how to program a Drive 500_600 Gate Motor

Поділитися
Вставка
  • Опубліковано 3 лип 2022
  • In this episode, we go through The runtime setup of a Drive 500_600 Gate Motor
    Channel sponsors:-
    Rsec Security Equipment Center
    www.rsec.co.za
    / rsecequipmentcentre
    / rsecsecurity
    Music:- One Thing - Roa (No Copyright Music)
    Metro - Yung Logos (No Copyright Music)
    Link to Products
    rsec.co.za/product/et-nice-dr...
    Please comment, like, share and subscribe to the channel
    Follow me on Instagram:- @Nicks_nd_Tricks
    Follow me on Facebook:- / nicksandtricks
  • Наука та технологія

КОМЕНТАРІ • 39

  • @FlyByR10T
    @FlyByR10T 2 роки тому +1

    Awesome!

  • @enricotheunissen2653
    @enricotheunissen2653 10 місяців тому +2

    Can anyone assit me i am having a problem with my remote setup on my et 500_600 it says comms error when i press the square

    • @nicksandtrickssa
      @nicksandtrickssa  10 місяців тому

      thank you for the comment, but i will have to look into that issue, have not yet come across this issue before

    • @nicksandtrickssa
      @nicksandtrickssa  10 місяців тому

      Comms error is usually a faulty controller. RF comms error can sometimes be cleared by cycling the power.

  • @2226cc
    @2226cc Рік тому +1

    I noticed in advanced setup menu that there is a setting for number of limits. Is it possible to run a 2nd limit on the gate for the the open limit? I have 1 limit actuator installed for the right limit, and have done the limit setup, but the thing still heads too far when opening. Possible to add 2nd actuator for the left limit?

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for the comment. The unit should be set to single limit. On the very rare occasion it is left on dual to test the operators. Does the limit overrun during or after setup?

    • @2226cc
      @2226cc Рік тому +1

      @@nicksandtrickssa Sorry for late reply. It overran after setup. On inspection we found the FETs had blown. It also started to eat up fuses and whoever installed the gate didn't do to well with mounting the leading wheel. Motor would run at full speed no matter what. Could only be fixed with a new board. So we did that, welded down the leading wheel and then grinding down the paving a bit where it was riding up (only a problem now after the wheel was welded). So far so good.
      Would ve really useful to have 2 limits instead of gate length calculation. But for now, just happy the darn thing works. :)

  • @apgkpsdgksd
    @apgkpsdgksd Рік тому +1

    Hi, i have a problem, the motor display say "limit fault open manual reléase " how i can fix this problem, please help me.

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for the comment Eduardo, is it giving both errors? Is the green and white connected on the board, is the door closed?

  • @nevillewatson8718
    @nevillewatson8718 11 місяців тому +1

    Thank you for the info
    My problem is that the gate runs halfway when it opens and on closing the gate reverse automatically without pressing the remote any help please

    • @nicksandtrickssa
      @nicksandtrickssa  11 місяців тому +2

      Thank you for the comment Neville, you have to turn up the force, please note that turning up the force will require a bigger force to stop the gate...
      If the gate always stopped at the same point, it can be the track or rack, check the gate wheels as well. Last thing to check is the spacing between the rack on the gate and the cog. Should be a even spacing throughout the travel of the gate. Lastly a fresh battery will also help.

    • @nevillewatson8718
      @nevillewatson8718 11 місяців тому +1

      @nicksandtricks1849
      Thank you so much
      I see that one of the wheels not functioning properly

    • @nicksandtrickssa
      @nicksandtrickssa  11 місяців тому

      @@nevillewatson8718 no problem, a like and sub would be appreciated 👍

    • @rowenramnath2016
      @rowenramnath2016 6 місяців тому

      ​@nicksandtricks1849 I want to know how must it be connected at the remote. It just opens at the motor like you did before

  • @supaflyracingza
    @supaflyracingza Рік тому

    Same problem, after setting close range the gate closes to far on second run the i keep getting error

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for your comment, the gate uses the magnet for the closed position, check the limit light manually to see if it turns on, if not check you magnet on the rack.

  • @Nunu-wx6yn
    @Nunu-wx6yn Рік тому +1

    Hi, I'm trying to set runtime but I'm getting encoder stall error... How do I resolve this please?

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      ok soooo, encoder stall is a bit tricky, power down completely, unplug all green connectors, and remove the card, you have to check inside the casing if anything looks and smells damaged, sometimes when rebooting the card and unplugging and putting back together it starts to work, the loadshedding causes the pcb to do this error. also does it happen when power is off or while there is power?

    • @krisgarces95
      @krisgarces95 9 місяців тому

      The same thing happened to me and it was just a matter of cleaning the engine carbons, check to see if they are worn if not, just clean them well.

  • @sakhiledube3573
    @sakhiledube3573 Рік тому

    If I set the RUNTIME it say HOLIDAY Lockout LOCKED, how can I fix that problem.?

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Good day Sakhile
      You will have to program a holiday lock button on your remote
      ua-cam.com/video/7g0PeErNSlA/v-deo.html
      When u get to the button trigger type, scroll to holiday lock out instead of button trigger
      Once u have a holiday lock button programmed, do the following...
      Press the holiday lock button, and while it is beeping, u press and release a normal button trigger button
      It will now cancel the holiday lock

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      ua-cam.com/video/isnt9v_EIA0/v-deo.html

  • @claudionunez5963
    @claudionunez5963 Рік тому +1

    Hello, I have an ET Drive 500/600, and when I want to program the opening, after selecting the option "Set Close Direct Press < or >" and the message "Finding closed limit" comes out, but instead of the motor moving, this error message "Check motor conn limit" comes out, and I don't know what it is about.

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for the comment Claudio. Please swop the 2pin connectors of the battery and the motor caabke connectors. Sometimes the motor connector is overtightened and it can have an effect on the setup

    • @victorkapesi1014
      @victorkapesi1014 Рік тому

      @@nicksandtrickssa and it can be swop those 2 pin from battery and the motor we are using drive 500 ET gate motor

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for your comment Victor, it is for the Drive 500/600 only, is has the same green 2pin connectors, what seem to be the issue your having?

    • @victorkapesi1014
      @victorkapesi1014 Рік тому

      @@nicksandtrickssa as of now am at the gate i want to sort it out this problem, but i cant see any 2 green pin there please help

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      What is the issue with the gate motor? Do you have a blue cover or a green cover?

  • @hymanjulius6524
    @hymanjulius6524 Рік тому

    drive 600 sliding gate shows Lim fault,manual open to release,but if doing show gate does nothing and stil shows the shame message

    • @nicksandtrickssa
      @nicksandtrickssa  Рік тому

      Thank you for the comment. You will have to look at the limit magnet on the rack, on the board there is a limit l and a limit r. When the gate is at the limit magnet, the limit light must be on. If not contact your installer to assist