPL
      @SPL  2 роки тому

      It could be connected at the automation if you have a panel. So the screen only comes on when you hit the heater button. I am guessing here.

  • @addybo_
    @addybo_ 3 роки тому

    What does no flow mean. Everytime I hear my pool my handy system says that

    • @SPL
      @SPL  3 роки тому

      It just means the water is probably not moving fast enough to activate the heater -if you have a VS pump turn up the speed when you heat it.

    • @addybo_
      @addybo_ 3 роки тому

      @@SPL ok one more question man. So the house I’m renting let’s us heat our pool/slash hot tub witch is attached. Everytime I hear the hot tub to 100 degrees the pool gets to the same temperature too. Am I doing something wrong

  • @nicholaselopez2629
    @nicholaselopez2629 3 роки тому

    My heater shows nothing, it’s just blank, I have no idea what happen?

    • @SPL
      @SPL  3 роки тому

      There is a fuse, maybe it has blown. Give Jandy a call and they can help you.

    • @enriquevega3855
      @enriquevega3855 3 роки тому

      @@SPL can I install a jandy heater with easy touch pentair?

    • @SPL
      @SPL  3 роки тому

      @@enriquevega3855 Yes I am pretty sure. Give Jandy a call just to be sure: 800-822-7933

  • @donkeywhistler
    @donkeywhistler 3 роки тому +2

    this comment section is just a bunch of people looking for free advice from a professional LOL

    • @SPL
      @SPL  3 роки тому

      LOL. So true. 👍

  • @that.damnpanda548
    @that.damnpanda548 Рік тому

    I broke into my neighbors house and this is not helping me

    • @SPL
      @SPL  Рік тому

      LOL. Unless your serious. 🤔