How to connect Weber Genesis II Natural Gas Connection - DrB DIY

Поділитися
Вставка
  • Опубліковано 19 чер 2021
  • Please subscribe for more from DrB DIY!
    DIY connection of Weber Genesis II grill with a natural gas 3/8" quick connect a hose to a new home natural gas 3/4" pipe. The Weber 2 grill was purchased in 2020 from Home Depot. Black pipe parts were purchased at HD also. A single adapter was nit in stocks.
    Video recording by Andrew.
    Here are the links to the parts:
    3/8 in. x 2 in. Black Steel Nipple 032888992634
    www.homedepot.com/p/Mueller-G...
    1/2 in. x 3/8 in. Black Malleable Iron Hex Bushing 032888407046
    www.homedepot.com/p/1-2-in-x-...
    and one of the two below, we bought both, but I think we used the 3/4"
    3/4 in. x 1/2 in. Black Malleable Iron FPT x FPT Reducing Coupling 032888406971
    www.homedepot.com/p/3-4-in-x-...
    1 in. x 1/2 in. Black Malleable Iron FPT x FPT Reducing Coupling 032888406988
    www.homedepot.com/p/Mueller-G...
  • Навчання та стиль

КОМЕНТАРІ • 104

  • @nofantasyman
    @nofantasyman Рік тому +9

    i appreciate showing every step in the way. some videos will skip the steps they they think everyone would take for granted. but many of us are novice and need the detail. good video. thanks

    • @DrBDIY
      @DrBDIY  Рік тому +1

      Thanks! I am the same way. I document the project in some detail so I can remember the next time !!!

  • @NSanto-bx7xs
    @NSanto-bx7xs 2 роки тому +12

    Thank you so much for this video! I'm in Dallas and have a natural gas line coming outside just like yours and you gave me the confidence and correct parts to go purchase to finally make this project happen. No more propane tanks, woohoo!

    • @DrBDIY
      @DrBDIY  2 роки тому

      Outstanding ! Grill on.

    • @liftcarry123
      @liftcarry123 5 місяців тому

      Same city; same situation right here.

  • @SQLTalk
    @SQLTalk 2 роки тому +1

    Exactly what I was looking for. 3/8"! Thanks.

    • @DrBDIY
      @DrBDIY  2 роки тому

      Glad I could help!

  • @oldtimefarmboy617
    @oldtimefarmboy617 2 роки тому +34

    Pipe fittings are tapered. The tighter you get the joints the more closer to each other the threads become. You do not need both pipe tape and pipe dope. Their only purpose is to seal any minuscule irregularity that might be present and to lubricate and prevent seizing of the threads against each other when fully tightened which will make them easier to disassemble should that be necessary.

    • @DrBDIY
      @DrBDIY  2 роки тому +6

      Don't need both. But we usually use both as a practice.

    • @nphoenixcrimefighter
      @nphoenixcrimefighter 2 роки тому

      Which do you recommend? Tape or Dope?

    • @aldocruz9249
      @aldocruz9249 2 роки тому

      I was just about to ask that should I put both?

    • @oldtimefarmboy617
      @oldtimefarmboy617 2 роки тому +6

      @@nphoenixcrimefighter
      Teflon tape works well but it has to be wrapped in the proper direction or the tightening fittings will pull it off and create the very gaps you want to seal, that and if you put too much on you risk cracking the fittings.
      The dope is a paste, which I find easier to put on because it does not matter what direction you apply it, and you do not have to worry about it tearing and you can be certain that it will flow into and fill the threads as they are tightened with any excess squeezed out.

    • @jaysantos536
      @jaysantos536 Рік тому

      @@nphoenixcrimefighter Both

  • @arthurq1
    @arthurq1 Рік тому +1

    Just what I needed thanks!!

  • @inc55
    @inc55 2 роки тому +2

    Thank you for this video. I have a new construction build and just got a Weber spirit NG Grill. This helps a lot. BTW after the gas Teflon tape, what is that stuff you put on the treads over the Teflon?

    • @DrBDIY
      @DrBDIY  2 роки тому +1

      You can use pipe thread sealant or pipe dope or similar.

  • @peterwang69000
    @peterwang69000 6 місяців тому +1

    Nice Video. One thing to mention. Try to avoid using a bushing to connect to your gas supply. Most states don't consider a bushing up to code for this type of application. A bell reducer would be the better option.

    • @DrBDIY
      @DrBDIY  6 місяців тому

      Great point! Wish they had them in stock at HD at the time.

  • @mmjaxstang
    @mmjaxstang 5 місяців тому +1

    Thanks for the video. My home uses LP. Would the reducing couplers and fitting be the same or do I need to use NPT?

    • @DrBDIY
      @DrBDIY  5 місяців тому

      Its all pipe threads. You may find a one piece coupler also, but for us they were sold out.

  • @Seabass1206
    @Seabass1206 19 днів тому +1

    did you change the orfice? sometimes they come with the propane one

    • @DrBDIY
      @DrBDIY  19 днів тому

      No, this is natural gas at the house and grill. The store usually carries a one piece adapter, but the adapter wasn't in stock.

  • @kenbrake2828
    @kenbrake2828 2 роки тому +12

    I think it needs more pipe dope!

    • @DrBDIY
      @DrBDIY  Рік тому +1

      An oldie but goodie comment !

  • @mayeri3083
    @mayeri3083 2 роки тому +2

    Great video.
    Thanks. Exactly what I needed. Except my connection from my home is already a female fitting meaning I don't need that wide black round shaped fitting. I have an 1/2 inch plug, which I would assume that means the line coming from my home is a 1/2 inch fitting and would require a double sided 1/2 inch fitting or whatever size my quick connect hose would be.
    Just curious what's the reason you used that small little black ring ? To downgrade or upgrade the size to accommodate the other fittings? Cam I technically use the double ended threaded pipe going directly into my line from my home to my quick connect hose? Or shall I put the small black nut you put? As well am I supposed to use yellow Teflon tape aside for my pipe dope? Do I need both? I rather be on the safe side.
    And curious if you did the same on the grill end where the hose attached to the grill. You didn't video that part.
    Otherwise great video thanks a ton for helping me out.

    • @DrBDIY
      @DrBDIY  2 роки тому +3

      Yes, black ring to downgrade size. We didn't have time to find an all in one size and shape adapter. We used Teflon on all connections except the last where the hose from the grill connects to its own adapter. That is spring loaded. On the grill side, I seem to recall that it was already connected. But if not, I would use Teflon there also. I always seal my brass and metal connections.

  • @matthughbennett989
    @matthughbennett989 Рік тому

    What size orifice does the Genesis II natural gas grill use?

    • @DrBDIY
      @DrBDIY  Рік тому

      Do you mean natural gas to propane conversion or the host to the wall?

  • @iansutanto3408
    @iansutanto3408 11 місяців тому +1

    What's that paste your're putting on? Is that really needed or just the yellow teflon tape?

    • @DrBDIY
      @DrBDIY  11 місяців тому

      Pipe joint compound. Some people use tape, compound or both. Lots of opinions.

    • @Seabass1206
      @Seabass1206 19 днів тому

      its definitely needed, more important then the tape

  • @xxxjovit
    @xxxjovit 2 роки тому

    Great video.Thanks. Do we need a licensed technician to do this work or an house owner can do this, if he is a technicaly experienced person? I have same gas pipe with valve provided in patio. I live in Dallas. Please advice.

    • @DrBDIY
      @DrBDIY  2 роки тому

      I did it and I am just a DIY guy. I don't think you need to adhere to city code just for connecting the grill, but you can call your code people. It is a simple job. We are near Austin.

    • @xxxjovit
      @xxxjovit 2 роки тому

      @@DrBDIY Thank you for reply. Surely I will call. I am new in US and getting familiar with codes.

    • @jaysantos536
      @jaysantos536 Рік тому +1

      @@DrBDIY Austin requires permits for everything re: house construction/remodel including natural gas grill hook ups. Cost is $350 and it takes at minimum 5 weeks for a city inspector to get out to your property. I know a guy that was fined $1750 for not getting the permit!

    • @DrBDIY
      @DrBDIY  Рік тому

      Wow, crazy.

  • @dmitriifakirov1767
    @dmitriifakirov1767 6 місяців тому +1

    Do I need a gas regulator if I connect it like you?
    Thanks!

    • @DrBDIY
      @DrBDIY  6 місяців тому

      I am not an expert, but you can have an explosion or a fire without a regulator.

  • @myviews469
    @myviews469 Рік тому +2

    Wish yoiu would talk more about how you change the fitting on the grille to accommodate the hose ?

    • @DrBDIY
      @DrBDIY  Рік тому

      Thanks. I didn't change the fitting that came with the grill. See page 40 of: weber.mizecx.com/retrieve/s3/knowledge/uploaded/WEBER_LG/40441806/6334_40441806.pdf?AWSAccessKeyId=AKIAUA2JDF35TDNNDYWX&Expires=1678478649&Signature=00umpGhkkh8SyhhAZX0uzFWOun8%3D
      The fitting with the blue cap at 0:19 in the video came with the grill. It just screwed into the provided hose.

    • @myviews469
      @myviews469 Рік тому +1

      @@DrBDIY doesn't open up but theres no converting connection and can I use the same connection for the tank on the gas pipe from house if I piut female fitting ?

    • @DrBDIY
      @DrBDIY  Рік тому

      You should be able to connect the fitting from the grill into anything that gets is mated to your natural gas connection in the house. Use brass as it won't spark.

  • @josesalinas2162
    @josesalinas2162 2 роки тому +1

    Do you need a regulator for natural gas ?

    • @DrBDIY
      @DrBDIY  2 роки тому

      Everything is included with the grill except the connection to wall line as shown in video .

  • @dontdlay
    @dontdlay 2 роки тому +4

    great video, great to see how it was done, would be super helpful if you linked examples of what you were picking out at the store.

    • @DrBDIY
      @DrBDIY  2 роки тому +2

      Just added the links.

    • @dontdlay
      @dontdlay 2 роки тому

      @@DrBDIY thanks, it helps us not so familiar with these things. appreciate it.

  • @alejandrovelasquez4637
    @alejandrovelasquez4637 8 місяців тому +1

    would it work connecting a coupling directly to the valve? or would it be too short for the hose to click on properly?

    • @DrBDIY
      @DrBDIY  8 місяців тому

      We were helping a family member - few tools and HD didn't have a direct coupler. You can probably do better.

  • @Gino20202
    @Gino20202 2 роки тому +3

    I just got the same grill (if that’s a Genesis II 435) delivered yesterday. Interesting tho you say the quick connect from Weber is a 3/8? Mine is a 1/2. I have a 3/8 already on the gas line coming from the house so I’ll need to change that out. Wonder why yours is a 3/8 and mine is a 1/2 quick connect. Great video btw. One of the best I’ve seen detailing this.

    • @mikestrahan8028
      @mikestrahan8028 2 роки тому +5

      For others reading, the Weber 410/415/430/435 Quick Connect is a 1/2". The 310/315/325/330/335 are 3/8". This is per the Genesis II Manual.

  • @markgriffin5288
    @markgriffin5288 Рік тому +1

    Did i miss the connection at the grill?

    • @DrBDIY
      @DrBDIY  Рік тому

      Our hose was attached. Is yours not attached?

  • @daddydankmemes6260
    @daddydankmemes6260 2 роки тому

    Is it not better to use joint compound for the threads than the tape

    • @DrBDIY
      @DrBDIY  2 роки тому

      I used joint compound only at another location.

  • @botsman35
    @botsman35 24 дні тому +1

    I would put some raspberry jam over dope to be 100% sure.

    • @DrBDIY
      @DrBDIY  24 дні тому

      We would have if it worked and made the family member / homeowner comfortable with connecting his gas grill. The new gas grill sat for a year because city slicker was nervous about having his first gas grill in the suburbs. We soon grilled some veggies and wagyu strips.

  • @RandomVids519
    @RandomVids519 7 місяців тому +1

    1/2 hoses or 3/8?

    • @DrBDIY
      @DrBDIY  7 місяців тому

      3/8 hose end and adapter". We misspoke while searching for parts at HD. Also, HD didn't have all of the parts in stock or we could have reduced / connected in one part.

  • @lanceellison594
    @lanceellison594 2 роки тому +2

    And flip the tape around so there is tension on the tape

  • @nelsonherrera103
    @nelsonherrera103 10 місяців тому +2

    white pipe dope it for water plumbing not necessarily gas.. should be using yellow pipe dope on gas . Looks pretty tight?? LOL!!!

  • @v8monster186
    @v8monster186 2 роки тому

    whats stanley plier size?

    • @DrBDIY
      @DrBDIY  2 роки тому +1

      Stanley Hand Tools 12" Groove Joint Pliers and
      Crescent 10 in. Z2 K9 V-Jaw Dipped Handle Tongue and Groove Pliers

    • @v8monster186
      @v8monster186 2 роки тому

      @@DrBDIY could it possible to use 10'' instead of that 12"?

    • @DrBDIY
      @DrBDIY  2 роки тому

      @@v8monster186 Should be just fine. The pipe doesn't have a big diameter.

  • @oldtimefarmboy617
    @oldtimefarmboy617 2 роки тому +1

    Natural gas pressure up to the gas meter's regulator can be as high as 300 pounds PSI. Once it goes through the regulator the pressure is reduced to around 10 ounces PSI. A properly sized regulator can provide a volume of gas at 10 ounces PSI necessary to keep all of your gas appliances running at maximum gas flow all at the same time.

    • @j.r.richard8532
      @j.r.richard8532 2 роки тому +3

      Good Info::: BUT, out here in California 99% of the time the gas pressure in the mains and services are under 60 PSI. Yes there are a few scattered houses located near high pressure lines that could be as high as that but usually the Gas Co. out here will regulate it out at the street first and lower it down to 20 or 30 PSI into the service line up to the house. Oh, and not trying to be a smart A## but gas pressure is regulated into the house at between 7 to 9 inches w/c (inches water column) never expressed as ounces ... They use a simple U gauge with water in it to set to regulator at the meter.

    • @oldtimefarmboy617
      @oldtimefarmboy617 2 роки тому +2

      @@j.r.richard8532
      Done different in Texas. 7 to 9 inches of water column is equal to 12.1275 ounces to 15.5925 ounces of pressure per square inch. In Texas a regulator, at least for residences, is required to be between 9 and 12 ounces PSI. Even at 60 pounds PSI going in and 10 ounces PSI going out, that gives you a 96 to 1 ratio between the supply of gas to the meter and the gas from the meter which means it can easily handle the demand of all of the gas appliances in the house all running at once. The only problem would be if you added gas burning appliances that would require a greater gas flow than the regulator was designed to supply to the house. Then the ratio would not make a difference.
      An example would be a laundry mat close to where I live. They had mostly smaller single load dryers but replaced them with larger multi-load driers. They failed to calculate what the gas flow to those new driers would be compared to what the regulator was designed for. The result was that if all of the larger dries were running at once the gas pressure would drop low enough that the pilots went out and the burners shut down and none of the driers would be able to heat the air going through the clothes. So for about a week they had to restrict the number of driers that could be used until the regulator could be replaced and certified by the city and the gas company.
      As far as the gas in the supply mains is concerned, the restriction to the flow of gas increases with distance so their is a limit to the number of residences that can be hooked up to that main over a distance. If the keep those lines with that pressure on them and there are a lot of residences to supply in that given area then they would necessarily have to have multiple shorter sections coming off either a much bigger pipe or a significantly higher pressure pipe.
      The lower pressure main would be safer in case of a rupture since less pressure would mean less gas escaping but a single higher pressure main would be able to supply gas to a lot more residences with a single run of pipe.
      Either way works.

    • @j.r.richard8532
      @j.r.richard8532 2 роки тому +1

      @@oldtimefarmboy617 Wow...." California man gets his butt kicked (figuratively)by Texan " Thanks Man ,kind of felt good ! If I ever get over to Texas I'll look you up and we can drive around and look at gas meters....

  • @Sazonman
    @Sazonman Рік тому +1

    What happen to the dripper pipe, doesn't it require one

    • @DrBDIY
      @DrBDIY  Рік тому

      Dripper?

    • @Sazonman
      @Sazonman Рік тому +1

      @DrB DIY the stubby small pipe that collects the small amount of gas 💧 or rust, whichever🤣😂🤣😂

    • @DrBDIY
      @DrBDIY  Рік тому +1

      Sediment trap? Not required in Texas.

    • @Sazonman
      @Sazonman Рік тому +1

      @@DrBDIY thank you for answering my question

  • @AereForst
    @AereForst Рік тому +2

    Did you not use a conversion kit? Doesn’t it require switching out the orifices and getting a natural gas regulator?

    • @DrBDIY
      @DrBDIY  Рік тому +1

      Weber sells both propane and natural gas equipped models. This was a natural gas model so all equipment is included.

    • @AereForst
      @AereForst Рік тому +1

      @@DrBDIY Thanks. I found a natural gas conversion kit specifically for my Genesis II-S345. I hope it works.

    • @matthughbennett989
      @matthughbennett989 Рік тому

      @@AereForst Where’d you find it? What were the orifice sizes?

    • @AereForst
      @AereForst Рік тому

      @@matthughbennett989 Oh and by the way the natural gas conversion kit works perfectly! Save yourself a ton of headache in the long term by just doing the conversion. Natural gas is also cheaper

    • @matthughbennett989
      @matthughbennett989 Рік тому

      @@AereForst Where’d you find it? What size were the orifices? Did you have to replace the manifold too?

  • @austinrhodesw2820
    @austinrhodesw2820 5 місяців тому +1

    Ur taping backwards it just un rolls itself as u tighten

    • @DrBDIY
      @DrBDIY  5 місяців тому

      Taped clockwise.

  • @IM-A-TUA-DISCIPLE
    @IM-A-TUA-DISCIPLE Рік тому +2

    Your not supposed to use bushing on gas

    • @DrBDIY
      @DrBDIY  Рік тому

      How would you suggest we reduce he pipe to fit to a grill?

    • @racgrac28
      @racgrac28 Рік тому +1

      @@DrBDIY 3/4 in. x 3/8 in. Black Iron Reducing Bell Coupling

  • @donf3739
    @donf3739 26 днів тому +1

    Good grief!

  • @jg-aerialvideos1370
    @jg-aerialvideos1370 8 місяців тому +3

    Teflon tape AND pipe dope??? Explained as “double seal”. I’ve never heard of this... Inappropriate use of tools. Should have used pipe wrenches on the galvanized pipe and a crescent wrench on the brass fittings.

    • @DrBDIY
      @DrBDIY  8 місяців тому

      We were helping a family member get the grill installed quickly for cooking without many tools onsite.

    • @elmagnificodep
      @elmagnificodep Місяць тому

      Why do know if all people watch tutorial videos?

    • @thomasblassick6960
      @thomasblassick6960 Місяць тому

      Glad someone else was thinking it too 😅

    • @Seabass1206
      @Seabass1206 19 днів тому

      its not a service call bud😂😂😂

  • @Ted_Michaels
    @Ted_Michaels 3 місяці тому +1

    You did not show how the hose connects/disconnects from the grill! - I gave you a thumbs down.

    • @DrBDIY
      @DrBDIY  3 місяці тому +1

      Fair enough, but that just snaps in.

    • @mvman4122
      @mvman4122 2 місяці тому +1

      @@DrBDIYsome people are very hard to please