Siemens S7-1200 PLC, SB 1231 RTD temperature module wiring, TIA portal V16 monitoring. English

Поділитися
Вставка
  • Опубліковано 4 лют 2025

КОМЕНТАРІ • 18

  • @tarekgamalamin6824
    @tarekgamalamin6824 2 роки тому +1

    I really wanna thank you for your great great great work, your channel is a treasure

    • @IGSElectronics
      @IGSElectronics  2 роки тому

      Glad you enjoy it! Thank you for your support.

  • @shion3145
    @shion3145 12 днів тому

    thnaks bro! you help me a lot.

  • @wolk2
    @wolk2 3 місяці тому

    you are my new hero thanks mate

  • @kevin00861
    @kevin00861 Рік тому

    Thank you Sir for your amazing videos,
    I kindly need your consultation;
    Siemens Analog RTD input module - SM 1231, all channels report / return -32768, even though configured to 3 wire pt100,
    any advice, please

  • @juwelbdonline
    @juwelbdonline 2 роки тому

    fantastic sir

  • @saleemahamed6352
    @saleemahamed6352 9 місяців тому

    S7-1200 PLC has 6 HSCs. If i need 4 more HSCs for Single phase counter operations. which Signal board or Signal Module shoulde choose?

  • @ovidiulazea8938
    @ovidiulazea8938 Рік тому

    Excellent!

  • @sevvalerol2595
    @sevvalerol2595 2 роки тому

    Thank you for your effort sir! I have a question. I am building a project with the sb 1231 rtd module, after wiring the module what did you use as thermocouple? I mean what type of sensor can I use to detect the temperature of the room? Thank you.

  • @coskuntuncer1114
    @coskuntuncer1114 3 роки тому

    Thank you for your effort Ingus! I appreciate it. No need to norm and scale the value that we measure then? Cheers!

    • @IGSElectronics
      @IGSElectronics  3 роки тому +1

      Hi Cockun. It wary much depends of what you are using the reading for. For basic set up just to read the temperature on HMI, no not really. But if you want more then just reading, again wary much depend of application, you might need it. This reading quite often is used with PID set ups.

  • @spartanthreads6606
    @spartanthreads6606 3 роки тому

    Great videos thanks for sharing. Can you show how to connect a profinet device and how to setup telegram. Cheers

    • @IGSElectronics
      @IGSElectronics  3 роки тому

      Hi Spartan, i will put that on the list to do.

  • @juliocesardealmeida2167
    @juliocesardealmeida2167 3 роки тому

    Dear Sir, I would like very much that, if possible, you could make a short video on how to use the 6ES7 241-1CH30-1XB0 (RS 485). Thank you very much!

    • @IGSElectronics
      @IGSElectronics  3 роки тому +1

      Hello Julio, yes the video is coming soon, just waiting on bus terminators to come in.

    • @juliocesardealmeida2167
      @juliocesardealmeida2167 3 роки тому

      @@IGSElectronics INGUS, thank you so much! You have no idea that will help me about my knowledge! Sorry but my English is not very well!

  • @jaimenavia2929
    @jaimenavia2929 3 роки тому

    Hola puedes ayudarme con la conexión de una signal board SB 1222 200 khz DQ 4x 5VDC 0.1A.
    No la reconoce mi plc s7-12000 dc/dc/rly version .1

    • @IGSElectronics
      @IGSElectronics  3 роки тому

      La pregunta es, ¿ha insertado la unidad en su controlador mientras estaba encendido? Si es así, el controlador ya no podrá aceptar más tarjetas SB en esa ranura. Esa parte del PLC se dañará y ya no podrá utilizarse.