Airtight Home Ventilation for the 21st Century with Fantech: Kitchen Exhaust, Make Up Air, Radon etc

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 202

  • @frankgall6
    @frankgall6 5 років тому +6

    20 min Corbett video about ventilation!!!?? I can die happy

    • @HomePerformance
      @HomePerformance  5 років тому +2

      Please don’t die. The world needs you so bad.

  • @mannyjr2912
    @mannyjr2912 5 років тому +6

    Great video, I a builder and mechanic contractor, I love the idea of tight homes and this equipment is a must, in NJ I have very limited work using any of it, people think I’m nuts when I start talking about it. Thanks for the time to make the video great job, I also used thermal buck and blue skin on my house, and 2” of ComfortBoard 80 on the exterior, love passive homes.

    • @HomePerformance
      @HomePerformance  5 років тому

      Nice, Manny! Thanks for following, and keep up the good work- the world needs you.

  • @davidfleuchaus
    @davidfleuchaus 5 років тому +4

    Phil Rivas - Fantech 0:07
    1:26 Overview
    Exhaust ventilation.
    Purification and filtration.
    Air exchange and whole house ventilation.
    Pressure balancing
    1:47 Radon System (in-line fan, EC)
    2:57 Kitchen Exhaust - remote-mount (noise outside) fan with duct sound dampener, hood liner.
    5:14 Dryer Booster.
    6:18 Auxiliary Lint Trap
    7:21 HEPA Filters, taking particles out of the air. Pre-filter, activated carbon filter, two year HEPA filter (traps 99.97% of particles larger than 0.3 micrometers)
    10:05 Whole Home Ventilation
    10:43 ERV Core
    11:52 Ports in/out
    13:41 Fittings
    15:21 Make-Up Air System
    16:02 Controller
    17:00 Intake Vent w/ screen
    17:12 motor-controlled variable Damper
    18:08 Fan (EC, infinitely variable)
    18:25 Filter Box
    19:17 Homeowner Maintenance
    20:11 Duct Dampener/Silencer
    20:47 Heater & Controller
    23:27 Verification Testing later
    On average, women and men need to consume about 11 & 15 cups of water from all sources each day. Probably 8 or less cups is from glasses of treated water. On average, we breathe the equivalent of about 2000 gallon bottles of unfiltered air each day. 0:53

  • @hoatam5213
    @hoatam5213 2 роки тому +9

    *Works great with **Fastly.Cool** ! Love all the features offered! Multidirectional, temperature controlled and various speed settings! This is our third of this product!*

  • @technorex344
    @technorex344 4 роки тому +1

    I'm really happy I finally found a channel that recognizes ERV as the more effective system for most climates.

  • @vansage2691
    @vansage2691 5 років тому +14

    The amount of information hear is overwhelming. Great presentation and you might be on your way of surpassing ol Matt Risinger.

    • @davidfleuchaus
      @davidfleuchaus 5 років тому +1

      There is definitely a lot presented in this video. Check out my comment where I broke it down.

    • @HomePerformance
      @HomePerformance  5 років тому +9

      Thanks Van! Matt has a different thing, I think there’s space for everybody.

    • @RoyKimYYZ
      @RoyKimYYZ 4 роки тому +2

      ​@@HomePerformance Great video and I agree the information was overwhelming. Be great to do a follow up video and understand how those components work as an overall system. Along with a simple diagram. For example, I'm not that clear on which equipment helps with balancing pressure with drawing air from the outside. Keep up the good work.

    • @HomePerformance
      @HomePerformance  4 роки тому

      Stay tuned, Roy- you’ll understand more when we get to the installation.

    • @justinlee4022
      @justinlee4022 4 роки тому +1

      One other point as well... when you bring in a “expert” and a “guest” . How about letting him take the show and explain things in detail and all the info. 90% of the time he spoke, it was a sentence and then he was interrupted and you over explained the item and made jokes in the meantime. That’s why people are saying it’s overwhelming. Fast talking, jokes , competing with him for talk time and over explaining real fast just to get to another item.

  • @kylemacht
    @kylemacht 5 років тому +7

    Corbett, this is probably my favorite video of yours. Well done, some really good information for professionals and homeowners. One question, are you using a regular dryer or have you considered a heat pump dryer? We are typically recommending heat pump dryers in all our projects since they don't have an exhaust. They do take a little longer to dry, but about 50% longer, not 6 hrs like it use to be. Thank you!! FYI, I will have to remember the 2,000 gallons of air a day, I've never heard it in those units, about 30 lbs of air per day. I think cups are a much better idea that a client could relate to.

    • @stevepailet8258
      @stevepailet8258 5 років тому +1

      gallons not cups

    • @HomePerformance
      @HomePerformance  5 років тому +1

      Thanks a lot, Kyle! It’s 2,000 gallons, btw, not cups. If 8 cups of water = 1 gal, that would mean 16,000 cups of air per day

    • @kylemacht
      @kylemacht 5 років тому +1

      @@HomePerformance Thanks, for the clarifications, I edited my reply to avoid further confusion.

    • @dennmillsch
      @dennmillsch 4 роки тому +1

      @@HomePerformance except 1 gallon = 16 cups

  • @michaelvangundy226
    @michaelvangundy226 5 років тому +1

    When you said that it was going to be a high performance exhaust system I was expecting more. Way back in the non computer days we ran all of the exhaust system into the attic. At the bottom was a condensation drain piped to a trap then outdoors. The main feature had a freon heat exchanger to save heat. Preheating the fresh air inlet. This system also was balanced to have 15% fresh air into the return air system. One outlet and one inlet. The inlet had a rolled filter at the inlet. Then pleated filter at the plenum. The kitchen exhaust always ran out as short as possible. We sheetrock ed a box with fire x on the inside. The idea was if it accumulated grease and had a fire, would it spread it or contain it? Last, was a power interrupt to the smoke detectors. One inside the exhaust air and two or three inside the home. They go off and shut down all fans.
    On a side note. Did you test for Radon?

  • @tealkerberus748
    @tealkerberus748 7 місяців тому

    I appreciate the respect for not making the woman's feet cold. One of the interesting discoveries that has arisen from the broader accessibility of hormone support for transgender people is that women's hormones restrict blood supply to the extremities more than men's hormones do. Women having cold feet is a real thing, and it's part of our survival-oriented physiology because we're better at keeping our core temperature stable, but also cold feet are uncomfortable and designing houses to keep them warm is IMPORTANT.

    • @HomePerformance
      @HomePerformance  7 місяців тому

      Well said, but I will remind us all that this make up air has a heater built in. We do not blow cold air on toes here.

  • @paulmaxwell8851
    @paulmaxwell8851 Рік тому +1

    Very interesting! To make the story re restaurant air (at 17:50) more complicated, make-up air supplies are generally set up to supply 90% of the air being exhausted by the range hood and dishwasher fans. Where does the other 10% come from? The dining area. This is so cooking smells, smoke etc. stay in the kitchen. The building's HVAC system, separate from the kitchen system, supplies that 10%.

  • @torempilor
    @torempilor 5 років тому +1

    Can't wait to see the installation!

  • @jeffgaufin2606
    @jeffgaufin2606 5 років тому +4

    Great video really appreciate the longer-form videos going into the less well understood parts of building a high-performance home. Did you have a mechanical engineer draw out the entire system?

    • @HomePerformance
      @HomePerformance  5 років тому +2

      Not a mechanical engineer- just a good engineer-minded res expert

  • @someOneYouKnow6506
    @someOneYouKnow6506 2 роки тому +1

    this is my favorite video of fresh air systems.

    • @HomePerformance
      @HomePerformance  2 роки тому

      Wow, thanks Anthony- sounds like you’ve seen a few

  • @erikthie2253
    @erikthie2253 3 роки тому +1

    the one thing i would love for all of this technology is for it to check itself if there is a problem and email the home owner when it needs servicing. annual service is one thing, but if it breaks or stops working in the middle of a cycle, you may not know unless you are constantly checking them. for example, the heater for the fresh air intake. if it stops, all of sudden it is cold one day and it may have broken 3 months ago.

  • @AndrewAliferis
    @AndrewAliferis 3 роки тому +1

    A great video with tons of very useful information! Thank you for such a detailed presentation on this most important topic, Corbett and Phil.

  • @lenbloom338
    @lenbloom338 Рік тому +1

    The ERV manufacturers that we have been looking at expressly say that the ERV equipment should not be installed in a bathroom. We didn't understand that because, as you've pointed out, the ERV is built to handle the high moisture. Is the Fantech ERV different somehow to make the installation possible in a bathroom?
    Your videos are an amazing resource. Thank you very much.

    • @HomePerformance
      @HomePerformance  Рік тому

      Thanks Len- you should think about another manufacturer, they don’t sound legit.

  • @brianchadwick9405
    @brianchadwick9405 5 років тому

    We used these dryer booster systems and they work well. With the lint filter.
    We can no longer use a dryer booster with the motor in line. They make another version.

    • @justinlee4022
      @justinlee4022 4 роки тому +1

      Brian,
      I don’t know that much about these newer systems. However I was literally just on the website reading the brochure and data specs on the unit. It says in bold “do not run the exhaust ducts from the kitchen or bathroom straight to the ERV”... Hope that helps .

    • @HomePerformance
      @HomePerformance  4 роки тому

      I think he meant because of codes where he lives, but yes.

  • @AdayintheLifeofsmith
    @AdayintheLifeofsmith 5 років тому

    Only thing you could use to improve your erv system is posh timer kit from eneready from Vancouver BC. Motorized exhaust grilles, With touch sensitive wall controllers. You will like it!

  • @jessicacabanilla1524
    @jessicacabanilla1524 4 роки тому +3

    Can one of you teach at my university you’re much more helpful than my lecturers

    • @HomePerformance
      @HomePerformance  4 роки тому +2

      Haha, I’d actually love that- I do guest speaking, if you’d like to ask your school

  • @dennmillsch
    @dennmillsch 4 роки тому +2

    Nice video. Very helpful to me. Now you just need to make a video showing the design of the system and also installation methods. That'd be way cool.
    Not sure what the point was around 08:00 regarding a humid summer, a clogged filter and "not enough air flow across your coil." I'm assuming "coil" is referring to the cooling coil in an air conditioner trying to dehumidify the indoor air? A second trivial point is at the beginning the mention of drinking 8 cups of water per day while text on the screen says "1 Gallon per day." But 1 gallon = 16 cups !!!

    • @HomePerformance
      @HomePerformance  4 роки тому

      Cups like glasses full, sorry for the confusion. Yes, we have TONS of videos on ventilation design, search our channel and you can go down the rabbit hole. And yes, coil means A/C coil. Installation vids coming soon!

  • @cranbers
    @cranbers 3 роки тому +3

    Love to hear the total cost for all this stuff installed. im guessing 30k at least.

    • @HomePerformance
      @HomePerformance  3 роки тому +2

      HAHA Chad! You'll be happy to hear the total MSRP for everything in this video is $7719.

    • @23lkjdfjsdlfj
      @23lkjdfjsdlfj Рік тому

      @@HomePerformance $17,000 USD to install an ERV in my home.

  • @kuklachica
    @kuklachica 5 років тому +4

    You said you'd mention bath ventilation, but I didn't hear anything about that? Can you comment on what is happening with humid bathroom air?

    • @HomePerformance
      @HomePerformance  5 років тому +2

      All the bath exhaust goes through the ERVs.

    • @tweake7175
      @tweake7175 5 років тому +1

      @@HomePerformance wouldn't that create a moiture spike around the house?

    • @HomePerformance
      @HomePerformance  5 років тому

      No, the ERV is a buffer

    • @tweake7175
      @tweake7175 5 років тому +1

      @@HomePerformance can you explain that please? erv are rare here.

    • @HomePerformance
      @HomePerformance  5 років тому +1

      5 Types of Ventilation for Controlling Your HOMEChem
      ua-cam.com/video/_2uuOB5P6eI/v-deo.html

  • @pchangover1435
    @pchangover1435 5 років тому +6

    What is the filter cost for these systems a year?
    Also I love the idea of it all but as an average consumer with limited building experience this seems kind of daunting.

    • @HomePerformance
      @HomePerformance  5 років тому +4

      Change the HEPA filter every 2 years- about a hundred bucks a pop I think

    • @turboflush
      @turboflush 3 роки тому

      Yah its a bit much for average people. I am shooting for a lesser version. Its a bit of a struggle.. And costly.. But i am sure i will achieve desirable in the end.
      Spray foam top and bottom sealing the house and providing space for the hvac to be in conditioned space. I hate walking around a house and feeling hot air sudenly come out of the duct or hot spots because the system is not matched. In my area.. Most just want to toss something in. They give a price within 10min.

  • @albertoarriaga9611
    @albertoarriaga9611 5 років тому +2

    Great video!! What do you think of running kitchen exhaust through the ERV and installing a recirculation hood vent, would that take care of the grease particles and reduce/prevent clogging of the ERV core?

    • @HomePerformance
      @HomePerformance  5 років тому +2

      No, I don’t buy that solution. The amount of tiny particles created by any form of cooking will not be caught by a simple grease trap. They’ll end up on your surfaces and in your body.

  • @gloriaalkins3589
    @gloriaalkins3589 3 роки тому

    Finally, a great in-depth discussion about home ventilation systems! So appreciated and agree that you need to research this stuff "exhaustively"! Love the pun! So, what type of kitchen exhaust fan besides bowl shaped is best? How much CFM extraction rate max is recommended? No recirculating types, right? Just outdoor venting types, right? Also, I read that mounting a kitchen fan about 2 feet above the cooktop is most efficient. Your thoughts? And induction cooktops only (not gas). And clothes dryers...we have a condensing dryer, so we don't need to vent externally. The guts of the house are critical, yet people spend so much time focussing mainly on the aesthetics. With climate change and the dangers it poses, we all need to change our thinking when constructing new buildings of any sort. Thank you for sharing your knowledge on and passion for this important topic.

    • @HomePerformance
      @HomePerformance  3 роки тому

      Thanks for your comment, Gloria, and you definitely get the gist! Mounting height is based on manufacturer recommendations, though, because you might overheat or melt the electronics if you go too low (2 ft is pretty low). CFM is less important than Capture Efficiency, which we'll get into more here in future videos.

    • @robertwilliams1473
      @robertwilliams1473 2 роки тому

      Depends if it is gas or electric cooktop and then the BTU.

  • @gloriaalkins3589
    @gloriaalkins3589 3 роки тому +1

    With regards to humidity, at what point does an HRV system make sense? I read that a climate with over 60% humidity would require an ERV, but HRV is fine with less humidity. Your thoughts?

    • @HomePerformance
      @HomePerformance  3 роки тому +1

      I prefer an ERV for virtually every single scenario, Gloria, because of this:
      ua-cam.com/video/QOe4lluGwCg/v-deo.html

  • @andreycham4797
    @andreycham4797 5 років тому +1

    1. I would put a heat pump for a water heater in my crawl space. A heat pump sucks radon, moister from that space and saves me money on electricity 2. instead of buying a buster for a dryer I buy a dryer with built in heat pump. The difference in price v.s. a traditional dryer will be covered in 3 years with savings on electricity and that dryer do not need exhaust at all. 3. I install Chinese made multi splits with operating mode down to -22 F by doing so i get 2 in 1 heating and cooling where cooling 2x less expensive than from a traditional system. 4. since I save lots of money on heating and cooling systems I could consider installing CERV2 which is superb any HRV and ERV or I probably wait when Chinese product come to US market . 5. after all my projects complete I could estimate how much electricity my household consumes and install solar panels

    • @HomePerformance
      @HomePerformance  4 роки тому

      Thumbs up, Andrey, except for the part about a heat pump water heater sucking radon away- never happened.

    • @andreycham4797
      @andreycham4797 4 роки тому

      @@HomePerformance if you direct exaust from a water heater outside , it will

    • @HomePerformance
      @HomePerformance  4 роки тому

      I’d want to see some test data on that before I bought it

    • @kirkellis4329
      @kirkellis4329 4 роки тому +2

      @@HomePerformance A typical heat pump water heater moves at least 100cfm and can have its intake and/or exhaust ducted. Why wouldn't ducting from the crawl space suck up radon and then exhaust it outside after the heat has been extracted from the air carrying the radon away ?

  • @smccoy
    @smccoy 5 років тому +1

    Great video. I may have overlooked it on a previous video, but why no whole home dehumidifier? Are you expecting the ERV to control humidity entirely?

    • @HomePerformance
      @HomePerformance  5 років тому +2

      Coming in a separate vid within the coming weeks, Stephen! Ultra-Aire XT105 and MD33.

    • @smccoy
      @smccoy 5 років тому +1

      @@HomePerformance Awesome! Thanks for the quick follow-up. I can't wait to see how you tie the Ultra-Aire into this ventilation setup.

  • @frankstrack7980
    @frankstrack7980 9 місяців тому

    768 sq ft house main 8’ 3.5” 2x6 walls vaulted ceiling 12’6” 16’x24’ total 24’x32’ master bedroom 12x12with 8’3.5”x 12.6” one master bath 6’x11’6” 6’x6’ laundry heat and air 750sq ft mini split Mr cool.
    What size Ervin would you need?

  • @beurky
    @beurky 5 років тому +2

    Awesome vid. I love fantech products but it's good to see some of the thngs they jave for specific systems.
    Also, I have the sexy black fan as well. Let me tell you, its a scookum blower.

    • @HomePerformance
      @HomePerformance  5 років тому

      When you need a scookum blower, no other blower will do

    • @paulmaxwell8851
      @paulmaxwell8851 2 роки тому +2

      @@HomePerformance That's 'skookum', which is a Chinook word for strong, or fierce. We older Canadians use that word a lot here in western Canada, although no twenty-year-old does. The younger set just rolls its eyes!

    • @HomePerformance
      @HomePerformance  2 роки тому +1

      I’m absolutely adopting that word Paul, thanks! Keep the Chinook geezer lingo coming!

  • @Mattox1231
    @Mattox1231 Рік тому

    I think I heard you say you'd talk about the bathroom exhaust but I don't recall hearing about bathroom exhaust and makeup air for the bathroom. In addition, how does the makeup air activate for your dryer fan if it is connected to your range hood? Great video overall.

    • @HomePerformance
      @HomePerformance  Рік тому +1

      Thanks Mike- bath exhaust pulled by ERV. And we went with a heat pump dryer.

  • @simplifaster8065
    @simplifaster8065 Рік тому

    Great video. Regarding the dryer, you mentioned the potential need for a booster, and you said you would get to the makeup air for the dryer, but the video only discusses the makeup air for the kitchen hood. Given a super tight home, how do you plan to provide makeup air for the dryer? Is the makeup fan for the kitchen hood also monitoring the dyer vent?

    • @jamesphillips2285
      @jamesphillips2285 10 місяців тому

      Yes. They mentioned several times that the makeup system would have to work harder if the dryer came on.

    • @HomePerformance
      @HomePerformance  10 місяців тому +1

      Hey guys, to clarify we went with a heat pump dryer because there is no single solution on the market (or even theoretically possible) that would work for this whole house pressure control. Video forthcoming.

  • @mattbram8993
    @mattbram8993 8 місяців тому

    What a great video!

  • @stevepailet8258
    @stevepailet8258 5 років тому +1

    Was a bit confused about the last bit of the video where you were bringing in fresh air to help balance the system. Is this to provide positive air pressure to the house when you are using something like the range hood, where it goes beyond the normal erv

    • @HomePerformance
      @HomePerformance  5 років тому +4

      Yes, exactly. Anytime an exhaust-only fan is used, the makeup system activates.

  • @kirkellis4329
    @kirkellis4329 4 роки тому +1

    Are there any ventilation systems that would route the clothes dryer, bath and kitchen exhaust air to a heat pump (water heater or otherwise) to recapture the energy before it leaves the house ? It seems like running that 6kw heater for the kitchen replacement air is not energy efficient. Especially if you are like me and cook for hours at a time every day. That heater must need its own 30A 220V circuit ?

    • @HomePerformance
      @HomePerformance  3 роки тому

      Yes, the heater takes that circuit size. Full vid on that system coming soon- stay tuned.
      And I'm aware of no systems that would reclaim the heat loss from all of those without being a major headache on maintenance. Heat pump dryer works great though.

  • @chazTRAINalb
    @chazTRAINalb 5 років тому +1

    Building a 2000 sq ft house for my family down in McDonough ga. What’s the cost for a system like this? Seems like it’d be out of reach for most people. Thanks, I’ve been really enjoying these videos. 🤙

    • @HomePerformance
      @HomePerformance  5 років тому

      What’s the cost for having humidity and chemistry problems in a house that makes kids sick and wives unhappy? If you want that stuff to be taken care of, it takes money. If you’re comparing the cost of this system to a couple of builder model bath fans, then you’re right, it’s out of reach.

    • @DocSawBlade
      @DocSawBlade 5 років тому

      Less than decades of heath issues, doctor visits and missed day of work or school.

    • @chazTRAINalb
      @chazTRAINalb 5 років тому

      @@HomePerformance Yea I get it. I plan on using a legitimate ventilation system in my home (ERV). I guess what I'm asking is does it need to be as complicated as this to provide "fresh" air to the occupants?

    • @jasonarmstrong4556
      @jasonarmstrong4556 5 років тому

      @@HomePerformance I understand the need, but what are the hard numbers?

  • @lee-johnson
    @lee-johnson 5 років тому +2

    Iv'e used and installed fantech for years. Great product. Not a cheap install there

    • @HomePerformance
      @HomePerformance  5 років тому

      You get what you pay for, right Lee?

    • @terryjennings1739
      @terryjennings1739 Рік тому

      @@HomePerformance What would the cost be for the systems you covered in this video? Is there an equipment list available?

    • @HomePerformance
      @HomePerformance  Рік тому

      It’s in another comment I believe, but it all came to around $5k

  • @rocky7gd
    @rocky7gd 5 років тому +1

    Where can i buy the enclosure with the carbon filter?

    • @HomePerformance
      @HomePerformance  4 роки тому

      Anywhere that distributes Fantech components, Guillaume! I believe they might even sell direct at fantech.net

  • @cynthiaarmstrong7972
    @cynthiaarmstrong7972 2 роки тому

    What is the feasibility/cost:benefit of using geothermal intake air to the makeup air system vs the 6KW intake air heater?
    Prob need multi buried intake pipes to a manifold system to feed that large intake fan box?
    I’m building a small off grid solar house with battery and diesel generator backup and 6KW would gobble up nearly all of the output of the panels and be worse at night when cooling dinner. Thanks for the excellent videos!

    • @HomePerformance
      @HomePerformance  2 роки тому +1

      Excellent question, Cynthia. Check it out:
      There are 3413 Btu in a kW, so a 6 kW heater produces 20,478 Btu. The size of a coil needed to get that much geothermal transfer is basically a 2 ton A/C. Probably too much to be feasible.

  • @bartraats2868
    @bartraats2868 Рік тому

    COP of heater is poor. Any chance to link to a multi-split A/C in heating mode?

  • @JuanHernandez-ti6su
    @JuanHernandez-ti6su 2 роки тому +1

    Hello, I was to install LED UV in my AC. now I concerned that it could cause a chemical reaction? Looking to reduce allergies for my babies. Any suggest are welcome.

    • @HomePerformance
      @HomePerformance  2 роки тому +1

      I suggest you don’t risk it, Juan. Install better filtration like an Aprilaire MERV 13 or even 16 if you like, but avoid adding chemistry.

  • @josephmerritt1411
    @josephmerritt1411 2 роки тому

    Nice video. I have a question concerning bathroom ventilation concerning humidity. In another video, you described two exhaust ports (one wall-mounted near the water closet and another ceiling-mounted over the shower/bathtub). Please share your experience so far with the exhaust leg carrying humid air from the shower/bathtub back to the ERV? Are there any issues associated with condensation?

    • @HomePerformance
      @HomePerformance  2 роки тому

      No issues, though I’m not sure what concerns you specifically. The ERV core is made to deal with humidity.

    • @josephmerritt1411
      @josephmerritt1411 2 роки тому

      @@HomePerformance I am planning to follow your path and since my building will start soon, it seemed a good time to learn from someone using the system. Your videos have been very helpful. With any home, my largest fears are stormwater and condensation so that's why I asked. Thanks again for sharing your build.

  • @abel5925
    @abel5925 5 років тому +2

    Fantech is so great

    • @abel5925
      @abel5925 5 років тому +1

      Wow this is such a legit setup

    • @HomePerformance
      @HomePerformance  5 років тому

      Thanks Abe, we think so too

  • @beckysmith7517
    @beckysmith7517 3 роки тому

    Hey
    I have a question? I have a 200 square
    foot tiny house with closed foam insulation and because I also use it as a greenhouse
    in the winter time and of course because of transpiration of the plants and
    evaporation of the soil after a watering… on top of two adult people breathing,
    I am getting a lot of humidity in the winter time. I also live in the SW Virginia area so we
    have pretty humid summers here too. Which
    system would work best for this application and HRV or ERV? I know both clean the air Im just more
    concerned with excessive humidity. I see
    a lot of people in tiny houses using HRV but what do you think I should
    do. Also I am looking for a very small
    unit… any ideas there because its again only 200 sq ft?

    • @HomePerformance
      @HomePerformance  3 роки тому

      Hi Becky- thanks for your message, but you're not going to like my answer. A home and a greenhouse are totally different things, and should never be combined. You need two separate spaces. There is no way I know of to maintain a steady humidity level when you're watering a ton of plants in a tiny home.

  • @TrogdorBurnin8or
    @TrogdorBurnin8or 5 років тому +2

    Love the video. Here's my POV: We're radically under-investing in filtration - even the people like you who care about filtration. Why? Because we're counting on homeowners to replace filters frequently - somewhere between monthly and annually. This is not realistic, and all the folks over at the HVAC subreddit talk about how ubiquitous clogged filters are. Not only do clogged filters choke off your HVAC system, even when things are working well relying on one small filter forces your fan to waste tons of energy & noise trying to push air through such a small manifold. I think the house should have a number of places with filter arrays: Take the biggest low-MIRV filter they sell at Home Depot and build a door-sized panel of a dozen of them. Slap a cyclone separator in front of that to get the big stuff (home woodworking shops are all using these now). Put another door of HEPA after all this. You trade that broom-closet-sized space in for a reasonable maintenance cycle and a reasonable energy usage for the ventilation fan - plausibly saving you more energy than entire classes of insulation.
    (This is part of the reason why small homes seem ridiculous to me: There are lots of opportunities to trade off space for efficiency, comfort, and performance)

    • @tweake7175
      @tweake7175 5 років тому +2

      why don't they have a pressure differential switch across the filter connected to a warning light ?
      i have that on the fan at work.

    • @HomePerformance
      @HomePerformance  4 роки тому

      They do, and we'll show one off on this house, Tweake.

    • @HomePerformance
      @HomePerformance  4 роки тому +3

      Interesting thought, but isn't the solution described just kind of a longer-term bandaid? What if we upped the stakes- if you don't replace your filter, the IRS finds out and audits you. Bam. Solved.

  • @canadalifevlog21
    @canadalifevlog21 Рік тому

    About the ERV. When you say most all kinds of climate from extreme hot and extreme cold weather. ERV IS STILL ADVISABLE? I have a serious problem with high condensation particularly when I'm cooking and showering. What is your recommendations. Please help?

    • @HomePerformance
      @HomePerformance  Рік тому

      Unless you’re in Miami or Alaska- yes, I’d recommend ERV over HRV.

  • @KeithMorgan
    @KeithMorgan 4 роки тому +1

    I am designing a house to build in NC [similiar to ATL climate] and am going the same direction you are. Curious about ducting. I am assuming you are doing a separate duct network for the ERV system yes? what about the makeup air? is it dumping into a single location? would it be possible to dump it into the ERV outlets?

    • @HomePerformance
      @HomePerformance  4 роки тому +1

      Yes, separate ducting, no, don’t mix ERV and makeup air. The ventilation rate for our living space is 150 cfm, but the makeup air goes up to 750 cfm when needed- way too much for a skinny little duct system.

    • @KeithMorgan
      @KeithMorgan 4 роки тому

      so are you just going to dump makeup air into a single register?

  • @BigAnil
    @BigAnil 5 років тому

    Corbett, can you post a model number list for what you are installing?

    • @HomePerformance
      @HomePerformance  5 років тому

      Sure, Anil- I’ll put it in the blog asap

    • @BigAnil
      @BigAnil 5 років тому

      Great, thank you Corbett! I had no idea that FanTech had a product line for all my needs.

  • @steveedlund7357
    @steveedlund7357 2 роки тому

    The kitchen Makeup system is interfaced with the exhaust system. What is the best way to provide makeup air for your dryer exhaust?

    • @HomePerformance
      @HomePerformance  2 роки тому

      Best way is not to have a dryer exhaust. Use a heat pump dryer.
      ua-cam.com/video/6nSGdcK1bqs/v-deo.html

  • @ericlebarron
    @ericlebarron Рік тому

    I was wondering about blowing makeup air in the kitchen when the outside air is freezing. A heater makes sense. I wonder about the exterior exhaust fan though, if it could have freezing issues when it's below zero and you're venting steam, etc. from cooking.

    • @HomePerformance
      @HomePerformance  Рік тому +1

      Have had no issue with the exhaust fan refusing to work for sny reason

  • @ghulands
    @ghulands 4 роки тому

    @Home Performance, What brand of range hood is that?

  • @BradleyFordAus
    @BradleyFordAus 2 роки тому

    Thanks for the video
    You talk about preheating the makeup air, but what about those of us in 35DegC temperature?

    • @HomePerformance
      @HomePerformance  2 роки тому +1

      Do you have an ice cave handy?

    • @BradleyFordAus
      @BradleyFordAus 2 роки тому +1

      @@HomePerformance haha ok. It just seems like a gap in terms of performance for hot weather people.
      Let me keep researching to figure out how to pre-cool it.
      (In Thailand everything is ductless inverter systems for AC)

    • @HomePerformance
      @HomePerformance  2 роки тому +4

      The secret is a short circuit. Introduce the uncomfortable makeup air as close as possible to the exhaust.

    • @BradleyFordAus
      @BradleyFordAus 2 роки тому +2

      @@HomePerformance ahhh that is a handy tip, bring it in but then suck it out again add quickly as possible instead of our high quality ERVed air 👍👍👍.
      Thanks for that

  • @tweake7175
    @tweake7175 5 років тому

    Any more info on the erv inlet and outlets? They look tiny. Thoughts on pressure vers vacuum in the house. Postive pressure hrv systems are common here but i hear depresserision is better in cold aeras.

    • @HomePerformance
      @HomePerformance  5 років тому +1

      Neutral pressure is best, imho. Yes, the grills are tiny- biggest flow for each is only 25cfm

    • @tweake7175
      @tweake7175 5 років тому

      @@HomePerformance so how many outlets per room? And hows that better than one big outlet?

    • @HomePerformance
      @HomePerformance  5 років тому

      One supply in each bedroom and living room, one exhaust per pollution source in bathrooms etc- helps with mixing

    • @tweake7175
      @tweake7175 5 років тому

      @@HomePerformance here we typically use 150mm vent for smaller rooms and 200mm for larger. Yours looks like 100mm. Are you going gor smaller size to increase throw?

    • @HomePerformance
      @HomePerformance  5 років тому +1

      This is a package, manufacturer designed the grills for these flows

  • @sureshbabu-zf8ew
    @sureshbabu-zf8ew Рік тому

    It's not as powerful as I thought it would be, but it works very well. ua-cam.com/users/postUgkxGjG43--gYqIoT4Xkur2PqCrtbKwTv2h6 There are three options to circulate air, and best of all a remote control for us lazy people. Installation was a breeze (no pun intended). It actually took longer to open the box then it did putting the side extenders on and sitting it in the window opening. It's a perfect alternative when you want airflow, but not the AC. Just might order another one for a different room. UPDATE: Bought another one like I said. They work great. Why not have two...

  • @steven7650
    @steven7650 5 років тому

    Why are you not running the kitchen exhaust through an ERV? Seems a huge waste to dump your entire heat load of the house to use electric heat as a replacement.

    • @HomePerformance
      @HomePerformance  5 років тому +4

      Because cooking creates lots of particles and chemicals you don’t want floating into your space. The grease particles would clog an ERV core. This is the best approach for controlling HOMEChem. Saving energy should always take a backseat to human health.

  • @greg925911
    @greg925911 5 років тому

    shouldn't the dryer vent be as short as possible an cant u connect the range hood to the ERV with the bathroom fans to with a boost when needed

    • @HomePerformance
      @HomePerformance  5 років тому +2

      The dryer vent length depends on where the dryer is placed and where the termination will be. And no, you can’t run the range hood into the ERV- grease will clog it, and the total flow is only 150-200 cfm.

  • @BradleyFordAus
    @BradleyFordAus 2 роки тому

    Also why would you not pull the makeup air through the ERV?

    • @HomePerformance
      @HomePerformance  2 роки тому +1

      Not possible- an ERV for this size house moves 150 CFM, and we're talking about adding 600 CFM to that.

  • @ajbrown2013
    @ajbrown2013 2 роки тому

    Just make a 3 phase motor and hook it up to a thermocouple and humidifier controller

  • @lenbloom338
    @lenbloom338 Рік тому

    Panasonic is one of them. I will share the language in their literature later today.

  • @lgrizzly
    @lgrizzly 5 років тому

    I mean this sounds great to be so concerned about the air quality but I can’t help but worry about the huge energy demand this adds to the home. The power has to come from somewhere. One house...that’s ok but can you imagine a whole block? A city? I understand these are probably efficient motors and such but regardless this is an enormous addition of energy waste. There must be a more passive way to accomplish this.

    • @HomePerformance
      @HomePerformance  5 років тому +1

      There is not a passive way. But the house is so efficient otherwise that it leaves 90% of other homes in the dust. For example, 45,000 cu ft of enclosed air across 3,015 sq ft heated and cooled with less than 30kBtu. Furnaces traditionally start at 40k.

    • @pyramydseven
      @pyramydseven 4 роки тому +2

      It is a work of art.

    • @23lkjdfjsdlfj
      @23lkjdfjsdlfj Рік тому +1

      The math shows that equipment like this is an enormous energy win. Passively exchanging CO2 by opening windows just burns money - it's the most wasteful solution by far. What you want is an active fan with a heat exchanger - this is enormously cheaper.

  • @imwteach
    @imwteach 3 роки тому

    Pretty disappointing, if the blower door test is better than passive spec why have an exterior dryer and kitchen stove vent? Current dryer technology would dictate a heat pump dryer that condenses moisture and dumps to drain! My home is 12 years old and the air to air exchanger exhausts from bathrooms and kitchen and returns to living room. Stove hood is internal and filters smoke and smell and exchanger exhaust takes care of humidity.

    • @HomePerformance
      @HomePerformance  3 роки тому +1

      We ultimately did go with a heat pump dryer, but the science is pretty solid on exterior vented kitchen exhaust being critical. Too many small particles that the basic carbon and grease filter just can’t capture.

  • @ek9772
    @ek9772 5 років тому

    Get a heat pump dryer and avoid the dryer exhaust.

  • @tweake7175
    @tweake7175 5 років тому

    Can you expand on the comment that plastic erv or hrv transfer faster in mild conditions but aluminum is better in cold conditions.

    • @timothywelch4721
      @timothywelch4721 5 років тому +1

      Heat difference would be higher and metal is better at heat transfer

    • @tweake7175
      @tweake7175 5 років тому

      @@timothywelch4721 aluminum is obviously better in heat transfer but why would plastic be "faster" in mild conditions?

    • @HomePerformance
      @HomePerformance  4 роки тому

      I remember understanding his comment at one point, but can't figure it out now

    • @mysunnyjim
      @mysunnyjim 3 роки тому +3

      @@tweake7175 Hey Tweake, Phil from the video here(I'm no longer at Fantech but am still involved in the industry), hadn't seen these questions before but essentially my engineers at Fantech explained the following about the heat transfer: Plastic being thinner and more capable of conducting the heat faster through the membrane performs better at most temperatures. Aluminum takes longer to transfer the heat through but remains more efficient at very low temps. Plastic has a point of diminishing returns and cannot outpace the aluminum for performance at extreme temps. That's not to say the plastic cores aren't good, they are. Aluminum is just more stable in extreme cold. Hope that made sense.

  • @mtscott
    @mtscott 2 роки тому

    Good video but I’m in two minds about this. Simplicity v moving with the times. The drawbacks as I see them:
    1. Remember when we opened the window? We are moving a long way from simplicity and lots of motors and electronics to go wrong = cost.
    2. Filters = forever operating costs as they have to be replaced.
    3. Filters = obsolescence. They’ll stop making them in two years!

    • @HomePerformance
      @HomePerformance  2 роки тому

      Ok, but… Remember when taxes didn’t exist? Remember when there was no traffic? No pollution? No jobs? Just little family clans, hunting and gathering and living their best life? No cell phones in sight.
      We can’t go back.

    • @mtscott
      @mtscott 2 роки тому

      @@HomePerformance I get your point. Don’t get me wrong. I was just questioning if the road would ultimately prove to be the right one.
      As an example of thinking we were on the right road: remember when we used leaches, we took arsenic for health, we inhaled mercury for invigoration. Sometimes the path looks right but is ultimately wrong.
      In my new build I am planning to install: balanced passive air with hrv , hvac, range hood and makeup air, solar, battery 😁👍🏻

    • @HomePerformance
      @HomePerformance  2 роки тому

      I hear you. I’m frankly more worried about us going too far in this direction… the complexity in this vid is nothing compared to IoT connected ‘smartness’ and where we could be headed. Maybe we never take masks off again? :(

  • @rocky7gd
    @rocky7gd 3 роки тому

    that lint trap is a bad design. When you take it out, all the lint falls to the floor. I have that in my rental condo

  • @pdpode8978
    @pdpode8978 5 років тому

    What captures mycotoxins, mold is bigger than mycotoxins.

    • @HomePerformance
      @HomePerformance  5 років тому +1

      HEPA filter

    • @pdpode8978
      @pdpode8978 5 років тому

      Home Performance I have an Air Dr purifier which has a carbon and hepa in it right now becuz I’m in a moldy house, the purifier is in the room I spend most of my time in, its all I know to do til I can get out of here.

    • @HomePerformance
      @HomePerformance  5 років тому

      So sorry to hear! Save yourself!

    • @pdpode8978
      @pdpode8978 5 років тому

      Home Performance been trying for 18 months can’t find a safe house so sick

    • @HomePerformance
      @HomePerformance  5 років тому

      Look into Hayward Score if you haven’t already

  • @paulomontero12
    @paulomontero12 Рік тому

    Guy should be in a float somewhere?

  • @irishvoyageur
    @irishvoyageur 3 роки тому

    Seems like a lot of things could go wrong. What ever happened to keep it simple? Will you need your HVAC expert on speed dial?

    • @HomePerformance
      @HomePerformance  3 роки тому

      Since when did we ‘keep it simple’ in modern civilization? Those days are long gone.

  • @DavGreg
    @DavGreg 5 років тому

    Maybe I missed it, but what is the cumulative power consumption of a setup like this, averaged out, compared to what is commonly used. Otherwise, how big a hit on the electric bill.

    • @HomePerformance
      @HomePerformance  5 років тому

      These are among the most efficient units made today. As explained in the vid, you can’t do without any of these in a very airtight home, so the exact consumption is beside the point.

    • @gloriaalkins3589
      @gloriaalkins3589 3 роки тому

      @@HomePerformance Here in Australia, we have the solar advantage. A 6kW system installed that the power company only allows you to produce/draw 5kW from!

  • @ryanbarr4910
    @ryanbarr4910 2 роки тому

    When the electricity goes out or the machine breaks you have mold & poor indoor air quality.

    • @HomePerformance
      @HomePerformance  2 роки тому

      That will happen to your house too if it goes without your AC running. If there’s no gas, society breaks down. No medicine, same. We live in a society.

  • @brianhunley5302
    @brianhunley5302 2 роки тому

    Good information but I can't handle the word sexy used so much about ventilation.....

    • @HomePerformance
      @HomePerformance  2 роки тому

      If you can’t take the heat get out of the kitchen Brian

  • @kurtrussell1327
    @kurtrussell1327 5 років тому +1

    16 cups of water in 1 gallon, not 8.

  • @david7384
    @david7384 3 роки тому

    I think I went broke just watching this video

    • @HomePerformance
      @HomePerformance  3 роки тому

      I think not, David- the bill for all of this at full retail price is around $7000

  • @ajbrown2013
    @ajbrown2013 2 роки тому

    Dudes I smoke I paint I breath in crap all day I’d rather have good water than air anyday

  • @dlg5485
    @dlg5485 3 роки тому +3

    Why bother bringing an expert on if you're never going to let him talk? So annoying.

    • @HomePerformance
      @HomePerformance  3 роки тому

      I am so, so sorry. Truly. So sorry. Dear god. How could I? Sorry.

    • @mysunnyjim
      @mysunnyjim 3 роки тому +3

      This is a funny comment because normally I'm the guy who doesn't shut up. Phil here DLG, and the whole point is that this was Corbett's build and I was there to add the explanation of product specs and a bit of depth, etc but not host the show. This is Corbett's home and his channel, I was just happy to be a sidecar for this one. :-)

    • @gloriaalkins3589
      @gloriaalkins3589 3 роки тому

      @@HomePerformance You're just passionate about ventilation! I get it!

  • @charlespaine987
    @charlespaine987 11 місяців тому

    Start talking $ for installation , $ power requirements , $ maintenance ps . Active UVC IN PROPER FREQUENCY BAND will disinfect air and surfaces without creating ozone .Maintenance (professional vs home owner) break it down. You MUST TAKE into consideration most people will not do or contract needed maintenance even fewer will pass needed knowledge to subsequent owners. Failure points