Adding Electrical Wall Outlet on Opposite Side of Wall - Easiest Method

Поділитися
Вставка
  • Опубліковано 28 сер 2024
  • !!! DISCLAIMER !!! THIS IS THE "EASIEST METHOD", but not the safest. Please note below to use Fully Enclosed bracket instead of Orange Low Voltage bracket.
    Detailed how-to video installing additional electrical wall outlet on opposite side of existing one.
    Easily add additional outlet on opposite side. Whole process took less than 30 min.
    PARTS LIST:
    GFCI Outlet: amzn.to/2OyhvqJ
    If you don't need GFCI you can just buy this: amzn.to/32mlsqE
    14/2 Indoor Electrical Cable: amzn.to/3fykGuH
    Wall Outlet Bracket (WARNING THIS IS FOR LOW VOLTAGE - THERE IS RISK FOR USING THIS - I AM NOT RESPONSIBLE): amzn.to/38XxuYQ
    TRY USING THIS HIGH VOLTAGE WALL BRACKET INSTEAD: amzn.to/3eqm2Gs
    TOOLS:
    Voltage Tester: amzn.to/2B1H4O1
    Electrical Plier / stripper: amzn.to/3960vlh
    #walloutlet #electricaloutlet #addoutlet

КОМЕНТАРІ • 75

  • @bebaker
    @bebaker 3 роки тому +98

    ⚠️ This is a faulty install. When installing a second box, it has to be offset from the existing as they are too deep to back-up to one another. An offset of several inches is needed to ensure they don't interfere with one-another. I'd suggest correcting it by patching the new location and installing the proper components several inches away using an enclosed box. For the safety of others, I'd suggest deleting this video too.

    • @CorneliusBueller
      @CorneliusBueller 3 роки тому +11

      It's not too deep if you use a low voltage frame like he did. It's just a fire hazard and a bad idea for everyone involved.

    • @bebaker
      @bebaker 3 роки тому +6

      @@CorneliusBueller I think you’re missing the idea that installing a high voltage line into a low voltage frame is not an acceptable practice. Those lines should be enclosed.

    • @CorneliusBueller
      @CorneliusBueller 3 роки тому +9

      @@bebaker I apologize if my sarcasm wasn't thick enough.

    • @lexxstarr9700
      @lexxstarr9700 2 роки тому +2

      @bebaker I agree with you!! This DIY GEEK has no clue what danger he just created for his family living there. Just a matter of time until a fire breaks out from that improper and dangerous install!!

    • @jaredhammonds8255
      @jaredhammonds8255 2 роки тому

      So if I want to pigtail off of an outlet by my front door to put one in my garage, would that be OK? The original is up against a stud and I intend to place mine on the opposite side of the wall and the opposite stud

  • @rayyoudontneedtoknow6887
    @rayyoudontneedtoknow6887 3 роки тому +18

    People I am a retired electrician everything this guy is doing is highly illegal and very dangerous don't follow his instructions

  • @Shadi2
    @Shadi2 4 роки тому +37

    Unfortunately, that is an Orange low voltage box not safe for 120V+ outlets. You would need to use a fully enclosed "new work" box. Also, drilling holes in a box compromises the fire rating, use the appropriate knockouts. If there's a fire and the investigator traces it to your hack job, your insurance will not pay out.

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  4 роки тому +1

      @Shadi2 is correct, please see my description, this is the easiest way (using the orange low voltage bracket), but the best way and protection is to use a fully enclosed box. As I also provide a link for in the description. However you have to find a stud or way to secure the fully enclosed box.

    • @Shadi2
      @Shadi2 4 роки тому +4

      @@DIYGEEKTEXAS "New Work" enclosed boxes have tabs that hold to the drywall, just like the orange box. I usually glue in thin shims above/below on the inside of the outlet hole, so the tab holds against the board rather than drywall.

    • @charleswloy
      @charleswloy 3 роки тому +4

      ​@@DIYGEEKTEXAS I understand when an experienced worker risks only their own life with some questionable technique, but using this low-voltage non-box risks the lives of everyone who ever lives in that home. And they'll likely never know until the fire investigation. Disgraceful.

    • @bb590
      @bb590 3 роки тому +2

      @@DIYGEEKTEXAS You are showing people exactly how to IMPROPERLY install an electrical box! This video should be deleted!

    • @kittyhawk7060
      @kittyhawk7060 2 роки тому +2

      @@DIYGEEKTEXAS There are electrical boxes that now secure themselves to the drywall (sheet rock). They do not need to be anchored to a wall stud. They're for finished walls where you can not use a hammer to drive the nails into a wall stud.

  • @flxmkr
    @flxmkr 4 роки тому +28

    If you don't have a friend 🥺, you can plug in a loud radio and flip breakers until the music stops.

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  4 роки тому +1

      @flxmkr Awesome idea! Loud Radio! LOL

    • @jamm7979
      @jamm7979 3 роки тому +2

      I used a Shopvac !! Thanks for the idea !!

    • @wesw3621
      @wesw3621 2 роки тому +2

      Dude you’re brilliant.

  • @jironman21
    @jironman21 3 роки тому +21

    You need to pigtail those grounds homie. It’s a bad idea to joint them under the screw like that

  • @epia125
    @epia125 Рік тому +3

    That orange wall bracket is a low voltage bracket. Used for phone or network jacks, not 120v wiring.

  • @lancemiller3255
    @lancemiller3255 2 роки тому +5

    All 110 connections need to be in a box. You're using a wall mount bracket for low voltage or data.

  • @whatsthedileo
    @whatsthedileo Рік тому +2

    See this is why UA-cam getting rid of the dislike button was bad. Because people do dangerous things like this and there's no way of telling that it's the wrong way and dangerous unless you read the comments.

  • @charleswloy
    @charleswloy 3 роки тому +23

    It is ridiculously unsafe to push 120 volts through a low-voltage box intended for telephone or tv. Please take down this video.

    • @rithlim6016
      @rithlim6016 3 роки тому

      Isn't the GFCI outlet he's using meant to support up to 20amp as indicated by the horizontal slit on the neutral side? I think that gives a false impression of supported voltage; that's dangerous.

    • @KevinCoop1
      @KevinCoop1 2 роки тому

      @@rithlim6016 You are correct. 15 amp branch circuit 15 amp devices. 20 amp multiple receptacles 15 or 20 amps. A dedicated 20 amp circuit with single receptacle 20 amp only.

  • @Pilot_the_Dune
    @Pilot_the_Dune 3 роки тому +5

    You are keeping this up for the views? My guy, take it down. You can put all the disclaimers you want but its still wrong to show people how to do it wrong. You should change the title to say "Adding Electrical Wall Outlet on Opposite Side of Wall - The Dumbest and most UNSAFE Method" if you plan on keeping it up.

  • @flxmkr
    @flxmkr 4 роки тому +3

    Are you sure there wasn't a dog standing on the other side of the wall when the drill bit went through? I heard a suspicious "Yap".

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  4 роки тому +2

      @flxmkr I do have a good, but he was not hurt Hahaha.. I should put a disclaimer: No animal was hurt during the filming of this video. LOL

    • @flxmkr
      @flxmkr 4 роки тому +1

      DIY GEEK 😂🤣

  • @edpippin
    @edpippin 4 роки тому +3

    Many vacuum cleaners have a 13-15 amp startup

  • @docdokes361
    @docdokes361 3 роки тому +5

    I think this video was made by fire extinguishing company...

  • @comesthru
    @comesthru 11 місяців тому +1

    This install is against the code, You are not allowed to enter an electric box without running the wire thru a stress relief fitting.

  • @brandonyoung7760
    @brandonyoung7760 2 роки тому +2

    Are you using 14/2 cable with a 20V plug?

  • @johnjkizer6399
    @johnjkizer6399 Рік тому +1

    Not trying to be rude but you did a lot of explaining but when you come to installing the outlet you showed nothing but some fast clips of nothing and music. Simple explanation and good videos of what is actually being would be best. Thanks

  • @waltermojica222
    @waltermojica222 Рік тому

    Pretty cool 😎

  • @seandarcy2351
    @seandarcy2351 2 роки тому +1

    Okay, this may be a bad idea for 120v electrical outlet, but this will help to do the same for my internet. Some numbskull put my only internet outlet box in the kitchen. So I'm going through the wall opposite of it into the living room for my wifi. Why would they design the home for the wifi to sit under my cereal cabinet on the countertop???

  • @FrankoUSA
    @FrankoUSA 3 роки тому +3

    THE "EASIEST METHOD", but not the safest.😂

  • @mongoosegristle
    @mongoosegristle 7 місяців тому

    I needed 12" of 14-2, so I bought 100'. You can easily eliminate the GFI...quit peeing on the wall!

  • @shawnhorton2000
    @shawnhorton2000 3 роки тому +2

    Seriously you didn’t even try to line up the template on the new hole you cut it’s so crooked it’s ridiculous how horrible

  • @colmsmith6686
    @colmsmith6686 3 роки тому +2

    Please take this video down. If people watch this video and don't read the comments, they subject themselves to fire risk.
    I appreciate your willingness to share, and your video is great, but please do the right thing.

  • @larryprice6321
    @larryprice6321 Рік тому

    Thanks that's awesome

  • @terencegist2768
    @terencegist2768 5 місяців тому

    That orange box is for low voltage only

  • @KevinCoop1
    @KevinCoop1 2 роки тому +1

    List of violations of NEC. Low voltage frames are not tested and listed for 120 volt devices. Installing receptacles open back is not legal unless the devices are tested and listed for the installation. That receptacle is not. Drilling holes through the back of the box violates its listing. Must be listed. Connecting two ground conductors under one screw is a violation. Installing a 20 amp receptacle to a 15 amp branch circuit is a violation.
    It is very sad that people having no idea what they are doing put this type video on UA-cam to try and make money.

  • @rruizproductions
    @rruizproductions 3 роки тому +2

    What you call a “rig it” install. Completely out of code.

  • @dougwitte765
    @dougwitte765 10 місяців тому

    Great, working in bare feet.

  • @Dominick_84
    @Dominick_84 Рік тому +1

    Absolutely cannot use the orange low voltage box !!!!!!!!!!!!! I am a licensed electrician this is a code violation and a fire hazard!!!!!!!

  • @junfabi1
    @junfabi1 2 роки тому

    Correction: you do not have an OUTLET, for your plug.

  • @robertcasanova2113
    @robertcasanova2113 Рік тому

    Very helpful vid, thank you!

  • @nickp778
    @nickp778 2 роки тому

    Good thing your using rubber gloves… need those when your not wearing shoes 👀👀

  • @edwinlau9257
    @edwinlau9257 3 роки тому +1

    Do not install this way in north america. This does not meet code

  • @nope_not-showing-my-name
    @nope_not-showing-my-name Рік тому

    Totally illegal to use low voltage bracket with 110V.

  • @mikeclarke3005
    @mikeclarke3005 2 роки тому

    People should not post DIY electrical unless professional/licensed, this is a hazard install, not to code at all. if failure of that new electrical outlet do not have the proper box for containment. and some insurance companies, if DIY electrical is a cause for a house fire, good luck getting that claim.

  • @DIYGEEKTEXAS
    @DIYGEEKTEXAS  4 роки тому +1

    Please see Video Description for PARTS LIST

  • @arealmaintenanceandrepairl1103
    @arealmaintenanceandrepairl1103 2 роки тому

    Wrong ! Someone invent a double sided gang box for for this type of situation so no one does this unsafe hack

  • @mitolu3326
    @mitolu3326 2 роки тому

    This will not pass city i spection as this is illegal. Wall electrical box need be min. 24 inchs away.
    This is fire hazard installation.
    Video is leading illegal way. Should be removed.

  • @anthonychase4945
    @anthonychase4945 8 місяців тому

    Make sure your wear gloves. But no shoes.

  • @metzger210
    @metzger210 3 роки тому +1

    Nobody do this please. So illegal and dangerous.

  • @user-ti6vb5py4o
    @user-ti6vb5py4o 7 місяців тому

    Illegal asf lol. You can not use low voltage boxes to install and outlet. And you should of used size12. Pls don’t this this pls

  • @BibleExposition2022
    @BibleExposition2022 3 роки тому

    The new extension outlet could have been set up with the orange bracket and wired with electrical wires first then push it through the other side and wired together with the old outlet. I did that with mine and it was done much easier.

  • @MichaelWarner91
    @MichaelWarner91 3 роки тому +3

    When you call neutral "common" you shouldn't be working on it.

  • @MAKAVELI69
    @MAKAVELI69 Рік тому

    Oh NO……!

  • @camarokid1980
    @camarokid1980 3 роки тому

    This guy has no clue Beware

  • @farmerdave7965
    @farmerdave7965 4 роки тому +1

    FAIL !!!

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  4 роки тому +1

      Please kindly explain why you say this is a FAIL!!! ?

    • @farmerdave7965
      @farmerdave7965 4 роки тому +1

      @@DIYGEEKTEXAS Receptacles must be enclosed in box.

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  4 роки тому

      @@farmerdave7965 That makes sense. I will make sure to use 'new work' box next time. Thanks

    • @charleswloy
      @charleswloy 3 роки тому +3

      @@DIYGEEKTEXAS Dude, if you love the family that lives in that house, you'll replace that death trap with the right box and not leave it uncorrected until "next time".

    • @DIYGEEKTEXAS
      @DIYGEEKTEXAS  3 роки тому

      Charles Loy good idea I will make a video correcting this. Thanks