How Pro Electricians cut wires into boxes and make it look clean!

Поділитися
Вставка
  • Опубліковано 13 лис 2022
  • Watch this video to learn how to cut wires into a box like a Pro and impress your friends!
    Tools used:
    Nmd cable strippers:
    amzn.to/3B87QjF
  • Навчання та стиль

КОМЕНТАРІ • 216

  • @Icemanja2006
    @Icemanja2006 Рік тому +7

    Installation is Code compliant as per 2021 Canadian Electrical Code
    12-510-1a - NMS cable supported 300mm/12" of the device box
    12-510-2 - Stud hole is considered support for the lower cable
    12-516 - NMS cable was kept 32mm/1.25" from the edges
    10-614 appendix b & CSA C22.2 No. 42 - Switch is bonded by mounting screws to the device enclosure in this case a metal box.
    A device service loop is considered good practice during electrical rough-in, in most if not all parts of Canada. However not required by CEC and does not violate any codes for this installation.
    Just for clarification for non-canadian electricians.
    One small terminology error, the white conductor in this case is an identified conductor, not a neutral.
    Good video clear and right to the point.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Thank you. A lot of commenters find it hard to understand the entire world doesn't use the NEC.

    • @Icemanja2006
      @Icemanja2006 Рік тому +1

      @@jeremiahbullfrog9288 In normal operating conditions the intent of a neutral is to carry the unbalanced current in a single-phase system. In this case, your white conductor carries the full load current when the device is energized and is the only return path to your source in a non-fault condition. As defined in section 0 of the CEC, the term neutral in a single-phase system would only apply to a 3-wire circuit. Hope that clarifies the difference a bit better.

    • @Dog-whisperer7494
      @Dog-whisperer7494 Рік тому

      Now I know why you call it rough in . That looks as the name suggests. Rough.. Here in UK 🇬🇧 call first fix and when we fit the accessories ie socket faceplate and switch plate and light fittings we call it second fix . Also for a lighting circuit we take a feed from the fuse box to the first light then we take a switch line down to the switch the we take a feed from the first light to the next and we repeat until we have all the lights wired each lighting point haves it’s own switch end result each light fixture will have 3x 1.0mm2 twin and earth one of which is the switch line there is no neutral at the switch so the neutral wire is identified as live with a bit of brown sleeving in the UK our cable colours are brown = line blue =neutral bare copper =earth the switch wires are called switch line and switch return. At the ceiling rose we have feed in loop out and switch drop. Or or simply loop in loop out switch drop no wire nuts or other connectors are used . Except for when we take the feed to the switch .

    • @raggarex
      @raggarex Рік тому

      @@Dog-whisperer7494 Many light circuits are wired that way in Canada too, as in feeding power to the junction box where the fixture goes and then connecting the switch to that box via a switch drop. In that case you'd only have a single 2-wire cable going from the junction box to the switch box, requiring no wire joints.
      EDIT: Before people misunderstand and scream bloody murder, a 2-wire cable includes two current carrying conductors and a ground wire. Technically there are three wires, but only the current carrying wires are called out in the numbering.

    • @GWAYGWAY1
      @GWAYGWAY1 Рік тому

      Do you not use rubber grommets to protect the edges of the box?????? We also use a green and yellow sleeve to cover the short bare earth bonding wires.

  • @JP-vs1ys
    @JP-vs1ys 3 дні тому

    This is really interesting. And thank you for clarifying the loop allowance per code. That was throwing me off since in other jurisdictions it’s not allowed.

  • @seonewport363
    @seonewport363 Рік тому +3

    this is great, do some more examples with more wires coming into a box. I am always amazed at how neat electricians make complicated boxes look good. would love to see some done :)

    • @energyoneelectric
      @energyoneelectric  Рік тому

      It's in the works. So many ideas so little time. I'm on the tools full time so I don't always have time to shoot videos as much as I'd like. Thank you for watching.

  • @malcolmmarzo2461
    @malcolmmarzo2461 Рік тому +1

    The service loop is a good idea. It makes the stiff cable more flexible and easy to maneuver. Similar to plumbing pipes and hoses in very tight spaces.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I love the service loop. There have been many times when I needed to move a receptacle after it has been wired and the service loop left me just enough wire to do so.

  • @Bapuji42
    @Bapuji42 Рік тому +6

    The Maple Menace of Canadia sure be doing some weird shit with electrics.

  • @Carlg6
    @Carlg6 Рік тому +15

    I believe there's supposed to be a quarter inch of romex sheathing minimum inside the box. I'm not sure we're seeing that? And while I understand the usefulness of a service loop for extra wire, coiling backwards like that means that if you need to pull the extra wire through you can create a kink in the cable.

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому

      My exact thoughts. You create curly Q's looping it that way. I also curl my grounding around the screw for a snug mechanical bond. Probably better to loop the romex across to the adjacent stud and then back and into the box or come down an adjacent stud and curve the romex like a backwards 'S' on its side, using an external cable clamp so the wire goes straight down into the box with several inches to spare. As long as it is secured 12" from and the length of wire until the strap does not exceed 18", this is permitted by code.

    • @guyzer6197
      @guyzer6197 Рік тому +1

      @@knowledgeableharpy2329 By curling your bond around the screw you eliminate the possibility of adding a second bond wire. You also can damage the bond wire by wrapping it. Not good practice.

    • @frankdemarest2790
      @frankdemarest2790 Рік тому

      The “service loop” looks like it violates bend radius of 5x major diameter (334.24 of 2023 NEC)

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому +1

      @@guyzer6197 Nonsense. Why would I add a second wire if one is landed and I can add a 2nd in the wire nut? I've never damaged a ground wire by having a secure bond.

    • @geraldcreager4432
      @geraldcreager4432 Рік тому

      @@knowledgeableharpy2329 During our recent house reno, I encountered half a dozen metal box grounding wires that were damaged or actually broken when the wire was looped over the screw and then pulled too tight. Resulted in the box not being grounded. Of course, the number of current code problems in a 40 year old reno couldn't be easily totaled, partly because of code changes but also because, near as I can tell, they didn't enforce NEC here in the county.

  • @vince6829
    @vince6829 Рік тому +1

    Thank you for sharing your knowledge.

  • @chuyv4760
    @chuyv4760 Рік тому +1

    That's was really good.i need help figuring out to put mass wires back into a LED fixture with a E driver. Man I'm having a hard time putting the light fixture back together with all the wires in the way?

    • @energyoneelectric
      @energyoneelectric  Рік тому +2

      Ya I had that problem before too. Trying to fit too many wires into a light base that was too small. The only advice I can think of is to zip tie or tape the wires together to make the bundle smaller and easier to handle. I even try to tape the bundle down to the base. Hope it helps.

  • @adamplummer2190
    @adamplummer2190 Рік тому +12

    Interesting setup on grounds. You are allowed to use the box as connection across grounds? I'd be afraid it would loosen and want to still use a wire nut to bond the 3 as backup to the screw.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Thanks for watching, Adam. I use Eaton switches and they don't even have a bonding screw. Also, keep in mind that adding a wire nut can reduce your box fill by code.

    • @jerseyjim9092
      @jerseyjim9092 Рік тому +2

      @@energyoneelectric you're saying that wire nuts on grounds increases their box fill number from 1 for all to 2?. Never heard that before.

    • @energyoneelectric
      @energyoneelectric  Рік тому +2

      @@jerseyjim9092 Sorry I don't understand your question the way you worded it. Canadian electric code rule 12-3034 (2)(b) says that for every 2 wire nuts your box fill is reduced by 1 conductor (in my own words of course). So depending on the size of your box and how many wire nuts you already have in it... adding 1 more wire nut may reduce your box fill regardless of which wire the nut is on.

    • @jerseyjim9092
      @jerseyjim9092 Рік тому +4

      @@energyoneelectric thanks for the response and sorry my question wasn't clear. But your Canada Code reference answered my question. Unless its a recent change, our NEC doesn't count wirenuts in box fill calculations.

    • @Bapuji42
      @Bapuji42 Рік тому +1

      @@jerseyjim9092 Correct.

  • @kyzor-sosay6087
    @kyzor-sosay6087 Рік тому +1

    Fantastic video,young man,glad to see you making professional taps,instead of wagos.Good on ya,man.

  • @MrKen59
    @MrKen59 Рік тому +11

    I like the service loop - I guess you are at the mercy of your local inspector, but an extra couple inches can be a lot of help. Cutting your equipment grounding conductor around here would get dinged since you can’t guarantee someone will use a receptacle that support that technique. Well spoken and clearly demonstrated.

    • @energyoneelectric
      @energyoneelectric  Рік тому +2

      I have never been called by an inspector over service loops. It just makes sense to have them. On more than one occasion I have had to pull out some extra wire after drywallers cut them.

    • @MrKen59
      @MrKen59 Рік тому +3

      @@energyoneelectric the service loop is a great idea and no problem with it. I was concerned about cutting the ground wire short and not using the device grounding terminal.

    • @guyzer6197
      @guyzer6197 Рік тому +1

      @@energyoneelectric In ontario you need the extra service loop by code.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому +3

      @@MrKen59 that’s a slightly tricky one. Depends on the switch, if it’s the residential grade, you gotta ground the switch. If it’s a higher quality switch, and is self-grounding, you don’t have to.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому

      @@guyzer6197 well, than that explains a lot.

  • @guyzer6197
    @guyzer6197 Рік тому +4

    Would love all the electricians in the comments to post a video on how they wire and install a switch box from their country please. Would love to comment on those.

  • @buzzpatch2294
    @buzzpatch2294 6 місяців тому +1

    nice clean work

  • @Carl-tx6ek
    @Carl-tx6ek Рік тому

    Nicely said, thank you !

  • @johnmorrison1050
    @johnmorrison1050 Рік тому

    Is the loop incase the drywall guys damage the wire with the roto zip tool?

  • @johnoleary5612
    @johnoleary5612 Рік тому

    What pliers are you using

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I've had those pliers for almost 13 years... I believe they are Klein linesman pliers with fish tape puller... back from my commercial days. :)

  • @mrphotomanseattle
    @mrphotomanseattle Рік тому

    Links to the tools you are using, please.

  • @swindallt
    @swindallt Рік тому

    What boxes are you using

  • @christopheragatep7112
    @christopheragatep7112 Рік тому +3

    Not sure where this is from. But don’t you have to put an EGC pigtailed out for your switch?
    I understand bonding to your metal box, but what about the ECG?

    • @Bapuji42
      @Bapuji42 Рік тому +1

      Ya, every switch I've ever worked with has a ground screw.

    • @energyoneelectric
      @energyoneelectric  Рік тому +3

      I don't know where you are, but Eaton switches spec'd for the Canadian market don't have a bonding screw. You need to realize that not everyone on here lives in and follows the American code.

    • @icevariable9600
      @icevariable9600 Рік тому +1

      @@energyoneelectric Ah! Now everything makes sense. I didn’t recognize that box and I didn’t recognize the clipping of the ground/bonding wires before. I like that you call them bonding wires since 93% of American electricians don’t understand how the bonding wires (or equipment grounding wires) are used.

    • @Bapuji42
      @Bapuji42 Рік тому

      @@energyoneelectric I need to realize that electrical advice from the interwebs is suspect for that very reason.

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому +3

      Yes, per the NEC, you must have 6" of wire from where the wire enters the box. That's why here in the states we either use stingers or keep the ground wire real long and strip some insulation (commercial) for bonding with the screw, leaving enough to do whatever.

  • @stevend984
    @stevend984 Рік тому

    Just reaching out... I am approaching a dilemma and I cannot find any info on my next task so I thought I would reach out and see if I can get some feedback. I have and am sound proofing my middle bedroom to be my new home recording studio. The walls are secure with triple insulation including 1-1/2 rigid foam insulation sealed with insulation spray foam. This room is not only dead silent now it is completely air tight...except for my ceiling. The only thing left is the ceiling. My plan is to also apply the 1-1/2 rigid insulation sheets to the ceiling. Once done the entire room will be completely covered in 2-inch acoustic foam panels. Here's my issue. I need to drop my ceiling light fixtures down about four inches. Wiring is not a concern, but I'm not sure how to securely drop & mount the box to remount my lights to clear the double foam. Your thoughts?

    • @energyoneelectric
      @energyoneelectric  Рік тому

      Thanks for reaching out. Don't drop the box, just buy a box extension. It looks like a regular Octagon box but the back is cut out. Same thing for the wall boxes.

    • @stevend984
      @stevend984 Рік тому

      @@energyoneelectric Thanks for the feedback...but the extensions you're talking about that I've seen have no way of solidly mounting my light fixture and I have yet to see the round ones...not to mention I need almost 4 inches. Thoughts?

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I have a feeling you are thinking about the plastic spark rings which are used for boxes that are deeper inside a wall than normal, but they don't have screw mounts. I'm talking about metal Octagon extension boxes which are missing the back but still have screw mounts like a regular Octagon. Here's a link: www.amazon.com/dp/B000BQWC2M/ref=cm_sw_r_as_gl_apa_gl_i_KQSDZCS34S8MZ4M57803?linkCode=ml2&tag=energyoneel03-20
      You will need a a few of these stacked to get your desired drop. Also use longer screws if you just need that extra 1/2 inch or so.

    • @stevend984
      @stevend984 Рік тому

      @@energyoneelectric Now that's what I'm talking about! Although it seems a bit over engineered...stacking these seems like the only way to get the results I need. I just ordered them. Thanks a TON...solved a big problem for me!

    • @energyoneelectric
      @energyoneelectric  Рік тому

      @@stevend984 you're welcome, glad I could help.

  • @robertjames-life4768
    @robertjames-life4768 Рік тому

    What brand of box is that?

  • @SmallBaller
    @SmallBaller Рік тому

    IDK every switch I've wired had a green ground screw to attach one of those grounds to.

  • @alexagiyants8373
    @alexagiyants8373 Рік тому +2

    Biggest question is why wouldn’t you want to ground a switch? I understand the switch will bond to the box but all switches come with a ground screw so why wouldn’t you use it?

    • @energyoneelectric
      @energyoneelectric  Рік тому

      Not all switches come with a ground screw. I use Eaton in Canada and they don't have ground screws. Maybe in the US they do.

    • @jltaco85
      @jltaco85 Рік тому

      @@energyoneelectric Here in the u.s most motion sensors and smart switches require ground to work.

  • @thebaranecfam1903
    @thebaranecfam1903 Рік тому

    Great easy tutorial. 👌

  • @userscott
    @userscott Рік тому +2

    I love watching videos on American electrical installations, it's like going back 50 years in time but in HD.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      How so?

    • @userscott
      @userscott Рік тому +1

      @@energyoneelectric are you serious? Wire nuts and cable clamped to steel boxes, it’s just… American. Don’t get me wrong I’m a fan of the states but you boys with this archaic voltage and 60s era detail… time to progress!

    • @jsb7546
      @jsb7546 Рік тому

      @@userscott archaic voltage we literally have 240 just like Europe we just have it split at transformer with the neutral tapped in the middle that's how we get 120. It's just a safety thing anything that needs more power is just hooked up to a two pole breaker that way it can use both phases. Also how else do want us to clamp it like a clamp is a clamp I don't get it and what Romex connects work too. Stop bitching about wire nuts they do perfectly fine if used properly wagos are great and save on time and all but there's nothing better than a nicely twisted connection I don't have to rely on some bus bars in the wago that can fail it's just a straight wire to wire connection. Y'all European sparkys need to chill the fuck out.

    • @userscott
      @userscott Рік тому

      @@jsb7546 head buried firmly in the sand! Love it! 🤓

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому +1

      Don't lump us in with that wire job. He is Canadian. We adhere to the National Electric Code, which does NOT permit what he did.

  • @tomburke2697
    @tomburke2697 Рік тому

    Since when don’t you need a ground wire to the switch?

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I keep getting the same question over and over about the ground wire to the switch. Some switches spec'd for the Canadian market don't have a ground screw. Check this out to see what I mean: wiringdevicesupport.eaton.com/Switches/68689783/Why-do-the-decorator-switches-show-a-grounding-screw-when-there-is-no-screw-on-the-ones-i-bought.htm

    • @tomburke2697
      @tomburke2697 Рік тому

      Ok. I had no idea that other areas would not require a ground. Thanks.

  • @Sparkeycarp
    @Sparkeycarp Рік тому +3

    Why the tiny metal box? What about box fill? Short grounds are useless for future. I do like the service loop for future work. I guess that makes up some for your short grounds. Here in the U.S. we have to put all our grounds together and ground the box and the device. Also, I was taught to strip an inch or more to twist wires together with my linemans at the last 1/4 inch or so and cut the damaged part off so all the twisted part is a smooth connection going into the wire nut. The longer section you strip the more you can grab for multiple wires and twist. Laying them in as you go. I was hoping you were going to explain how to organize a multi-gang box by squaring up the wires as we called it.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      The box is not tiny, it's a single gang 2304 box with the bubbled out sides for extra space. There is no issue here with box fill. In Canada we also ground devices such as lights and receptacles. Switches can be grounded if a bonding screw is present, however, if the switch doesn't have a bonding screw or wire then it will be bonded through the metal of the box where the switch tabs touch the box. In case of a plastic box, there is a metal tab running from the bonding screw of the box up to the screw hole where the switch gets secured. In the future I can show how I do a multi gang box. Thanks for watching!

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому

      I also strip them long and then snip at an angle for good bonding in the conical wire nut.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому +1

      @@energyoneelectric you must use a different code, I’ll literally looking at 334 & 404.9 (b)(1)

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому

      I have the handbook, so I can take a photo if you want, you’re only allowed to use a switch as your ground if it has a grounded yolk. Which you seem to be glossing over.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I'm using the Canadian electrical code

  • @briandillard8125
    @briandillard8125 Рік тому +1

    All wire shall be minimum 6" in length from where they enter box and if box is less than 8" in any direction of opening it shall extend minimum 3" from opening. The cable sheath shall extend minimum 1/4" past cable clamps. Need to secure cable not more than 12" from cable connector by length of wire. All devices with ground screws need to be bonded with wire (this is not an surface mounted box and cannot use exception in 250)

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      There are no code violations in this video according to Canadian electrical code, where I'm located.

    • @briandillard8125
      @briandillard8125 Рік тому +1

      That's great, my comment is for people in America watching this to let them know there violations to the national electrical code here. Yes, I am an inspector. I call code violations for a living, in the United States.

  • @robertgregory2618
    @robertgregory2618 Рік тому +2

    The loops are just not necessary and look sloppy. In all my years and tens of thousands of outlet make ups, have never needed extra length of wire. Imagine the cost of copper being wasted on a large house. Waste of time also. I can only imagine what a 3 or 4 gang switch would look like. Sorry but that is my opinion..You picked the best trade out there and I am happy for you in that respect. Plastic boxes are far quicker but maybe they don't allow them up north.

  • @sigcrazy7
    @sigcrazy7 Рік тому +6

    Are you in Canada where metal boxes and switches without an EGC are common? For American viewers who are working with plastic boxes, NEC 404.9 requires the switch to be connected to the EGC. While this video would comply due to the use of the metal box, it would not if he were using a non-conductive (I.e., plastic) box. As someone who has done a bit of remodeling on older installations, I cring watching you cut back all the EGCs. Couldn’t you show a future brother some love and leave at least one longer tail? At least there’s service loops so more could be pulled in to extend the ground, if required in the future.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Yes I am in Canada. I'm not familiar with American electrical codes other than hearing that they have a lot of similarities with Canadian codes. The plastic boxes I use here have a metal tab running from the bonding screw to the screw hole where your switch would be screwed into, carrying the bond to the metallic parts of the switch. Sometimes my customers ask me to install a dimmer switch, which has a bonding wire, so I just put it directly under one of the bonding screws, no need for a longer bonding wire... but I do understand your reason for wanting a longer bonding wire left in the box. Thanks for watching.

    • @wadecrawford6445
      @wadecrawford6445 Рік тому

      Yes, I agree. Also to note, insulation should be in the box but not more than a quarter inch? And all wires should be at least 6 inches long from the back of the box if I remember correctly, for American NEC anyways, right?

  • @StorminBriski
    @StorminBriski Рік тому +1

    One thing I noticed about these american back boxes compared to the UK versions is the Cable Clamp. We don't have these, I think they are a good idea.

    • @scottwilling5315
      @scottwilling5315 Рік тому

      It's mighty handy eh? (Legally required national self-identification.)
      I wonder if you'd still like it if you got to try one. That's not an implied judgement - it would just be interesting to see if you'd be impressed or recoil in horror when you saw one in the flesh.
      I spent a little time in the UK back in the '90's, and was most impressed by the standard appliance plugs and receptacles there. Our garden-variety plugs are rather lacking by comparison. In particular, they don't stand up well to the way many people treat them.
      Cheers 🇨🇦

    • @StorminBriski
      @StorminBriski Рік тому

      @@scottwilling5315 I’ve been off the tools for a few years now. Desk Jockey! Our standard metal back boxes are 25mm but you can get 35mm and 47mm. The cable entries are just 20mm “knockouts” that we add a rubber grommet to. We also have plastic “cavity” boxes that we use on plasterboard walls. These have plastic parts you can snap off. Neither of these have any form of cable clamp.

    • @scottwilling5315
      @scottwilling5315 Рік тому

      @@StorminBriski That's fascinating, thanks for taking the time to respond. We have loads of boxes with round knockouts as well, but we're required to install in that hole some sort of "connector" that clamps the cable.
      I put "connector" in quotes because I found that terminology surprising when I came to the trade from an electronics background. In trade lingo here, a connector is purely a mechanical device that ties the cable to the box, and the conductors are electrically terminated within by separate means. In electronics a "connector" makes the electrical connection(s), may or may not have a strain relief function, and is usually unpluggable. Different class of animal altogether.
      You left out a key detail: what country or general geographical area are you in? Also, what sort of support is required (staples e.g.) outside the box?

    • @StorminBriski
      @StorminBriski Рік тому +1

      @@scottwilling5315 I am from the UK. You would normally use capping to support the cable in a chase or on a block wall. In a void you would need cable clips but in reality people omit these so they could pull a new cable in if required in the future. You are also required to use metal support for cables that go over escape routes. (So they can’t come down in the event of a fire)

    • @scottwilling5315
      @scottwilling5315 Рік тому

      @@StorminBriski Cheers

  • @szaki95
    @szaki95 Рік тому +2

    WAGO connectors make the neatest installs.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I use wago connectors for some things, but I think I'm just more used to wire nuts for most things.

  • @bosatsu76
    @bosatsu76 Рік тому

    Are plastic boxes considered cheesy?

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Plastic boxes are fine, I just don't like using them myself.

    • @bosatsu76
      @bosatsu76 Рік тому

      @@energyoneelectric First... Thanks for the quick reply... Final question. What tips the scale for you towards metal..

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      @@bosatsu76 first i want to mention that I use plastic boxes with gaskets on all exterior walls and ceilings (building code here). I find it harder to insert the cable into the tabs on plastic boxes. With our cold climate sometimes the tabs even break when you're putting pressure on it. Then the little bumps next to the ground screws are always at the tops and bottoms in plastic boxes so I'm forced to bend the ground wire 90 degrees to make it work. Metal boxes the bumps are always on the left and right of the screws making it simpler in my opinion. Next if you need to remove the cable for some reason it's easier to loosen the clamp on a metal box and remove instead of trying to bend those plastic tabs to free your wire. Just personal preference I guess..I may even give plastic boxes a try on the next house to see if I change my mind.

    • @bosatsu76
      @bosatsu76 Рік тому

      @@energyoneelectric Great stuff... Thanks... I just do a little work around the house so far, so plastic will do me just fine. I'm simply a nosy guy and want to know everything about everything..

    • @energyoneelectric
      @energyoneelectric  Рік тому

      @@bosatsu76 good luck with your project and stay subscribed. My mind is exploding with more video tutorial ideas.

  • @stephenharrison4683
    @stephenharrison4683 Рік тому

    So glad UK electrics and the standard code of practice are so much safer and better. No rubber grommets in back box entries, the earth screws should be terminal type relying on a screw clamp for fixing not wedged under a screw head, no earth sleeving, never twist multiple cores together as it work hardens the copper and twist nuts should be banned! The stripping tool was about the only impressive item

    • @mckenziekeith7434
      @mckenziekeith7434 Рік тому

      There is at least one in every video like this. Believe me. We here in north america know how superior your UK codes are (or how superior you all think they are). How could we not know when there is an army of commenters just like you?

  • @AdamS-lh2ug
    @AdamS-lh2ug Рік тому

    I have 1 more, by cutting the grounds like that, he’s not maintaining the 6” as required by code.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Canadian code requires 6" for insulated conductors. Ground is not insulated. By all means please follow your local electrical code.

  • @noshirpanthakee
    @noshirpanthakee Рік тому +1

    This is perfect! I've actually been looking for a good video showing how the Pro's do it and finally found it! Thanks for the help! Looking forward to more videos!

  • @johnoleary5612
    @johnoleary5612 Рік тому

    I mean wire wire strippers

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Glad you noticed the strippers! Since I discovered them a few years ago they're now the only ones I use for stripping nmd cable. In the near future I am planning to do a tool review video on these strippers, but in the meantime here's a link where you can check them out. amzn.to/3B87QjF

  • @w.o.o.d.y
    @w.o.o.d.y Рік тому

    Gonna get ya balls felt by the electrical governing bodies if you run cable like that in the UK !! Totally unnecessary coiled cables equate to resistance in the cables. They also need to be in a conduit in the wall if less than 50mm from the surface in the UK. Love the box though, well thought out and designed.

    • @TwilightxKnight13
      @TwilightxKnight13 Рік тому

      Every country has their own hangups. There is no reason to require conduit in the walls of residential construction. Interesting that the UK deems that a hill to die on. I wonder who on the code committee is related to a conduit manufacturer ;-)

  • @MrTooTechnical
    @MrTooTechnical Рік тому

    Beautiful work. Then you cut all the grounds. And u r in Canada. Oh no.

  • @davey2k12
    @davey2k12 Рік тому

    Why not just cut it to length 🙂
    And don't you use grommets on the holes lol

    • @scottwilling5315
      @scottwilling5315 Рік тому +1

      1. Why not cut to length? For the reasons stated. In my neck of the woods (Canada, so literally neck of the woods) it's standard practice. I'm not sure I like the curly style, but that's a separate issue.
      2. As for grommets - ?? That box has integral cable clamps that are intended for installation just as illustrated.
      Where are you writing from? Are grommets code-required there? And what sort of grommets? The grommets I was familiar with as an electronics guy are unlike the hard plastic grommets I use as an electician, but both fit in round holes and neither strain-relieves the cable. Are you actually talking about a connector like a 40-40 or something?
      Really curious to know what's normal where you are.

  • @briantruxtonjr.6108
    @briantruxtonjr.6108 Рік тому +17

    "When I started doing electrical my wiring was messy" today is your first day it appears 🤣

    • @energyoneelectric
      @energyoneelectric  Рік тому +3

      How so? Should I be using a level for my wires, maybe a tape measure to make sure exactly 150mm of wire is sticking out of the box? If you've ever been a contractor you know that you need to do a good job and in a timely manner... there's no time to be finicky about little things.

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому +3

      @@energyoneelectric Well apparently anything goes for our brothers up north because we have standards for wire length, grounding, and box fill. It takes but a moment to ensure your wires are the proper length. There are quick tricks to do this. Thanks for the video!

    • @dicktracy4341
      @dicktracy4341 Рік тому +2

      Completely agree with you, ugly af.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому

      @@knowledgeableharpy2329 things like wrapping the ground around the screw? You mean things like that?

    • @jamesgarvey2090
      @jamesgarvey2090 Рік тому +1

      I would recommend keeping at least one grounding conductor at same length as hot and neutrals. Some switches are now requiring grounding, usually related to dimming and/or smart switches.

  • @franktib
    @franktib 6 місяців тому

    Stressing out the Americans with this install

  • @russellstephan6844
    @russellstephan6844 Рік тому +2

    Just an intense DYI'er here... But, small details add up to far fewer years-down-the-road issues.
    When possible, I *_always_* point wire nuts and such upwards. This keeps them from acting like buckets collecting drywall dust, sawdust, and decades of crap over the years. Should there be a plumbing, roofing, or other such leak/spill, the upwards orientated wire nuts won't act as cups to retain whatever it is that shouldn't have been there in the first place.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      I also point my wire nuts upwards but usually only outside and in bathrooms where there's a higher chance of moisture accumulating.

  • @JohnAbrahamCA
    @JohnAbrahamCA 6 місяців тому

    Don't cut the bonding wires or ground wires. That was the old method when switches were dumb. Now a days most switches are smart switches and they need ground and neutral wires in addition to the power wire and load wire.

    • @energyoneelectric
      @energyoneelectric  6 місяців тому

      You can keep 1 bonding wire uncut if you want, but dimmers and motion switches come with bonding wire attached to the switch so it can easily be put under a bonding screw.

  • @patrickhein9470
    @patrickhein9470 Рік тому +1

    Hmm. No way you could get away with that here. First your ground must be attached to your yoke of the device. Switch or not it has metal on it. Service loop? I guess if the sheetrockers are that bad. If the wires are in the back of the box and they tear up your wires using the Dremel method, make them pay for rewiring the house. Take down the sheet rock and repair it. Put your " loop" above or below the floor/ ceiling line. If you can't pull that in, you are using the wrong staples. Good sheetrockers can measure and precut holes for devices.

    • @geraldcreager4432
      @geraldcreager4432 Рік тому

      Most of the electricians I've worked with have stapled the romex down hard. I've failed an inspection because my romex wasn't secured to the satisfaction of the inspector (one whack with the hammer satisfied him, tho).

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Unfortunately some drywallers can be that bad. It's not common but on a few occasions I needed to pull in some extra wire due to damage. One drywaller years ago actually routed out a chunk of a live temporary receptacle.. along with cutting an alarm wire and putting a hole in the shower plumbing. That service loop is my insurance policy for those situations.. and it's completely legal here in Canada.

    • @patrickhein9470
      @patrickhein9470 Рік тому

      @@energyoneelectric Canada that explains it. I have seen videos of panels on their side. Legal in Canada but not in the states

    • @energyoneelectric
      @energyoneelectric  Рік тому

      @@patrickhein9470 have you seen them upside down? Lol. I do that all the time when main cable comes from under basement slab.

  • @marklee8226
    @marklee8226 Рік тому

    You'll save yourself a little bit of extra work and money by using non metallic nail on boxes.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      Actually the plastic boxes cost more than the metal boxes around here, so it doesn't make sense to switch cost wise.

  • @djchaisson
    @djchaisson Рік тому

    I respect the idea of service loops but I don’t agree with it. Your connections and splicing is great.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Thank you. You know, in a rare occasion where sometimes the customer wants to move a receptacle or switch over a stud space or higher or lower a bit that service loop can be a life saver for that extra few inches you may need.

    • @djchaisson
      @djchaisson Рік тому

      @@energyoneelectric it’s definitely a good option to have if you can and your inspector is cool. I’m in New England and it’s a crap shoot. Some inspectors want bushings on everything. No way around it.

  • @Lalasoth
    @Lalasoth Рік тому +2

    This would not pass code in America. I also cringed watching You cut the ground wires.
    In a plastic box there would be no way to ground the switch. In a Metal box even though you are grounding the box if you don't ground the switch directly they require grounding clips to attach the switch to the box. And greenies are required or you also fail.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      The plastic boxes I use in Canada have a metal bonding tab from the bonding screw up to the screw hole where the switch secures. Also the Eaton switches I use don't have a bonding screw. But definitely follow your local electrical codes.

    • @knowledgeableharpy2329
      @knowledgeableharpy2329 Рік тому

      American sparkies > Canadian sparkies

  • @stephentruckey8895
    @stephentruckey8895 Рік тому +2

    Coming from an actual IBEW electrician please don't listen to any of this. There are too many incorrect and unsafe practices going on here . . .

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      That's a pretty general statement. What specifically is incorrect and unsafe? Are you from America and assume that everyone else on UA-cam is too? If what I've shown you doesn't meet your local electrical code then make tweaks to make sure it does. But if what I'm doing is incorrect in my region then every job I do should be failing. What passes inspection in my Country may not pass in yours. You are incorrect for making an accusation like that.

  • @AdamS-lh2ug
    @AdamS-lh2ug Рік тому

    Also, I pity the fool who goes and installs a smart switch only to find out they don’t have a ground to hardly work with.

    • @energyoneelectric
      @energyoneelectric  Рік тому

      You can always get a piece of ground wire and put under the screw. Or Bond the dimmer's ground wire directly to the bonding screw.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому

      @@energyoneelectric I suppose at the end of the day, it’s all different where you are. We don’t leave service loops, and it’s beat into your head to make sure hose wires are all the way in the back of the box. This seems to be a Canadian thing, as I follow HomeReno Vision who is a Canadian and whenever I see electrical rough-ins in the background I’ve seen it before. I think you’ll find a lot of Americans calling it ugly. It also just doesn’t professional down here and I’m certain inspectors would complain.

    • @mckenziekeith7434
      @mckenziekeith7434 Рік тому +2

      Its a metal box. You can make a ground anywhere if you have a drill and a green screw.

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому +2

      @@mckenziekeith7434 a 10-32 thread.

  • @dallasarnold8615
    @dallasarnold8615 Рік тому +17

    The curl you put in looks sloppy and amateurish to me. I am not positive, but I believe it is a code violation in the U.S.

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      Thanks for watching!

    • @jsb7546
      @jsb7546 Рік тому +2

      That's weird I've seen plenty of guys put service loops idk what the hell your talking about. It's not a code violation and actually depending on your local they may require service loops in certain situations I like them because it helps the people who go after you especially if another trade (cough drywallers cough) come in and fuck things up you have extra to work with just in case. Fucking arm chair electricians you go and wire that shit then if doesn't looks good enough. It's a service loop dude you can only do so much to make it look "good" and plus this is resi you think he has the time for making it perfect hell I'm surprised he's even got the time to put service loops in the first place damn near a miracle I say. Go actually work one day on a job site and than come back to the conversation.

    • @dallasarnold8615
      @dallasarnold8615 Рік тому +2

      @@jsb7546 I retired 4 years ago. No need to be out there again. Did my 55 years of construction already.

    • @OrdinaryDude67
      @OrdinaryDude67 Рік тому +2

      It’s going to be behind drywall and not visible to anyone. And afaik there’s no code violation involved. Was your 55 years as an electrician?

    • @AdamS-lh2ug
      @AdamS-lh2ug Рік тому +5

      The bigger issue is how he grounded the box imo. You’re allowed 12” from your staple, that being said, here in MN, never seen “service loops” for anything outside of low volt. Also, no offense to this guy, but if this is what he considers neat, I would hate to see what he used to do.

  • @carlgreenfield6765
    @carlgreenfield6765 Рік тому

    Wow code violations you absolutely need your ground wire at a switch! Also all wires must be ae to be out of the box a min of 6" those grounds are now way to short! Not to mention its poor practice to install 2 wires under 1 screw like that and to not wrap the wire around the screw.

    • @krakenwoodfloorservicemcma5975
      @krakenwoodfloorservicemcma5975 Рік тому

      It’s really poor practice.. takes 12 seconds to splice the ground wires together.. can cut them short and neatly fold the nut to the back of the box.

    • @energyoneelectric
      @energyoneelectric  Рік тому +3

      There are no code violations in this video according to Canadian electrical code, where I'm located.

    • @raggarex
      @raggarex Рік тому +2

      You don't need to wrap the wire around the screw. There are shoulders on either side of the ground screws to provide a channel and ensure the wires stay in place. It is allowed under Canadian code and is common practise. It could be that the ground screw design is different where you are.

  • @iantaylor6538
    @iantaylor6538 Рік тому +2

    For a pro, you don't half make it look like an untrained person did it.........

  • @eehibew
    @eehibew Рік тому

    I am a Master electrician and worked in the trade for 55 years. DO NOT COPY THIS INSTALLATION. I would fire him if he worked for me.Grounds are bad. Loops are bad. Just looking for trouble!!!!!!!!!!!!!!!!!!

    • @energyoneelectric
      @energyoneelectric  Рік тому

      Have I done anything in the video against code.. or are you just stating your opinion? You are entitled to it.

  • @bb590
    @bb590 Рік тому

    NEUTRALS WILL NEVER BE PULLED OUT AGAIN? this guy has NEVER worked on a smarthome! Every switch needs a NEUTRAL AND GROUND! This is for 1990s electricans!

    • @energyoneelectric
      @energyoneelectric  Рік тому +1

      I understand certain switches need neutrals and grounds...in which case you can pull out the neutral and splice onto it, and you can put your ground directly under the bonding screw. Not a big problem as some of you make it out to be.

  • @danb5339
    @danb5339 Рік тому

    Please don't staple the cables to the timber 😪 The next poor bugger who wants to get a cable down the wall can't use an existing cable as a draw

    • @skiball83
      @skiball83 Рік тому +1

      Sorry but thats code. Run conduit if you dont want that issue.

    • @energyoneelectric
      @energyoneelectric  Рік тому +4

      It's code in Canada to support your wires. The next guy (if ever at all) will need to fish it in.

    • @danb5339
      @danb5339 Рік тому

      @@energyoneelectric Oh, I see, fair enough. It's not code here in NZ hence don't encounter it too often. We regularly use existing cables as draw lines for running controller cables etc

  • @derekmusgrove6725
    @derekmusgrove6725 Рік тому

    Lol SMH

  • @dicktracy4341
    @dicktracy4341 Рік тому

    Looks like Crap to me.... 20+ year electrician herr

    • @energyoneelectric
      @energyoneelectric  Рік тому +3

      You gotta love when guys start throwing out years of experience.. like it has a lot of weight. I've met electricians who have done industrial or commercial work all their life, but can't wire a house or understand basic circuitry. Bending pipe for 20 years makes you a phenomenal pipe bender, that's it. Saying my work looks like crap because you have 20 years experience doesn't bother me much.. what matters more to me is the local electrical inspectors who have told me that I do some of the cleanest work.

  • @justincase4812
    @justincase4812 Рік тому

    OCD is strong here. All very good, but not the only way to be sure. More "pros" need to know this, and not proselytize their way as the only way as long as it's code compliant.