HOT WATER TAKES A LONG TIME TO REACH TAPS - HOW TO GET HOT WATER FASTER! Wilo Secondary Return Pump

Поділитися
Вставка
  • Опубліковано 28 лис 2024

КОМЕНТАРІ • 340

  • @plumberparts
    @plumberparts  4 роки тому +3

    Emily Loves me even more now! ALL SONGS SELECTED BY THE #ALEARMY MASSIVE!
    🍺 *JOIN THE ALE ARMY* *_Exclusive weekly live videos on Thursday_* : www.patreon.com/plumberparts
    🛠 *AMAZON TOOL STORE BUY THESE TOOLS HERE* www.amazon.co.uk/shop/plumberparts
    📺 *VLOG CHANNEL:* ua-cam.com/users/timeswithjames

    • @MikeMcDaniels-w1u
      @MikeMcDaniels-w1u 10 місяців тому

      Great Job! There must be 20 'end of line, thermal check valve' system explanations on the internet. Your explanation is the only REAL 3 line system. These silly two line systems make the cold water warm! So you end up running the cold line, to get the warm water out! hahaha. 😂

  • @marklawrence8517
    @marklawrence8517 3 роки тому +2

    Wish every plumber took as much care as this chap. Especially the pipe directions on the floor boards. Don't you just hate the way he is able to "guesstimate" the bend radius and it's perfect. first time every time (show off!!). Fab video thanks very much really benefitted from watching it.

  • @pumpkinhead456
    @pumpkinhead456 2 роки тому +3

    I installed the exact same pump to as close to the final tap as I could. Hot water time down from 40 seconds to 6 seconds. It's an expensive little fella to buy, but at 5 Watts soooo cheap to run and works a treat!

  • @raycollington4310
    @raycollington4310 4 роки тому +5

    This channel is very informative to us amateur plumbers and from the ones I’ve met, a lot of professionals too. I held tight!

  • @yt66228
    @yt66228 4 роки тому

    Put this in my house 30 years ago. I installed a small diameter pipe as a return manifoid so all taps in house can be reached. Love it!

  • @anthonysykes542
    @anthonysykes542 3 роки тому +1

    Watched a lot of your videos, very informative! Certainly the best Plumb-Tube here. I was watching in the hope to learn how to increase hot water pressure on a gravity fed system, takes about 2 minutes for 1 litre of water from our kitchen tap! It got worse ever since I replaced the deck mixer tap which claims to work on a 0.2-5.0bar system. Stressful times trying to find a black and stainless steel/chrome mixer tap which will work with such low pressure. Keep up the good work and quality videos

  • @radfoo
    @radfoo 4 роки тому +2

    Brilliant, remember you mentioning this as an upcoming video a few months ago and was looking forward to seeing how it all worked. Thank you.

  • @ebebop
    @ebebop 3 роки тому +2

    I had my pump connected to movement sensors at each tap so it only came on when it was needed. Worked perfect. I will be installing it in my new house. Mine was more like 1 second the beauty of plumbing the house from scratch.

    • @tlangdon12
      @tlangdon12 3 роки тому +2

      Movement sensors near the taps is a great way to avoid running the pump when there is no chance of hot water being drawn off. .

    • @sr.gateau
      @sr.gateau 11 місяців тому +1

      I'm setting up a smart motion activated light switch to automatically turn on a smart plug the pump is connected to. Any number of smart motion activated light switches in various locations can activate the pump for a set time - in my case one minute should do it.

  • @robconnolly6614
    @robconnolly6614 4 роки тому +9

    Just another thought, as the flow rate is so low to cater for the heat loss, you could use 10 mm pipe for the return. Can save on joints as well as a bit of cash. I’ve got a 20 m run on one return with a 2 m dead leg and the shower is hot in 3 to 4 seconds. Nice video 👍

    • @plumberparts
      @plumberparts  4 роки тому +4

      Rob Connolly mate that is a top idea! Wish I’d thought of that!!!

    • @stevecraft00
      @stevecraft00 4 роки тому +2

      I came here to ask this! 10mm seems perfect for the return as long as the pump is ok with this.

    • @robconnolly6614
      @robconnolly6614 4 роки тому +2

      10 mm is fine, the heat loss on a well insulated 10mm
      Pipe is low compared to the load on a 15mm feed to a rad, so the volume flow rate is small.

    • @rickbaguley7997
      @rickbaguley7997 3 роки тому +2

      I think it is normal practice to run the return in a pipe size lower

  • @muddyfunker3014
    @muddyfunker3014 4 роки тому +2

    Mate you are actually a legend.
    I'm currently redoing an upstairs bathroom at mine and have this exact problem.
    Haven't watched video yet but no doubt you'll have a solution.
    Thanks for sharing your knowledge 👍🏻

  • @robertharvey9698
    @robertharvey9698 3 роки тому +1

    We have a return pump as we have a massive distance to the kitchen sink. When we moved in there was a very simple timer & almost no insulation on the pipe runs. It would be impossible to add the insulation so I’ve made the pump Alexa voice controlled. Just ask it to turn on the hot water pump & it runs for 5 mins & shuts off. You just need to ask it to turn on just before you want hot water in the kitchen & it works fine. It was taking a whole bowl of wasted water before, now it’s only a litre or so. No need to turn it off as the pump only runs for a short time. Nice quick fix 👍.

    • @danquestnorth768
      @danquestnorth768 2 роки тому

      Exactly what I'm about to do with our vacation cottage.

  • @RonaldDCass
    @RonaldDCass 4 роки тому +3

    Eight or ten years ago, I installed a "point of use" 2 gallon electric water heater in our kitchen (12 or more feet from main water heater) for "instant" hot water. Hot water from main heater enters through the "point of use" unit so no loss of hot water, only the amount that cools off in the supply line from main to auxiliary unit. I have moved & installed same in new house.

    • @paulowen-iy6vm
      @paulowen-iy6vm 11 місяців тому +1

      I did a simular thing, But for different reasons. a small 10 litre cylinder is a good simple solotion.
      We live in the country, no gas, only oil and at the time only electic showers, so using oil to heat a tank of hot water to wash hands. (we have a log burner with boiler for winter hot water) so put 10 litre hot water cylinder and fed the taps with a 2nd feed, using isolation valves to switch the feeds summer to winter.
      It worked brilliantly and saved best part of a tank of oil a year. Now we have solar thermal and solar PV, which works great espcially in the summer, (and we even get paid £1k a year through the RHI and FIT too)
      But I need to solve the problem of a long time to run hot water through to the far taps, (House is 65 ft long) hence coming here to learn more, and will fit a return loop during the kitchin refurb. This video is imfomative

  • @davidoshea1536
    @davidoshea1536 4 роки тому +2

    Great video bud.👍 Very informative, looking forward to seeing the next one.🌟

  • @cubanlinx
    @cubanlinx 4 роки тому +4

    I gotta insulate my pipes - been singing this all day... thanks! 🔥

  • @lukemitchell6146
    @lukemitchell6146 7 місяців тому +1

    Hello sir, thanks for your knowledge! Thought there was one point I was hoping to find the answer to.
    Do you know if you can tee off the hot return so you can circulate hot water in 2 or more areas?
    Or will the water short circuit and only loop around the nearest point if done like that?
    Is the only option to run/ loop the return at the last point?
    Thanks and HOLD TIGHT! 🫡

  • @richardpennclark1739
    @richardpennclark1739 4 роки тому +2

    Hi . Just enjoyed your video. I'm thinking of using this on our bathroom refurb. Please remind me. Why can't you do the pipework in plastic? Surly plastic pipe is as resistant to things as copper. Would it make a difference if the water was softened? Thanks Richard

  • @webmastermail8
    @webmastermail8 3 роки тому +6

    I thought the common excepted hot/cold setup was hot always on the left how comes a plumbers house has the hot on the right ?

  • @UberAlphaSirus
    @UberAlphaSirus 4 роки тому +4

    19:30 Dat insulate my pipe song doe! Gonna play that in the van. Glad to see your bathroom is coming on fast, just like mine.

  • @Holler_Rat
    @Holler_Rat 4 роки тому

    Love converting your celsius temps to fahrenheit. So much fun!

  • @Jeffopar
    @Jeffopar 3 роки тому

    My system is the exact opposite. My cold water is hot and I have to wait for cold water. BTW, your flying videos are so much better.

  • @bikerchrisukk
    @bikerchrisukk 4 роки тому

    Great bit of kit, is this the first of it's kind, cos I remember something similar from a fair while ago. Always recommend it to clients as something to consider when other stuff is getting ripped out / put in anyway. Seen some cheaper ideas for a thermo valve that redirects the cold water out to a water butt, then flows inside when hot enough. Still means delay but at least no wasted water and veg /plants get fed, also a lot less work needed. All the best and Hold....
    ....Tight 👍

  • @ddoubledutch4783
    @ddoubledutch4783 2 роки тому +1

    Great teacher. I install and love learning. Class

  • @johnburns4017
    @johnburns4017 4 роки тому +3

    This is the first I have heard anyone say you cannot use plastic pipe on a secondary circulation loop. You *can* use plastic pipe, best to try and make it plastic barrier pipe. Best to have the return pipe to the cylinder a small bore, as the water only needs to move slowly.

  • @barnaby5896
    @barnaby5896 4 роки тому +9

    Who remembers when James started doing that little bathroom a long time ago 😂

  • @markgilder9990
    @markgilder9990 4 роки тому +4

    Great video. Think I’ll install an instantaneous water heater under the kitchen sink. Boom, drop the mic.😂😂😎

    • @razer192
      @razer192 4 роки тому +1

      Would be a lot better than all that messing about and still having 3/4 of a bowel of waist water think this was a total waist of time and money tbh

    • @floatybisquit
      @floatybisquit 4 роки тому +1

      I agree about time people ditched hot water tanks and immersions!!

  • @johnburns4017
    @johnburns4017 4 роки тому +8

    The dead-leg can be overcome by fitting instant electric taps, like a Qooker boiling water tap fed from the hot water draw-off from the cylinder (there are a number of makers). It would need to be a mains pressure system, like a: combi, DHW only thermal store or unvented cylinder. Qookers are a design feature in a kitchen these days with many prepared to pay for looks alone. Qookers also eliminate an electric kettle giving more room on the worktop surface, eliminating trailing electric leads. That means small children cannot reach up then grab electric kettle leads, pulling boiler water over themselves.
    A secondary circulation loop drags lots of heat from the cylinder over a day which will be wasted, and costs money in bills, no matter how much insulation you put on the pipes.
    I installed a secondary hot water circulation pump in a large house, with two bathrooms remote from the cylinder. I fitted a movement sensor in each bathroom, that only brought in the pump when people were in the bathrooms. It pumped out the hot water fast enough. Using the sensors means the pump only operates when needed, not on a timer. So even during the night, instant hot water at the taps, with no timer holding the pump out.

    • @5084204
      @5084204 3 роки тому

      Very clever idea with movement sensors. Well done! Did you use any particular system, or was it complete DIY?

    • @johnburns4017
      @johnburns4017 3 роки тому

      @@5084204
      All easily available parts.

  • @gav44
    @gav44 4 роки тому +15

    Is there a way of improving hot water delivery from a combi boiler with no tank?

    • @geoffcarlton4047
      @geoffcarlton4047 4 роки тому +4

      Yep, move the boiler closer to the sink, or the sink closer to the boiler.

    • @tomhill54
      @tomhill54 4 роки тому +3

      Some combis have a preheat function that might help a little..

    • @Richard-ij8ge
      @Richard-ij8ge 4 роки тому +1

      Look up combisave

    • @neiltitmus9744
      @neiltitmus9744 4 роки тому

      Smaller pipework be handy if a boiler could preheat the pipework through

    • @lovingitlots
      @lovingitlots 4 роки тому

      Is it possible to go a shorter more direct route with the feed maybe

  • @bsl849
    @bsl849 2 роки тому

    Great video, very comprehensive. Q: should it be done in 22m copper pipe to serve 6 bathrooms & utility & kitchen?

  • @tyowen5674
    @tyowen5674 Рік тому +1

    Do any of these pumps come with sensors that switch on the pump if the water in the pipes fall below a certain temperature?

  • @davidkargbo3132
    @davidkargbo3132 2 роки тому

    Job well done and appreciated your efforts keep it up.
    Why is my HOT WATER so hot when I switch the mixer to the hand shower? THE HOT WATER can't mix at all.
    Should it be the MIXER that has the problem?
    Thanks so much you are very wonderful.

  • @carguillo1
    @carguillo1 4 роки тому +1

    Hi Jame ( best plumber on youtube ) just put a non-return valve on my kitchen tap and now it takes about 3min to come through do you know what it could be thanks mate /kev in EPSOM

  • @kat_i_mac
    @kat_i_mac Рік тому

    40 seconds? Mine takes 5 minutes!!! Plumber said that's just something I'm just going to have to get used to... thanks for this video

  • @robconnolly6614
    @robconnolly6614 4 роки тому +3

    You can also electrically trace heat the flow pipe, before insulating. I think it works out around £100 for a 10 metre run including pipe contact thermostat. Works for combi’s

    • @otw5974
      @otw5974 2 роки тому

      Not heard this one, but I understand the principal. However, with an unvented combi how will DHW expansion be accommodated, as I presume the trace will pre-heat the static water?

    • @robconnolly6614
      @robconnolly6614 2 роки тому

      @@otw5974 You can fit a small expansion vessel on the DHW to pick up any expansion. They are around £20

  • @gimpalopagus
    @gimpalopagus 3 роки тому +21

    Mate, I just bulk boil my water and then freeze it for later, boiling water whenever I need it just sitting there.

    • @rogermannerings7092
      @rogermannerings7092 3 роки тому +6

      Bulk boiled water is just silly. Use packets of dehydrated water. It’s a lot easier to store and carry about.

    • @becton98
      @becton98 3 роки тому +3

      Pair of fools, dehydrate your water and then pop it in a ziplock bag in the freezer, this saves space and keeps the boiling water fresh

    • @rogermannerings7092
      @rogermannerings7092 3 роки тому +2

      You have not allowed for the colesaireal reaction which occurs when dehydrated water approaches the incorrect temperature. I have destroyed at least two freezers misusing this method, there may hve been more but I wasn't in the house at the time so I cant be blamed.@@becton98

    • @becton98
      @becton98 3 роки тому +2

      @@rogermannerings7092 you're only right as well!, I was wondering why my freezer was a steady 55 Celsius

  • @martynbuzzing3327
    @martynbuzzing3327 2 роки тому

    Thanks for that. I’m not understanding if the shower gets hot water faster as well as the faraway kitchen tap.

  • @claudioscola
    @claudioscola 3 місяці тому

    OMFG I did not know this existed. It's genius! Thanks so much!

  • @halfassed911
    @halfassed911 4 роки тому +8

    When I heard the "insulate my pipe" song I had to like and subscribe.

    • @plumberparts
      @plumberparts  4 роки тому

      Cheers dude! There's loads of songs strewn around my videos!

  • @speedboatbuilder
    @speedboatbuilder 4 роки тому +1

    Great video!... just one question... can you install a secondary pump like this and also a twin impeller shower pump on the same circuit? (i.e. to solve the problems of both low pressure and having to run hot taps for ages with a gravity fed open vented cylinder)

  • @carnutal3627
    @carnutal3627 4 роки тому +1

    Lovely video BUT was all that work worth it? It saved about what 10 seconds time?

  • @dabay200
    @dabay200 2 роки тому +1

    For the return pipe can you use a smaller diameter pipe (e.g. 10mm or 8mm) to save on copper and water, since the flow rate through the pump is tiny? Also can you hook up multiple return pipes to the same pump or is it only 1 return pipe per pump?

  • @richardaird2880
    @richardaird2880 Рік тому

    Hi, just watched your vid on secondary return hot water. Did you just tee into the the existing hot water draw off from the cylinder? Only the vid doesn’t show you making the final connection into the hot water draw off. Regards

  • @maddogcustoms9207
    @maddogcustoms9207 Місяць тому

    Morning, may i ask why you decided to go for a hot water boiler system over a combi boiler in your house? Would love to know your reasoning. We are going to go refurb a bungalow into a double story and all batherooms and kitche will be located within 25/35m from the water heating system, give or take that is. Love all your videos btw, thanks

  • @mx986
    @mx986 4 роки тому +2

    Interesting vid thanks :) Not sure why you can't use plastic though ? (as in 'real life' issues rather than regs).

    • @jpfrench1496
      @jpfrench1496 4 роки тому +3

      I thought exactly the same. Can’t see why you can’t use plastic? When it’s fine on any other hot water supply.

    • @martinspencer9950
      @martinspencer9950 4 роки тому

      Pipe Manufacturers instructions say so !

  • @barriedear5990
    @barriedear5990 3 роки тому +1

    We had a secondary return fitted in our house around 17 years ago, IN PLASTIC. Is this an issue. Have also seen on other you-tube, that plastic is OK, as long as you have on a timer to switch off daily. Secondary return services 4 bedrooms, 3 bathrooms, kitchen and utility, really wouldn't want to swap out for copper at this stage. Works a treat though.

  • @gf5328
    @gf5328 2 роки тому

    Great video. Very informative. 👏. Is the reason that you can not use this as a shower pump simply because it’s weak compare to a shower pump incase you open more than 1 tap and need much more force to push the water than a bronze pump?

    • @gf5328
      @gf5328 2 роки тому +1

      And I’ve only ever seen them on return near to cylinder. But a comment and your other video showed them on flow even tho you have it on the rerun in this video. Not that I’ll ever put it on the flow but can it be installed on flow?

  • @rmower3428
    @rmower3428 Місяць тому

    Quality work master James

  • @otw5974
    @otw5974 2 роки тому

    As I have a combi boiler, and therefore cannot use a DHW sec return, I've had an idea of installing an inline instantaneous water heater on the hot feed to our farthest (problem) outlet. The idea being that the heater would provide instant 'hot' (~36oC) water and then, if ran for long enough, the primary hot water would come through at ~50oC, causing the stat to turn the heater off. Apparently the max inlet temperatures can be up to ~60oC on these instantaneous heaters. Would be interesting to compare cost of materials and labour and then running costs of each solution.

  • @williamstewart208
    @williamstewart208 Рік тому

    Hi James, I wonder if you might advise me as to whether it is easy enough to change my white key filling point for the newer blue no key filler on my Worcester Bosch boiler….and if so how or where I would get the parts. many thanks in advance..Willie.

  • @ron4569
    @ron4569 Рік тому

    I live in Spain and have a 100L electric water heater which is located in the garage, the kitchen tap is about 35m from this. I have the same problem with the time it takes for the hot water to arrive. In spain is the existing copper pipes are buried into the wall, so there is no way to insulate them, fitting new pipe is possible though in the underbuild but as an alternative, what do you think about me fitting a smaller 15L under sink electric water heater in series with hot water line from the existing tank to act as a heat buffer? Something like an Ariston Andris R10? This would also mean when I dont need the 100L tank I could just use the smaller tank?

  • @chrispointer2474
    @chrispointer2474 9 місяців тому

    Can you 2 secondary runs off one tank? I have a run I can do in the 1st floor of the house but I also have a second floor with two en suites. Should I just run one loop and get the loop as close to all the taps and showers on both floors or can I run two loops with two pumps so I can turn the upper loop off when there are no guests and just family in the house who only occupy the 1st two floors and not the top floor?

  • @heatpump8566
    @heatpump8566 4 роки тому

    I’ve got 6 dhw outlets and chipboard flooring. I’ve decided instead of what you’ve done, I’ll fit a bronze pump on the cold feed into the cylinder. Will achieve a similar result with no added pipework . I’ll probably use the wilo pump

    • @spencerwilton5831
      @spencerwilton5831 4 роки тому +2

      Paul Turner You don't want to be returning hot water from the top of your tank to the bottom- it sounds like that's what you're planning? The whole point of a cylinder is that they stay hot at the top, and cool water is added at the bottom. You'll end up mixing the tank and just have lukewarm water until the whole tank has recovered. It will also destroy the efficiency of your boiler which relies on the lower return temperatures from the bottom of the tank to run in condensing mode. You will notice you get more vapour from the boiler flu after a shower or bath is run and the boiler is getting properly cold water returned to it. As the tank heats, the vapour reduces. Your design would mean you were constantly trying to heat already warm water.

    • @heatpump8566
      @heatpump8566 4 роки тому

      Spencer Wilton hi mate no I have only done that with a stratification pump on horizontal cylinders. You use my method when you don’t have a secondary return tap in. It works really well

  • @pumpkinhead456
    @pumpkinhead456 2 роки тому

    Long shot that you'll read this in time, but what are the Union fittings going in to this pump? Did you just use 1 inch to an end feed fitting? Done the pipework all the way to this particular pump now!

  • @shifty277
    @shifty277 3 роки тому

    Loving the new track! Please do a studio BTS session of you going absolutely bananas with a pint of ale whacking out such rhythmic hip hop bangers!
    Hold tite!

  • @crazyb4spoons
    @crazyb4spoons 4 роки тому +8

    Should definitely release an album of the banging tracks on iTunes 😂

  • @VivDiwakar
    @VivDiwakar 2 роки тому

    Mate, you're a funny bugger!! Love the singing!!

  • @001cvr
    @001cvr 3 роки тому

    My combi has the same oroblem ,can you do a video of same for improvements of hot water flow and pressure

  • @wilbauk
    @wilbauk 2 роки тому

    Would you consider a bypass valve to dial in the required flow around the circuit and reduce unnecessary load on the pump?

  • @Alan.Moffat
    @Alan.Moffat 4 роки тому +24

    Typical tradesmans house..... Unfinished 😂😂

  • @jamesrowe5047
    @jamesrowe5047 4 роки тому

    Hi James. This might be a really stupid question and I apologise in advance. When installing the pump would I need a sparky to do the electrics?

  • @doncodman913
    @doncodman913 4 роки тому

    Hi great vid ... what is all that foil under the boards please ?? regards Don

  • @andreswanepoel4826
    @andreswanepoel4826 4 роки тому

    Great tip. Where did you tie in the return line from the wilo pump? On the boiler's pressure safety valve?

    • @sr.gateau
      @sr.gateau 11 місяців тому

      It ties back into the line feeding the heater.

  • @boggy7665
    @boggy7665 4 роки тому

    I replaced a long run of large-bore galvanized pipe with 1/4" PEX. Much less water in the pipe, flows a much faster face velocity when the tap is opened. Works for me because the water pressure in our city is high - around 80 psi, maybe - and the draw rate at the kitchen sink faucet, with its aerator, is relatively low. Flow rate seems the same, but the hot water comes much, much faster. You can do calculations to see if it'll work for you. It's been too long since I've gone to school, so don't ask me to do those calculations for you, sorry!

  • @robmarrin6720
    @robmarrin6720 4 роки тому

    The house you are in I'd say from the plumbing work I've done in similar homes in Whirlow and bakewell UK is around 850k conservatively 👍

  • @clivesanderson
    @clivesanderson 3 роки тому

    do u have a video on pressure testing thanks

  • @policematrixx
    @policematrixx 2 роки тому +1

    I wouldn't like to comment on their product from 10 years ago, but the issue with their current product not being suitable for hot water return is due to the standard that they manufacture to changing to stop those products being used for a secondary return.
    That change was down to a failure of someone's product, made to that standard, some years ago that caused a huge incident, that then caused BS to withdraw the allowance of products manufactured to their standard to be used for secondary returns. The cause of that incident was eventually found to be installer related and not a product issue, but British Standards are still not happy to change back to allowing products manufactured to their standards to be used for secondary return hot water pipe work.
    In short, even if it were down to oxygen in the system, it would still affect metal systems much more than any plastic system.
    As I commented before, we have installed thousands of return systems in projects from single family homes, to hotels, 1,200 apartment multi residential developments, commercial and industrial.
    Our products are not only tested and approved for use on return systems in Europe, but also most developed countries around the world, including America.
    The issue is with the BS standard in the UK that the UK companies test their manufacturing, materials and designs to.

  • @FlyingFun.
    @FlyingFun. 3 роки тому +5

    Shame I have a combi boiler in my house now, takes ages for hot water to come through.

    • @WhiskeyGulf71
      @WhiskeyGulf71 3 роки тому +1

      I have over come this problem as i too have a combi & even though i live in a small flat the water takes ages to come through hot especially as i have the worse make for this problem, Ideal.
      My ideal boiler has a switch on it to keep the water hot, it does nothing ! So i have installed an inline water heater, it holds about 10 litres i think, it lives under my kitchen sink in the cupboard & the hot water from the boiler passes through this small emersion heater, thus when i turn on the hot tap i have very hot water in a few seconds.
      The temperature is adjustable up to 70°C.
      Because it is fed from the boiler the water never runs cold. It’s 3kw but it doesn’t use much electricity, most likely more efficient than a pump circulating hot water.

    • @FlyingFun.
      @FlyingFun. 3 роки тому

      @@WhiskeyGulf71 thanks, i wondered if something like this was possible.
      Will look into it.

    • @WhiskeyGulf71
      @WhiskeyGulf71 3 роки тому +1

      @@FlyingFun. i bought it second hand on ebay for £20, it’s an ariston unvented, 10 litre capacity, 3kw under-sink water heater.

  • @EmsillCazm
    @EmsillCazm 3 роки тому +1

    I am just in the middle of doing my kitchen extension, front porch with cloakroom, utility room and an ensuite, I have fed a separate hot water feed from the hot water cylinder to each of the taps that run in opposite directions to each other this gets over the problem of the hot water having to run around the house to feed........ lets say, The kitchen, utility room & then the cloakroom,

  • @techtonicsystems
    @techtonicsystems 4 роки тому

    Another excellent video. Love the singing! Is there an equivalent system for a combi boiler set up?

  • @boomdox5843
    @boomdox5843 3 роки тому

    That bloody song 😂🤣 brilliant

  • @davidlee-taylor3792
    @davidlee-taylor3792 3 роки тому

    Hi m8, best way of doing what you’ve done to a gravity fed system. I’d love hot water quicker to my kitchen sink please 👍

  • @MARTINA-gc3tq
    @MARTINA-gc3tq 4 роки тому +2

    If using this or any similar system use PEX not copper or ensure the copper pipes are not close to incoming cold water supply.

  • @richardowen2159
    @richardowen2159 2 роки тому

    Can you use this with a combi?

  • @dombaker6210
    @dombaker6210 3 роки тому

    Love the uphill toilet soil pipe at 5:20.

  • @jamesgalloway8835
    @jamesgalloway8835 3 роки тому

    Great solution if you can pull up floorboards etc. ... but if you can’t it 8s not much use. We couldn’t. So, we installed an 15 litre Ariston under counter heater on a timed fused spur. Much cheaper and easier and achieves the same effect.

  • @sween187
    @sween187 4 роки тому +2

    Mount the two sets of copper pipes together and insulate them as 1 unit, that way the return is being heated by the pipe going to the sink, (might help)

    • @sr.gateau
      @sr.gateau 11 місяців тому

      The return would always be somewhat cooler than the supply so it wouldn't really help.

  • @simonrous2191
    @simonrous2191 2 роки тому

    I worry about the cost of the electricity of running the pump many hours a day plus heat loss from the circuit. Would it be better to have a local mini tank near the kitchen tap or an on-demand hot electric tap?

  • @nedbundy4956
    @nedbundy4956 2 роки тому

    Does this pump need a permanent live feed or switched live ??

  • @barryhill9051
    @barryhill9051 2 роки тому

    Hi 👋 I'm just a DIYer and my hot water is on a combination boiler on the ground floor about 50mt from my on suite on 15mm copper and takes around 90sec to reach the tap.
    How can I resolve this.
    Thanks Barry.

  • @seanesslemont6332
    @seanesslemont6332 4 роки тому +1

    How do I buy one of those t shirts? Love your videos by the way

  • @mitch3683
    @mitch3683 3 роки тому

    Hears one for ya, combo boiler on grd flr, bath 3m at 1st floor. Fully open hot tap and water is Luke warm, turn tap down water heats up and takes forever to fill bath🤷‍♂️ any ideas how I can achieve hot water whilst opening the tap full on 👍

  • @loafersheffield
    @loafersheffield 4 роки тому +1

    James, I recall that you have worked in commercial. Have you ever suffered at the dictatorial and tyrannical whims of the bottom inspec.. Ooops! Water inspectors? The external auditors who supply certificates of compliance for insurance purposes.
    Goldilocks! Not too hot, not too cold and min 50 deg c, 60 deg max after 1 minute of opening any hot water draw off point.
    I have to maintain 3 fortics and a huge, vented, copper cylinder for a bingo hall. 34 hand wash basins, 3 cleaners sinks and 5 huge, deep stainless steel catering sinks.
    That's before the 32 bogs and 3 staff showers!
    I had to maither and cajole the manager for the dosh to change a sec ret pump fer 3 months as the water at the furthest draw off points was struggling to get to min 50 within the 1 minute required time. Even when I mentioned possibility of bacterial contamination on the now dead pump return leg, as the pump had gone kapput. Oh, the irony as the business opened up last week with easing of the lurgy lock-down and there are perspex panels and directional pedestrian arrow indicators everywhere.
    George Carlin, Fear of germs.

  • @nicodavies3725
    @nicodavies3725 4 роки тому

    There’s a few ways 1. If you’ve got a combi boiler could be due to low pressure 2. The main heat exchanger could be blocked with magnesium and calcium effecting the heat transfer. 3. The stop tap may not be fully open. 4.if you have a water heater the thermocouple may need replacing or cleaning and 5. If you’ve an unvented cylinder and the property is quite large with a numerous amount of en-suite and bathrooms then you may need to install a secondary return on the hot so that you’re not drawing off so much cold water.

    • @nicodavies3725
      @nicodavies3725 4 роки тому

      If you have some type of primary multipoint water heater in the attic or somewhere where you’ll lose heat then maybe the pipes need lagging.

  • @christm3
    @christm3 4 роки тому

    What temperature should I be heating my hot water tank up to? My boiler is set to 62c currently.

  • @muvy-rv6gt
    @muvy-rv6gt 4 роки тому

    What was the duo impact and sds drill you had?

  • @philippeantonietti
    @philippeantonietti 4 роки тому

    I got a leak in my hot water copper pipe which circulates the water in my home radiators, the temperature is about 60c, would be a problem if i use Flex with fast connections to repair ?

  • @dougiemiller5030
    @dougiemiller5030 4 роки тому

    James, great informative videos. How do I get in touch with you privately about an idea I have related to this?

    • @plumberparts
      @plumberparts  4 роки тому

      dougie miller Hi Doug. Send an email to info@plumberparts.co.uk

  • @trick17und4
    @trick17und4 4 роки тому +1

    Did you have a secondary return connection at the hot water cylinder? If not how did you connect that last bit in the loft?

    • @plumberparts
      @plumberparts  4 роки тому +1

      Yes there’s one on this cylinder especially. Works a treat!

    • @trick17und4
      @trick17und4 4 роки тому

      plumberparts thanks for the reply. Basically you took the hot feed all the way down to the kitchen where you connected onto the plastic part and the return is the new pipe you connected to the secondary return at the cylinder?!?! The pump should be pumping towards the cylinder right? Have you checked the Wilo stratos?

    • @trick17und4
      @trick17und4 4 роки тому

      Could you not use a cylinder without a secondary return tapping and tap at the bottom in so you will keep the whole cylinder hot

    • @spencerwilton5831
      @spencerwilton5831 4 роки тому +1

      trick17und4 No, that will destroy the stratification in the cylinder, instead of properly hot water at the top ready for use, and cool water at the bottom, waiting to be heated, you would end up with a whole tank of lukewarm water every time someone had drawn a bit off. It would also ruin the efficiency of your boiler- you want the return to the boiler to be as cool as possible, i.e. From the cooler bottom of the tank.

    • @trick17und4
      @trick17und4 4 роки тому

      Spencer Wilton the problem I find is that Vaillant cylinders haven’t got a secondary return connection and when I ask some engineers they’ve told me they would connect back into the cold mains at the bottom ... anyway, I get your point and appreciate your explanation which I definitely like!! Thanks for that

  • @richardkingadi5511
    @richardkingadi5511 3 роки тому

    I'm wondering if there is any way of doing this with a gas Combi boiler ??

  • @bmaher45
    @bmaher45 4 роки тому

    Off topic is your hot water cylinder mains fed and if so. If you wanted to move gravity fed cylinder into attic what would I need to do and can't use mains fed water for cylinder as it isnt allowed in Ireland. Take it you need single pump for tank into cylinder in attic??

  • @smitajky
    @smitajky 3 роки тому

    I just have the tank near the kitchen tap which is the one that is used frequently. About 1m of pipe. It takes half a litre of water to get the hot through. About 2 to 3 seconds. It does take more to reach the shower but we take our showers consecutively without turning off the water so it takes a half a bucket of water initially. You see not only do we need to save water as we live on tank water in an arid environment but we ALSO need to avoid wasting heat as we grow and chop our own firewood. We don't want to waste that either.

  • @petervine3488
    @petervine3488 3 роки тому +5

    For a plumber, why is the hot on the right, when most people expect the hot on the left?

    • @Peter-un8no
      @Peter-un8no 3 роки тому

      It is hot and cold on the right on his tap, he pulled the lever out to tun on, the left is for filtered water

    • @petervine3488
      @petervine3488 3 роки тому +1

      If that's the case, I stand corrected, just looked wrong when I saw him open the right tap for hot water, must take a while to get use to opening a tap one way for hot, and another way for cold.

    • @danquestnorth768
      @danquestnorth768 2 роки тому

      Saw that & thought they must plumb hot & cold reversed in the UK! 🤔

  • @rickbaguley7997
    @rickbaguley7997 3 роки тому

    Love all your video's :)

  • @bennywild1985
    @bennywild1985 4 роки тому +1

    Have a cuppa coffee, have a tea... madman

  • @stephenporter5796
    @stephenporter5796 3 роки тому

    I've a combi boiler, 6ft from the kitchen sink. despite the boiler firing up on the turn of the tap it takes at least 1/2 minute before the water is up to a warm temperature.

  • @Cablesmith
    @Cablesmith 4 роки тому +2

    I noticed it kind of stalled on 54° for about 6 seconds 😩 making it 17 seconds to get 55.... but obviously 54 is still hot enough at about 10 seconds 😂

  • @chrisharris1442
    @chrisharris1442 3 роки тому

    How would I achieve this if I have a combo boiler?? Is there anything I could do?? Is there such a thing as a pump operated by a flow sensor that only operates when the hot tap is opened ????

  • @dingbatbell01
    @dingbatbell01 4 роки тому

    I have this problem but I have a combi. Any solution for that?

  • @davidpotter3717
    @davidpotter3717 3 роки тому

    Would it have been easier to install a small instantaneous electric water heater under the sink?

  • @hakimvlogs6579
    @hakimvlogs6579 Рік тому

    Would the added cost be worth 17 seconds difference ?

  • @CarlosArruda77
    @CarlosArruda77 4 роки тому +1

    Hot water tap on the right hand side of the tap? Come on!!! lol... Keep them videos coming please.

    • @plumberparts
      @plumberparts  4 роки тому +1

      Look more closely at the tap...it’s a three outlet one.

    • @CarlosArruda77
      @CarlosArruda77 4 роки тому +1

      @@plumberparts to be honest I'm not at all bothered buddy. Just keep them videos coming please. Love them. P.S. No insult meant.

    • @CarlosArruda77
      @CarlosArruda77 4 роки тому

      It's people like you that I take my hat out to. I honestly don't know how do you make it happen. Being a plumber and youtuber how do you find the time to fit it all in. Well done man. Well bloody done. Don't forget, keep them videos coming.

    • @simonj48
      @simonj48 4 роки тому

      I grew up with my bathroom tap having hot water on the right hand side, and still is. I always got confused when friends would complain about the taps being weird. I've never known taps to be the 'correct' and only way round.